• 제목/요약/키워드: All-Weather Construction

검색결과 63건 처리시간 0.023초

가변 제한속도 표지판 크기기준 정립을 위한 안개재현 현장실험 (Fog Generated Field Test for Criteria of Sign Size of Variable Speed Limit Signs)

  • 김용석;이석기;김솔람
    • 한국도로학회논문집
    • /
    • 제18권6호
    • /
    • pp.87-96
    • /
    • 2016
  • OBJECTIVES : A fog generated field test was conducted to analyze the relationship between different sizes of variable speed limit signs and the legibility distance under various fog density conditions. By using this study, appropriate sizes of signs can be selected depending on the density of fog. METHODS : An actual tunnel was selected as the area for this test, as other places cannot maintain the fog condition because of rapid air current. A total 121 subjects were recruited for this test, which took place over the course of four days. The test on the first day was conducted under normal weather conditions for comparison. Visibility-distance detecting sensor was used to measure the visibility distance due to the fog density time, simultaneously with the evaluation of legibility distance by subjects. RESULTS : The test results show the relationship between the different sizes of signs and the legibility distance corresponding to the visibility distance due to both non-fog and fog generated conditions. According to the technical test results, appreciable amount of reduction in legibility distance due to fog was resulted in all sizes of signs. Moreover, the legibility distance is reduced proportionately with the decrease in the visibility distance due to fog. CONCLUSIONS : The results of this study can be used to select appropriate sizes of valuable speed signs under fog conditions. Hence, drivers can expect to have more room to respond to adverse weather conditions, thereby reducing the risk of accidents.

CFT 기둥용 초고강도 충전콘크리트에 관한 연구 (A Study on High Strength Concrete of Concrete Filled Steel Tube Column)

  • 정근호;임남기;이영도
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.127-132
    • /
    • 2004
  • CFT(Concrete Filled Steel Tube) is a structure of circular or squared of steel column filled with concrete. The steel tube holds the concrete inside and that makes this structure to perform superior features on stiffness, proof stress, transformation, fire resistance and construction itself. In this study, by over the 800kgf/$\textrm{cm}^2$ of high strength concrete for CFT column, research has been done on the basic property of matter such as fluidity, resistance on segregation, compressive strength, setting icons of the concrete filled in the steel tube under conditions of standard weather. Physical properties of concrete for CFT that Concrete with silica fume, fly ash of air entraining and high-range water reducing agent, that used to CFT column research purpose to find the most ideal composition, which is achieved by the investigation in the concrete's property of matter like ability of Slump, Slump Flow, Air content, Bleeding, and Settlement. For this study, experiments which are bused on obtained the result through physical test are practiced, with all of the experiment, specimens only for control are produced in each method of curing and analyzed to relations with core strength in mock-up test. In mock-up test, the research is studied compactability of concrete filled in tube and degree of hydration hysteresis, as a basic reference for applying to field of CFT column which is used over 800kgf/$\textrm{cm}^2$ high strength concrete.

배합수 냉각방법 및 지연제 사용에 따른 서중 원전콘크리트의 특성 (Properties of Hot Weather Nuclear Power Plant Concrete with Water Cooling Method and Retarding used)

  • 이승한;정용욱;장석수;여인동;최종오
    • 한국산학기술학회논문지
    • /
    • 제14권9호
    • /
    • pp.4602-4609
    • /
    • 2013
  • 온도차가 극심한 하절기와 동절기 콘크리트 타설의 경우 각종 균열의 발생, 콘크리트 품질불량, 내구성 및 강도저하 등 다양한 문제를 야기 시키고 있다. 특히 원전콘크리트의 경우 대량의 타설로 인한 4계절 연속시공이 이루어져 서중환경에서 콘크리트 품질관리에 많은 문제점이 발생되고 있는 실정이다. 이에 본 연구에서는 서중환경에서 많이 사용되어지는 프리쿨링 공법 중 배합수 냉각방법과 지연제 사용이 원전콘크리트의 특성에 미치는 영향을 검토하였다. 배합수 냉각방법은 냉수 $5^{\circ}C$와 Ice Flake 50% 치환사용 하였으며, 지연제 사용에 따른 원전콘크리트의 굳지 않은 콘크리트 및 경화 후 콘크리트의 특성을 검토하였다. 굳지 않은 콘크리트 특성으로는 슬럼프, 공기량, 응결시간 및 경화 후 압축강도를 측정하였으며, 단열거푸집을 제작하여 손실되는 열을 최소화시켜 각 온도조건하에서 수화열을 측정하였다. 실험결과, 슬럼프 및 공기량 경시변화 종료시간은 $20^{\circ}C$에서 120분, $40^{\circ}C$에서 40분으로 나타났으며, 관입 저항에 의한 응결시간은 배합수 냉각방법 및 지연제 사용 모두 초결과 종결을 지연시키는 것으로 나타났으나, 외기온도가 상승할수록 지연폭은 감소하는 것으로 나타났다. 수화열은 배합수 냉각방법 모두 최고온도의 저감과 도달시간을 지연시키는 것으로 나타났으나, 지연제 사용의 경우 최고온도 저감효과는 없는 것으로 나타났다. 또한 재령별 압축강도의 경우 3일, 7일의 초기재령에서 Plain과 비교하여 낮은 강도 값을 나타내었으나, 재령 28일에서는 설계기준강도를 모두 만족시키는 것으로 나타났다.

합류식하수도 월류수 관리를 위한 초기우수 저류조 설계방안 연구 (A Study on First Flush Storage Tank Design for Combined Sewer Overflows (CSOs) Control)

  • 손봉호;어성욱
    • 한국물환경학회지
    • /
    • 제27권5호
    • /
    • pp.654-660
    • /
    • 2011
  • One of the best way to control Combined Sewer Overflow (CSO) is proposed to construct first flush storage tank. But there is little known parameters for optimum design of these facilities. This study was conducted to get optimum design parameters for a first flush storage tank construction. The optimization of the tank is generally based upon some measure of SS(Suspended Solid) mass holding efficiency. Water quality deterioration of receiving water body happened right after first time occurring rainfall in dry weather seasons. So, design rainfall intensity is used at 2 mm/hr for peak of monthly average intensities of dry seasons. The capacities for each evaluated catchment are designed from 14.4 min to 16.1 min HRT of CSOs flow at design rainfall intensity. Owing to all storage tanks are connected to interception sewer having a redundancy, the suggested volume could be cut down.

옥상녹화용 방근층 구성재료의 방근성능에 관한 실험적 연구 (Resistance to Root Penetration of Root Barrier for Green Roof System)

  • 김현수;장대희;최수경
    • 한국건축시공학회지
    • /
    • 제8권6호
    • /
    • pp.123-129
    • /
    • 2008
  • The purpose of this study is to test performances of 14 types of root barrier materials by applying testing plant: and soils suitable for weather and natural features of Korea. For testing Plants, Plioblastus pygmaed Mitford A and Pyracantha angustifolia have been selected. For testing soil, mixture of pearlite and peat moss in 3:1 ratio Testing container has been fabricated with duplicated structure having inner and outer containers. And the outer container has 2 hinges on its side wall to allow opening and closing. Wet rock wool with 50mm in thickness has been inserted between inner and outer containers to allow root to penetrate through root barrier material and continue to grow. We planted 12 Plioblastus pygmaed Mitford A. and 4 Pyracantha angustifolia per one testing container. Three testing samples have been made for 1 type of root barrier material, which become a total 42 specimens. Planted testing samples have been installed within the greenhouse, which will be observed regularly for 2 years from now on. We started test from July 11, 2008 and had performed intermediate observations every month for initial 3 months. From the 3rd intermediate observation on Sept. 18, we confirmed that 6 types of roe barrier materials have penetrated roots. Even though two types of them have been generally used as root barrier materials for roof planting system, all of three testing samples have a lot of penetrated roots. This result proves that it is not reasonable to introduce testing methods of root barrier from Europe. USA or Japan.

옥상녹화용 방근층의 방근성 시험조건 설정 및 주요 방근소재에 대한 3개월간의 중간관찰 결과 (Examination Conditions of Root Barrier for Green Roof System and Result of Intermediate Observation of Three Months against Representative Root Barrier)

  • 신윤호;장대희;김현수;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.245-249
    • /
    • 2008
  • The purpose of this study is to test performances of 14 types of root barrier materials by applying testing plants and soils suitable for weather and natural features of Korea. For testing plants, Plioblastus pygmaed Mitford A. and Pyracantha angustifolia have been selected. For testing soil, mixture of pearlite and peat moss in 3:1 ratio(volume). Testing container has been fabricated with duplicated structure having inner and outer containers. And the outer container has 2 hinges on its side wall to allow opening and closing. Wet rock wool with 50mm in thickness has been inserted between inner and outer containers to allow root to penetrate through root barrier material and continue to grow. We planted 12 Plioblastus pygmaed Mitford A. and 4 Pyracantha angustifolia per one testing container. Three testing samples have been made for 1 type of root barrier material, which become a total 42 specimens. Planted testing samples have been installed within the greenhouse, which will be observed regularly for 2 years from now on. We started test from July 11, 2008 and had performed intermediate observations every month for initial 3 months. From the 3rd intermediate observation on Sept. 18, we confirmed that 6 types of root barrier materials have penetrated roots. Even though two types of them(EDPM Sheet, Polyethylene Sheet) have been generally used as root barrier materials for roof planting system, all of three testing samples have a lot of penetrated roots. This result proves that it is not reasonable to introduce testing methods of root barrier from Europe or Japan.

  • PDF

비콘 DGPS기반 펌프식 해상준설 공정관리시스템의 구축 (Construction of Hydrographic Pump Dredge Process Management System Based on Beacon DGPS)

  • 이진덕;이재빈;김현호
    • 한국측량학회지
    • /
    • 제29권6호
    • /
    • pp.613-620
    • /
    • 2011
  • 해상 준설성과의 과학적 평가를 위해서는 준설선의 유도 위치, 준설수심 및 준설 토사량 등의 준설공정을 실시간으로 모니터링하면서 작업공정을 관리하고 평가할 수 있는 시스템의 구축이 필요하다. 본 연구에서는 기상조건과 거리에 상관없이 상시측량이 가능한 GPS 측량방법을 응용하는 정밀위치측량과 항행의 두가지 기법에 수심측정기법 등을 병용하는 해상측량시스템을 개발하고자 하였다. Beacon DGPS를 기반으로 하는 선박위치측정, GPS/Gyro 통합장비에 의한 선박방향 측정, 준설심도와 붐대위치 측정, 조위에 따른 준설심도 보정 등의 기능을 갖춘 해상준설선의 유도 및 위치관리시스템을 구축하고 준설선의 작업 현황을 실시간으로 모니터링하면서 정확히 작업을 유도할 수 있는 운용프로그램을 개발하였다. 본 연구에서 개발된 시스템은 해상준설 또는 해상건설산업에서 원가 절감에 크게 기여할 수 있을 것으로 기대된다.

기상방재 대책수립을 위한 아시아지역 기상모형에 필요한 지표경계조건의 구축 (Construction of Surface Boundary Conditions for the Regional Climate Model in Asia Used for the Prevention of Disasters Caused by Climate Changes)

  • 최현일
    • 한국방재학회 논문집
    • /
    • 제7권5호
    • /
    • pp.73-78
    • /
    • 2007
  • 전세계적으로 지구온난화와 기상이변으로 인한 인명과 재산의 피해는 해마다 증가하고 있으며, 최근 한반도의 기후와 기온은 지구평균치보다 큰 변화가 일어나고 있다. 지구전체기상모형(Global Climate Model 또는General Circulation Model GEM)보다 고해상도의 모의가 가능한 지역기상모형(Regional Climate Model RCM)은 기후 변동, 변화 및 그 영향과 관련된 여러 문제들을 파악하는데 사용된다. 이러한 기상모형을 위한 기존 입력자료들의 가용성, 정확도, 그리고 일관성의 결여로 인하여 제한되고 있는 모형의 예측능력 향상을 위해 새로운 지표경계조건들(Surface Boundary Condition SBC)의 필요성이 요구되고 있다. 따라서, 정확도 높은 측정자료의 확보와 과학적 근거에 의한 자료선택 및 결측보정이 새로운 지표경계조건 구축에 선결조건이 되어야 한다. 이 연구의 목적은, 기상방재 수립을 위한 아시아 지역기상모형에 필요한 정확도 높은 지표경계조건 자료를 구축하는데 있다. 산정된 지표경계조건들은 30km 크기의 격자망으로 구성된 한반도를 포함한 아시아 지역기상모형의 계산망에 대해 구축되어, 이 지역의 기상 및 수문 예측모의를 위한 다른 분포형모형들의 입력자료로도 사용이 가능하다.

임하 다목적댐 건설 후 주변지역 기후 및 작물생산력 변화 (Simulation of Local Climate and Crop Productivity in Andong after Multi-Purpose Dam Construction)

  • 윤진일;황재문;이순구
    • 한국작물학회지
    • /
    • 제42권5호
    • /
    • pp.579-596
    • /
    • 1997
  • 1990년 임하 다목적댐 건설에 의해 경북 안동지역에 생성된 담수면적 28.7$\textrm{km}^2$의 임하호가 주변지역의 국지기후 및 주요 작물의 잠재생산력에 미친 영향을 구명하기 위해 임하호 주변 $30km\times 25km$ 지역을 대상으로 무인기상관측망을 구성, 5년간의 특별관측을 수행하였다. 수집된 자료를 토대로 담수전후 기후시나리오를 작성하고 이를 작물모형에 입력하여 최종 건물생산량을 추정한 바, 주요 결과는 다음과 같다. 1. 담수후 5년간 일최고기온은 담수 전보다 평균적으로 한후기 (10월~3월)에 상승하고 난후기에 하강하였으나, 예외적으로 6월과 7월에는 상승하였다. 일최저기온은 담수 전보다 평균적으로 난후기(4월~8월)에 하강하고 한후기에 상승하였다. 담수 전후 기온의 변화정도는 겨울철에 크고 여름철에 적었다. 2. 담수후 5년간 강수량은 담수 전보다 평균적으로 2, 3, 5, 7, 12월에 증가하였고 나머지 달에는 감소하였으나 연간 총강수량의 변화는 인정되지 않았다. 월별 일사량은 2, 6, 9월을 제외하고는 담수전에 비해 5% 가량 감소하였다. 3. 담수 전후 30년간씩의 벼 생육모의실험에서 대상지역내 27개 재배구역 중 담수에 의해 잠재수량의 변화가 인정되는 곳은 한 곳 뿐으로 담수전에 비해 정조 기준 4%의 증가를 보였다. 4. 담수 전후 30년간씩의 콩 생육모의실험에서 대상지역내 27개 재배구역 중 담수에 의해 잠재수량 감소가 인정되는 곳이 2개였으며 최대 감수율은 16%였다. 5. 담수 전후 30년간씩의 옥수수 생육모의실험에서 담수에 의해 옥수수의 잠재수량 감소가 인정되는 곳이 총 27개 중 6개였고 최대 감수율은 17%였다.. 또한 유수의 크기는 전 유수발달기를 통하여 항상 밀양 2003가 고시히카리보다 컸다. the canopies with more leaf mass, making MB the highest, HB the lowest, and DS in between. Relative humidity was over 90% in the night and dropped to 70% in the mid-afternoon, but vapor pressure within the canopy was highest at around 13:00 LST. Dew point depression was lowest and, combined with the temperature, the relative humidity was highest in HB. Mean period of wetting duration was in the order of DS>HB>MB, while the dew point depression was greatest in DS.ANCOVA, Pearson correlation을 이용하여 분석하였으며, 그 결과는 다음과 같다. 캠프 프로그램은 소아 당뇨병 환자의 자기 효능을 증진시키고 환자 역할 행위 이행을 높여주는데 효과적 이었다. 소아 당뇨병 환자의 자기 효능은 환자 역할 행위 이행과 순 상관 관계가 있어, 자기 효능이 증진될수록 환자 역할 행위 이행 정도가 높아졌다. 무조건 사주지 않는다(8.0%), 무조건 사준다(3.1%)로 식품광고에 나오는 식품 요구시 부모의 70.3%가 거절하는 것으로 나타났다. 거절 이유는 건강에 나쁘다는 것이 가장 큰 이유였으며 강남과 강북 어린이간에 유의적인 차이가 있었다(p<0.001). TV

  • PDF

차광막를 이용한 하절기 콘크리트포장의 초기온도 관리 방안연구 (A Study for Controlling Early-age Temperature Rise of the Concrete Pavement by Shadow Tent in Hot Weather Construction)

  • 조영오;김형배;서영찬;안성순
    • 한국도로학회논문집
    • /
    • 제6권4호
    • /
    • pp.75-89
    • /
    • 2004
  • 콘크리트 포장의 장기 공용성은 시공조건과 환경조건에 크게 좌우된다. 즉 초기에 무작위 균열이나 균열틈이 많이 벌어진 경우 포장수명을 저감시키는 원인이 된다. 시공당시의 온도와 습도, 시멘트와 골재의 종류, 양생조건들은 콘크리트포장의 품질에 영향을 미치는 중요한 요소이다. 그 중에서도 대기온도와 수화열의 증가에 의한 높은 온도차이는 심각한 초기균열을 발생시키는 원인이 되는 것으로 알려져 있다. 본 연구에서는 차광막을 사용하여 콘크리트 슬래브의 온도를 제어하여 초기균열이 발생할 가능성을 낯추고 슬래브질이의 온도차이에 의해 발생되는 curling stress를 줄일 수 있었고, 강도에 있어서는 차광막 설치 구간이 일반시공구간보다 장기강도를 크게 할 수 있음을 확인하였다. 또한 콘크리트포장의 포설 후 72시간의 강도 및 응력을 예측하는 프로그램인 HIPERPAV를 사용하여 초기에 균열이 발생할 가능성을 비교해본 결과 차광막을 설치한 구간이 본 시험시공의 예에서 균열이 발생하지 않을 가능성(reliability)이 차광막을 설치하지 않은 구간(일반시공구간) 72.5%. 차광막설치 구간 95%로 나타나 차광막설치 구간이 차광막을 설치하지 않은 구간보다 균열이 발생하지 않을 가능성을 크게 증가시킬 수 있을 것으로 분석되었다.

  • PDF