• Title/Summary/Keyword: Air-side

Search Result 1,200, Processing Time 0.03 seconds

An Experimental Analysis of the Effects of Water Vapor Partial Pressure in Inlet Air, Spark Advance and Fuel Type on the Flame Propagation in a Spark Ingnition Engine (흡기중의 수증기분압과 점화시기 및 연료 변화에 따른 스파크 점화기관의 화염 전파 특성 분석)

  • 이택헌;전광민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.191-198
    • /
    • 1998
  • In this study, the effects of water vapor in inlet air, spark advance and fuel type in the spark ignition engine were investigated through the experiments of combustion and flame arriving pattern analysis using ionization probe. The results of flame propagation experiment using ionization probe show that the flame which ignited from spark plug located at the center of the combustion chamber propagated faster in exhaust side than in intake side due to the mixture flow motion inducted into combustion chamber from intake tumble port at all conditions. And as the partial vapor pressure increased, the flame propagation became slower in all direction. Especially effects were greater for intake side than the exhaust side.

  • PDF

Mixed Control with Aerodynamic Fin and Side Thruster Applied to Air Defense Missile

  • Chanho Song;Kim, Yoon-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.148.4-148
    • /
    • 2001
  • This paper shows an autopilot design example with simulation results for a medium range surface-to-air missile used to intercept fast maneuver targets. The missile is assumed to use both aerodynamic fins and side thrusters to achieve fast time response. The steady-state maneuver capability of the missile is assumed to be enough at high altitude to engage usual maneuvering targets. Side thruster is used to get an extremely rapid acceleration response at high altitude where the missile´s aerodynamic control effectiveness is weak. The strategy of control design is firstly to employ side thrusters to achieve a rapid response and then to hand-over the control to the aerodynamic fins to maintain the desired acceleration command in the steady state ...

  • PDF

Enhancement of Stratification for Solar Water Storage Tank with Spiral Jacket and Coil(Part 2 Simulation) (나선유로에 의한 태양열 축열조 성층화 촉진(제2보 시뮬레이션))

  • Lee, Seong Hoon;Son, Hyo Seok;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • We have performed experiments to enhance the stratification in a storage tank in order to raise the collector efficiency and solar fraction in solar thermal systems. The storage tank with a spiral jacket in the side wall has a scroll-shaped heat exchanger coil added to the upper part. The performance was compared between only the side and upper-side heating part through simulation using TRNSYS under the same weather conditions and initial conditions. As a result, the upper-side heating has a 4.2% advantage in solar fraction, but almost no increase in collector efficiency.

Mission Task & Workload Analysis of Armed Helicopter (무장헬기 임무절차 수립 및 임무하중 분석 연구)

  • Park, Hyojin;Lee, Jinwoo;Lee, Minwoo;Park, Sang C.;Kwon, Yongjin;Lee, Jonghoon
    • Journal of the Korea Society for Simulation
    • /
    • v.21 no.4
    • /
    • pp.25-33
    • /
    • 2012
  • Armed helicopter is an integral part of armed forces, which conducts vital missions, such as anti-armor attack, close air support, escorting air assault operations, and reconnaissance. A typical cockpit arrangement of armed helicopters has been a tandem configuration. This is to reduce the frontal area, which in turn increases the forward speed as well as reduces the chance of being hit by enemy fires. However, many armed helicopters in the world are now being developed as a side-by-side configuration. Such configuration is quite different from the conventional cockpit arrangement in light of the crew communications and situational awareness. Therefore, the main objective of this study is to find the optimized combination of mission tasks among pilots in a side-by-side configuration cockpit by measuring the workload using the NASA Task Load Index method. The experimental results indicate that the workload of crew members differ as disparate tasks are being performed.

A Study on Estimating Real-time Thermal Load During GHP Operation in Heating Mode (GHP 난방 모드 운전시 실시간 부하 추정방법에 관한 연구)

  • Seo, Jeong-A;Shin, Young-Gy;Oh, Se-Je;Jeong, Sang-Duck;Ji, Kyoung-Chul;Jeong, Jin-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.32-37
    • /
    • 2011
  • The present study has been conducted to propose an algorithm regarding real-time load estimation of a gas engine-driven heat pump. In the study, thermal load of an indoor unit is estimated in terms of air-side and refrigerant-side. The air-side estimation is based on a typical heat exchanger model and is found to be in good agreement with experimental data. When it comes to the refrigerant-side load, a pressure difference across a valve must be estimated. For the estimation, it is assumed to be proportional to a bigger pressure difference that is available either by measurement or by estimation. Relative good agreement between the air- and refrigerant-sides suggests that the assumption may be plausible for the load estimation. The summed flow rate of all of indoor units is in good agreement with the throughput of the compressor which are calculated from the manufacturer's software. Accordingly, estimated thermal loads are also in good agreement. The proposed algorithm may be further developed for improved control algorithm and fault diagnosis.

Heat Transfer Characteristics of Individual Row of Fin and Tube Heat Exchangers

  • Chang Keun-Sun;Kweon Young-Chul;Kim Young-Jae;Jeong Ji-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.2
    • /
    • pp.49-56
    • /
    • 2006
  • Heat transfer performances of individual row of two-row fin and tube heat exchangers are experimentally investigated. Tested are four heat exchangers which are geometrically identical with the exception of fin shape, slit or louver, and that the fins between the first row and the second row are connected or separated. The tube diameter and fin spacing of the heat exchangers examined are 7mm and 1.4mm, respectively. All thermal fluid measurements are made using a psychrometric calorimeter. In order to evaluate air-side heat transfer coefficients of individual rows, tube-side water flow rates of individual rows are independently controlled such that the water-side temperature drops in each row remain at $5^{\circ}C$. Frontal air velocity varies in the range from 0.7m/s to 2.5m/s. Heat transfer coefficients are presented in terms of Colburn ${\jmath}-factor$. The results show that the heat transfer coefficient of the upstream row is larger than that for the downstream row at low Reynolds numbers.

Comparison of Condenser Characteristics using R410A and R22 under the Same Inlet Temperature Condition (동일한 유입온도조건에서 R410A와 R22 적용 응축기의 특성비교)

  • 김창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1049-1059
    • /
    • 2003
  • R410A is considered as an alternative refrigerant to R22 for air conditioners. An experimental investigation was made to study the characteristics of the heat transfer and pressure drop for R410A flowing in a fin-and-tube heat exchanger used for commercial air-conditioning units. Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and refrigerant mass flux varying from 150 to 250 kg/$m^2$s for refrigerant side. The inlet air has dry bulb temperature of 35$^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.6 m/s. Experiments show that air velocity decreased by 16% is needed for R410A than that of R22 for subcooling temperature of 5$^{\circ}C$, which resulted in air-side pressure drop decrease of 15% for R410A as compared to R22. As a consequence, in order to provide the same design condition of a condenser, the fan requires lower electric-power consumption with R410A than that with R22.

Thermal Performance of Air receiver with a Change of Flow direction for Dish Solar Collector (공기식 흡수기의 유동 방향에 따른 $5kW_t$급 접시형 태양열 집열기의 열성능 분석)

  • Seo, Joo-Hyun;Kang, Kyung-Moon;Lee, Ju-Han;Oh, Sang-June;Seo, Tae-Beom
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.182-185
    • /
    • 2008
  • The thermal performance of air receiver with a change of flow direction for dish solar collector. This system is installed and operated in Incheon, Korea. The thermal capacity of the system is about 5 kW thermal. The aperture diameter of the cylindrical-shape receiver which is made of stainless steel is 100 mm, and the height is 210 mm. Experiments are being carried out to investigate the thermal performance variation of the receivers with several design parameters such as the shape of the receiver, the flow directions and the flow rate of air. First, air flows into the upper part of the receiver, which is the opposite side of the aperture. After the air flows through the inside receiver, that goes out of the receiver through 3 exits which are located near the aperture. Second, air flows into the backside of the receiver, Which is the forward side of the aperture. After the air flows through the inside receiver, that goes out of the receiver through 1 exit. The results show that the system efficiency and receiver efficiency increase as the volume flow rate increases as expected.

  • PDF

Removal of PVC from Granular Plastic Mixture by Using Air Table (Air Table을 이용한 입상플라스틱 혼합물로부터 PVC의 건식분리)

  • ;Hiroki Yotsumoto
    • Resources Recycling
    • /
    • v.10 no.6
    • /
    • pp.35-42
    • /
    • 2001
  • A study was conducted in order to remove Poly vinyl chloride (PVC) from granular plastic mixture by using Air Table. The motion of plastic particle on Air Table was investigated, and separation test on the plastic mixture with the mixing ratio of PVC 10% and PE 90% was conducted. At the optimum condition obtained from this study, that is frequency of 9.2Hz, air velocity of 1.05 m/sec, End-slope of $7.5 ^{\circ}$, Side-slope of $1^{\circ}$, Feeding speed of 450 g/min, etc., we could separate the PE-PVC mixture to PE (99.96% grade and 98.9% yield) and PVC (88.7% grade and 99.6% yield).

  • PDF

Comparison of Condenser Characteristics Using R407C and R22 on the Same Inlet Temperature Condition (동일한 유입온도조건에서 R407C와 R22 적용 응축기의 특성비교)

  • 김창덕;전창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.595-603
    • /
    • 2003
  • R407C is considered as an alternative refrigerant to R22 for air conditioners. An experimental investigation was made to study the characteristics of the condensation heat transfer and pressure drop for R407C flowing in a fin-and-tube heat exchanger used for commercial air-conditioning units. Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and refrigerant mass flux varying from 150 to 250 kg/$m^2$s for refrigerant side. The inlet air has dry bulb temperature of 35$^{\circ}C$ , relative humidity of 50% and air velocity varying from 0.8 to 1.6 m/s. Experiments show that air velocity increased by 25% is needed for R407C than that of R22 for subcooling temperature of 5$^{\circ}C$, which resulted in air-side pressure drop increase of 28.8% for R407C as compared to R22. As a consequence, in order to provide the same design condition of a condenser, the fan requires higher electric-power consumption with R407C than that with R22.