• 제목/요약/키워드: Airtight

검색결과 130건 처리시간 0.027초

고도수처리 환경에 노출된 에폭시 수지계 방수/방식재의 침식 저항성 평가에 관한 실험적 연구 (An Experimental Study on the Deteriorative Resistance of Epoxy Resin Waterproofing Phase under Advanced Water and Wastewater Treatment)

  • 오상근;장성주;김영삼;양승도
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술.기술논문발표회
    • /
    • pp.59-62
    • /
    • 2002
  • Recently, advanced system for water and wastewater treatment is introduced and operated because of water pollution and etc. One of this System makes use of O3(Ozone) for water and wastewater treatment. In airtight concrete structure, waterproofing phase as well as water are affected by strong oxidative O3 in the long-term. For this reason, material stability against O3 is examined. Consequently, the purpose of this study is to find out material stability an object of epoxy resin by way of accelerated O3 testing.

  • PDF

수목즙액 추출을 위한 무용매 간접탄화 증숙법 연구 (Study on the Wood Undiluted Solution Extract by the Streaming System)

  • 김경철;김창용
    • 동의생리병리학회지
    • /
    • 제17권6호
    • /
    • pp.1409-1411
    • /
    • 2003
  • The indirect carbonization without solvent for the extraction of the natural undiluted solution has been studied. The following results have been obtained. 1. The traditional wood undiluted solution distillation can be embodied with the indirect carbonization without solvent of the airtight space. The system of the indirect carbonization without solvent is the indirect dry distillation apparatus. It is composed of the high-temperature stove, the exterior can, material bag, interior can, collect water can and air-fan.

실험실 실험을 통한 창의 차음성능 개선에 관한 연구 (A Study on the Enhancement of the Sound Insulation Performance of Windows through the Laboratory Tests)

  • 김선우;정진연;이옥균;장현충;박현구;송혁
    • 소음진동
    • /
    • 제11권2호
    • /
    • pp.307-314
    • /
    • 2001
  • This study aims to provide fundamental data for enhancing the sound insulation performance of windows. For this study, windows composed of various types and thicknesses, were classified into five categories; fixed, single, double, triple and airtight, and then tested. In order to analyze their sound insulation characteristics and performances. test results were rated using methods such as D, STC, Ts and arithmetical mean. It was found that the sound insulation performance of windows is affected due to their type rather than the thickness of the glass. It was also found that when gap between the inner and outer frames was filled with caulking material, the sound transmission loss at high frequency bands was greatly improved. Therefore, the sound insulation performance of windows would be enhanced by minimizing the gap between frames.

  • PDF

최적반력을 가지는 도어 씨일의 단면설계 (Design of Door Seal Section with Optimal Reaction Force)

  • 한근조;박영철;심재준
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.165-175
    • /
    • 2000
  • In order to improve the function of a door seal, its section design technique is discussed in this study, Its roles are prevention of an inflow of dusts, noise interception, insulation, wateproof, and the vibroisolating action which reduces vibration between the body and the door of a car while running, and the buffer action which sustain the proper reacting force as the door is closed. In this study, the optimal cross section of a door seal is designed using nonlinear finite element analysis (commercial finete element analysis program EASi-SEAL) and tables of orthogonal arralys with respect to relations between door and door seal to secure the satisfactory airtight property with the minimum force to shut the door.

  • PDF

가스절연 원통형 관로 내의 스페이서 전계 최적화 알고리즘에 관한 연구 (Investigation on Electric Field Optimization Algorithm of Spacer in Gas Insulated System)

  • 김웅식;민석원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권3호
    • /
    • pp.115-120
    • /
    • 2002
  • This Paper describes an algorithm for the design of axi-symmetrical spacer under specified field conditions. The electric field alas been calculated by combination method of Integral Equation Method(IEM) and Charge Simulation Method(CSM). The contour of spacer is represented with NURB(Non-Uniform Rational B-spline) curve of which effectiveness has been proved. This algorithm introduces a design process in the aspect of electrical field, when a spacer in airtight cylinder is designed. Also various field conditions for obtaining optical shapes have been proposed. Due to the algorithm, the entire process shows a stable convergence. Both tangential and total electrical field are taken into consideration as specified field criteria.

Al-Zn-Si 3원계 합금도금강판의 부식거동에 관한 연구 (A Study on the Corrosion Behavior by the Moisture on the Surface Layer of the Al-Zn-Si ternary alloys)

  • 김영호;이상래;정원섭
    • 한국표면공학회지
    • /
    • 제34권3호
    • /
    • pp.187-194
    • /
    • 2001
  • Galvalume sheet steel was developed recently, and is used widely in several fields. It has and had a good corrosion resistance in open atmosphere, but it has week corrosion resistance in the ambient surroundings of an airtight packing. Therefore, black patina was synthesized on the surface of Galvalume sheet steel. Corrosion by moisture on a Galvalume surface begins from edge of a droplet and proceeds to the center of droplet. It begins mainly on the interdendritic structure instead of dendritic structure. This suggests that corrosion by moisture occurs on the Zn shrinkage hole from rapid air cooling. In addition, the initial corrosion occurs by the local cell and continues by the oxygen concentration cell.

  • PDF

공동주택에서의 창호성능에 따른 건물에너지 효율등급 평가 연구 (A Study on the Evaluation of Building Energy Rating considering the Insulation performance of the Window in Apartment houses)

  • 김치훈;안병립;홍성희;장철용
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.291-295
    • /
    • 2009
  • As a reasonable energy policy has become required because of consuming substantial amounts of oil than others, the studies on energy consumption are in work for energy savings of buildings that spend up to 24% of total energy consumption. However, there aren't basic data on energy consumption and installationregulations for effective equipments in energy guzzled buildings. The best plan to reduce the building energy consumption is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. Thus, we should prepare the alternatives to improve insulation performance of envelopes and the efficiency of insulation performance of the window for reducing energy consumption.

  • PDF

철도차량용 공기청정시스템 개발 (Development of Amenity-oriented Air Cleaning System for Railroad Passenger Cabin)

  • 박덕신;조영민;권순박;박은영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1288-1292
    • /
    • 2007
  • Because the indoor spaces of the passenger cabin is generally airtight to secure the safety of passengers and enhance the efficiency of the cabin air conditioning performances, the contamination pattern of them are largely similar to that of general indoor spaces. Therefore, continuous supply of outdoor air is required to keep the amenity of indoor space. Heating, ventilation, and air-conditioning (HVAC) system is composed of air cleaning filter, heater and air conditioned, blower and ducts. To achieve the clean indoor environment, an integrated control of each HVAC equipment are required. In this study, we developed the air cleaning system to enhance the amenity of the railroad passenger cabin.

  • PDF

건축물 외부 중공벽의 시공방안에 관한 연구 - 외부 점토벽돌의 사용을 중심으로 - (A study on the technical details of masonry veneer and cavity walls - Focused on the out wyth of clay bricks -)

  • 양순갑
    • 한국주거학회논문집
    • /
    • 제8권3호
    • /
    • pp.219-230
    • /
    • 1997
  • Lack of technical standards, specification and inadequate execution in masonry wall construction in Korea lead to produce serious flaw problems such as crack, efflorescene, and upset etc.. The purpose of this paper is to present the practical details for Masonry cavity wall construction to prevent rain penetration and to accommodate differential movement between the inner and outer wythes of cavity walls. Considering rain penetration and differential movement of both wythes of cavity walls, provision of an adequate air space, an airtight back-up wall, clean cavity with weepholes and vents, properly positioned flashing, tie and shelf angle etc. depend on the cavity wall types will help ensure good performance. The present details included noncorrosive hot dip galvanized steel or stainless steel for metal components, plastic and ultra violet resistant polypropylene Copolymer for other components was taken into account the construction method and several types of cavity walls in Korea

  • PDF

변압기 사고 검출을 위한 진동신호 연구 (A Study on the Vibration Signal for Detection of Power Transformer Failure)

  • 김현식;강창구;정찬수;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.493-495
    • /
    • 1995
  • Recently, as power transformer capacity is getting larger, vibration noise of transformer would be large and unexpected failuare of transformer give enormous economic loses, So we aquaire vibration signal, which is maked from transformer windings, core that are airtight out box with in insulation oil, and out box. Also we are fixed rated voltage and changing load current, analyize frequency domain of each vibration signals.

  • PDF