• 제목/요약/키워드: Air-guide

검색결과 291건 처리시간 0.026초

수면관통형 터널 프로펠러의 성능해석을 위한 실험적 연구 (An Experimental Study on the Performance of a Surface Piercing Propeller in Tunnel)

  • 정성욱;이승희
    • 대한조선학회논문집
    • /
    • 제43권3호
    • /
    • pp.294-303
    • /
    • 2006
  • A surface piercing propeller (SPP) in tunnel has been proposed recently as a new propulsion system for a high speed air cavity ship. The purpose of the present study is to investigate the characteristics of the SPP in tunnel through a series of model tests. A model propulsion system is placed on a dummy body made of Acrylics. The tunnel is divided into two regions by a guide vane extending from the inlet to the center of the propeller shaft. Air has been supplied from an air nozzle placed at the bottom of the dummy body and the changes in propeller performances caused by the air flow are investigated. The measurements are done for open water and in-tunnel conditions, both for fully and partially submerged propeller. The influence of the guide vane configurations on the propeller performance is also studied. The experiments are performed at the variable pressure circulation water channel of Inha University

다공질 정압공기 베어링을 이용한 직진 테이블에 있어 주위환경이 움직임 정밀.정확도에 미치는 영향 (Influence of the environments on the movement precision of the guide table using externally pressurized porous air bearing)

  • 한응교;허석환;노병옥
    • 대한기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.721-729
    • /
    • 1988
  • 본 연구에서는 직진테이블 시작품을 통해 주위환경에 의한 영향 중 주위온도 에 따른 움직임 정밀 정확도의 변화 및 지지조건이 움직임 정밀.정확도에 미치는 영향 에 대해 실험 연구하였다.

수면관통형 터널 프로펠러의 성능해석을 위한 실험적 연구 (An Experimental Study on the Performance of a Surface Piercing Propeller in Tunnel)

  • 정성욱;이승희
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2007년도 특별논문집
    • /
    • pp.107-117
    • /
    • 2007
  • A surface piercing propeller (SPP) in tunnel has been proposed recently as a new propulsion system for a high speed air cavity ship. The purpose of the present study is to investigate the characteristics of the SPP in tunnel through a series of model tests. A model propulsion system is placed on a dummy body made of Acrylics. The tunnel is divided into two regions by a guide vane extending from the inlet to the center of the propeller shaft. Air has been supplied from an air nozzle placed at the bottom of the dummy body and the changes in propeller performances caused by the air flow are investigated. The measurements are done for open water and in-tunnel conditions, both for fully and partially submerged propeller. The influence of the guide vane configurations on the propeller performance is also studied. The experiments are performed at the variable pressure circulation water channel of Inha University.

  • PDF

쓰레기 자동집하시설 이송배관의 합류관 최적설계 연구 (A Study on the Optimal Design of Confluent Pipe for Waste Collection Piping System)

  • 성순경;박준길;서상호
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.428-432
    • /
    • 2012
  • In the waste collection system, living waste is collected through the piping network. There are many confluent pipes in a piping network. These confluent pipes were often clogged up with waste. The optimal configuration of the confluent pipes has been defined by the design guide. However, nobody know how this design guide were determined. Therefore, in this paper, we found the design data for the confluent pipe configuration in order to avoid the waste clogging in a piping network. The distance between connected point on the confluent pipes should be longer than the previous design guide.

공기를 작동 유체로 하는 열다이오드의 천이 과정중 열성능에 관한 실험적 연구 (An Experimental Study on the Thermal Performance of Air filled Thermal Diode during Transfer Process)

  • 황인주;장영근;박이동;김철주
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 추계학술발표회 논문집
    • /
    • pp.171-175
    • /
    • 1996
  • thermal diode is a device which allows heat to be transferred in one direction by convection due to difference of density of fluid. Vertical plate for heat collection and radiation are of utility for design of thermal diode. It was considered the transient process of air filled thermal diode with guide vane which combined rectangular and parallelogrammic shape enclosures. Gr was kept constantly on 1.60$\times$1010 and error range was $\pm$2% during the experiment. Nu was examined when inclined angle are 15$^{\circ}$and 45$^{\circ}$and, also the experiments was carried out with and without guide vane as well. Specially, The effect of guide vane was sensitive. Developed region inclined angle, which is characteristic of system.

  • PDF

성에제거 덕트 입구 가이드베인 형상이 노즐출구 유량분포특성에 미치는 영향 (Effects of an Inlet Guide Vane on the Flowrate Distribution Characteristics of the Nozzle Exit in a Defrost Duct System)

  • 김덕진;이지근
    • 한국자동차공학회논문집
    • /
    • 제16권4호
    • /
    • pp.88-96
    • /
    • 2008
  • Effects of the duct inlet guide vane on the flowrate distribution characteristics of the defroster nozzle exit in a defrost duct system were investigated experimentally to design the optimum heating, ventilation and air conditioning (HVAC) system applied in an automotive compartment. A 3-dimensional hot-wire anemometer system was used to measure the velocity field in the vicinity of the defroster nozzle jet flow and the velocity distributions near the windshield interior surface. At first, two cases of with- and without-duct inlet guide vanes were considered as the test condition, and then three cases of the duct inlet guide vane were tested to determine the optimum guide vane shape and their positions. The arrangement of the duct inlet guide vanes has an effect on the improved flowrate distribution at the defroster nozzle exit and near the windshield interior surface. However, the application of the lots of guide vane to control the flow direction leads to increase the flow resistance, resulting in the decreased flowrate issuing from the defroster nozzle. The shape of the duct inlet guide vane affects not only the flowrate distribution between the driver side and the assistant driver side but also the reduction of the flow resistance in the defrost duct system.

도류벽 형태에 따른 정수지 내 유동 특성과 소독능 변화에 대한 수치 해석적 연구 (Numerical Analysis for Characteristic of Flow and Disinfection Performance with Variation of Guide Wall in Clearwell)

  • 이석원;박준정;리광훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.767-772
    • /
    • 2006
  • The SWTR(Surface Water Treatment Rule) requires achieving removal 99.9% Giardia and 99.99% Virus. To remove Giardia and Virus, disinfection process is essential process. CT is important index for Disinfection performance. CT value is expressed by CXT. C is represented by disinfection concentration and T is represented by $T_{10}$ which means 90% contact time in clearwell. To improve Disinfection performance, it is desirable to increase $T_{10}$. Primary factor affected $T_{10}$ is flow Pattern. Because guide wall change that flow pattern is uniform, we have installed guide wall to increase $T_{10}$. In this paper, we have performed numerical analysis for clearwell installed symmetric guide wall and center divided guide wall using CFD. We have analyzed flow pattern and $T_{10}$ in each clearwell. And. we compare symmetric guide wall with center divided guide wall in flow pattern and $T_{10}$.

  • PDF

시설물 유지관리를 위한 BIM 데이터 입력기준 개발방안 : 건축 기계설비를 중심으로 (Development Method of BIM Data Modeling Guide for Facility Management : Focusing on Building Mechanical System)

  • 원지선;조근하;주기범
    • 설비공학논문집
    • /
    • 제25권4호
    • /
    • pp.216-224
    • /
    • 2013
  • Facility data is created throughout the design and construction phase. But the most facility managers bear significant costs that arise from the lack of interoperability with facility lifecycle. This paper is concerned with the way to collect facility data using BIM technology. The aim of this paper is to suggest BIM data modeling guide for the facility management using the information that need to be delivered from design and construction phase to operation and management phase. The BIM data modeling guide focus on the properties of mechanical equipment. It is to be hoped that this study will contribute to collect facility data from as-built BIM data and to build facility management system database without difficulty.