• Title/Summary/Keyword: Air-to-Air Mode

Search Result 985, Processing Time 0.035 seconds

Measurement and analysis of PM10 and PM2.5 from chimneys of coal-fired power plants using a light scattering method (광산란법을 이용한 국내 석탄화력발전소 굴뚝에서 배출되는 PM10, PM2.5 측정 및 분석)

  • Shin, Dongho;Kim, Younghun;Hong, Kee-Jung;Lee, Gunhee;Park, Inyong;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.16 no.4
    • /
    • pp.131-140
    • /
    • 2020
  • Air pollutants emitted from chimneys of coal-fired power plants are considered to be a major source of fine particulate matter in the atmosphere. In order to manage fine particle in the chimney of a coal-fired power plant, it is necessary to know the concentration of fine particle emitted in real time, but the current system is difficult. In this study, a real-time measurement system for chimney fine particle was developed, and measurements were performed on six coal-fired power plants. Through the measurements, the mass concentration distribution according to the particle size could be secured. All six chimneys showed bimodal distribution, and the count median diameters of each mode were 0.5 and 1.1 ㎛. In addition, it was compared with the gravimetric measurement method, and it was determined that the relative accuracy for PM10 was within 20%, and the value measured using the developed measuring instrument was reliable. Finally, three power plants were continuously measured for one month, and as a result of comparing the concentration of PM10 according to the amount of power generation, it was confirmed that the PM10 discharged from the chimney increased in the form of an exponential function according to the amount of power generation.

Estimation of Gas-particle partitioning Coefficients (Kp) of Carcinogenic polycyclic Aromatic hydrocarbons in Carbonaceous Aerosols Collected at Chiang - Mai, Bangkok and hat-Yai, Thailand

  • Pongpiachan, Siwatt;Ho, Kin Fai;Cao, Junji
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2461-2476
    • /
    • 2013
  • To assess environmental contamination with carcinogens, carbonaceous compounds, water-soluble ionic species and trace gaseous species were identified and quantified every three hours for three days st three different atmospheric layer at the heart of chiang-Mai, bangkok and hat-Yai from December 2006 to February 2007. A DRI model 2001 Themal/Optical Carbon Analyzer with the IMPROVE thermal/optical reflectance (TOR) protocol was used to quantify the organic carbon(OC) and elemental carbon content in $PM_{10}$. Diurnal and vertical variability was also carefully investigated. In general, OC and EC contenttration shoeed the highest values at the monitoring period o 21.00-00.00 as consequences of human activities at night bazaar coupled with reduction of mixing layer, decreased wind speed and termination of photolysis nighttime. Morning peaks of carboaceous compounds were observed during the sampling period of 06:00 -09:00, emphasizing the main contribution of traffic emission in the three cities. The estimation of incremental lifetime partculate matter exposure (ILPE) raises concern of high risk of carbonaceous accumulation over workers and residents living close to the observatory sites. The average values of incremental lifrtime particulate matter exposure (ILPE) of total carbon at Baiyoke Suit Hotel and Baiyoke Sky Hotel are approsimately ten time shigher then those air sample collected at prince of songkla University Hat-Yai campus corpse incinerator and fish-can maufacturing factory but only slightly higher than those of rice straw burnig in Songkla province. This indicates a high risk of developing lung cancer and other respiratory diseases across workers and residents living in high buildings located in Pratunam area. Using knowledge of carbonaceous fractions in $PM_{10}$, one can estimate the gas-particle partitioning of polycyclic aromatic hydrocarbons (PAHs). Dachs-Eisenreich model highlights the crucial role of adsorption in gas-particle partitioning of low molecular weight PAHs, whereas both absorption and adsorption tend to account for gas-particle partitioning of high molecular weight PAHs in urban residential zones of Thailand. Interestingly, the absorption mode alone plays a minor role in gas-partcle partitiining of PAHs in Chiang-Mai, Bangkok and hat-Yai.

Dispersion of Particle Pulse in Human Lung Airway (인체기관지내의 입자펄스 확산 실험)

  • 이진원;이동엽;추경호
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.511-518
    • /
    • 1998
  • In order to develop the aerosol bolus technique which is thought to be a potential tool for probing geometries or abnormalities of small airways, an experimental system of measuring fast time variations of particle concentration in the inhaled and exhaled breathing air was developed. The system generates monodisperse sebacic acrid particles of 1 micron size and 1.2 of geometric standard deviation in high concentration of $10^8$ particles/cc, delivers a short pulse of particles at the controlled instant during inhalation using a solenoid valve, and measures the fast change of particle concentration in using the laser light scattering. Successful operation of the generator and the measuring system was confirmed by smooth concentration profiles in inhalation. It was also confirmed that maintaining a constant breathing rate is essential to stable outputs and any disturbance in flow rate near the mode (maximum concentration) induces a large number of spurious peaks in the exhalation. Experimental data without strict control of breathing flow rate showed a substantial amount of scatter. The measured results showed an improvement in scatter over the existing results. When compared with theoretical predictions from 1-D convective diffusion equation and other experiments, general characteristics of dispersion for several penetration depths showed a good agreement, but there exists some difference in absolute values, which is attributed to the difference in body conditions. Improvements are needed in the theory, especially in relation to correcting for the effect of breathing flow rate.

  • PDF

EFFECTS OF THE ER,CR:YSGG LASER ON BONE BED PREPARATION WITH VARIOUS LASER TIPS

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Hong, Seong-Doo;Lee, Shin-Jae;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.255-260
    • /
    • 2008
  • STATEMENT OF PROBLEM: Preparation of implant beds with lasers is considered a safe and reliable method, but the accuracy of this technique has not been examined. PURPOSE: The purpose of this study was to evaluate the accuracy and effectiveness of implant bed preparation using an Er,Cr:YSGG laser. MATERIAL AND METHODS: An Er,Cr:YSGG laser was applied to pig rib bone. The laser was employed at a 5.75 W power setting, 30 Hz/sec pulse repetition, and 70 ${\mu}s$ pulse duration with 50 % water and 60% air spray. According to laser tips the groups were divided as follows; Group 1: paralleled - shaped sapphire tip (0.6 mm${\Phi}$), Group 2: paralleled - shaped zirconia tip (0.6 mm${\Phi}$), Group 3: tapered sapphire tip (0.4 mm${\Phi}$). The Er,Cr:YSGG laser tip was separated by 1 mm from the bone and applied for 15 seconds in a non-contact mode. After the application, the bone was sectioned for specimens. Histologic measurements were determined by computerized morphometry. The length of the prepared bone surface was measured and the width of the entrance was measured. The results were analyzed with one-way ANOVA (P<0.05). RESULTS: The prepared length of group 3 was longer than that of group 2. The prepared bone width was larger than the width of the laser tip in every group. Additional bone removal was observed adjacent to the prepared area and displayed an irregular surface. CONCLUSION & DISCUSSION: Different cutting effects were observed according to the laser tip, emphasizing the importance of proper tip selection in the clinical setting. This preliminary study supported the existence of hydrokinetic effects.

A Study on the Utility Interactive Photovoltaic System Using a Chopper and PWM Voltage Source Inverter for Air Conditioner a Clinic room (병실 냉.난방을 위한 초퍼와 PWM 전압형 인버터를 이용한 계통 연계형 태양광 발전시스템에 관한 연구)

  • Hwang, L.H.;Na, S.K.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.360-369
    • /
    • 2008
  • The solar cells should be operated at the maximum power point because its output characteristics were greatly fluctuated on the variation of insolation, temperature and load. It is necessary to install an inverter among electric power converts by means of the output power of solar cell is DC. The inverter is operated supply a sinusoidal current and voltage to the load and the interactive utility line. In this paper, the proposes a photovoltaic system is designed with a step up chopper and single phase PWM voltage source inverter. Synchronous signal and control signal was processed by one-chip microprocessor for stable modulation. The step up chopper is operated in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power point of solar cell without any influence on the variation of insolation and temperature for solar cell has typical dropping character. The single phase PWM voltage source inverter is consists of complex type of electric power converter to compensate for the defect, that is, solar cell cannot be develop continuously by connecting with the source of electric power for ordinary using. It can be cause the efect of saving electric power, from 10 to 20%. The single phase PWM voltage source inverter operates in situation, that its output voltage is in same phase with the utility voltage. The inverter are supplies an ac power with high factor and low level of harmonics to the load and the utility power system.

Radon Hazard Review of Spilled Groundwater and Tap Water in Incheon Metropolitan City Subway Station (인천광역시 지하철 역사 내 지하수 및 수돗물의 라돈 위해성 검토)

  • Lee, Yoo-Sang;Lee, Sang-Bok;Kang, Min-Seok;Jeong, Dong-Ha;Kim, Jin-Hong;Oh, Yoon-Sik;Choi, Se-Rin;Park, Jeong-Soo;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.671-677
    • /
    • 2021
  • Interest in the everyday hazards of radon has recently increased as such, this study attempted to examine the dangers of radon in spilled groundwater by comparing the radon concentrations of the drained groundwater and tap water used in recirculating systems in Incheon Subway restrooms. At five stations of Incheon Subway Line 1 and three stations of Line 2, drained groundwater is recirculated and used in restrooms for toilet flushing. Stations restroom tap water for hand washing that used as a control and the measured values of each were compared. With the cooperation of Incheon Transportation Corporation, samples of spilled groundwater and tap water were collected sealed to prevent contact with the air, and a DURRIDGE RAD7 was used as the experimental equipment. The collected samples were subjected to radial equilibration for approximately 3.5 h, at which the radon concentration reached its maximum, and then calculated as 10 measurements using the RAD7 underwater radon measurement mode. In all eight stations, the radon concentration in tap water was lower than the recommended amount. However, in an average of 7 out of the eight stations, the radon concentration in the effluent groundwater was 100 times higher than that in tap water. Since high radon concentrations in groundwater runoff can be harmful to humans, and there is no accurate standard for radon concentrations in domestic water, it is necessary to continuously monitor radon in water and prepare a guidance of recommended values.

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform (스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin;Kwon, Tae-Soon;Lee, Duck-Hee
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.485-496
    • /
    • 2018
  • In this paper, the smoke behavior in an underground station on operation of the fans in the ventiliation of the station was measured by the experimental method when the fire occurred in the underground station platform where the platfrom screen door was installed. The ventilation characteristics were compared when the ventilation system was operated and when the ventilation system was not operated when a fire occurred at the platform where the clean door was closed. To simulate the fire smoke, the smoke generated from the smoke generator was heated using a hot air fan. The transmittance was measured using a smoke density meter to quantitatively measure fire smoke. If the screen door is closed and the ventilation system of the underground station does not work, it is confirmed that if a fire occurs in the platform, smoke accumulates inside the platform, evacuating passengers is very difficult and can lead to a very dangerous situation. On the other hand, under the condition that the ventilation facility of the subway station is operated, the smoke evacuates to the outside through the ventilation facility of the underground station, and airflow is formed in the direction from the waiting room to the waiting area, so that the passenger located on the platform can safely evacuate toward the concourse. In the following paper, we will discuss the concurrent effect of tunnel ventilation through tunnel vent near the platform.

Physicochemical Characterization and Changes in Nutritional Composition of Onions Depending on Type of Freezing Process (냉동 조건에 따른 양파의 이화학적 특성 및 영양성분 변화)

  • Jang, Min-Young;Jo, Yeon-Ji;Hwang, In-Guk;Yoo, Seon-Mi;Choi, Mi-Jung;Min, Sang-Gi
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.7
    • /
    • pp.1055-1061
    • /
    • 2014
  • Innovative freezing technology is currently applied to preserve foodstuffs for long-term storage. Generally, the quality of frozen food is closely related to the types of freezing and thawing processes. In this study, we characterized the physicochemical properties of onions depending on freezing rate. When onions were frozen at $-40^{\circ}C$, freezing rates were 0.1, 0.5, and $0.7^{\circ}C/min$ depending on air-blast quick freezer mode. Onions were thawed by microwave irradiation at 400 W. Hardness of onion dramatically decreased after freezing and thawing compared with blanched onion. However, the fastest freezing rate did not affect hardness. Thawing loss of onion decreased with a faster freezing rate. For morphological observation, onion frozen at a faster rate showed a smaller ice-crystal size. Vitamin C content decreased upon blanching or freezing, but there was no significant difference according to freezing rate. Although free sugar content also decreased upon blanching and freezing, its highest content was at $0.7^{\circ}C/min$ freezing. Among organic acids, malic acid content was highest at $0.7^{\circ}C/min$ freezing. Based on this study, it could be suggested that a faster freezing rate is effective to improve frozen food quality in accordance with preventing tissue damage or minimizing destruction of nutrients.

Measurement of GPR Direct Wave Velocity by f-k Analysis and Determination of Dielectric Property by Dispersive Guided Wave (f-k 분석에 의한 레이다파 속도 측정 및 레이다파의 분산성 가이드 현상을 이용한 지하 물성 계산)

  • Yi, Myeong-Jong;Endres, Anthony L.;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.4
    • /
    • pp.304-315
    • /
    • 2006
  • We have examined the applicability of f-k analysis to the GPR direct wave measurement for water content to characterize vadose zone condition. When the vadose zone consists of a dry surface layer over wet substratum, we obtained f-k spectra where most of the energy is bounded by the air and dry soil velocities. In this case, dry soil velocity was successfully estimated by using high frequency data. On the other hands, when wet soil overlies dry substratum, the f-k spectra show a contrasting response where most of the energy travels with the velocity bounded by dry and wet soil velocities. In this case, the radar waves are trapped and guided within wet soil layer, exhibiting velocity dispersion. By adopting modal propagation theory, we could formulae a simple inversion code to find two layer's dielectric constants as well as layer thickness. By inverting the velocity dispersion curve obtained from f-k spectra of synthetic modeling data, we could obtain good estimates of dielectric constants of each layer as well as first layer thickness. Moreover, we could obtain more accurate results by including the higher mode data. We expect this method will be useful to get the quantitative property of real subsurface when the field condition is similar.

Preparation of PVdF/GO Composite Nanofibrous Flat Membrane and its Permeation Characteristics in Activated Sludge (PVdF/GO 복합 나노섬유 평막의 제조 및 활성슬러지 내 투과특성)

  • Won, In Hye;Jang, Wongi;Chung, Kun Yong;Byun, Hongsik
    • Membrane Journal
    • /
    • v.25 no.1
    • /
    • pp.67-74
    • /
    • 2015
  • In this study the nanofiber was prepared by electrospinning method with polyvinylidene fluoride (PVdF) and a completely dispersed solution of graphene oxide (GO) in the mixed solvent of dimethylformamide (DMF) and acetone. The $0.4{\mu}m$ pore size microfiltration flat membrane was made by increasing layers of the PVdF/GO composite nanofiber. Also, transmembrane pressure (TMP) was measured in order to evaluate fouling of the PVdF/GO composite membrane which was introduced GO reducing biological fouling with the intrinsic antibacterial characteristics. The permeate experiments were carried out simultaneously for the PVdF/GO and commercialized CPVC (chlorinated polyvinyl chloride) flat membranes with $0.01m^2$ effective area in the activated sludge solution of MLSS 4,500 mg/L. TMP of PVdF/GO membrane decreased up to 79% lower than that of CPVC for $10L/m^2{\cdot}h$ permeate flux without air supply. Also, for the case of run/stop operational mode, TMP of PVdF/GO membrane decreased up to 69% lower than that of CPVC for $10L/m^2{\cdot}h$.