• 제목/요약/키워드: Air-distribution System

검색결과 961건 처리시간 0.028초

시스템 성능 지수 및 동적 전력분산 제어를 통한 무선센서를 이용한 에어컨 네트워크 시스템의 성능 개선 (Performance Improvement of Air Conditioner Network System using Wireless Sensors Through System Performance Index and Dynamic Power Distribution Control)

  • 최호식;권우현;윤병근
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.64-70
    • /
    • 2019
  • Wireless sensors have been developed in numerous ways for enhancing the convenience of installation, management and maintenance of sensors. Energy harvesting wireless sensors, which can collect energy from the external environment for permanent usage without the need of recharging and exchanging batteries, have been developed and employed used in Internet of Things and at various industrial sites. Energy harvesting wireless sensors are significantly affected by the sensor lifespan to sudden variation in the external environment. Furthermore, reduction in the sensor operating timespan can greatly affect the characteristics of the devices connected through a network. In this paper, a system performance index is proposed that can comprehensively evaluate the lifespan of a solar cell wireless sensor, determine the characteristics of devices connected to the associated network, and recommend dynamic power distribution control for improving the system performance index. Improvement in the system performance index was verified by applying the proposed dynamic power distribution control to an air conditioner network system using a solar cell wireless sensor. Obtained results corroborate that the dynamic power distribution control can extend the lifespan of the incorporated wireless sensor and reduce the air conditioner's power consumption.

Helium guard system design for HIAF iLinac cryogenic distribution system

  • Xianjin Wang;Shuping Chen;Wen Jun;Dajun Fan;Liming Zhu;Yanan Lib;Xiaofei Niu;Junhui Zhang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권1호
    • /
    • pp.6-10
    • /
    • 2023
  • 2 K superfluid helium cryogenic system is the crucial component of many large accelerators. When the cryogenic system is operating at 2K@3129Pa, many room-temperature parts are connected to superfluid helium via tubes. Air Leakage in these connections may lead to air contamination of the cryogenic system. Air contamination may cause equipment failure in cryogenic systems and, in extreme cases, render the entire accelerator system inoperable. Helium guard is a technique that guards against air contamination of these sub-atmospheric pressure connections in 2 K superfluid helium cryogenic system. This paper introduces a typical 2 K cryogenic distribution design for large accelerators, and make risk analysis of air contamination. Finally, the analysis of specific leakage points and detailed engineering design are presented, which may be used as a reference when designing of a 2 K superfluid helium cryogenic distribution system.

공동주택 적용을 위한 다분기챔버 환기 시스템의 성능평가에 관한 연구 (Performance Evaluation of Multidrop Chamber Ventilation System in Apartment)

  • 김성수;손장열
    • KIEAE Journal
    • /
    • 제9권4호
    • /
    • pp.17-22
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system. The experiments were designed to simulate apartment of $84m^2$ and established multidrop chamber duct and general duct on the ceiling of the apartment. Distribution performance of air supply rate were evaluated in this experiments. As a result, distribution performance of air supply rate in the general duct is different from designed air supply rate by about 35% ~ 50% and about 10% in the multidrop chamber system. In additional the sound insulation performance of the multidrop chamber system decreased about 20% compared with general duct system. Therefore, the multidrop chamber system is considered to satisfy proper air supply rate of each room and to improve the sound insulation performance in apartment Houses.

주거 환기 시스템의 공기 분배 성능 개선 방안 (A Method for Improving Air Distribution Performance at the Residence Ventilation System)

  • 박은준;김용봉;나희형;이상기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.589-593
    • /
    • 2007
  • In the mechanical ventilation system, it is a fundamental condition to distribute the air equally to the each room. In this study, distribution performance of the air distributor which generally connected to a circular duct was investigated by simulation and experiment. In the first CFD analysis, maximum air flow rate deviation was an 63% in the air distributor model. After numbers of model modification and simulation, maximum flow rate deviation was reduced to 19% in the final simulation model. An air distributor which used in the experiment was produced by using data obtained from the final analysis. When experimental result was compared with analysis result, there was a deviation difference as much as 9%.

  • PDF

바닥공조시스템에서 복사온도가 열적 쾌적성에 미치는 영향 (Effect of Radiative Mean Temperature on Thermal Comfort of Underfloor Air Distribution System)

  • 정재동;홍희기;유호선
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.711-717
    • /
    • 2008
  • Despite the fact that UFAD(Under Floor Air Distribution) systems have many benefits and are being applied in the field in increasing numbers, there is a strong need for an improved fundamental understanding of several key performance features of these systems. This study numerically investigates the effect of supplied air temperature and supplied flow rate on the performance of UFAD, especially focused on thermal comfort. Also this study has compared UFAD with conventional overhead air distribution system. In contrast to the well-mixed room air conditions of the conventional overheat system, UFAD system produces an overall floor-to-ceiling airflow pattern that takes advantage of the natural buoyancy produced by heat sources in the occupied zone and more efficiently removes heat loads and contaminants from the space. Thermal comfort parameters were evaluated by CFD approach and then PMV was computed to detect the occupants' thermal sensation. Results show that radiative mean temperature plays crucial role on the evaluating PMV. Until now, the radiative temperature has been the missing link between CFD and thermal comfort, but the present study paves the way for overcoming this weakness.

철도 차량의 HVAC 위치에 따른 공기조화 시스템 및 Air Duct 구조의 특성에 관한 고찰 (A Survey for the Air Treatment System according to the Position of HVAC and the Feature of Air Duct Structure in the Train)

  • 정화식;박재홍;염규학
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1330-1335
    • /
    • 2007
  • The HVAC and the air duct is to make optimal indoor environment. By the HVAC position, method and the air duct construction, the important elements can affect on cooling performance, passengers' convenience, and energy efficiency. According to this, there are features, such as the indoor temperature distribution, cooling performance, velocity distribution from diffuser, tend to be come out variously. Also, comparing and analysing temperature distribution, cooling performance, air velocity, noise based on the real practical vehicle tests, it shows features in detail. Besides, it can lead to make design the system of HVAC & air duct effectively.

  • PDF

빙축열을 이용한 저온급기/급수 냉방 시스템 (Cold Air/Water Distribution System with Ice Storage)

  • 김경훈;이종원
    • 대한설비공학회지:설비저널
    • /
    • 제20권2호
    • /
    • pp.125-133
    • /
    • 1991
  • This paper presents some design guidelines for using cold air/water distribution to cool commercial and industrial buildings. Cold air /water distribution systems provide primary air/water for space conditioning at nominal temperature between $3^{\circ}C$ and $10^{\circ}C$ ($4{\sim}5^{\circ}C$ might be recommendable for better selection). By using lower temperature primary air/water equipment could be downsized, means lower first costs, and often reduce annual energy costs up to 50% less than that of the conventional ($13^{\circ}C$) system. This concept takes full advantages of the $2{\sim}4^{\circ}C$ chilled water (brine) available with ice storate systems.

  • PDF

전력공조시스템의 $CO_2$ 배출특성에 관한 연구 (A Study on the Characteristics of $CO_2$ Emissions for an Electric Powered Air Conditioning System)

  • 장영근;김석현
    • 설비공학논문집
    • /
    • 제14권5호
    • /
    • pp.433-440
    • /
    • 2002
  • Simulations were carried out to investigate the characteristics of $CO_2$ emissions for an electric powered air conditioning system. The $CO_2$ emissions were evaluated for various simulation parameters such as a power source distribution rate, power plant efficiency, power supply efficiency and system performance (COP). It was found that the $CO_2$ emissions were remarkably decreased by increasing the COP of the electric powered air conditioning system with storage tank. The $CO_2$emission per unit refrigeration capacity is 0.6 kg/RTh. And also, as the COP increase by 0.1, the $CO_2$ emissions decrease by 7.2%.

돔경기장의 급배기방식에 따른 기류분포 및 실내온도 특성 (The Characteristics of Indoor Temperature and Airflow Distribution for Air Supply and Return System in Dome Stadium)

  • 채문병;양정훈;석호태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.434-439
    • /
    • 2008
  • Dome stadiums give thermal unpleasant feeling to occupants because of the radiant heat and the indoor and outdoor haet exchange from roogs or lightweight building envelopes of sidewalls. This study analyzed the indoor temperature and velocity distribution according to various air supply and return sustems in dome stadiums in summer.

  • PDF

고강도콘크리트의 동결융해저항에 미치는 기포조직의 영향 (Effect of Air Void System of High Strength Concrete on Freezing and Thawing Resistance)

  • 김생빈
    • 콘크리트학회지
    • /
    • 제4권1호
    • /
    • pp.89-96
    • /
    • 1992
  • 콘크리트의 내동해성은 일반적으로 공기량이나 기포조직 및 분포에 따라 크게 영향을 받으며 콘크리트의 강도와도 관련이 있는 것으로 알려져 있다. 본 연구에서는 고강도콘크리트의 동결융해 저항성에 미치는 공기량 및 기포조직 특히 간격계수의 영향에 관한 실험적 연구로서 우선 압축강도는 Non-AE콘크리트를 대상으로 400-500kg/$\textrm{cm}^2$를 목표로 하였고, 실험결과 내구성지수가 10~20%정도에 불과하므로 다음단계로 공기량 2~12%인 AE콘크리트로 하여 내구성 향상을 도모하였다. 이 때 단위시멘트량, 물\ulcorner시멘트비등을 변화시킨 20종류의 콘크리트 배합에 대해 500cycle까지 동결융해시험을 실시하였다. 결론적으로 동결융해의 저항성은 물\ulcorner시멘트비 보다는 공기량과 더 밀접한 관계가 있었고 임계내구성지수에 대응하는 간격계수는 물\ulcorner시멘트비에 따라 다르다는 사실을 알 수 있었다.