• Title/Summary/Keyword: Airborne Noise Reduction Level

Search Result 7, Processing Time 0.018 seconds

Design of Close-Fitting Acoustic Enclosure of Diesel Engine (디젤엔진의 근접 음향 차폐장치 설계 및 성능평가)

  • 류정수;정우진;전재진
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.82-89
    • /
    • 1999
  • In this article, the performances of acoustic enclosure with double resilient mount system which was designed by ADD to reduce the radiated noise by main noise source of ships, was tested and evaluated. From test results, it was verified that the acoustic performances of acoustic enclosure satisfied the requirements; vibration isolation level at 1st stage mount system of 15 ㏈ and airborne noise reduction level of 20 ㏈ in broad band.

  • PDF

Field Measurement of Airborne Sound Insulation for Noise Reduction about Community Facilities in an Apartment Complex (공동주택 단지 내 주민공동시설의 소음 방지를 위한 공기전달음 차단 성능 현장 조사)

  • Seong, Yo-Han;Kim, Jin-Sik;Kim, Hye-Won;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.249-250
    • /
    • 2023
  • The objective of this study is to evaluate the airborne sound insulation performance between housing units and community facilities during the construction phase. Community facilities adjacent to housing units can lead to noise problems, hence it is necessary to minimize noise transmission during the design phase. However, flanking noise transmitted through gaps of structures, windows, pipes, and other openings may result in substandard sound insulation performance falling below the design standards. Therefore, It is crucial to measure airborne sound insulation in the field during the construction phase. The measurement was conducted using the survey method for the field measurement of the airborne sound insulation in accordance with KS F ISO 10052:2021. Although the noise standards caused by community facilities in apartment complexes are not specified in current laws and regulations, desired noise level was set based on international guidelines for indoor noise. First, the level of noise generated in community facilities was estimated, and then the sound insulation performance was evaluated to determine whether the desired noise level was achieved.

  • PDF

An Experimental Study to Improve Measurement Reliability for the Airborne Sound Insulation Performance by Laboratory Test (실험실 실험을 통한 벽체 차음성능 측정의 신뢰성 향상을 위한 실험적 연구)

  • Kim, Hang;Park, Hyeon Ku;Ku, Hee Mo;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.1
    • /
    • pp.35-44
    • /
    • 2014
  • Sound pressure levels in the receiving room while testing airborne sound insulation performance are varied by the measuring points. This may increase the measurement error, then decrease the measurement reliability. With this reason the research has carried out on the method to reduce deviations of sound pressure level in the ISO type rectangular laboratory focusing on the measurement of airborne sound insulation performance. Tests were made to see the effect of sound absorption in the receiving room, loudspeaker locations, microphones locations and flanking transmission path. Consequently, it was resulted that sound absorption in the receiving room and the loudspeaker location have influence on the sound level deviations especially in the low frequency. The microphone location was very important to get measurement reliability. The effective measuring point, which the sound level difference with average sound pressure level is within 2 dB, could yield most reliable average sound pressure level. Therefore it is necessary to find the effective measuring points in the receiving room. Flanking transmission path should be sealed using sound absorber or magnet etc. to prevent from lowering the sound insulation performance.

The Reduction of Tire Pattern Noise Using Time-Frequency Transform (저소음 타이어 설계에 대한 시변주파수 분석 적용)

  • Hwang, S.W.;Bang, M.J.;Kim, S.J.;Cho, C.T.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.144-147
    • /
    • 2005
  • The tire is considered as one of the Important noise sources having an influence on vehicle's performance. The Pattern noise of a tire is the transmission sound of airborne noise. On smooth asphalt road, Pattern noise is amplified with the velocity. In recent, the study on the reduction of Pattern noise is energetically processed. Pattern noise is strongly related with pitch sequence. To reduce the pattern noise, tire's designer has to randomize the sequence of pitch. The FFT is a traditional method to evaluate the level of the randomization of the pitch sequence, but gives no information on time-varying, instantaneous frequency. In the study, we found that Time-Frequency transform is a useful method to non-stationary signal such as tire noise.

  • PDF

The Reduction of Tire Pattern Noise Using Time-frequency Transform (시변주파수 분석을 이용한 저소음 타이어 설계)

  • Hwang, S.W.;Bang, M.M.;Rho, K.H.;Kim, S.J.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.627-633
    • /
    • 2006
  • The tire is considered as one of the important noise sources having an influence on vehicle's performance. The Pattern noise of a tire is the transmission sound of airborne noise. On smooth asphalt road, Pattern noise is amplified with the velocity. In recent, the study on the reduction of Pattern noise is energetically processed. Pattern noise is strongly related with pitch sequence. To reduce the pattern noise, tire's designer has to randomize the sequence of pitch. The FFT is a traditional method to evaluate the level of the randomization of the pitch sequence, but gives no information on time-varying, instantaneous frequency. In the study, we found that Time-Frequency transform is a useful method to non-stationary signal such as tire noise.

Estimation of flanking transmission due to difference between laboratory and field test (실험실 및 현장실험을 통한 벽체의 우회전달음 평가에 관한 연구)

  • Chung, J.Y.;Lee, S.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1383-1386
    • /
    • 2006
  • This study examines the difference of airborne sound isolation between laboratory and field test. The airborne sound isolation between adjacent dwellings in multi-family buildings is often much less than would be expected from the rated sound reduction index of the nominally-separating wall, due to structure-borne transmission of vibration at the junctions of wall. A variety of construction modifications to control such transmission have also been evaluated. This study presents a factor of the difference for flanking involving joint of wall, and shows the effect of some practical modifications that control the key flanking paths

  • PDF

Acoustic Performance of the Multilayered Panel with Helmholtz Resonators (Helmholtz 공명기를 내장한 다층패널의 음향 특성에 관한 연구)

  • Jong-Soo Seo;Jae-Jin Jeon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.1
    • /
    • pp.123-134
    • /
    • 1992
  • The reduction of the airborne noise level is essential to the comfortability for mien and passengers in ships. In this paper, the acoustic characteristics on the multilayered acoustic panel with the Helmholtz resonator was described analytically and experimentally. The design software based on the Transfer Matrix Analysis(TMA) method for the acoustic enclosing panel was developed. According to the change of the design parameters of the panel, verious transmission losses were obtained using the developed software. As a result, it was verified that the acoustic characteristics of the composite panel was excellent in comparison with the conventional acoustic partitioning structures. This panel can be applicable to the acoustic enclosure system.

  • PDF