• Title/Summary/Keyword: All Air

Search Result 3,835, Processing Time 0.03 seconds

Influence of Drought and High Temperature on the Physiological Response and Yield in Hot Pepper (토양 건조 스트레스와 기온상승에 의한 고추의 생리반응 및 생산량 변화)

  • Lee, Sang Gyu;Lee, Hee Ju;Kim, Sung Kyeom;Mun, Bo heum;Lee, Jin Hyoung;Lee, Hee Su;Do, Kyung Ran
    • Journal of Environmental Science International
    • /
    • v.27 no.4
    • /
    • pp.251-259
    • /
    • 2018
  • This study was conducted to determine the effects of combination of air temperature and soil water content on the growth, physiological disorder rate, and yield of hot peppers. The study was carried out in a typical plastic house (open on one side and with ventilation fans on the other side), which was maintained with gradient air temperature (maximum difference in air temperature: $6^{\circ}C$). The deficit irrigation (DI) treatment commenced 65 days after transplanting. The height of plant and fresh and dry weights of the stem increased at high air temperature (ambient + $6^{\circ}C$, extreme high temperature; EHT). Furthermore, the leaf area decreased significantly with the DI treatment. There were no significant differences in the stem diameter, number of branches, and fresh and dry weights of the leaves among all the treatments. The net photosynthesis rate of the full irrigation (FI) treatment was higher than that of the DI treatment. The photosynthesis rate at ambient air temperature was $19.7{\mu}mol\;CO_2m^{-2}{\cdot}s^{-1}$, the highest among all the treatments; however, the photosynthesis rate of the EHT treatment decreased by 60% ($12.3{\mu}mol\;CO_2m^{-2}{\cdot}s^{-1}$). Additionally, the formation of guard cells in the leaf was abnormal with the EHT treatment, and there was a decrease in translocation efficiency. The effects of air temperature treatment were more pronounced on the physiological disorder rate and yield. The physiological disorder rate of the EHT treatment was the highest under the DI treatment condition. The yield of the AFI (ambient air temperature with full irrigation) treatment was 3,771 kg/10a, the highest among all the treatments; however, the yield of the EHT treatment with DI and FI was 1,282 and 1,327 kg/10a, respectively. These results indicate that growth and physiological disorder rate improved with the EHT treatment; however, there was a decrease in yield. Furthermore, the formation of guard cells was abnormal and malfunctional.

A STUDY OF THE BOND STRENGTHS OF COMPOSITE RESIN TO DENTIN SURFACES PREPARED WITH MICROABRASIVE (Microabrasive로 처리한 상아질표면에 대한 복합레진의 결합강도에 관한 연구)

  • Choi, Kyoung-Kyu;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.61-75
    • /
    • 1997
  • The bond strengths of composite resin to tooth dentin vary with the methods of cavity preparation and surface treatment. Recent developments in techniques of dentinal surface treatment have renewed interest in microabrasive as a means of tooth preparation, The purpose of this study was to determine the effects of a new method of cavity preparation on the bond of composite resin to dentin. Freshly extracted 144 healthy human third molars were used in this study. The dentin surfaces prepared with #600 SiC abrasive paper were divided into control and air abrasion groups according to the method of dentin surface preparation using different combinations of delivery pressure, time, and acid etching. The shear bond strengths were measured after the composite resin (Clearfil Photo Bright) was bonded to prepared dentin surfaces by light-curing using a dentin bonding system (All-bond 2), In addition, the average surface roughness was measured to investigate the effect of differently prepared dentin surfaces on the shear bond strengths. The surface changes of prepared dentin and the debonded dentin surfaces were observed with SEM (S-2300, Hitachi Co., Japan). The following results from this-study were obtained ; 1. There was no significant difference of shear bond strengths according to the changes of delivery pressure and time. 2. The shear bond strengths were lower than the control in the air abraded-only groups, but those of the additional acid-etched groups were higher than the control. 3. The shear bond strengths to all air-abraded surfaces were increased by acid etching. 4. The correlation between shear bond strengths and surface roughness was not certain, although the mean surface roughness of all air-abraded surfaces has increased evidently while it has slightly decreased for additional acid etching. 5. On SEM examination, the dentinal tubules were almost occluded in the air abraded-only groups, but those were opened in the additional acid-etched groups. 6. The debonded surfaces were showed adhesive failure mode in the air abraded- only groups, while those were showed mainly the mixed and cohesive failure mode in the additional acid-etched groups. These results suggest that the layer produced during cavity preparation or surface treatment with air abrasion must be removed for maximum bond strength of composite resin to dentin.

  • PDF

Integrated Environment Impact Assessment of Brick Kiln using Environmental Performance Scores

  • Pokhrel, Rajib;Lee, Heekwan
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.15-24
    • /
    • 2014
  • The capital city of Himalayan Country Nepal, Kathmandu Valley is surrounded by consecutive high mountains, which limits the air distribution and mixing effects significantly. It in turn generates steady air flow pattern over a year except in monsoon season. The air shed in the Valley is easily trapped by the surrounded mountains and the inversion layer formulated as the cap. The $PM_{10}$ concentration was noticeably higher than the standard level (120 ${\mu}g/m^3$) in urban and suburban area of Kathmandu valley for all seasons except monsoon period. The Valley area experiences similar wind patterns (W, WWS, and S) for a year but the Easterly wind prevails only during the monsoon period. There was low and calm wind blows during the winter season. Because of this air flow structure, the air emission from various sources is accumulated within the valley air, high level of air pollution is frequently recorded with other air polluted cities over the world. In this Valley area, brick kilns are recognized as the major air pollution source followed by vehicles. Mostly Bull Trench Kiln (BKT), Hoffman Kiln and Vertical Shaft Brick Kiln (VSBK) are in operation for brick firing in Kathmandu valley where the fuels such as crushed coal, saw dust, and natural gas are used for processing bricks in this study. Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts (TRACI) was used for screening and quantifying the potential impacts of air emission from firing fuels. The total Environmental Performance Score (EPS) was estimated and the EPS of coal was approximately 2.5 times higher than those of natural gas and saw dust. It is concluded that the crushed coal has more negative impact to the environment and human health than other fuel sources. Concerning the human health and environment point of view, alternative environment friendly firing fuel need to be used for brick industry in the kiln and the air pollution control devices also need to be applied for minimizing the air emissions from the kilns.

Analysis of High Concentration Diffusion Pattern by Air Pollutions in Port Industry Interfaces

  • Je-Ho Hwang;Sang-Hyung Park;So-Hyun Yun;Si-Hyun Kim
    • Journal of Korea Trade
    • /
    • v.26 no.3
    • /
    • pp.117-136
    • /
    • 2022
  • Purpose - Port is vital for international trade accounting for approximately 80% of world cargo transportation in the global trade sector. Air pollutants emitted owing to the related industry interfaces developed around the port spread throughout the dense population region can have harmful effects on the nearby residents. This study aims to analyze high-concentration diffusion pattern by air pollutants, considering the main management periods by air pollutants. Design/methodology - Employing the concentration criteria per main air pollutant, the analyses of concentration change patterns per air pollutant, wind characteristics that directly affected the air pollutant diffusion, distribution types per air pollutant, and high-concentration diffusion patterns by season according to time changes were conducted. Findings - The substances that caused harmful levels of air pollution in the hinterland living zone of the Busan New Port were PM_10, PM_2.5, and NO_2. Furthermore, the intensive management periods were as follows: For PM_10, 24-h (spring), 12:00-16:00 (summer), 12:00-16:00 (summer), 20:00-12:00 (fall), and 24:00-20:00 (winter), and for PM_2.5, 24-h (all four seasons), and for NO_2, 23:00-04:00 (spring), 23:00-08:00 (summer), and 20:00-08:00 (fall), and 23:00-04:00 (winter). Originality/value - Research finding indicates that regular monitoring and countermeasures to reduce air pollution for each air pollutant makes it possible to achieve effective air quality control in the port and hinterland living zones.

Effect of moisture and drying time on the bond strength of the one-step self-etching adhesive system

  • Lee, Yoon;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.155-159
    • /
    • 2012
  • Objectives: To investigate the effect of dentin moisture degree and air-drying time on dentin-bond strength of two different one-step self-etching adhesive systems. Materials and Methods: Twenty-four human third molars were used for microtensile bond strength testing of G-Bond and Clearfil $S^3$ Bond. The dentin surface was either blot-dried or air-dried before applying these adhesive agents. After application of the adhesive agent, three different air drying times were evaluated: 1, 5, and 10 sec. Composite resin was build up to 4 mm thickness and light cured for 40 sec with 2 separate layers. Then the tooth was sectioned and trimmed to measure the microtensile bond strength using a universal testing machine. The measured bond strengths were analyzed with three-way ANOVA and regression analysis was done (p = 0.05). Results: All three factors, materials, dentin wetness and air drying time, showed significant effect on the microtensile bond strength. Clearfil $S^3$ Bond, dry dentin surface and 10 sec air drying time showed higher bond strength. Conclusions: Within the limitation of this experiment, air drying time after the application of the one-step self-etching adhesive agent was the most significant factor affecting the bond strength, followed by the material difference and dentin moisture before applying the adhesive agent.

Analysis of performance test results of CA-certified air cleaners from 2003 to 2015 (2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석)

  • Kim, Hak-Joon;Hong, Kee-Jung;Woo, Chang Gyu;Han, Bangwoo;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.

Air Monitoring of Persistent Organic Pollutants Using Passive Air Samplers (Passive Air Sampler를 이용한 잔류성 유기오염물질의 대기 모니터링)

  • Choi, Sung-Deuk;Chang, Yoon-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.5
    • /
    • pp.481-494
    • /
    • 2005
  • The monitoring of persistent organic pollutants (POPs) in the atmosphere is a basis for the study of the fate of POPs in multimedia environments. Recently, passive air samplers (PASs) for POPs have been developed. In this paper, we deal with the principle, properties, and applications of the PAS. The principle of PAS, which has no pump, is physical sorption of semi-volatile organic chemicals on various sorbent materials. The PAS is much smaller than a high-volume air sampler and does not need electricity. These properties of the PAS make it possible to conduct various-scaled environmental monitoring all over the world including the Arctic and Antarctic, but the major disadvantage of PAS is its long sampling periods up to 2 years. To date, four kinds of PAS have been developed: polyurethane foam (PUF), polymer-coated glass (POG), semi-permeable membrane devices (SPMDs), and XAD resin-based PAS. Among them, SPMDs have been commercialized and are most widely used now. Meanwhile, the POPs emitted from China have a large potential to influence the levels and fates of POPs in Korea. Since characteristics of PAS are quite useful to monitor long-range transport of POPs, the use of PAS is highly recommended.

The Effect of Surrounding Gas Flow on the Heat Transfer of the Falling Film Flowing Down the Outside of a Vertical Tube (수직원관 외부 유하액막 열전달에 주변 기체유동이 미치는 영향)

  • 권경민;정시영;김병주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.996-1003
    • /
    • 2002
  • Heat transfer characteristics were investigated for the falling film flowing down the outside of an electrically heated vertical tube. Water was used for the falling film, and its Reynolds number was varied in the range of 70~500. Because water is heated and evaporated as it flows down, both sensible and latent heat transfer should be considered. The effect of the surrounding air movement was investigated by changing the direction of the air injection; without air injection, parallel-flow, and counter-flow. For all cases, sensible teat transfer rate was almost linearly increased with the increasing film flow rate. It was found that the film heat transfer coefficient was hardly influenced by the parallel air flow. However, the counter-flow of air reduced the heat transfer coefficient, which might be caused by the uneven distribution or flooding of the film. At high heat flux, a sudden change of the film heat transfer coefficient was detected as the film flow rate reached the transition value. It is supposed that this phenomenon was caused by the change in the film flow pattern.

The Effects of Air-Pressure Cervical Traction Treatment on Forward Head Posture, ROM and Pain in the Tension Headache in the Adults (성인의 긴장성 두통에 에어견인요법이 앞쪽머리자세와 ROM 및 통증에 미치는 영향)

  • Cho, Namjeong;Lee, Soljae
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.4
    • /
    • pp.9-17
    • /
    • 2014
  • Purpose : The purpose of this study was to ascertain the effects of air-pressure cervical traction on the tension headache in the adults. Method : All subjects were treated with air-pressure cervical traction while 15 minutes a day, 3 times per week, for 4 weeks. The effects of air-pressure cervical traction were evaluated by HIT-6(headache impact test), VAS, and flexion, extension, left right flexion, left right rotation of cervical ROM. The measured data were analyzed by using repeated ANOVA. Especially in order to investigate the effect of air-pressure cervical traction. The comparison with among three measurement time. Results : The results of this study were as follows; 1) Prior and two weeks measurement did not show significant differences. The head forward posture than before the experiment, each experimental group was significantly increased(p<.05). 2) Prior and two weeks measurement did not show significant differences. The experimental group than ever cervical ROM of the movable range increased significantly(p<.05). 3) The experimental group was significantly lower than before the VAS(p<.05). 4) HIT score of the experimental group was significantly lower than before(p<.05). Conclusion : These findings suggest that air-pressure cervical traction had effect on the tension headache in the adults.

The influence on air quality of the surroundings by the facility of the district heating (집단 에너지 시설에 의한 주변 대기질 영향)

  • 연익준;주소영;이민희;손종렬;김광렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.18-25
    • /
    • 2002
  • The comparison of the air quality with the evaluation of the environmental assessment before and after operations of the heat source and of the flue-gas desulfurization facilities were studied. First of all, several sites were selected for the representative sample points, and then they were examined air quality of the surroundings. The results were that TSP(total suspended particulate) analysis after an operation of the heat source facility was $74~81{\mu}g/m^3$, PM-10 was $31~94{\mu}g/m^3$, and $SO_2$concentration was 0.002~0.009ppm, respectively. As the result of examination to the concentrations of diffused pollutants, there was no relations between TSP concentration of sample points and the effect of air quality according to the heating source. When we compared the neighbored area of the heating source with the other area, the concentration of air pollutants after an operation of the facility of the heating source was similar to the heating source, the neighbored area, and the other area. So we concluded that there was no the effect of the air pollution by producted pollutants from the heating source.