• 제목/요약/키워드: Air-guide

검색결과 291건 처리시간 0.023초

Stack Effect Guidelines for Tall, Mega Tall and Super Tall Buildings

  • Simmonds, Peter;Zhu, Rui
    • 국제초고층학회논문집
    • /
    • 제2권4호
    • /
    • pp.323-330
    • /
    • 2013
  • The ASHRAE Technical Committee for Tall Buildings, TC 9.12, has defined a tall building as one whose height is greater than 300 feet (91m). Since the publication of the HVAC Design Guide for Tall Commercial Buildings in 2004, there were only about 300 buildings taller than 200 meters; this number has risen to 600 in 2010 and the prediction 765 buildings taller than 200 meters in 2012. There has also been an introduction of two new classes of tall buildings: ${\bullet}$ Mega tall, which are buildings taller than 300 m, and ${\bullet}$ Super tall, which are buildings taller than 600 m. The effect of ambient air temperature over the height of buildings, especially Mega tall and Super tall buildings. The ambient climatic conditions vary with altitude and these changes in ambient conditions can seriously affect load calculations and performance of super and mega tall buildings. This paper presents revised calculations for stack effect for Tall, Mega Tall and Super tall Buildings.

국가교정검사기관(액체유량)의 측정불확도 평가 및 비교연구 (A Study on the Evaluation of Measurement Uncertainty for the National Calibration and Test Organizations (Liquid Flow))

  • 임기원
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.1012-1019
    • /
    • 2000
  • A proficiency test is one of programs which Korea Research Institute of Standards and Science(KRISS), as national metrology institute, is putting in operation for the mutual recognition arrangement. The Fluid Flow Group of KRISS evaluated the measurement capability for liquid flowmeter calibrator of the national calibration and test organizations. The uncertainty of national standard system was estimated in accordance with Guide to The Expression of Uncertainty in Measurement (ISO), and the turbine flowmeter, which was used for the round-robin test as a reference flowmeter, was characterized. The round-robin tests with the turbine flowmeter package were carried out in 1995 and 1999. The test results of the organizations and those of KRISS agreed within $\pm0.2$%. It is found thus that the organizations have the traceability of the national standard for liquid flow measurement.

  • PDF

熱다이오식 밀폐공간의 熱傳達 特性에 關한 實驗的 硏究 (An Experimental Study on Heat Transfer Characteristics of Thermal Diode Type Enclosure Cavity)

  • 장영근;김석현
    • 설비공학논문집
    • /
    • 제12권12호
    • /
    • pp.1073-1080
    • /
    • 2000
  • Thermal diode is a device which allows heat to be transferred in one direction by convection due to density difference of fluid ,and blocks heat flow in the opposite direction. It is simple in construction and low in cost. And so, it is used as heat collection system of solar energy. In order to acquire a basic design data, thermal diode heat collection system has been studied experimentally for flux Rayleigh numbers from $2\times10^8\;to\;8\times10^8$. The heat transfer rate of this system is shown 10~47% higher than that of other earlier research results. He correlation obtained in this study is Nu=0.0037(Ra^*)^{0.429}(d^*)^{0.05}\frac{(Lr)}{H}^{0.415}$.

  • PDF

고도정수처리(DAF) 정수장 전력설비 적정 설계를 위한 고조파 현장 측정 및 분석 (The diagnosis and analysis for the correct design of electrical system in water treatment plan(Dissolved Air FIotation Process))

  • 김동룡;김기태;한병옥;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.61-63
    • /
    • 2007
  • In these days there are many troubles - system data error, control malfunctions, cable overheating - in water treatment plant. Specially DAF(Dissolved Air Floation Process) plant has high frequency than previous water treatment process. DAF plant has diverse equipment, nonlinear loads for the precise control. But there is no sufficient overall study about harmonics condition of water treatment plant just taking a following partial action without a fundamental solution. On designing of power system, designer should have regard to harmonics condition, but there is no guide reflected harmonics condition on DAF plant This study says what is the result of guideless design about harmonics. With the result of diagnosis and analysis in DAF plant, economical efficiency and safety of plant will be upgraded in the next design.

  • PDF

Cavitation Characteristics of a Pump-turbine Model by CFD Analysis

  • Singh, Patrick Mark;Chen, Chengcheng;Chen, Zhenmu;Choi, Young-Do
    • 한국유체기계학회 논문집
    • /
    • 제18권4호
    • /
    • pp.49-55
    • /
    • 2015
  • The pumped storage plant operates with quick change of the discharge as well as quick changes between pump mode and turbine mode. This study focuses on the cavitation analysis of a pump-turbine model because in turbo-machinery, cavitation can reduce the performance and shorten service life. The pump-turbine model system consists of 7 blades, 20 stay vanes (including tongue) and 20 guide vanes. This study adopts the Rayleigh-Plesset model as a cavitation model, which illustrates cavitation by using the air volume fraction method. The pump mode and turbine mode at the operating condition of partial loading, normal and excessive loading are analyzed to investigate the cavitation performance of the pump-turbine. It was observed that this pump-turbine design showed very good cavitation characteristics with no cavitation bubbles in all operating conditions. Overall value of air volume fraction of both mode at different operating condition are lower than 1, which confirms low possibility of cavitation occurrence at current situation.

에어컨용 직교류홴 시스템의 성능특성에 대한 기본적 설계변수의 영향에 관한 실험적 연구 (An Experimental Study on the Influences of Some Basic Design Parameters on the Performance Characteristics of the Cross-Flow Fan System in Air-Conditioner)

  • 구형모
    • 대한기계학회논문집B
    • /
    • 제23권6호
    • /
    • pp.695-702
    • /
    • 1999
  • A cross-flow fan which constitutes a fan-duct system with a stabilizer and a scroll-casing is widely used in many air-ventilating and air-conditioning devices. The cross-flow fan system has many design parameters which have crucial influence on the performance and the noise characteristics of the devices, which means many difficulties during the design stage of the devices and the general design guide has not sufficiently established yet. This study presents the experimental results of the parameter investigation of some chosen design parameter values, which are the shapes of the stabilizers, the profiles of the scroll casing part, and the diffusion angles of the flow exit. The results are expressed by the varying performance characteristics with the values of the parameters. They are found to have considerable effects on the system performance and should be considered with care in the design stage. Finally some helpful guides for the design and manufacturing of the cross-flow fan system are proposed.

Decoupled Type의 초정밀 이중 서보의 제어에 관한 연구 (Control of Decoupled Type High Precision Dual-Servo)

  • 남병욱;김기현;최영만;김정재;이석원;권대갑
    • 한국정밀공학회지
    • /
    • 제23권2호
    • /
    • pp.43-50
    • /
    • 2006
  • Recently, with rapid development of semiconductor and flat panel display, the manufacturing equipments are required to have large travel range, high productivity, and high accuracy. In this paper, an ultra precision decoupled dual servo (DDS) system is proposed to meet these requirements. And a control scheme for the DDS is studied. The proposed DDS consists of a $XY{\Theta}$ fine stage for handling work-pieces precisely and a XY coarse stage for large travel range. The fine stage consists of four voice coil motors (VCM) and air bearing guides. The coarse stage consists of linear motors and air bearing guides. The DDS is mechanically decoupled between coarse stage and fine stage. Therefore, both stages must be controlled independently and the performance of the DDS is mainly determined by the fine stage. For high performance tracking, the controller of fine stage consists of time delay control (TDC) and perturbation observer while the controller of coarse stage is TDC alone. With these individual controllers, two kinds of dual-servo control strategies are suggested: master-slave type and parallel type. By simulations and experiments, the performances of two dual-servo control strategies are compared.

유도형 로켓탄의 시험평가 방법에 관한 연구 (Study on Methods in Test & Evaluation of the Guided Rocket Munition)

  • 안만기;권택만;황운희;황우열
    • 한국군사과학기술학회지
    • /
    • 제13권6호
    • /
    • pp.1019-1025
    • /
    • 2010
  • This paper describes on methods in test and evaluation of the guided rocket munitions of the domestic new generation multiple launcher rocket system. We modified and refer to the present model of air-to-air missile(AAM) and surface-to-air missile(SAM). Also we suggested a method of surface-to-surface missile(SSM) based on the characteristics of the guided rocket in test and evaluation(T&E). According to this study, the suggested activity of T&E should be observed methods compatible with each item on the established model. Therefore, we expect that the proposed research material will be a good guide to the study of a surface-to-surface missile(SSM) installed GPS/INS integration navigation guidance & control systems in the future.

차량용 공조 팬의 소음 저감에 대한 실험적 연구 (Experimental Study on Noise Reduction of Fan for Automotive Air Conditioner)

  • 이진갑;정병훈
    • 한국산학기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.51-56
    • /
    • 2013
  • 본 논문은 철도 차량에 사용하는 라인 플로우 팬의 소음 저감을 위해 소음원을 규명하여 저감하는 실험적인 연구이다. 라인 플로우 팬의 소음은 공기 유동에 의한 난류성 유동 및 랜덤성 소음, 블레이드 통과 주파수(681Hz)의 소음, 모터 회전에 의한 로터의 불균형(28.4Hz)의 구조물 진동에 의한 소음 등 여러 요인에 의해 발생된다. 각각의 소음원에 대해 대책을 수립하여 하우징 가이드 각도 및 거리 조정, 유동 통로의 형상 변경, 로터 밸런싱을 통해 총 5.7dB(A)의 소음을 저감하였다.

승객 수에 따른 전동차 객실공간의 온도변화 특성 연구 (A Study on the Temperature Variation Characteristics of Electric Car Depending on Passenger Number)

  • 함대주;박덕신;남성원;맹희영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.393-399
    • /
    • 2008
  • A Study has been conducted on the characteristics of temperature variation depending on passenger number that is measured in Bundang Line(From Sunleng To Bojong). As a basic study, the air quality of passenger room for the electric rail car is evaluated. Although ISO7730 recommends that the height of measuring points for the heat environment is to set at 0.1m, 0.6m, 1.1m and 1.7m respectively, temperature are measured at two points at 1.1m and 1.7m because of the difficulty to measure temperature of 0.1m height in rush hour. We compared the results of temperature variations between two stations in rush hour(07:56-08:41). In general, the capacity of a passenger car is designed for 160 persons, but over 280 persons often board on electric rail in rush hour. The temperature of room is adjusted from $22^{\circ}C$ to $24^{\circ}C$, but it is measured from $26^{\circ}C$ to $28^{\circ}C$ on average. Therefore, it shows that there are difference between the set temperature and measured one. This article suggests the ways of the time adjusting and air-conditioning to satisfy customer's demand and the guide line to design the optimum capacity of air-conditioner of the new electric rail car which will be introduced in the near future.

  • PDF