• 제목/요약/키워드: Airborne Bacteria

검색결과 121건 처리시간 0.029초

생식용 굴(Crassostrea gigas) 작업장의 위생안전성에 대한 모니터링 (Safety Monitoring of a Processing Plant for Preparing Raw Oysters Crassostrea gigas for Consumption)

  • 강경태;박선영;최종덕;김민주;허민수;김진수
    • 한국수산과학회지
    • /
    • 제50권2호
    • /
    • pp.120-129
    • /
    • 2017
  • This study assessed the safety of raw oysters Crassostrea gigas for consumption during processing in a processing plant. Bacterial contamination (e.g., viable cell counts, coliform groups, Escherichia. coli and pathogenic bacteria) and chemical contamination (e.g., heavy metals and shellfish toxins) were measured on raw oysters, a processing equipment, employees and work areas. No total mercury, lead, paralytic shellfish poison, diarrheic shellfish poison or norovirus was detected in any post-harvested oyster samples. However, the cadmium level ranged from 0.1-0.2 mg/kg. The viable cell count, E. coli and coliform group levels in post-harvested oysters ranged from 4.00-4.54 log CFU/g, ND-210 MPN/100 g and 110-410 MPN/100 g, respectively. The viable contaminating cell counts on employees, equipment and work areas were in the range of $0.90-3.46log\;CFU/100cm^2$. Airborne bacteria in the work areas ranged from 0.60 to 1.81 log CFU/plate/15 min. Thus, no significant health risks were detected in the processing plant.

한국 전통 누룩 미생물의 문헌적 고찰(1945년 이후를 중심으로) (Bibliographical Study on Microorganims of Traditional Korean Nuruk(Since 1945))

  • 유대식;김정;김현수;현지숙;하현팔;박문근
    • 한국식품영양과학회지
    • /
    • 제27권4호
    • /
    • pp.789-799
    • /
    • 1998
  • Literatures on microorganisms of traditional Korean nuruk published since 1945 were reviewed in this paper. Traditional Korean nuruk consists of raw barley and various grains. Traditional Korean nuruk consists of unbolied raw barely and various grains. They are ground to paste and moistened, and then naturally inoculated by airborne microorganisms. Therefore, many kinds of microorganisms such as fungi, yeast, and bacteria grwo in nuruk. Since 1945, new 14 species of Aspergillus and 9 species of Penicillium have been identified from traditional Korean nuruk. Total number of fungal species identified so far is now up to 38 species among 12 different genus. Among newly isolated fungal species, Aspergillus penicilloides and Penicillium, expansum showed not only high production rate of acid and amylase but also extreme stability of the enzyme at room temperature for 3 months. As examples of newly isolated yeast species, there are 5 species of Candida, 4 species of Hansenula, 1 species of Pichia and 1 species of Schizosaccharomyces. Total number of yeast species isolated so far is up to 18 species from different 8 genus. Newly isolated bacteria, were Bacillus pumilus, Lactobacillus casei and Leuconostoc mesenteroides.

  • PDF

큰느타리 재배사에서 헤파필터 교체 이후 기간에 따른 미생물상 변화 (Changes in microbial phase by period after hepa filter replacement in King oyster(Pleurotus eryngii) mushroom cultivation)

  • 박혜성;민경진;이은지;이찬중
    • 한국버섯학회지
    • /
    • 제18권4호
    • /
    • pp.398-402
    • /
    • 2020
  • 버섯은 대부분 시설에서 재배되기 때문에 안전하게 고품질의 버섯 생산을 위해서는 재배사 내 환경에 대한 정보가 필요하다. 따라서 본 연구에서는 헤파필터 교체에 따른 큰느타리 재배사 대기중 미생물상 변화를 분석하여 헤파필터 적정 교체기간을 설정하고자 연구를 수행하였다. 헤파필터 교체 전 재배단계별 대기중 세균 및 진균 밀도는 배지제조과정에서 세균 169.7 cfu/㎥, 진균 570 cfu/㎥, 균 긁기과정에서 세균 126.3 cfu/㎥, 진균 560cfu/㎥로 부유균의 밀도가 가장 높았다. 헤파필터 교체 후 세균의 밀도는 배양실에서 가장 낮아졌고, 진균의 밀도는 냉각실에서 가장 낮게 나타났다. 헤파필터 교체전 Cladosporium sp. 등 7속 7종이었고, 교체 후 1개월은 Penicillium sp. 등 6속 6종, 2개월은 Cladosporium cladosporioides 등 4속 7종, 3개월차는 Mucor plumbeus 등 5속 7종, 4개월에서 6개월까지는 Penicillium brevicompactum 등 각각 5속 12종, 5속 10종, 5속 10종으로 교체 후 기간이 지날수록 종이 다양해지고 증가하였다. 부유균의 밀도는 헤파필터 교체 후 2개월 후 가장 낮았고 차츰 증가하다가 6개월에는 교체전 밀도와 비슷해지거나 높아지는 것을 확인하였다. 따라서 헤파필터는 6개월마다 교체하는 것이 오염저감을 위해 효율적인 것으로 판단된다.

Pulmonary Tuberculosis, Tuberculous Meningitis의 임상치험 3례 (The Clinical Report on the Pulmonary Tuberculosis, Tuberculosis Meningitis)

  • 손윤정;임중화;이도형
    • 대한한방내과학회지
    • /
    • 제25권2호
    • /
    • pp.352-360
    • /
    • 2004
  • Tuberculosis, one of the oldest diseases known to affect humans, is caused by bacteria belonging to the Mycobacterium luberculosis complex. The diseases usually affects the lungs, although in up to one-third of cases other organs are affected. If properly treated, tuberculosis caused by drug-susceptible strains is curable in virtually all cases. If untreated, the disease may be fatal within 5 years in more than half of cases. Transmission usually takes place through the airborne spread of droplets of nuclei produced by patients with infectious pulmonary tuberculosis. Two patients with Pulmonary Tuberculosis and one with Tuberculous Meningitis were recently examined. The changes in these patient's symptoms through both western medical treatment and oriental medical treatment are reported.

  • PDF

광대역대 활성광촉매를 활용한 융·복합 구조 공기살균정화장치 개발 (Development of air-sterilization purification system of fusion and composite structure using broadband-to-active photocatalyst)

  • 윤승배;황윤정;김승천
    • 한국융합학회논문지
    • /
    • 제10권4호
    • /
    • pp.147-151
    • /
    • 2019
  • 현대인들은 가정, 학교 혹은 직장, 병원, 쇼핑몰, 지하철역과 객실, 주차장 등 일상생활의 대부분을 실내에서 보내게 된다. 이렇듯 실내에 갇힌 현대인들은 갇힌 공기 속에서 살아갈 수밖에 없다. 이에 실내 공기질 향상을 위한 공기정화장치는 많이 개발되었으나 대다수의 공기정화장치는 필터에 의한 필터링과 유해세균 살균방식에 있어 자외선이라는 제한된 영역에서의 살균방식에 국한 할 수밖에 없었다. 여기서는 실내 공기질 향상은 물론 원천적으로 실내공기중의 부유 세균을 제거하고, 자외선뿐만 아니라 가시광선에서도 활동하는 광촉매를 적용한 미디어광촉매필터를 활용한 광대역대 활성광촉매를 활용한 융 복합 구조 공기살균정화장치 개발하고자 한다.

일부 종합 병원 로비의 공기 중 엔도톡신 농도에 미치는 환경 요인 평가 (An Assessment of Environmental Characteristics Associated with the Level of Endotoxin Concentration in Hospital Lobbies)

  • 이경민;염정관;이원재;류승훈;박동진;박동욱
    • 한국산업보건학회지
    • /
    • 제24권3호
    • /
    • pp.310-320
    • /
    • 2014
  • Backgrounds: Endotoxin, which found in the outer membrane of the gram-negative bacteria cell wall, makes up almost all of the lipopolysaccharide(LPS). When people are exposed to endotoxin,it can result in diverse health effects such as an airway irritation and inflammation, fever, malaise, bronchitis, allergic asthma, toxic pneumonitis, hypersensitivity lung disease. Cases among the elderly, children or pregnant can occur more frequently than a healthy adult if they are repeatedly exposed to the existing endotoxin. Therefore, we investigated and assessed the environmental characteristics associated with the airborne endotoxin concentration level in six hospital lobbies. Method: Endotoxin from indoor air in six hospital lobbies was measured by an area sampling method and analyzed according to American Society for Testing and Materials International(ASTM international) E2144-01. Total suspended particulate(TSP), carbon dioxide($CO_2$), temperature and humidity were also measured by using direct reading measurements or airborne sampling equipment at the same time. Environmental characteristics were appropriately divided into two or three groups for a statistics analysis. One-way analysis variable(one-way ANOVA) was used to examine a difference of the endotoxin concentration, depending on the environmental characteristics. In addition, only variables with p-value(p<0.25) were eventually designed to the best model by using multiple regression analysis. Results: The correlation analysis result indicated that TSP(p=0.003) and $CO_2$(p<0.0001) levels were significantly associated with endotoxin concentration levels. In contrast, temperature(p<0.068) and humidity(p<0.365) were not associated with endotoxin concentration. Levels of endotoxin concentration were statistically different among the environmental characteristics of Service time(p=0.01), Establishment of hospital(p<0.001), Scale of hospital(p=0.01), Day average people using hospital(p=0.03), Cleaning time of lobby(p=0.05), Season(p<0.001), and Cleaning of ventilation system(p<0.001) according to ANOVA. Finally, the best model(Adjusted R-square=72%) that we designed through a multiple regression test included environmental characteristics related to Service time, Area of lobby, Season, Cleaning of ventilation system, and Temperature. Conclusions: According to this study, our result showed a normal level of endotoxin concentration in the hospital lobbies and found environmental management methods to reduce the level of endotoxin concentration to a minimum. Consequently, this study recognized to be requirement for the management of ventilation systems and an indoor temperature in order to reduce the level of endotoxin concentration in the hospital lobbies.

광촉매와 UVA에 의한 실내 부유 미생물(E. coli 및 Bacillus. subtilis sp.) 살균 제거 연구 (Photocatalytic disinfection of indoor suspended microorganisms (Escherichia coli and Bacillus subtilis spore) with ultraviolet light)

  • 윤영한;남숙현;주진철;안호상
    • 한국산학기술학회논문지
    • /
    • 제15권2호
    • /
    • pp.1204-1210
    • /
    • 2014
  • 실내공기 오염물질의 제어를 통하여 공기질을 개선시킬 수 있는 요소기술의 개발을 위하여 미세부유먼지 제거방법을 도출하고자 하였다. 미세부유먼지 중에는 분진과 같은 무기물과 박테리아와 같은 작은 유기물도 포함되어 있어 이들의 동시 제거를 위한 연구가 필요하다. 본 연구에서는 광촉매 및 UVA에 의한 미세부유먼지 중 미생물 제거 기술의 개발을 위하여 여러 종류의 광촉매에 대한 미생물 살균율을 조사하였다. 이를 위하여 3가지 종류의 광촉매(ZnO, $TiO_2$, ZnO/Laponite ball)와 최소한의 UVA 자외선 조사량 3 (${\mu}W/cm^2$)을 이용하여 실내공기 부유미생물의 지표로 사용되는 Gram 양성균인 E. Coli와 Gram 음성균인 Bacillus. subtilis sp.에 대하여 살균실험을 진행하였다. 실험결과, 최소한의 UVA 자외선 조사량에서도 광촉매제와 함께 두 시간 정도 반응하였을 때 E-Coli의 경우 세 가지 광촉매제 모두에서 80 % 이상 사멸되는 것으로 나타났으며, UVA 단독 사용보다는 약 30 % 높은 사멸률을 보였다. 광촉매제 중에는 ZnO/Laponite ball 복합체의 경우에 $TiO_2$와 동등한 살균력이 있는 것으로 나타났다. 하지만, 포자상태에서 강한 외벽을 가지고 있는 B. subtilis sp.의 경우는 낮은 자외선 조사량으로는 살균효과가 저하되기 때문에 살균율을 높일 수 있는 최적의 촉매제 종류와 첨가량 및 자외선 조사량을 찾아야 할 것으로 판단된다.

냉온수기에서 일반세균의 분포 및 분리한 세균의 특성 (Distribution and Characteristics of Heterotrophic Plate Count Bacteria in Water Samples from Drinking Water Dispensers)

  • 이은화;고지윤;김종설
    • 미생물학회지
    • /
    • 제44권3호
    • /
    • pp.244-250
    • /
    • 2008
  • 울산 소재 S회사(S-C)와 U고등학교(U-H)에 설치된 냉온수기를 대상으로 S-C에서 냉수 74개, U-H에서 냉수와 온수 각 36개의 시료를 채수하여 미생물 분포를 조사하였다. 일반세균 농도의 중간값은, S-C 시료에서 53 CFU/ml ($0\sim4,135$ CFU/ml)이었으며, U-H의 경우 냉수에서 80 CFU/ml ($0\sim1,480$ CFU/ml), 온수에서 0 CFU/ml ($0\sim240$ CFU/ml)이었다. S-C 시료의 38%, U-H 냉수 시료의 42%에서 일반세균에 대한 먹는 물 수질기준인 100 CFU/ml을 초과하였으며, 대장균군은S-C의 1개 시료에서 검출되었다. 냉온수기에서 검출되는 미생물의 주요오염 경로를 확인하고자, 2회에 걸쳐 먹는 샘물 용기로부터 각각 6일과 8일 동안 매일 시료를 채수하였으며, 2회 채수는 냉온수기의 꼭지에서도 행하였다. 일반세균 농도의 평균값은, 먹는 샘물 용기에서 1회 33 CFU/ml, 2회 132 CFU/ml이었으며, 냉수 꼭지 시료에서 1,022 CFU/ml로, 냉온수기 꼭지에서 검출되는 대부분의 세균은 먹는 샘물이 수조통과 통로관을 거치면서 오염된 것으로 판단된다. 먹는 샘물 용기를 냉온수기에 연결한 후 시간의 경과에 따른 용기 내 일반세균수의 유의성 있는 증가는 없었다. 임의의 100개 일반세균 집 락을 대상으로 순수배양 후표현형에 따른 동정 시험을 하였으며, 그람양성 3속6종,그람음성 7속7종 등, 모두 10속13종의 세균을 잠정적으로 확인하였다. U-H의 4대 냉온수기 꼭지에서, 그람양성은 전체의 72%이었고, 그람양성의 Micrococcus spp.가 전체의 54%를 차지하여 가장 많았다. Micrococus spp.와 그람음성의 Sphingomonas paucimobilis는4대의 냉온수기 모두에서 분리되었다. 냉온수기의 일반세균은 주로 실내 공기중 미생물로부터 유래하며, 이들 미생물이 냉온수기의 수조통 흑은 통로관에서 생물막 형성에 중요한 역할을 하는 것으로 생각된다.

Bioaerosol Exposure and in vitro Activation of Toll-like Receptors in a Norwegian Waste Sorting Plant

  • Eriksen, Elke;Graff, Pal;Pedersen, Ine;Straumfors, Anne;Afanou, Anani K.
    • Safety and Health at Work
    • /
    • 제13권1호
    • /
    • pp.9-16
    • /
    • 2022
  • Background: The global shift toward greener societies demands new technologies and work operations in the waste-management sector. However, progressive industrial methods do not necessarily consider workers' health. This study characterized workers' exposure to bioaerosols and investigated the bioaerosols' potential to engage the immune system in vitro. Methods: Full shift personal aerosol sampling was conducted over three consecutive days. Dust load was analyzed by gravimetry, fungal and actinobacterial spores were analyzed by scanning electron microscopy, and endotoxin by limulus amebocyte lysate (LAL) assay. In vitro exposure of HEK cells to airborne dust samples was used to investigate the potential of inducing an inflammatory reaction. Results: The total dust exposure level exceeded the recommended occupational exposure limit (OEL) of 5.0 mg/m3 in 3 out of 15 samples. The inhalable endotoxin level exceeded the recommended exposure level by a 7-fold, whereas the fungal spore level exceeded the recommended exposure level by an 11-fold. Actinobacterial spores were identified in 8 out of 14 samples. In vitro experiments revealed significant TLR2 activation in 9 out of 14 samples vs. significant TLR4 activation in all samples. Conclusion: The present study showed that the dust samples contained potentially health-impairing endotoxin, fungi, and actinobacterial levels. Furthermore, the sampled dust contained microbial components capable of inducing TLR activation and thus have the potential to evoke an inflammatory response in exposed individuals.

전동차내 부유 미생물 저감방안에 관한 연구 (A Research to Decrease Airborne Microoganism the Train)

  • 최성호;최순기;손영진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2895-2901
    • /
    • 2011
  • 서울메트로 지하철 1~4호선 이용객은 하루 평균 450만명이 지하철을 이용(2010년 상반기 수송인원 현황)하고 있으며 이것은 서울시 인구 57%에(2009년도 서울시 인구 총1,046만명) 가까운 사람들이 지하철을 이용하고 있는 것으로 나타남에 따라 전동차에 쾌적한 실내공기질 유지 및 관리는 무엇보다 중요하다. 특히 전동차내 실내공기질에 영향을 미치는 요인으로는 승객의 재채기, 호흡과 같은 생체 활동 및 피부각질 등에 의한 부유 미생물 작용에 있다(권순박 등, 2011). 바이러스와 같은 미생물 오염 물질이 승객의 인체의 호흡기, 점막부위, 피부 등에 접촉 할 경우 과민성 질환, 아토피 피부염, 전염성 질환, 알레르기성 질환, 호흡기 질환을 유발할 수 있는(환경부-국립환경과학원, 생활속 세균 이렇게 관리하세요) 산업 보건상의 문제로 대두되고 있어 적절한 환기 시스템 도입과 제습을 위한 냉방 등이 필요한 실정이다. 시민들의 관심과 보조를 맞추어 지하철 2호선 출 퇴근 및 평상시 전동차 객실내 부유 미생물을 측정한 결과 부유세균과 부유진균은 2011년도 85~385$cfu/m^3$, 67~98$cfu/m^3$로 기준치(별도의 법적 기준은 없으나, 부유세균은 국내 실내기준 800$cfu/m^3$, 부유진균은 세계보건기구의 가이드라인 150$cfu/m^3$) 보다 낮은 수준으로 나타났으나 유동인구가 많은 출 퇴근 시간대에는 미생물 오염 물질이 승객에게 쉽게 전염 될 가능성이 있을 것으로 사료됨에 따라 부유 미생물 오염방지를 위한 공기조화설비 성능개선 등 실질적인 개선방안을 찾는 것이 필요하다. 이에 본 연구에서는 2004년 이후 부유 미생물 제어장치에 대한 연구 논문을 분석하여 부유미생물이 승객들에게 미치는 영향, 환기량 증대방안 등의 다양한 인자에 대한 분석을 통하여 전동차내 공기질을 실질적으로 개선할 수 있는 방법을 연구 하였다.

  • PDF