• Title/Summary/Keyword: All-on-4 보철물

Search Result 72, Processing Time 0.026 seconds

The Influence of Bonding Strength and Interface Characteristics to Bonding Agent and Veneer Ceramics on Metal-Ceramic Prosthetics (결합재와 베니어세라믹이 금속-세라믹 보철물의 전단결합강도와 계면특성에 미치는 영향)

  • Kim, Min-Jung;Choi, Sung-Min;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.349-357
    • /
    • 2011
  • Purpose: In this study, for the reasons of observing the changes when using bonding agent with Ni-Cr alloy and Co-Cr alloy and using VM13 and Vintage MP ceramic which have the disparity in coefficient of thermal expansion, it is carried out to evaluate the characteristics of the bonding agent through the analysis of the interface between metal and ceramic and the analysis of bond strength by variable. Methods: The surface treatment was performed on the two kinds of alloy(Ni-Cr alloy and Co-Cr alloy) specimens, which were sandblasted and were treated with bonder application. The metal-ceramic interfaces were analyzed with EPMA in order to ionic diffusion, and the shear test was performed. Results: As a result of observation of metal-ceramic interfacial properties, it was observed that Cr atoms were spread from the alloy body to the ceramic floor in the specimen of Group B. It was also seen that Cr, W atoms were spread from the alloy body to the ceramic floor in the specimen of Group S. In consequence of observing Shear bond strength, it was calculated that the specimen of BSV was 27.75(${\pm}11.21$)MPa, BSM was 27.02(${\pm}5.23$)MPa, BCV was 30.20(${\pm}5.99$)MPa, BCM was 27.94(${\pm}10.76$)MPa, SSV was 20.83(${\pm}2.58$)MPa, SSM was 23.98(${\pm}3.94$)MPa, SCV was 32.32(${\pm}4.68$)MPa, and SCM was 34.54(${\pm}10.63$)MPa. Conclusion: In the metal-ceramic interface of Bellabond plus sample group, diffusion of Cr atoms was incurred and diffusion of C Cr atoms and W atoms in the sample group of $Starloy{(R)}\;C$ was observed. Using bonding agent showed the higher bond strength than using the sand blasting treatment. In the Bellabond plus alloys, the specimen group with the use of binding materials showed higher shear bond strength, but didn't show statistically significant differences (p>0.05). In the $Starloy{(R)}\;C$ alloys, the specimen group with the use of binding materials showed higher shear bond strength and statistically significant differences(p<0.05). In terms of VM13 ceramic, it was in the Bellabond plus alloys that the high shear bond strength was showed, but there's no statistically significant differences(p>0.05). In terms of Vintage MP ceramic, it was in the $Starloy{(R)}\;C$ alloys that the high shear bond strength was showed and statistically significant differences(p<0.05). Metal-ceramic to fracture of the shear strength measurements and an analysis of all aspects of military usage fracture of the composite, respectively.

Antimicrobial activity of dental polishing bur material with fluoride ion (불소이온을 함유한 연마용 버 재료의 항균력 연구)

  • Jeong, Insun;Kim, Ji-Hyun;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.201-206
    • /
    • 2020
  • Purpose: The purpose of this study is to evaluate the antimicrobial activity on the dental bur with fluoride for S. mutans. Materials and methods: 0 ppm, 300 ppm, 500 ppm, 1,000 ppm, 1,450 ppm fluoride ion is added to a specimen. S. mutans was incubated for 24 hours, the number of S. mutans were counted. Kruskal-Wallis and MannWhitney analysis were used SPSS 25.0 (IBM SPSS 25.0, Chicago, IL, USA). Results: The mean S. mutans counts of 0 ppm, 300 ppm, 500 ppm, 1,000 ppm, and 1,450 ppm were 374.0 ± 12.6, 251.0 ± 66.7, 111.4 ± 35.6, 41.6 ± 11.7 and 13.2 ± 4.6, respectively. All groups except the control and 300 ppm showed statistically significant. Conclusion: Thus, more than 500 ppm fluoride ion showed the statistically significant antimicrobial activity. 1,450 ppm group showed the highest antimicrobial activity. This study showed the clinical possibility for dental caries protection and antimicrobial activity of dental bur.

Effect of universal primer on shear bond strength between resin cement and restorative materials (다용도 프라이머가 레진 시멘트와 수복재의 전단 결합 강도에 미치는 영향)

  • Kim, Na-Hong;Shim, June-Sung;Moon, Hong-Suk;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.112-118
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the difference in shear bonding strength between resin cements to dental materials when a universal primer (Monobond plus) was applied in place of a conventional primer. Materials and methods: Four groups of testing materials: gold alloy (Argedent Euro, n = 16), non precious metal (T-4, n = 20), zirconia (Cercon, n = 20) and glass ceramic (IPS e.max press, n = 20), were fabricated into discs, which were embedded in an acrylic resin matrix. The gold alloy specimens were airborne-particle abraded, 8 of the specimens were coated with Metal primer II, while the remaining 8 specimens were coated with Monobond plus. The non precious and zirconia specimen were airborne-particle abraded then, the control group received Alloy primer coating, while the other was coated with Monobond plus. Glass ceramic specimens were etched. 10 specimens were coated with Monobond-S and the remaining specimens were coated using Monobond plus. On top of the surface, Multilink N was polymerized in a disc shape. All of the specimens were thermal cycled before the shear bonding strength was measured. Statistical analysis was done with Two sample $t$-test or Mann-Whitney U test (${\alpha}$=.05). Results: There were no significant differences in bonding strength depending on the type of primer used in the gold alloy and glass ceramic groups ($P$>.05), however, the bonding strengths of resin cements to non precious metal and zirconia groups, were significantly higher when the alloy primer was used ($P$<.05). Conclusion: Within the limitations of this study, improvement of universal primers which can be applied to all types of restorations is recommended to precious metals and zirconia ceramics. But, the bond strengths of non precious metals and zirconia ceramics were significantly lower when compared to a 10-MDP primer. More research is needed to apply universal primers to all types of restorations.

The effect of repeated firings on the color of zirconia-based all-ceramic system (반복 소성이 지르코니아 전부도재관의 색조에 미치는 영향)

  • Jang, Jung-Eun;Kim, Mu-Hyon;Yun, Mi-Jung;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.73-79
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the effect of repeated firings on the color of zirconia restoration with different shading method. Materials and methods: Three different types of zirconia frameworks (adding metallic pigments to the initial zirconia powder before sintering (Group NM), dipping the milled frameworks in dissolved coloring agents (Group KI), or application of liner material to the sintered white frameworks (Group KW) were used to support A3 shade dentin porcelain. Repeated firings (3, 5, or 7) were performed, color differences among ceramic specimens were measured using a colorimeter. Repeated measurements analysis of variance (ANOVA) was used to analyze the data for significant difference. The Tukey Honestly Significant Different (HSD) test was used to perform multiple comparisons (${\alpha}$ = .05). Results: 1. $L^*a^*b^*$ values of the ceramic systems were affected by the number of firings (1, 3, 5 or 7 firings) (P < .001) and shading methods (P < .001). 2. As the number of firings increased, the $L^*$ (for all groups) and $a^*$ value (for KW and NM groups) decreased and the $b^*$ value(for all groups) increased. 3. The mean color differences caused by repeated firings were perceptible (${\Delta}E$ > 1) for group KW and KI fired after 3 times, except for group NM fired after 7 times. 4. In order of decreasing ${\Delta}E$ value fired after 7 times, the values were group KI(${\Delta}E$ = 2.26) > group KW (${\Delta}E$ = 1.47) > group NM (${\Delta}E$ = 1.08) (P < .001). Conclusion: Repeated firings influenced the color of the zirconium-oxide all-ceramic specimens with different shading methods.

Study about shear bond strength of zirconia core used in dental prosthesis (치과 보철물에 사용되는 지르코니아 코어의 전단결합강도에 관한 연구)

  • Sim, Ji-Young;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2011
  • Purpose: This study aimed to investigate the shear bond strength by manufacturing the veneering porcelain on the IPS e.max $ZirCAD^{(R)}$ zirconia core, using the layering technique and heat-pressing technique, and to evaluate the clinical stability by comparing to the conventional metal ceramic system. Methods: The Schmitz-Schulmeyer test method was used to evaluate the core-veneer shear bond strength of zirconia core ceramic(IPS e.max $ZirCAD^{(R)}$) and their manufacture recommended two veneering ceramic systems(IPS e.max $ceram^{(R)}$, IPS e. max $ZirPress^{(R)}$). A metal ceramic system(Bellabond $plus^{(R)}$, VITA $VM13^{(R)}$) was used as a control group for the two all ceramic system test groups. The maximum loading and shear bond strength was measured. The average shear strength(MPa) was analyzed with the one-way ANOVA and the Tukey's test(${\alpha}$=.05). The fracture specimens were examined using Microscope to determine the failure pattern. Results: The mean shear bond strengths(SD) in MPa were MBSB control 43.62(2.13); ZBSB 18.65(1.76); ZPSB 18.89(1.54). The shear strengths of the zirconia cores were not significantly different(P>.05). Microscope examination showed that zirconia specimens presented mixed failure, and base metal alloy specimens showed adhesive failure. Conclusion: There was no siginificant different between the layering technique and the heat pressing technique in the veneering methods on the zirconia cores. None of the zirconia core and veneering ceramics could attain the high bond strength values of the metal ceramic combination.

LONGEVITY AND FAILURE ANALYSIS OF FIXED RESTORATIONS SERVICED IN KOREA (국내에서 제작된 고정성 보철물의 수명과 실패 요인 및 양상)

  • Shin Woo-Jin;Jeon Young-Sik;Lee Keun-Woo;Lee Ho-Yong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.158-175
    • /
    • 2005
  • Statement of problem. Every effort has been continually made to obtain objectivity in measuring the longevity of fixed restorations, such as by establishing unified judgement standard for deciding success and adopting statistical method that analyzes the data of successful and failed cases at the same time. In Korea, however desired level of development has not to be made in this field yet. Purpose. This study, adopting California Dental Association (CDA) quality evaluation system, established objective standard for deciding success, and inferred the longevity of fixed restorations and their failure analysis through adopting Kaplan-Meier survival analysis. Material and method. In order to assess the longevity of flxed restorations serviced in Korea and causes of failure, a total of 1109 individuals (aged 15-74, 716 women and 393 men loaded with 2551 unit fixed restorations, and 1934 abutments) who lived in Kyung-In Province were examined and the findings were as follows : Results. 1. Length of service of fixed restorations serviced in Korea was 6.86$\pm$0.15 yr (mean), 5.5 yr (median), and the rate of success was 65.82% in 5 year survival, and 21.15% in 10 year survival. 2. When there was patient's need for replacing old prosthetics, longevity of fixed restorations was 7.51$\pm$0.27 yr (mean), 7 yr (median), and the rate of success was 61.08% in 5 year survival, and 17.57% in 10 year survival. 3. Longevity of fixed restorations was longest in the over-sixty age group(9.21$\pm$0.66) and that of the teen age group(3.39$\pm$0.28) was shortest (p<0.05). 4. Longevity of fixed restorations of women (7.38$\pm$0.18 years) was longer than that of men (6.00$\pm$0.26) (p<0.05). 5. As for the provider factor (such as unlicensed performers, university hospitals, and private clinic), there was no statistically significant difference in longevity of fixed restorations. 6. Defective margin (34.78%). periodontal disease (12.15%), periapical involvement (11.73%), was the most frequent causes of failure and poor esthetics group showed the longest life above all (p<0.05). Actual frequent causes of failure after removing old prosthetics were defective margin, periapical involvement, periodontal disease and uncemented restoration. In 75.67% of the cases, abutment state after removing old prosthetics was good enough for loading another prosthetics. 7. There was found to have statistically significant influence between longevity of single crown (6.35$\pm$0.20 yr) and that of 3 unit fixed restorations (7.60$\pm$0.30 y) (p<0.05). In each case the most frequent cause of failure was defective margin. 8. The number of cantilever pontic, pontic/abutment ratio, oral hygiene status were found to have no statistically significant influence on longevity of fixed restorations in all groups (p>0.05). 9. Longevity of fixed restorations made of non precious metal was longest (9.60$\pm$0.40 yr) semi precious and precious trailing behind(p<0.05). 10. Group function group (37.04%) and partial group function group (44.62%) were predominant in frequency but showed no correlation between them and among different types of occlusal plane and different types of occlusal surface (p>0.05). 11. Longevity of fixed restorations was longest in the centric interference group(9.35$\pm$0.62) (p<0.05) among different types of occlusal interference. Conclusion. We found that longevity of fixed restorations serviced in Korea is affected by age, gender and type of material, and that most frequent cause of failure is defective margin. In order to assess the accurate longevity of axed restorations, unified research design. overcoming inter-observer difference and establishing the objective research items are needed. Furthermore, it is thought that prospective approach through thorough study and regular follow-ups is needed just from the start of research. Nationwide detailed studies on length of service of fixed restorations manufactured in Korea are hoped to be conducted hereafter.

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.

The comparison of microtensile bond strength with immediate and delayed dentin sealing (즉시 상아질 봉쇄와 지연 상아질 봉쇄에 따른 상아질 접착의 미세인장 결합강도 비교)

  • Lee, Heung-Bae;Han, Chong-Hyun;Shim, Jun-Sung;Kim, Sun-Jai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.372-380
    • /
    • 2008
  • Purpose: The purpose of this study was to evaluate the effect of various methods of dentin bonding agent application on microtensile bond strength between dentin and resin, using a 2-step etch-and-rinse dentin bonding agent. Material and methods: Twenty freshly extracted human molars were obtained and divided into 4 groups of 5 teeth. 2-step etch-and-rinse dentin bonding agent was used for all groups. The control specimens were prepared using a direct immediate bonding technique. The delayed dentin sealing (A, C) specimens were prepared using an indirect approach with delayed dentin sealing. For group A, resin was built-up on uncured dentin bonding agent, and for group C, resin was built-up on pre-cured dentin bonding agent. Preparation of the immediate dentin sealing (B) specimens also used an indirect approach with immediate dentin sealing immediately following preparation. All teeth were prepared for a microtensile bond strength test. Specimens were stored in water for 24 hours. Ten beams (1.0 ${\times}$ 1.0 ${\times}$ 11 mm) from each tooth were selected for testing. Bond strength data (MPa) were analyzed with a one-way ANOVA test, and post hoc comparison was done using the Scheffe's test. Results: The mean microtensile bond strengths of control group, B and C (DDS with pre-cure) were not statisticaaly different from each other at 32.7, 33.3, 34.2 MPa. the bond strength for group A (DDS without pre-cure), 19.5 MPa, was statistically different (P < .01) from the other 3 groups. Conclusion: When preparing teeth for indirect bonded restorations, DDS with pre-curing dentin bonding agent and IDS results in the same bond strength between dentin and resin. On the contrast, the bond strength was decreased when DDS without pre-curing dentin bonding agent was used.

A Study on the Stress Distribution of Condylar Region and Edentulous Mandible with Implant-Supported Cantilever Fixed Prostheses by using 3-Dimensional Finite Element Method (임플란트 지지 캔틸레버 고정성 보철물 장착시 과두와 하악골의 응력 분포에 관한 3차원 유한요소법적 연구)

  • Kim, Yeon-Soo;Lee, Sung-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.283-305
    • /
    • 2001
  • The purpose of this study was to analyze the stress distribution of condylar regions and edentulous mandible with implant-supported cantilever prostheses on the certain conditions, such as amount of load, location of load, direction of load, fixation or non-fixation on the condylar regions. Three dimensional finite element analysis was used for this study. FEM model was created by using commercial software, ANSYS(Swanson, Inc., U.S.A.). Fixed model which was fixed on the condylar regions was modeled with 74323 elements and 15387 nodes and spring model which was sprung on the condylar regions was modeled with 75020 elements and 15887 nodes. Six Br${\aa}$nemark implants with 3.75 mm diameter and 13 mm length were incorporated in the models. The placement was 4.4 mm from the midline for the first implant; the other two in each quardrant were 6.5 mm apart. The stress distribution on each model through the designed mandible was evaluated under 500N vertical load, 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. The load points were at 0 mm, 10 mm, 20 mm along the cantilever prostheses from the center of the distal fixture. The results were as follows; 1. The stress distribution of condylar regions between two models showed conspicuous differences. Fixed model showed conspicuous stress concentration on the condylar regions than spring model under vertical load only. On the other hand, spring model showed conspicuous stress concentration on the condylar regions than fixed model under 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. 2. Fixed model showed stress concentration on the posterior and mesial side of working and balancing condylar necks but spring model showed stress concentration on the posterior and mesial side of working condylar neck and the posterior and lateral side of balancing condylar neck under vertical load. 3. Fixed model showed stress concentration on the posterior and lateral side of working condylar neck and the anterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior sides of working and balancing condylar necks under horizontal load linguobuccally. 4. Fixed model showed stress concentration on the posterior side of working condylar neck and the posterior and lateral side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 20 degree oblique load. 5. Fixed model showed stress concentration on the anterior and lateral side of working condylar neck and the posterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 45 degree oblique load.. 6. The stress distribution of bone around implants between two models revealed difference slightly. In general, magnitude of Von Mises stress was the greatest at the bone around the most distal implant and the progressive decrease more and more mesially. Under vertical load, the stress values were similar between implant neck and superstructure vertically, besides the greatest on the distal side horizontally. 7. Under horizontal load linguobuccally, buccal 20 degree oblique load and buccal 45 degree oblique load, the stress values were the greatest on the implant neck vertically, and great on the labial and lingual sides horizontally. After all, it was considered that spring model was an indispensable condition for the comprehension of the stress distributions of condylar regions.

  • PDF

Study on Acknowledge and State of Clinical Experience for 3-years Dental Technology Department (3년제 치기공과 임상실습에 대한 인식 및 실태조사 - 일부 치과기공소 소장을 중심으로 -)

  • Park, Myung-Ja
    • Journal of Technologic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.41-57
    • /
    • 1995
  • This study was conducted to collect and analyze previous information in order to manage efficience, improve experience effect and promote employment rate. The questionnaire interview with 27 chief of dental Laboratory refered clinical experience in technology department about clinical experience in 14 Jumior colleges were also investigated. The results were summarried as follows : The portion of age of 35-39 among chief of dental Laboratory was 40.7% which was the highest, that of male was 96.3%, that of junior college graduate was 97.5%, that of 10years experience was 92.6% and that of ceramic technician was 85.2%, 63.0% dental laboratory for clinical experience was a bore space of 30pyong. Aspect of dental laboratory management, manufacturing all part of prosthetic restoration was 29.6%, othodontic appliance and ceramic restoration was 7.4%, 3.8%, each. The percentage of 40.7 was having connection with 30-3a dental clinics and referring case per day was 10-19 cases(40.7%), manufacturing time of referred prosthetic restoration was 3-4 days(77.8%), places preparing seminar room for education was 29.6%, above a place of 40pyong was 11.1% 30-34 pyong and 35-39 pyong was 7.4% each. During training of 2 years education course student, 18.5% was rack of thorough occupational career. While 44.4% will want the more salary among 3years education course student, 74.1% will expect the more dental techmicians would engaged in their field, 51.9% will hope improve of their theory and practice, 29.6% be expected better skill and 14.8% be expected better theory. Attitude of clinical experience places was distributed by 59.3% of offering only experience chance, 25.9% of wasting time and 29.0% of annoying. The big emphasis of climical experience was thorough occupational career(44.4%). The clinical experience places of our college were selected after direct visiting, so their condition of management was not that bad but most of dental laboratory were poor in management state and working environment. Therefore it is difficult to choose appropriate places and dental Laboratory are also limited manpower and time as suppliers. So that it recommended to induce flexible management of experience period by interval and rotation of experience places among college and to applicate intern-system for employment ant industry-college cooperation aspect.

  • PDF