• 제목/요약/키워드: Air-conditioning system

검색결과 3,315건 처리시간 0.032초

건축 공간적 가변성에 대응하는 설비 시스템에 관한 연구 (Research and study on facility system good enough to address the changing aspects of building space)

  • 이재용;윤해동;김석완
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.554-559
    • /
    • 2006
  • The currently common housing is obviously going to be under the reconstruction in just $20{\sim}30$ years, with the failure to satisfy the improvement of national income, diversification and advance of national demand. But, reckless and random reconstruction Induce the serious problem of environmental pollution involving the loss of national treasury and excess materials of constructions. In order to address such problem, the common housing of longevity, which can adequately cope with the changes of times and tastes of inhabiters, in the future, is arising as an alternative. Recently, the groundbreaking phase of common housing is also being considered as another alternative to resolve such problem. The common housing of longevity has an advantage to create a free and comfortable space in accordance with the tastes of inhabiters, as well as expanding the durability of building. But, the current facility system has an inability to deal with the sort of housing. Thus, the research paper is designed to make an analysis on problems of common housing in South Korea, which has made it difficult to handle a changing space, and based on the analysis, the paper is intended to make a review on the future-oriented facility service appropriate enough to deal with the changing aspects of space.

  • PDF

냉동시스템 고장 진단 및 고장유형 분석을 위한 3단계 분류 알고리즘에 관한 연구 (A study on the 3-step classification algorithm for the diagnosis and classification of refrigeration system failures and their types)

  • 이강배;박성호;이희원;이승재;이승현
    • 한국융합학회논문지
    • /
    • 제12권8호
    • /
    • pp.31-37
    • /
    • 2021
  • 산업의 발전으로 도시화로 인해 건물의 규모가 커지면서, 건물의 공기 정화 및 쾌적한 실내 환경을 유지의 필요성 또한 증가하고 있다. 냉동 시스템의 모니터링 기술의 발전으로 건물 내에 발생하는 전력 소모량을 관리할 수 있게 되었다. 특히 상업용 건물에서 발생하는 전력 소모량 중 약 40%가 냉동 시스템에서 일어난다. 따라서 본 연구 냉동시스템 고장진단 알고리즘을 개발하기 위해서 냉동시스템의 구조를 이해하고, 냉동 시스템의 운영과정에서 발생하는 데이터를 수집 분석하여 다양한 유형과 심각도를 가지는 고장 상황을 조기에 신속하게 탐지 분류하고자 하였다. 특히 분류가 어려운 고장 유형들의 분류 정확도를 향상시키기 위하여 3단계 진단 및 분류 알고리즘을 개발하여 제안하였다. 다수의 실험과 초모수 (hyper parameter) 최적화 과정을 거쳐 각 단계에 적합한 분류 모형으로 SVM과 LGBM에 기반 한 모형을 제시하였다. 본 연구에서는 고장에 영향을 미치는 특성을 최대한 보존하면서, 선행연구에서 어려움을 겪었던 냉매 관련 고장을 포함한 모든 고장 유형을 우수한 결과로 도출하였다.

남부지역의 태양열이용 열펌프식 온수.난방시스템의 실증연구 분석 (Analysis of demonstration research on solar heat pump system for room and hot water heating in the southern part of South Korea)

  • 선경호;김기선
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.198.1-198.1
    • /
    • 2010
  • 우리나라 남부지방은 대체적으로 태양 일사량이 풍부하여 태양열 시스템의 설치조건으로는 가장 좋은 지역이다. 현재까지 국내에 보급된 태양열 시스템은 외기조건이 불량한 경우에는 비효율적이다. 최근 태양열 온수기는 전국적으로 매우 활발히 보급되고 있고 태양열 온수기에 대한 일반인들의 인식은 그 어느 때보다 높다고 할 수 있다. 태양열이용 열펌프시스템 기술은 소형 온수기에의 적용 뿐 아니라 건물의 난방기술에도 적용되고 있다. 본 연구에서는 태양열 집열기 직접 팽창식 열펌프시스템(이하 '태양열 시스템')의 열성능 효율 향상에 가장 많이 기여하는 팽창장치와 롤본드형 태양열집열기에 대하여 실험하였고 현장 적용가능성을 분석하였다. 또한 태양열 열펌프식 온수 및 난방시스템의 한국의 남부지방에서의 적용가능성은 지난 관련연구결과를 분석하여 비교하여 모색하였다.

  • PDF

차량 내부 탑승자의 쾌적성 평가를 위한 초기 냉방운전 성능에 대한 수치해석적 연구 (Numerical Analysis on the Initial Cool-down Performance Inside an Automobile for the Evaluation of Passenger's Thermal Comfort)

  • 김윤기;양장식;백제현;김경천;지호성
    • 한국자동차공학회논문집
    • /
    • 제18권5호
    • /
    • pp.115-123
    • /
    • 2010
  • Cool-down performance after soaking is important because it affects passenger's thermal comfort. The cooling capacity of HVAC system determines initial cool down performance in most cases, the performance is also affected by location, and shape of panel vent, indoor seat arrangement. Therefore, optimal indoor designs are required in developing a new car. In this paper, initial cool down performance is predicted by CFD(computational fluid dynamics) analysis. Experimental time-averaging temperature data are used as inlet boundary condition. For more reliable analysis, real vehicle model and human FE model are used in grid generation procedure. Thermal and aerodynamic characteristics on re-circulation cool vent mode are investigated using CFX 12.0. Thermal comfort represented by PMV(predicted mean vote) is evaluated using acquired numerical data. Temperature and velocity fields show that flow in passenger's compartment after soaking is considerably unstable at the view point of thermodynamics. Volume-averaged temperature is decreased exponentially during overall cool down process. However, temperature monitored at different 16 spots in CFX-Solver shows local variation in head, chest, knee, foot. The cooling speed at the head and chest nearby panel vent are relatively faster than at the knee and foot. Horizontal temperature contour shows asymmetric distribution because of the location of exhaust vent. By evaluating the passenger's thermal comfort, slowest cooling region is found at the driver's seat.

성층 축열 시스템에서의 열 저장 특성에 관한 실험적 연구 (An experimental study on thermal storage characteristics in the thermally stratified water storage system)

  • 고재윤;김영기;이채문;임장순
    • 한국태양에너지학회 논문집
    • /
    • 제21권4호
    • /
    • pp.37-46
    • /
    • 2001
  • This study describes the experimental study that focuses on the effects that distributor shapes and flow rate variations have an influence on the stratification in a rectangular thermal storage tank. Experiments were carried out under the conditions that the flow rates of working fluid are 20, 10 and $5\ell$/min. The storage tank is initially filled with chilled water of $1^{\circ}C$, and is extracted through the bottom at the same rate as the return warm water from load is entered through the distributor at the top of the tank. The thermo-cline forms at the top of the storage tank as the warm water enters the tank from the load through the distributor and the thermo-cline thickness increases with time. Emphasis is given to the effects of mixing at the inlet that increases the thermo-cline decay Flow rate variation and inlet distributor shapes are the important parameters in deciding the performance of a storage system. Stratification degree increases with decreasing in inlet flow rate under $10\ell$/min. Experiments shows that better thermal stratification can be obtain using the distributor to limit momentum mixing at the inlets and outlets. Also, 12% of improvement in the thermal energy usage has been achieved using the modified distributor discharging same flow rate in each lateral ports.

  • PDF

단프라시트를 적용한 간접식 증발냉각 장치의 냉각 성능 예측 (Prediction of Cooling Performance for Indirect Evaporative Cooling System Using Danpla Sheet)

  • 김명호;김병재
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.892-897
    • /
    • 2020
  • 본 연구에서는 간접식 증발냉각 장치의 냉각 성능을 예측하고 다양한 공기 유량 및 물 분무 유량 조건을 만족하는 성능 상관식을 제안한다. 기존의 플라스틱 열교환기는 공조 공간의 크기에 따라 금형을 새로 제작해야 하기 때문에 높은 효율에도 불구하고 잘 사용하지 않았다. 한편 단프라시트는 일반적으로 두께가 얇아 열교환이 우수하고, 특히 제작이 매우 용이하다. 따라서 열교환기를 단프라시트로 제작할 경우 금형이 별도로 필요하지 않아 열교환기 제작 비용을 크게 절감할 수 있다. 이에 본 연구에서는 단프라시트로 다채널 열교환기를 제작하여 간접식 증발냉각 장치를 제작하였다. 성능 실험장치는 열교환기, 물 분사 노즐, 터보홴, 항온조, 순환 펌프, 온도 센서, 습도 센서, 차압식 유량계 및 자료획득 장치로 구성하였다. 증발냉각 시 공기 유량이 증가하면 유용도가 감소하였고, 수공비에 따라 유용도 최적점이 존재하였다. 등온 조건에서 냉각 성능을 예측하는 상관식과 실내 환기 온도와 외기 상태를 반영하는 성능 상관식을 제안하였다. 상관식들의 냉각 성능 오차는 4 % 이내였다.

가정에서의 열에너지 관리 현황조사 연구 -서울 지역을 중심으로- (An Exploratory Study of Energy Consumption and Management in the Home)

  • 윤복자
    • 대한가정학회지
    • /
    • 제18권1호
    • /
    • pp.67-82
    • /
    • 1980
  • The objectives of the study were to determine 1) energy uses for residential requirements, 2) if energy consumption and adoption of energy conservation attitudes and practices vary with independent variables family size, stage of family life cycle, homemaker's level of education, income, heating system, and number of electrical household items, and 3) if there is a correlation between energy conservation attitudes and practices. Questionnaires were given to the randomly selected homemakers I Seoul in the summer (September, 1979) and the winter (February, 1980). Analysis of variance and correlation were used to analyzed the data which consisted of 537 usable responses of 895 returned in the summer and 554 responses of 794 returned in the winter. The results are as follows: 1) The order of consumption rate of the direct energy uses for residential requirements was found to be heating and air conditioning, cooking, refrigeration, T.V., lighting, and miscellaneous. 2) Energy consumption and adoption of energy conservation attitudes and practices were significantly related to family size, homemaker's level of education, and the stage of family life cycle. (1) Families of five members revealed higher scores in attitudes and practices than families less than five or more than six. (2) The higher the homemaker's level of education, the more energy consumption and the higher scores I attitudes and practices were found. (3) Families in the middle stage of family life cycle tend to use more energy than younger or older families, but their scores in attitudes and practices were high. 3) There was a significant correlation between energy conservation attitudes and practices. However, the scores of the conservation practices were not as good as the attitudes. It may be attributed to either a lack of knowledge and/or financial difficulties, or a dissonance between the concept and implementation of energy conservation. 4) Recommendations for the energy-saving and energy-related public policies are: (1) to use such human resources as attitudes, values, feelings of agreement, and cooperation, as well as nonhuman resources for the energy conservation, (2) to develop a educational program and a creative system I order to implement energy conservation programs, and (3) to consider direct as well as indirect energy uses I selecting goods and services.

  • PDF

고분자물질 및 계면활성제의 유동마찰 저감 특성 비교 연구 (A Comparison Study on Flow-Friction Characteristic of Polymer Solution and Surfactant as Drag Reduction Additive)

  • 하재순;유재성;김성수;조성환;윤석만;엄재식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.863-868
    • /
    • 2009
  • The drag reduction(DR) for Betaine+Amin and Xantan Gum as kinds of surfactant and Polyacrylamide as kinds of polymer solution according to the fluid velocity, temperature and surfactant concentration were compared experimentally. For this study, two kinds of experimental apparatus for short time and long time measurement were established. Each experimental appratus was equipped with hot water storage tanks, pumps, testing pipe network, flowmeter, two pressure gauges and data logging system was built for them. Results showed that Betaine+Amin and Xanthan Gum as kinds of surfactant had appeared optimal DR around 200-500 ppm and their DR tended to be decreased when flow velocity increased but Polyacrylamide as kinds of polymer solution showed the opposite trend to be increased when flow velocity increased. The both of them showed above 40% DR in the case of better condition by the short term measurement. But Polyacrylamide as kinds of polymer solution showed more degradation than Betaine+Amin and Xanthan Gum as kinds of surfactant by the long term measurement. As a result, Betaine+Amin and Xanthan Gum as kinds of surfactant showed better materials to use to the district heating system.

  • PDF

판형 열교환기의 열전달과 유동특성에 대한 연구 (Study on Characteristics of Heat Transfer and Flow in Plate Heat Exchanger)

  • 김진화;이광성;지명국;정한식;정효민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1476-1483
    • /
    • 2009
  • In present work, experiments conducted to investigate the heat transfer characteristics and relationship between operating parameters and production of fresh water as output of the system. Plate Heat Exchanger (PHE) applied in vacuum evaporator for product fresh water that system intended to efficiently use low grade heat. PHE have become popular in chemical, power, food and refrigeration industries due to the efficient heat transfer performance, extremely compact design and flexibility of extend or modify to suit changed duty. The heat transfer part contains corrugated plates with 60 degree of chevron angle which verified by many researchers and commonly apply. Fresh water can be produced from saline water under near vacuum pressure by operating ejector. Consequently, evaporating temperature stay around $51-57^{\circ}C$ so it is possible to use any low grade heat source or renewable source. The maximum fresh water produced by freshwater generator with plat heat exchanger applied in the study was designed as 1.0 Ton/day.

  • PDF

Evaluation of Rainwater Utilization for Miscellaneous Water Demands in Different Types of Buildings Using Geographic Information System

  • Kim, Jinyoung;An, Kyoungjin;Furumai, Hiroaki
    • Environmental Engineering Research
    • /
    • 제18권2호
    • /
    • pp.85-90
    • /
    • 2013
  • This study is an attempt to quantify rainwater utilization and miscellaneous water demand in Tokyo's 23 special wards, the core of the urban area in Tokyo, Japan, in order to elucidate the potential of further rainwater utilization. The rainwater utilization for miscellaneous appropriate water demands, including toilet flushing, air conditioning, and garden irrigation, were calculated for six different types of building: residential house, office, department store, supermarket, restaurant, and accommodation. Miscellaneous water demands in these different types of building were expressed in terms of equivalent rainfall of 767, 1,133, 3,318, 1,887, 16,574, and 2,227 (mm/yr), respectively, compared with 1,528 mm of Tokyo's average annual precipitation. Building types, numbers and its height were considered in this study area using geographic information system data to quantify miscellaneous water demands and the amount of rainwater utilization in each ward. Area precipitation-demand ratio was used to measure rainwater utilization potential for miscellaneous water demands. Office and commercial areas, such as Chiyoda ward, showed rainwater utilization potentials of <0.3, which was relatively low compared to those wards where many residential houses are located. This is attributed to the relatively high miscellaneous water demand. In light of rainwater utilization based on building level, the introduction of rainwater storage mechanisms with a storage depth of 50 mm for six different types of buildings was considered, and calculated as rainfall of 573, 679, 819, 766, 930, and 787 (mm), respectively. Total rainwater utilization using such storage facilities in each building from 23 wards resulted in the retention of 102,760,000 $m^3$ of water for use in miscellaneous applications annually, and this volume corresponded to 26.3% of annual miscellaneous water demand.