• Title/Summary/Keyword: Alignment degree

Search Result 195, Processing Time 0.028 seconds

PVA Technology for High Performance LCD Monitors

  • Kim, Kyung-Hyun;Song, Jang-Geun;Park, Seung-Bam;Lyu, Jae-Jin;Souk, Jun-Hyung;Lee, Khe-Hyun
    • Journal of Information Display
    • /
    • v.1 no.1
    • /
    • pp.3-8
    • /
    • 2000
  • We have developed a high performance vertical alignment TFT-LCD (Thin Film Transistor Liquid Crystal Display), that shows a high light transmittance, and wide viewing angle characteristics with an unusually high contrast ratio. In order to optimize the electro-optical properties we have studied the effect of cell parameters, multi-domain structure and retardation film compensation. With the optimized cell parameters and process conditions, we have achieved a 24" wide UXGA TFTLCD monitor (16:10 aspect ratio 1920X1200) showing a contrast ratio of over 500:1, panel transmittance near 4.5%, response time near 25 ms, and viewing angle higher than 80 degree in all directions.

  • PDF

A Case Report on Postpartum Pelvic Pain Applied Chuna Treatment (추나 요법을 적용한 산후 골반통 환자의 경과관찰 1례)

  • Lee, Jin-Bok;Im, Jeong-Gyun;Lee, Hyung-Geo;Jeong, Si-Yeong
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.1
    • /
    • pp.11-17
    • /
    • 2011
  • A 28-year-old woman presented with postpartum pelvic pain. The patient complained severe pain and couldn't walk at all a week after natal. Computed tomography and plain radiography of the pelvis didn't reveal abnormal condition except asymmetrical alignment. Chuna treatment isn't usually applicable to the patient after natal. But we tried Chuna treatment to adjust the asymmetrical alignment of pelvis by half degree of strength. The pelvic pain improved considerably after 2 weeks treatment, so we report this case to emphasize the role of Chuna treatment in the management of postpartum pelvic pain.

  • PDF

Fabrication of Porous Materials having an Anisotropic Thermal Conductivity through the Alignment of Plate-shaped Pores (배향된 판상 기공구조를 통해 열전도도 이방성을 갖는 다공질 재료의 제조)

  • Yun, Jung-Yeol;Song, In-Hyeok;Kim, Hae-Du
    • 연구논문집
    • /
    • s.33
    • /
    • pp.147-155
    • /
    • 2003
  • In order to fabricate porous materials having an anisotropic thermal conductivity by aligning plate-shaped pores structure, alumina powder (AM-21, mean particle size $4\mum$) and flake crystalline graphite was used. The aligned pore structure was realized using multi-pressing process. Degree of pore orientation increased with the number of pressing and thermal conductivity, parallel to the pressing direction, decreased with the number of pressing. Thermal conductivity decreased significantly to the addition of 30vol% crystalline graphite, however, in the case of 60vol%, thermal conductivity did not decrease significantly due to the breakage of crystalline graphite. An anisotropy of the thermal conductivity increased with the content of crystalline graphite up to 30vol%. Graded pore structure was fabricated by controlling the content and size of crystalline graphite, which provides, possibly, the enhancement in mechanical strength and thermal insulation properties of the insulating bricks.

  • PDF

Variation of Magnetic Properties of (Nd, Dy)-Fe-B Sintered Magnets with Compaction Conditions ((Nd, Dy)-Fe-B 소결자석의 성형조건에 따른 자기특성 변화)

  • NamKung, S.;Lee, M.W.;Han, S.J.;Jang, T.S.
    • Journal of Powder Materials
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2012
  • In order to improve the remanence of (Nd, Dy)-Fe-B sintered magnets, we investigated the influence of compaction conditions such as packing density, applied field and green density on the magnetic properties. While the remanence decreased with increasing the packing density and green density, it increased with the increase of the applied field. In addition, XRD analysis revealed that the remanence was enhanced as the degree of powder alignment was improved. The green density was more influential on the remanence than the packing density and applied field.

The alignment of Sr-ferrite magnetic powder in anisotropic Sr-ferrite/resin-bonded magnets (이방성 Sr-페라이트/ 레진본드 영구자석에서 Sr-페라이트 자성분말의 방향성)

  • 정원용;조태식;문탁진
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.3
    • /
    • pp.219-225
    • /
    • 1994
  • The alignment of Sr-ferrite magnetic powders, which is usually related to the fluidity and the applied magnetic field, is investicated in the anisotropic Sr-ferrite / resin-bonded permanent magnets. The magnetic powder alignment is observed to increase with the applied magnetic field and the fluidity which is a function of molding temperature and powder packing ratio. The best magnetic powder alignment is achieved at the following conditions; Sr-ferrite packing ratio of 56vol%, apparent viscosity of about 3000 poise in $1000sec^{-1}$ shear rate, and applied magnetic field of about 5kOe. The degree of preferred orientation of the magnetic powders in the field direction, as determined by the dc hysterisis graphs, is 84~85% (0.84~0.85). This result is in agreement with the value of 0.85 obtained by the X-ray experiments in the $2{\theta}$ range of ${23~40}^0$. The best magnetic properties obtained are:2.2kG of remanent flux density, 2.2MGOe of maximum energy product.

  • PDF

The Analysis of Road Alignement and Construction GSIS Using RTK GPS and TS (RTK-GPS와 TS를 이용한 도로선형분석 및 GSIS 구축)

  • 장상규;홍순헌;김가야
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.4
    • /
    • pp.293-299
    • /
    • 2003
  • In the future, the design of road should be convenient in using of high-technology information and it needs the design of alignment that is able to make the maximum vehicles inducement function appropriated for CNS(Car Navigation System). So it needs to analysis appropriately the alignment of road for the improvement design of road which is established and to make the design of road and the coordinate of the main points. Therefore, this research had acquired the road data by RTK-GPS to accurate the analysis of road alignment and compared with Total Station. As the result, we could acquire the design source of the road alignment using RTK-GPS. Also, it was estimated the accuracy after comparing the design with RTK-GPS coordinates. We made an analysis of the degree of slant or the ups and downs of surface. We made an analysis of three dimensional visual information which was included in GSIS concept and estimated the accuracy. Finally, we analyzed the earth volume calculation by comparing with Total Station.

A Comparison of the Contact Areas between Cornea and RGP Lenses by Fitting Status (피팅 상태에 따른 RGP 렌즈와 각막과의 간극 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.255-264
    • /
    • 2012
  • Purpose: In this study, the effect of lens fitting status on the contact area between spherical/aspherical RGP lens and the cornea having different astigmatic degree and corneal type was investigated for guiding the proper selection of RGP lens. Methods: Spherical and aspherical RGP lenses were applied on ninety eyes $(25.12{\pm}3.52years)$ having with-the-rule astigmatism by different fitting status. Then, their central, mid-peripheral and peripheral areas of fluorescein pattern were calculated and compared for the quantitative evaluation of the contact area between spherical/aspherical RGP lens. Results: The central and peripheral areas with the alignment fitting was significant different based on lens design. However, the central area didn't show any significant difference by lens design and corneal type when fitted in steep or flat. When analyzed by the corneal shape, both lenses with alignment and flat fitting had significant difference in central and peripheral areas. However, the central, mid-peripheral and peripheral areas with steep fitting didn't show the difference by corneal types. When analyzed by the astigmatic degree, the central and peripheral areas with alignment fitting changed proportionally to the increase of corneal astigmatism regardless of corneal shape. With steep and flat fitting, however, the central, mid-peripheral and/or peripheral areas in round- and symmetric bowtie-typed corneas showed the conflicting result when compared to those of alignment fitting when analyzed by the astigmatic degree. Conclusions: In this study, it was confirmed that the contact areas of cornea and RGP lens fitted steep and flat status were largely affected by the corneal type and corneal astigmatism rather than RGP lens fitted in alignment status. Also, this result commonly occurred in both spherical and aspherical RGP lenses.

Designed tire wear and uneven wear determination system using only tire laser sensor (타이어 전용 레이저 센서를 이용한 타이어 마모도 및 편마모 판별 시스템 설계)

  • baek, Sung-hyun;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.346-349
    • /
    • 2015
  • Generally, in order to verify the degree of tire wear or abnormal wear, a driver or an auto mechanic checks the degree of tire wear and the existence of tire abnormality, directly with the naked eye or by way of using a gauge equipment. In case of such verification, individual subjective judgments may be involved or a driver may suffer heavy burdens to expend the time and cost for using the wheel alignment equipment. Therefore, this thesis will use a number of laser sensors to check the existence of abnormal wear and the degree of wear on each tire and develop a system checking the sides of tires to receive the tire information, so that subjective judgments may be overcome and objective and accurate judgments may be rendered.

  • PDF

Two-way Viewing Angle Switchable LCD with Two-Domain VA Structure

  • Preman, Smarty P.;Chen, Chao Ping;Yoon, Tae-Hoon;Kim, Jae-Chang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.898-899
    • /
    • 2008
  • In this paper we propose a new method for obtaining two way switchable LCD. For this two domain vertical alignment LCD is used. A two way LCD is able to show different images on the same screen based on left and right perspectives. Viewing angle dependence of different grey levels of transmittance for the polar angles 0, +45 and -45 degree are also found out.

  • PDF

Development of Polarization Controlled Micro Transmittance Profiler

  • An, Sung-Hyuck;Kim, Sang-Jun;Kim, Sang-Youl
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.998-1000
    • /
    • 2005
  • We report the development of the equipment that can measure the transmittance of the polarizer for TFTLCD application versus azimuth angle of the linear polarization at each micro spot in the section, and therefore measure the degree of iodine permeation and alignment quantitatively at each area of the section.

  • PDF