• 제목/요약/키워드: Air-Surface exchange

검색결과 108건 처리시간 0.027초

열펌프 시스템의 규모 결정을 위한 온돌난방부하 특성 (Characteristics of Ondol Heating Load for the Determination of Heat Pump Power)

  • 노정근;백은기;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제28권3호
    • /
    • pp.217-224
    • /
    • 2003
  • To find out heating load and to determine the power of heat pump compressor for the Ondol room heating the COP of heat pump, the variation of Ondol room air temperature, the variation of ambient temperature and power consumption of heat pump are analyzed. The results from this study were summarized as follows: 1. The COP of the heat pump in close loop decreased as the ambient air temperature. The COP was 2.26 when the temperature difference of condenser was $20\pm3^{\circ}C$. 2. The Ondol surface temperature was $25\pm3^{\circ}C$ when the hot water of $40^{\circ}C$ was supplied from hot water storage tank to the Ondol and the temperature difference between the Ondol surface and the room air temperature was $7~8^{\circ}C$. 3. The ratio of thermal conduction heating load to total heating load in Ondol heating space was found to be 83% and ratio of ventilation heating load was 17%. Therefore, the thermal conduction heating load was confirmod to be a major heating load in Ondol heating space. 4. In case of the ambient temperature of $3.2^{\circ}C$, the efficiency of heat exchange of Ondol heating system was 85%. 5. The heating load per Ondol heating surface area and volume of Ondol room space were theoretically analyzed. In case of the room temperature of $20^{\circ}C$ and the ambient temperature of $-3.2~3.8^{\circ}C$, the heating load per Ondol surface area was 115.8~167.6kJ/h ㆍ㎥ and per Ondol mom space volume was 50.2~72.7kJ/h ㆍ㎥. 6. The compressor power of heat pump fur the Ondol room heating could be determined with the heating load analyzed in this study In case of the Ondol room air temperature of 17~2$0^{\circ}C$ and the ambient temperature of -5~3.8$^{\circ}C$, the compressor power of heat pump per Ondol surface area was analyzed to be $2.3\times10^{-2}psm^2$, and per volume of Ondol room space $1.0\times10^{-2}1.4\times10^{-2}ps/m^2$ps.

건축외부공간에 있어서 인체의 일사열부하(日射熱負荷) 및 열적(熱的) 쾌적성(快適性)에 관한 실험적 연구 (Human Solar Heat Load and Thermal Comfort in an Outdoor Environment)

  • 정창원;윤인
    • 한국산업융합학회 논문집
    • /
    • 제1권2호
    • /
    • pp.65-74
    • /
    • 1998
  • The purpose of this paper is to investigate the mount of relief of human solar heat load and thermal comfort in outdoor environment in summer, Six different types of sites, T garden and its neighboring area in Japan, were selected as the experiment sites. The experiments were conducted from 22 to 29 August, 1994 to find the relationship between climatic conditions and human responses, Climatic conditions, subjects's thermal sensation and skin temperature were measured. Radiant heat exchange on the human body was estimated on the basis of the measured air and surface temperature and solar radiation. Thermal index Operative Temperature and New Effective Temperature was modified with the effect of the radiant heat exchange. Human thermal comfort and skin temperature is affected by the solar radiation and the sky factor in an outdoor environment. The effect of tree shade was verified on thermal comfort, The mount of relief of human solar heat load is relation to the existence of shade a solar radiation and the sky factor. The urban garden is one of the effective design element in an urban environmental planning.

  • PDF

중온형 고체산화물 연료전지를 위한 YSZ 전해질에서의 고성능 공기극 연구 (Study on high performance cathode on YSZ electrolyte for intermediate-temperature solid oxide fuel cells(IT-SOFC))

  • 이창보;배중면
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.368-371
    • /
    • 2006
  • [ $La_{0.8}Sr_{0.2}Co_{1-x}Mn_xO_3$ ] cathode as a high performance cathode on YSZ electrolyte was studied by analyzing impedance spectra. It was shown that cathode property of $La_{0.8}Sr_{0.2}Co_{1-x}Mn_xO_3$ is bet ter than that of$La_{0.8}Sr_{0.2}CoO_3$. At $700^{\circ}C$ in air environment, $La_{0.8}Sr_{0.2}Co_{0.4}Mn_{0.6}O_3$ cathode on CGO- layered YSZ electrolyte showed very low area specific resistance of $0.14{\Omega}cm^2$, which is low enough for intermediate-temperature sol id oxide fuel cells. This is because material properties of ionic conductivity and thermal expansion compatibility with electrolyte were optimized. Judging from activation energy and oxygen part i al pressure dependance of cathode property, it was noted that oxygen surface exchange kinetics is dominantly influential on cathode property in higher temperature region than $700^{\circ}C$ and oxygen self-diffusion in cathode material is more influential in lower temperature region.

  • PDF

The Exchange of Reduced Sulfur Gases Across the Atmosphere-Teerrestrial Biosphere Interface

  • Kim, Ki-Hyun;Zhen Yand;Shiming Wang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제12권E호
    • /
    • pp.1-18
    • /
    • 1996
  • In this review, the significance of terrestrial ecosystems in the global sulfur budget has been reviewed based on the currently available databases covering the topic. In the section 1, we describe our current understanding of natural sulfur cycle in relation to most well-known natural reservoir, oceanic environment. The sections 2 and 3 provide the fundamental pictures of the rerrestrial sulfur cycle with respect to the relative importance of its individe the fundamental pictures of the terrestrial sulfur cycle with respect to the section 3, previously reported flux values for several major sulfur gases are presented for each reservoir and are intercompared to derive representative fluxes for the respective environment. In the section 4, source mechanisms for volatile sulfur species are dealt for both microscale and macroscale processes leading to their productions. In the section 5, environmental factors controlling the exchange of biogenic sulfur gases across the air-surface have been discussed. In the section 6, environmental fate of sulfur gases released into the atmosphere has been described. Finally in tie section 7, as concluding remarksm we discuss directions and suggestions to overcome various limitations encountered from previous measurement investigations of natural sulfur cycle in diverse natural ecological systems.

  • PDF

EGR Cooler에 CNC 첨가시 열교환 특성에 관한 연구 (A Study on the Heat Exchange Characteristics of EGR-Cooler with CNC)

  • 이병호;이중섭;김보한;정효민;정한식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.847-853
    • /
    • 2008
  • Although combustion is essential in most energy generation processes, it is one of the major causes of air pollution. Circle fin exhaust pipes were designed to study the effect of cooling the recirculated exhaust gases (EGR) of Diesel engines on the chemical composition of the exhaust gases and the reduction in the percentages of pollutant emissions. The designs adopted in this study were exhaust pipes with solid and hollow fins around them direct surface force measurement in water using a nano size colloidal probe Technique The direct force measurement between colloidal surfaces has been an essential topic in both theories and applications of surface chemistry. As particle size is decreased from micron size down to true Carbon nano Colloid size (<10nm), surface forces are increasingly important. Nanoparticles at close proximity or high solids loading are expected to show a different behavior than what can be estimated from continuum and mean field theories. This paper use Water and CNC fluid at normal cooling system of EGR. Experimental result showed all good agreement at Re=$2.54{\times}10^{4}$.

WRF 모형의 수도권 지역 상세 국지 기상장 모의 성능 평가 (Performance Evaluation of the High-Resolution WRF Meteorological Simulation over the Seoul Metropolitan Area)

  • 오준서;이재형;우주완;이두일;이상현;서지현;문난경
    • 대기
    • /
    • 제30권3호
    • /
    • pp.257-276
    • /
    • 2020
  • Faithful evaluation of the meteorological input is a prerequisite for a better understanding of air quality model performance. Despite the importance, the preliminary meteorological assessment has rarely been concerned. In this study, we aim to evaluate the performance of the Weather Research and Forecasting (WRF) model conducting a year-long high-resolution meteorological simulation in 2016 over the Seoul metropolitan area. The WRF model was configured based on a series of sensitivity simulations of initial/boundary meteorological conditions, land use mapping data, reanalysis grid nudging method, domain nesting method, and urban canopy model. The simulated results of winds, air temperature, and specific humidity in the atmospheric boundary layer (ABL) were evaluated following statistical evaluation guidance using the surface and upper meteorological measurements. The statistical evaluation results are presented. The model performance was interpreted acceptable for air quality modeling within the statistical criteria of complex conditions, showing consistent overestimation in wind speeds. Further statistical analysis showed that the meteorological model biases were highly systematic with systematic bias fractions (fSB) of 20~50%. This study suggests that both the momentum exchange process of the surface layer and the ABL entrainment process should be investigated for further improvement of the model performance.

해양 생물 펌프가 대기 중 이산화탄소에 미치는 영향 그리고 기후 변동과의 연관성 (The Impact of the Oceanic Biological Pump on Atmospheric CO2 and Its Link to Climate Change)

  • 권은영;조양기
    • 한국해양학회지:바다
    • /
    • 제18권4호
    • /
    • pp.266-276
    • /
    • 2013
  • 바다-육지-대기로 이루어진 기후 시스템에서 가장 큰 탄소의 저장고는 바다이다. 바다가 대기로부터 탄소를 흡수하는 주요 수단은 생물 활동에 의한 것으로서, 광합성에 의해 유기 물질로 동화된 탄소가 해저로 침강하고 분해되는 과정에서 깊은 바다물은 탄소를 축적하게 된다. 이러한 탄소 수송 작용을 생물 펌프라 부르며, 해수면 탄소 농도를 낮춤으로써 대기 중 이산화탄소 분압을 낮은 상태로 유지해주는 중요한 기작이다. 생물 펌프에 의해 해저에 축적된 탄소는 해양 순환에 의해 해수면에 돌아오고, 해양-대기 기체 교환에 의해 대기로 배출된다. 바다가 대기와 소통하는 이산화탄소의 양은 과거 빙하기-간빙기 기후 변동과 관련하여 과거 수십만년동안 대기 중 이산화탄소 분압변화에 주도적인 역할을 하여 온 것으로 알려져 있다. 본 논문에서는 바다에서 일어나는 탄소 순환을 간단하게 소개하고, 해양 순환의 변화가 어떻게 탄소 순환을 변형시키고, 대기 중 이산화탄소에 영향을 미치는지를 기후 변동의 관점에서 살펴보고자 한다.

집중적 답압 피해에서의 잔디 회복을 위한 강제 흡.호기 순환식 설비의 효과 (Effects of a Forced Air-Flow System for Recovery of Turfgrass after Intensive Traffic Injury)

  • 이정호;손진수;김인철;주영규
    • 아시안잔디학회지
    • /
    • 제21권2호
    • /
    • pp.127-135
    • /
    • 2007
  • Korea and Japan hosted the FIFA World Cup Soccer Game in 2002. Ten stadiums had been built and more than 30 soccer grounds for practice were renovated in Korea. Sport fields in both countries had problems on cool-season turfgrass growth and quality by summer decline during humid and warm climate especially followed by intensive uses. We measured the effects of air-flow system, which is designed to optimize rootzone soil gas and moisture levels to promote the growth and maintenance turfgrass. This experiment was carried out to verify the effects of the system on soil gas exchange, ground resilience, and turfgrass recovery in turfgrass rootzone. Within 1 or 2hr of operation of the system, rootzone soil gas ($CO_2$, $O_2$) levels returned to natural atmospheric levels completely Soil $CO_2$ levels began to decrease within the first 10 min of operation of the system. The levels were reduced from 1.3 to 0.06% after 30 min, and natural atmospheric levels within 1 hr. When the system was turned off, $CO_2$ levels increased to 0.36% and 0.7% after 5 and 20 hr, respectively. The application of the system did not affect the resilience of turf surface after traffic treatments. Higher traffic treatment resulted in higher surface resilience especially in zoysiagrass plots. Operation of the system had a significant beneficial impact on turf recovery by increased root dry wight and improved turf quality, as compared with the non-operated check plots.

러닝웨어 재킷의 슬릿 위치가 통기성과 착용감에 미치는 영향 (Ventilation and Comfort Sensation by Slit Positions of Running Wear Jackets)

  • 임지혜;노의경;유화숙;김은애
    • 한국의류학회지
    • /
    • 제33권11호
    • /
    • pp.1794-1805
    • /
    • 2009
  • This study investigates the influence of slit positions on the microclimate temperature/humidity of garments. To design the slits, a market survey was performed to indicate the method to apply the slits, in addition to a literature survey about muscles and body surface variation through body movements. Based on the survey, three positions of slits were selected, shoulder slit, lowback slit, and midback slit, a slit width of 1cm and length to 30cm was used. The results showed that microclimate temperatures/humidity on the back according to the slit positions were in the order of, lowback, midback, and the shoulder. The lowback slit showed the highest effect on the temperature/humidity of a front trunk. Lowback slits affected on localized areas of the glutaeus maximus, erector spinae, and latissimus dorsi. Midback slits affected the back muscle and deltoid. Shoulder slits showed a more significant effect on the localized area of the deltoid versus other localized areas. In the subjective sensations, the lowback slit was cooler, dryer, and more comfortable than the other slits. For the subjective sensations by fabric characteristics, the slit positions correlated at |r|${\geq}.8$ and were significant at p<.001 The results show that the lowback slit has a superior air exchange effect and thermoregulation qualities.

신규 잔류성 유기오염물질(Emerging Persistent Organic Pollutants E-POPs) 핵사클로로시클로핵산(HCH)의 대기-토양-물-저질에서의 잔류특성 (Characteristics of Persistent of Hexachlorocyclohexane(HCH) in Ambient Air-Soil-Water-Sediment for a Emerging Persistent Organic Pollutants(POPs))

  • 황성민;이석형;박노진;옥곤
    • 한국환경과학회지
    • /
    • 제19권12호
    • /
    • pp.1343-1354
    • /
    • 2010
  • The purpose of the study was to analyze the persistence of HCH in atmosphere, soil, sediment and water of the western and southern regions of Korea. The samples from the western region were collected from Anmyeon Island, and the samples from the southern region were collected from Kimhae and Busan. The concentration of HCH isomers in atmosphere showed the pattern of $\alpha$-HCH>$\gamma$-HCH>$\beta$-HCH. The regions with high HCH concentration in the atmosphere are the regions that have been highly exposed to HCH used in the past, and the areas that have been influenced by the long range transport. The HCH that persists in the soil, water and sediment evaporates into the atmosphere, showing the characteristics of Air-Surface exchange. When the regional concentration distributions are compared, the concentration of HCH was higher in the atmosphere of a plain and the cities near the plain, than the urban areas. In this study, the ratio of $\alpha/\beta$-HCH was used as an indicator for estimating the source of Technical HCH and Lindane. According to the result, the contribution of Lindane was high in Kimhae plain and Kimhae urban areas. However, in Busan, the contribution of Technical HCH was higher than Lindane. In case of Anmyeon Island, the western region of Korea had high contribution from Tehcnical HCH. In soil and sediment, $\beta$-HCH was dominant. In water, $\gamma$-HCH was dominant among other isomers. Such results are due to $\gamma$-HCH inLindane. Furthermore, the source of $\gamma$-HCH in urban areas is assumed to be the use of medicine, medical supplies and other living supplies. Based on the results of this study, the management of HCH, a newly list up emerging POPs, should be strengthened by further research on sources, fate, persistency, accumulation and exposures and etc. to the risk assessments.