• Title/Summary/Keyword: Airflow Distribution

Search Result 105, Processing Time 0.028 seconds

A Study on the Effect of the Shape of the Exhaust Port on the Flow and Temperature Distribution in the Drying Part of the MRG(Mechanical Rubber Goods) Reinforcing Yarn Manufacturing System (MRG(Mechanical Rubber Goods) 보강사 제조시스템의 건조부에서의 배기구 형상이 유동 및 온도 분포에 미치는 영향에 관한 연구)

  • Kim, Hwan Kuk;Kwon, Hye In;Do, Kyu Hoi
    • Textile Coloration and Finishing
    • /
    • v.34 no.2
    • /
    • pp.109-116
    • /
    • 2022
  • Tire codes are made of materials such as hemp, cotton, rayon, nylon, steel, polyester, glass, and aramid are fiber reinforcement materials that go inside rubber to increase durability, driveability, and stability of vehicle tires. The reinforcement of the tire cord may construct a composite material using tires such as automobiles, trucks, aircraft, bicycles, and fibrous materials such as electric belts and hoses as reinforcement materials. Therefore, it is essential to ensure that the adhesive force between the rubber and the reinforced fiber exhibits the desired physical properties in the rubber composite material made of a rubber matrix with reinforced fibers. This study is a study on the heat treatment conditions for improving the adhesion strength of the tire cord and the reinforced fiber for tires. The core technology of the drying process is a uniform drying technology, which has a great influence on the quality of the reinforcement. Therefore, the uniform airflow distribution is determined by the geometry and operating conditions of the dryer. Therefore, this study carried out a numerical analysis of the shape of a drying nozzle for improving the performance of hot air drying in a dryer used for drying the coated reinforced fibers. In addition, the flow characteristics were examined through numerical analysis of the study on the change in the shape of the chamber affecting drying.

A Study on the Trends of Virtual Reality Application Technology for Agricultural Education (가상현실 응용기술의 동향 분석을 통한 국내 시설농업의 교육용 가상현실 활용방안 고찰)

  • Kim, Jun-Gyu;Lee, In-bok;Yoon, Kwang-Sik;Ha, Tae-hwan;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sang-yeon
    • Journal of Bio-Environment Control
    • /
    • v.27 no.2
    • /
    • pp.147-157
    • /
    • 2018
  • With the rapid development of the 4th industrial revolution, the large-sized facilities of agriculture have been developed with high-technologies. However, it is difficult to maintain the optimum environment in large-sized facilities. Although it is essential to control micro-climate properly in large-sized facilities, there are a lot of problems to utilize high-technologies and equipment because of insufficient education for farmers. Most farms have limitations to access to their farm because of prevention of epidemics, exposure of management know-how, and so on. Especially, it is difficult to understand internal environmental factors (airflow, temperature, humidity, etc.) for farmers because these factors are invisible. Recently, Virtual reality technology which allows users to experience various phenomena directly is attracting attention. Virtual reality is very useful technology to visualize airflow and temperature distribution and so on. However, there is no cases applied this technology to agricultural facilities. In this study, research trends of virtual reality in various fields were investigated. In particular, the limitation and possibility of virtual reality technology were analyzed for educating farmers. Finally, the development of virtual reality contents for smart-farm facility were suggested.

Nocturnal temperature distribution on orange orchards in Cheju Island (II) (제주도 감귤 과수원의 야간 기온 분포(II))

  • ;;Lee, Seung-Ho;Lee, Hyong-Young
    • Journal of the Korean Geographical Society
    • /
    • v.30 no.3
    • /
    • pp.230-241
    • /
    • 1995
  • The Characteristics of nocturnal temperature fields were analyzed to understand the factors of freezing-and-cold damages on orange orchards in Cheju Island. Temperatures were measured from January 7th through 27, 1995 at 25 sites in an area of 1x1.25$ extrm{km}^2$, Wasan-ri, Chochon-up, Pukcheju-kun located on the northeastern slope of Mt.Hanla. Several other weather elements such as wind and cloud were observed as supplementary data. Surface weather maps were also analyzed to clarify the influence of prevailing pressure patterns on the temperature fields. The vertical temperature profiles were obtained at the height from the ground up to 360 cm in 30 cm intervals at site 3, a frost hollow, and site 10 on the upper slope. The results show that freezing damages occured in the hollows, terrain depressions, rather than at the upper slope due to nocturnal radiation cooling as well as accumulation of cold airflow from Mt.Hanla. Windbreaks of densely planted Japanese ceders with stone-walls also roled as obstacles to the cold airflow in nights with Clear skies and light winds. The maximum intensity of temperature inversion in hollows, quasi-cold air lake, was 3.1$^{\circ}C$. Cold air from Mt.Hanla was trapped in the depressions up to a height of 90cm forming frost pocket. Man-made facilities such as shelterbelt or stone-wall which are built to prevent the penetration of cold north-westeries in winter aggravated the cold damage. The differance of daily minimum temperatures between before and behind shelterbelts was 2.$0^{\circ}C$. The man-made convection by smudgin which raised the temperatures up to 3.8$^{\circ}C$ can reduce the cold damage in the hellows.

  • PDF

Identification of the Sectional Distribution of Sound Source in a Wide Duct (넓은 덕트 단면내의 음원 분포 규명)

  • Heo, Yong-Ho;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.87-93
    • /
    • 2014
  • If one identifies the detailed distribution of pressure and axial velocity at a source plane, the position and strength of major noise sources can be known, and the propagation characteristics in axial direction can be well understood to be used for the low noise design. Conventional techniques are usually limited in considering the constant source characteristics specified on the whole source surface; then, the source activity cannot be known in detail. In this work, a method to estimate the pressure and velocity field distribution on the source surface with high spatial resolution is studied. The matrix formulation including the evanescent modes is given, and the nearfield measurement method is proposed. Validation experiment is conducted on a wide duct system, at which a part of the source plane is excited by an acoustic driver in the absence of airflow. Increasing the number of evanescent modes, the prediction of pressure spectrum becomes further precise, and it has less than -25 dB error with 26 converged evanescent modes within the Helmholtz number range of interest. By using the converged modal amplitudes, the source parameter distribution is restored, and the position of the driver is clearly identified at kR = 1. By applying the regularization technique to the restored result, the unphysical minor peaks at the source plane can be effectively suppressed with the filtering of the over-estimated pure radial modes.

Evaluation of characteristics for microbubble generation according to venturi nozzle specification (벤튜리 노즐 제원에 따른 마이크로버블 발생 특성 평가)

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6397-6402
    • /
    • 2015
  • This research was performed to review operating parameters, optimum condition and check characteristic of microbubble generation for using bubble size distribution according to venturi specification. Optimum operating condition have airflow rate 0.3 LPM, 3 bar(pressure tank) and connecting nozzle directly(without valve), it is advantageous to generate microbubble. In case of characteristic of microbubble generation according to venturi specification, effect that nozzle specification affects bubble size distribution is low impact. But considering performance aspects, when using nozzle that throat diameter 3-4 mm, $D_{50}$ are $54.98-61.19{\mu}m$(D3L15, D4L15), fraction of bubble less than $50{\mu}m$ are 0.326, 0.345. And it is superior to others. Besides, $D_{50}$ and fraction of bubble less than $50{\mu}m$ of throat length 20 mm are $49.40-54.98{\mu}m$, 0.447, respectively And nozzle that throat length 20 mm is relatively tendency to generate microbubble stably.

Aerodynamic Effects of Gun Gas on the Aircraft's Armament System (항공기 무장시스템 Gun Gas 공력특성에 관한 연구)

  • Choi, Hyoung Jun;Kim, Seung Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.623-629
    • /
    • 2020
  • This study examined the airflow field around a gun port on the flight condition of gunfire to verify the aircraft performance and safety effects and gun gas rate, path according to the options of diverter configuration. The gun port diverter not only effectively lowered the heat generated by gunfire but also effectively discharged the gun gas upwards. The path of gun gas can be changed according to its configuration. According to the optional configuration of the rear-gun-port diverter, the flow rate, path, and pressure of the gun gas were analyzed during gunfire. An analysis of the internal velocity distribution and the temperature change of the gun port revealed a rapid decrease in flow rate through the rear diverter according to the option configuration. The forward flow rate showed a similar tendency with little change. This ensures that the gun gas generated during gunfire has a sufficient flow distance from the aircraft surface, regardless of the rear gun port diverter's optional configuration. The flow stagnation of gun gas according to the option configuration of diverter had a great influence on the internal temperature rise of a gun port.

Estimation of Air Flow Rate in Automotive Ventilated Seat (자동차 통풍 시트의 유량 평가)

  • Lee, Hyun-Hee;Kim, Tae-Kyung;Lee, Kwangju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.34-40
    • /
    • 2016
  • In ventilated seats for cars, air flow is generated by a fan and passed through a foam pad, foam filter, and seat cover. There is a significant loss of air flow in this process, and it is not easy to analyze the amount delivered to the driver. Another difficulty is the geometric complexity of the air flow passage inside the seats. In this paper, the air flow through a foam pad was analyzed. Proper modeling of the bumps in the ventilation mat was found to be important in the analysis. Air flow is lost when it passes through the porous pad foam, which was measured and used to correct the analysis results. The corrected analysis results were in a good agreement with the experimental results. The amount of air flow delivered to a driver was measured using an airflow cone. Only 35.7% of the air flow from the fan was delivered.

Study on Indoor Flow According to Vane Angle of Square Ceiling Type Louver Diffuser (사각 천장형 루버 디퓨저의 토출 각도에 따른 실내유동에 관한 연구)

  • Jang, Heon-Deock;Lee, Dae-Hui;Lee, Jin-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.683-687
    • /
    • 2012
  • The purpose of this paper is to numerically study the characteristics of the indoor air flow of a square ceiling type diffuser according to the vane angle and flow rate. The CFX of ANSYS 13.0 was used for the CFD tool. The size of the room is $6m(X){\times}6m(Y){\times}2.7m(Z)$. The exhaust diffuser was positioned diagonally to the supply diffuser. This diffuser was designed to have many holes, so the air supply had long throw patterns with low velocity decay. The characteristics of the indoor air flow was studied at volume flow rates of 5.1 CMM and 7.4 CMM, and a vane angle from $30^{\circ}$ to $60^{\circ}$, every $10^{\circ}$.

Experimental study on air-water countercurrent flow limitation in a vertical tube based on measurement of film thickness behavior

  • Wan, Jie;Sun, Wan;Deng, Jian;Pan, Liang-ming;Ding, Shu-hua
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1821-1833
    • /
    • 2021
  • The gas-liquid counter-current flow limitation (CCFL) is closely related to efficient and safety operation of many equipment in industrial cycle. Air-water countercurrent flow experiments were performed in a tube with diameter of 25 mm to understand the triggering mechanism of CCFL. A parallel electrode probe was utilized to measure film thickness whereby the time domain and frequency domain characteristics of liquid film was obtained. The amplitude of the interface wave is small at low liquid flow rate while it becomes large at high liquid flow rate after being disturbed by the airflow. The spectral characteristic curve shows a peak-shaped distribution. The crest exists between 0 and 10 Hz and the amplitude decreases with the frequency increase. The analysis of visual observation and characteristic of film thickness indicate that two flooding mechanisms were identified at low and high liquid flow rate, respectively. At low liquid flow rate, the interfacial waves upward propagation is responsible for the formation of CCFL onset. While flooding at high liquid flow rate takes place as a direct consequence of the liquid bridging in tube due to the turbulent flow pattern. Moreover, it is believed that there is a transition region between the low and high liquid flow rate.

A Study on the Airflow Distribution in the Diagonal Ventilation Circuit for the Design of a High Level Radioactive Waste Repository (고준위 방사성 폐기물 처분장 설계를 위한 Diagonal 환기 회로 내 공기량 분배에 관한 연구)

  • Hwang, In-Phil;Choi, Heui-Joo;Roh, Jang-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.22 no.3
    • /
    • pp.173-180
    • /
    • 2012
  • In this study, diagonal ventilation circuits that are advantageous in air flow direction control were studied. Based on the results of the study, it could be seen that air volumes in diagonal ventilation circuits could also be calculated using numerical formulas or programs if the air volumes and air flow directions to be infused into diagonal branches are determined in advance as with other serial/parallel circuits. To apply the results, design plans for high level radioactive waste repositories applied with diagonal ventilation circuits and parallel ventilation circuits. To compared the each design plans and obtain expected operation results, ventilation network simulations were conducted through the Ventsim program which is a ventilation networking program. Based on the results, in the case of diagonal repositories that was expected to cause great increases in resistance, fan pressure was 1570 pa, total flux was 84 $m^3/s$, fan efficiency was 76.4%, fan power consumption was 181.2 kW and annual fan operating costs were 178,710,838 and thus maximum around 8% differences were shown in pressure and flux values and a difference of around 1.5% was shown in terms of operating costs.