• Title/Summary/Keyword: Alkaline Solution

Search Result 719, Processing Time 0.027 seconds

High Temperature Characteristics of Commercially Available Anion Exchange Membrane for Alkaline Water Electrolysis (알칼리 수전해를 위한 상용 음이온교환막의 고온 특성)

  • JANG, SU-YOEN;RYU, CHEOL-HWI;HWANG, GAB-JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.330-336
    • /
    • 2022
  • In order to evaluate the possibility as a separator in alkaline water electrolysis, the high temperature characteristics were evaluated by measuring the membrane resistance and durability of 5 types of commercial anion exchange membranes in 7 M KOH solution and at 80℃. The membrane resistance of AEM membrane measured in 7 M KOH solution and at 80℃ had a lower value of about 8-24 times compared to the other membranes. The durability of AEM membrane tested with the soaking time in 7 M KOH solution and at 80℃ showed a very good stability and that of FAAM40 and FAAM75-PK showed secondly a good stability. The thermal stability with the soaking time in 7 M KOH solution and at 80℃ of FAAM40 and FAAM75-PK membrane analyzed by thermo-gravimetric analysis showed a good stability compared to the other membranes.

Measurement of the Corrosion Rate of Aluminum in Alkaline Solution (알칼리 용액에서 알루미늄의 부식속도 측정)

  • Shim Eun-Gi;Hwang Young-Gi;Chun Hai-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.3
    • /
    • pp.117-122
    • /
    • 1999
  • This study investigated the corrosion rate of aluminum in alkaline solution. It was performed to observe the effects of alloy element, alkalinity (KOH concentration), solution temperature, and inhibitor and its concentration in the solution. Among species of aluminum, AA-1050 showed the lowest corrosion rate due to its high purity $(>199\%)$, whereas alloys containing Mg anuor Mn were highly corroded, relatively. The corrosion rate could be reduced over than $50\%$ by saturating the solution with ZnO, while ZnAc did not work as an inhibitor. The inhibition effect of ZnO increased with increasing the alkalinity and solution temperature. It was found that the corrosion rate linearly increased with the concentration of KOH in first order and exponentially decreased with the inverse of the solution temperature. An analysis of the corroded material covered the surface of aluminum was made by SEM and EDS. According to the analytical results by using XRD, it was confirmed that $Al(OH)_3$ was produced from the corrosion of aluminum in KOH solution.

The Degradation of Indomethacin in Aqueous Solution (수용액에 있어서의 Indomethacin 분해)

  • 전인구;이민화;우종학
    • YAKHAK HOEJI
    • /
    • v.20 no.1
    • /
    • pp.76-82
    • /
    • 1976
  • The base-catalyzed hydrolysis of indomethacin over a range of pH 8,2 to 10.0 was investigated, according to the first order kinetic equation. The energy of activation for the reaction was calculated 20, 18 kcal/mole from the Arrhenius plot. And the optimal pH of indomethacin in aqueous solution was estimated as pH 4.93 by the extrapolation of the log k-pH profiles in strong acidic and alkaline regions. And the influences of alkaline earth metals, heavy metals and some other compounds on the degradation of indomethacin were observed with no effect.

  • PDF

Electro-oxidation of Cyclohexanol on a Copper Electrode Modified by Copper-dimethylglyoxime Complex Formed by Electrochemical Synthesis

  • Hasanzadeh, Mohammad.;Shadjou, Nasrin.;Saghatforoush, Lotfali.;Khalilzadeh, Balal.;Kazeman, Isa.
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.12
    • /
    • pp.2943-2948
    • /
    • 2009
  • Copper-dimethylglyoxime complex (CuDMG) modified Copper electrode (Cu/CuDMG) showed a catalytic activity towards cyclohexanol oxidation in NaOH solution. The modified electrode prepared by the dimethylglyoxime anodic deposition on Cu electrode in the solution contained 0.20 M $NH_4Cl\;+\;NH_4OH\;(pH\;9.50)\;and\;1\;{\times}\;10^{-4}$ M dimethylglyoxime. The modified electrode conditioned by potential recycling in a potential range of -900${\sim}$900 mV vs. Ag/AgCl by cyclic voltammetry in alkaline medium (1 M NaOH). The results show that the CuDMG film on the electrode behaves as an efficient catalyst for the electro-oxidation of cyclohexanol in alkaline medium via Cu (III) species formed on the electrode.

Mechanism of change in compressive strength of geopolymers by immersion method (침지방법에 따른 지오폴리머의 압축강도 변화 메커니즘)

  • Kim, Hakmin;Kim, Yootaek
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.2
    • /
    • pp.68-76
    • /
    • 2022
  • This study was performed to investigate the mechanism of the change in compressive strength of autoclave cured geopolymers. Specimens were immerged in distilled water, 2M, 8M, and 14M alkaline solutions for 3, 7, and 21 days. The change in the specimens immersed in a short period of time was not significant, but the compressive strength of the specimens immersed in the distilled water and 8M alkali solution) for 21 days increased more than twice as much as before immersion because of additional geopolymerization. However, compressive strength decreased due to the alkaline aggregate reaction when alkaline solution was supplied more than a certain level of concentration. Therefore, immersing the specimens for more than 21 days in the distilled water or 8M alkaline solution would be desirable for the improvement of compressive strength of autoclave cured specimens.

Antimicrobial and Other Properties of a New Stabilized Alkaline Glutaraldehyde Disinfectant/Sterilizer (병원에서 사용하는 수술도구 살균제, glutaraldehyde 용액의 살균 효과에 관하여)

  • 궁리환
    • YAKHAK HOEJI
    • /
    • v.31 no.4
    • /
    • pp.236-251
    • /
    • 1987
  • The chemistry, antimicrobial properties, organic soil resistance, toxicity, corrosivity and chemical stability of stabilized alkaline 2%, glutaraldehyde solution(SGS) are discussed. SGS retains the maximum antimicrobial activity of alkaline glutaraldehyde solutions and the chemical stability here to fore observed only with acidic glutaraldehyde solutions. These improvements, along with the inherent resistance of glutaradehyde to neutralization by organic soil, allow SGS to be continuously used for 14 days in situations of high dilution, or 28 days in situations of low dilution.

  • PDF

Adsorption Characteristics of Alkaline Copper Quat Preservative Components in Wood (구리⋅알킬암모늄화합물계 목재방부제 (ACQ) 유효성분의 목재 흡착 특성)

  • Lee, Jong-Shin;Choi, Gwang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.491-498
    • /
    • 2014
  • In order to obtain basic data for concentration control of alkaline copper quat (ACQ) solution in wood preservative treatment, this study investigates the change of concentration and adsorption of treating solution and active ingredient, copper oxide (CuO) and didecyldimethyl ammonium chloride (DDAC), in the process of recycling of ACQ solution. Japanese larch (Larix leptolepis), Douglas-fir (Psedotsuga menziesii) and Radiata pine (Pinus radiata) were treated with ACQ solution. The active ingredient concentration of ACQ solution was decreased continuously with increase of recycling. There are differences between extent of concentration decrease of Cu (as CuO) and DDAC. DDAC was decreased more quickly and to a higher degree than Cu for all recycling. The extent of DDAC concentration decrease was remarkable than that of Cu for wood species. The amount of DDAC adsorbed into wood decreased with the increase of ACQ solution recycling, but adsorption of Cu was little difference regardless of recycling. The adsorption of Cu into wood increased as DDAC concentration decrease by recycling of ACQ solution. This is likely due to decrease of DDAC competition with Cu for the same reaction site in wood.

Magnetite film on iron (강재의 마그네타이트 피복에 관한 연구)

  • Kim, H. G.;Kang, T.
    • Journal of the Korean institute of surface engineering
    • /
    • v.25 no.2
    • /
    • pp.66-72
    • /
    • 1992
  • Magnetite film on iron surface could be coated in strongly alkaline solution (12M NaH\OH) which contained additives such as NaHCO3, KCl and NaNO2, Iron plate was immersed in boiling solution ($130^{\circ}C$) contained above mentioned additives for 1 hour. There are some microcracks and these cracks proved to be the sites for the initiation of corrosion when immersed in 3% NaCl solution. To improve corrosion resistance of the coated steel plate, chromating was done as a post treatment. Chromate film was formed on magnetite oxide film potentiostatically at-918mV/SCE for five minutes at temperature of $70^{\circ}C$ in the alkaline solution containing 5g/l Na2Cr2O7.2H2O.Cr3O4 was electrodeposited on magnetite oxide film and Cr2O3 was electrodeposited on iron surface which was assumed as surface revealed due to microcracks. Increased corrosion resistance of chromated magnetite oxide film was proved in salt spray test & immersion test.

  • PDF

Development of Microfluidic Polydiacetylene Sensor Chip for pH detection (pH 검출을 위한 미세유동 폴리디아세틸렌 센서칩 개발)

  • Hwang, Hyun-Jin;Song, Si-Mon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2415-2418
    • /
    • 2008
  • Polydiacetylenes (PDAs) are very attractive chemical substances which have distinctive features of color change and fluorescence emission by thermal or chemical stress. Especially, when PDAs contact with solutions of a particular pH, such as a strong alkaline sodium hydroxide (NaOH) solution or a strong acidic hydrogen chloride (HCl) solution, PDAs change their color from non-fluorescent blue to fluorescent red. In this study, we propose a novel method to detect alkaline pH using PDAs and NaOH solutions by hydrodynamic focusing on a microfluidic chip. Preliminary results indicate that the fluorescent intensity of PDAs increases in respond to the NaOH solution concentrations. Also, the fluorescence is quenched back when the PDAs are in contact with a HCl solution. These results are useful in a microfluidic PDA sensor chip design for pH detection.

  • PDF

Anti-Corrosion Characteristics of WC-based Alloy Coatings Fabricated by HVOF Process - Polarization Characteristics in Alkaline Solution - (HVOF 용사법에 의해 제조된 WC계 합금 코팅층의 방식특성(II) - 알칼리 용액에서의 분극특성 -)

  • Kim, Tae-Yong;Kim, Yeong-Sik;Kim, Jae-Dong
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.40-44
    • /
    • 2014
  • The purpose of this paper is to investigate polarization characteristics of WC-based alloy coatings in alkaline solution. The coatings were fabricated with WC-CrC-Ni, WC-Co-Cr and WC-Co composite powders by HVOF process. Corrosion tests of coatings and substrate were carried out using potentiostat/galvanostat at solution with pH 8 and pH 13. Corrosion potential(Ecorr) and corrosion current density(Icorr) could be studied from polarization curve, and corrosion behavior was analyzed by SEM and EDS. WC-Co-Cr coating and WC-CrC-Ni coating showed more favorable anti-corrosion characteristics than WC-Co coating and substrate at solution with pH 8 and pH 13.