• Title/Summary/Keyword: Air ventilation

Search Result 1,570, Processing Time 0.025 seconds

IAQ Field Survey in an Apartment Housing Equiped for Heat Recovery Ventilation System with Air Cleaning Function (아파트 실내공기질 현장측정에 의한 전열교환 청정환기유니트 성능평가)

  • Yee Jurng Jae;Lee Joong Hoon;Lee Seung Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.688-693
    • /
    • 2005
  • Nowaday the natural ventilation rate decreases because the apartment housing is being air-tight. Therefore, Indoor Air Quality (IAQ) and indoor environment grow worse. Especially, Formaldehyde (HCHO), Volatile Organic Compounds (VOCs) which is emitted from the building materials and coating material etc. occur Sick House Syndrome that cause negative impact on resident's respiratory system and body. Therefore in construction field, it will be a important issues that development of a ventilation system with high effectiveness which can exhaust the contaminant out of the building quickly. In this research we evaluated 'wall attachable duct-less Heat Recovery Ventilation (HRV) system with air cleaning function'. We executed a synthetic evaluation about indoor air environment under various operating condition installing the system in real scale apartment house that is built in Anyang city. HRV system with air cleaning function showed good performance by removing HCHO, VOCs with less ventilation energy.

Numerical Analysis of Moisture Ventilation in the Dry Room (Dry room내 수분환기에 대한 수치적 연구)

  • 이관수;임광옥;정영식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.908-916
    • /
    • 2000
  • In this paper, the characteristics of moisture ventilation in the lithium ion battery manufacturing dry room are studied numerically using standard $k-\varepsilon$ turbulence model. Both the steady-state and the unsteady behaviors of moisture ventilation are analyzed by considering local and uniform moisture generation. In order to evaluate the characteristics of moisture ventilation, three scales of ventilation efficiency and characteristic ventilation time are presented from the numerical results. It was shown that moisture distribution was dependent strongly on the flow field. The characteristics of moisture ventilation were improved by 20% and 40% in terms of the 1st scale of ventilation efficiency (SVE1) and the 2nd scale of ventilation efficiency (SVE2), respectively, through the modifications of design variables such as the addition of inlets, outlets and partition. A significant improvement in the characteristic ventilation time and the moisture exhaust efficiency was also made by these modifications.

  • PDF

A Study on Ventilation Effectiveness Characteristics in a Apartment Housing (공동주택에서 환기효율 특성에 관한 수치적 연구)

  • Cha, Kwang-Suk;Lee, Dae-Woo;Yeom, Dong-Suk;Park, Myung-Sig
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.39-44
    • /
    • 2005
  • Recently according to the fashion of well-being, it is increasing that heat recovery ventilator is applied to the apartment housing, But the uniform locations of inlet and outlet in each room may provide better indoor air quality than ununiform locations of inlet and outlet. Proper design of air supply system requires information concerning the gas concentration difference between the ventilation effectiveness at the breathing line. This paper presents models to predict the gas concentration difference and the ventilation effectiveness, based on the two cases with proper number of outlets. As one of the results it is desirable to set the outlet location near the furniture which produce the contamination gas so much.

  • PDF

A Study on the Air Flow Characteristics in an Apartment Complex and Ventilation Performance of an Individual Unit for Improving IAQ (주동형태 변화에 따른 아파트 단지내 기류분석 및 단위주호의 환기성능에 관한 연구)

  • Lee, Jung-Hyun;Lee, Seung-Hee;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.11-16
    • /
    • 2005
  • The recent trends of high-density and high-rise in apartment housing have caused the problems of decrease in ventilation rates and increase of indoor pollutant contaminants. SHS(Sick House Syndrome) has now become a major issue and threats the health of residents. To solve these indoor air problems, increase in ventilation rate is considered as one of the most efficient approach. Thus, the recent housing development is pursuing improvement in the site design and the layout of apartment building blocks to promote natural ventilation is now investigated as one of the fundamental solutions. This study was focused on the air flow characteristics of outdoor environment in an apartment complex to keep the pollutants out of the site. Age of air and pressure difference have been used as indices of the outdoor air quality. Four different types of apartment building layouts have been analyzed by CFD simulation. This study again selected a real apartment housing complex as a case study model. By analyzing the pressure differences between the front and rear of an apartment building block, the ventilation performance in each individual unit was evaluated, and its impact on ventilation performance is investigated by analyzing the stagnant air around the apartment building blocks. During this process, existing patterns of apartment housing layout have been evaluated, and the most appropriate site layout has been chosen to analyze the outdoor airflow patterns. Based on the analysis of airflow patterns of site layout, the possibilities of improving ventilation performance of an individual apartment housing is proposed.

Performance Simulation of a Ventilation System Adopting a Regenerative Evaporative Cooler (재생증발식 냉방기를 이용한 환기 냉방시스템의 성능해석)

  • Chang, Y.S.;Lee, D.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.8-15
    • /
    • 2011
  • Cooling load reduction was analysed of a ventilation system adopting a regenerative evaporative cooler. The regenerative evaporative cooler is a kind of indirect evaporative cooler which cools the air down to its inlet dewpoint temperature in principle without change in the humidity ratio. The regenerative evaporative cooler was found able to cool the ventilation air to $18{\sim}21^{\circ}C$ when the outdoor condition ranges $25{\sim}35^{\circ}C$ and 0.01~0.02 kg/kg. When the outdoor humidity ratio is lower than 0.018 kg/kg, the regenerative evaporative cooler was found to provide cooling performance enough to compensate the ventilation load completely and to supply additional cooling as well. Energy simulation during the summer was carried out for a typical office building with the ventilation system using the regenerative evaporative cooler. The results showed that the seasonal cooling load can be reduced by about 40% by applying the regenerative evaporative cooler as a ventilation conditioner. The reduction was found to increase as the outdoor temperature increases and the outdoor humidity ratio decreases.

Experiments on the Effective Engine Room Ventilation in a Power Car (동력 철도차량 기관실의 효과적인 환기에 관한 실험적 연구)

  • Han, S.Y.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.166-176
    • /
    • 1990
  • Experimental study was made to find the effective ways for cooling of engine room in a power car through natural ventilation, forced ventilation and wind tunnel test of 1:10 model. Through the measurements of inner temperature of engine room and pressure distribution of model surface for the various opening combinations and the fan locations, the following results are obtained. For natural ventilation, side and top opening combination is more effective than the side openings only and optimal opening combination is all side openings with top center opening. For forced ventilation with fan on the roof, the combination of all sides and top opening is more effective than the combination of side and top opening, and the optimal location of fan is top center. When the model is located in the air stream, the combination of side and top opening is more effective than the side openings only, and the optimal location of top opening is the front opening. With both air stream and forced ventilation, the optimal location of fan is the side region, and the direction of side grill installation is found to have negligible effect on the room ventilation.

  • PDF

A Study on the Mechanical Ventilation System of Bathroom in Apartment House (공동주택 화장실의 기계 환기시스템에 관한 연구)

  • 함진식
    • Journal of the Korean housing association
    • /
    • v.12 no.3
    • /
    • pp.141-148
    • /
    • 2001
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$\textrm{m}^2$, were made and installed in a laboratory. These ventilation mock-ups were available for control of air supply and exhaust, and the sizes of supply openings were 40cm${\times}$1cm, 40cm${\times}$3cm, and 40cm${\times}$5cm. They were installed at five positions, spaced 45cm at a height of 5cm from the floor. The exhaust fan was designed for its operating voltage to be set to five steps(100V, 130V, 150V, 180V and 220V) in order to control its air flow rates. When the size and position of each supply opening were changed with the wind velocity of the exhaust fan set to the step 5, the ventilation rates were measured and analyzed by the concentration decay method of tracer gas method, in order to present an efficient mechanical ventilation system. The results of the study revealed that the ventilations rates would increase in the presence of supply openings, compared to the absence of supply openings, and that the larger the size of the supply opening, the more the ventilation rates. Therefore, it was found necessary to take air supply into consideration.

  • PDF

An Experimental Study on Ventilation and Thermal Performance of Passive Ventilation Building Envelopes (패시브환기외피의 통기 및 열성능에 관한 실험적 연구)

  • Yoon, Seong-Hwan;Lee, Tae-Cheol;Kang, Jung-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.711-717
    • /
    • 2011
  • In this study, 5 types of PVS(Passive ventilation system) units are made and experimented its ventilation performance, thermal performance according to open rate and hole diameter of perforated aluminum plane. Results are as follows. 1) The ventilation performance increases approximately 50~70% according by the open rate of PVS increasing. Also, the ventilation performance increases about 2%~12% according by the hole diameter of PVS increasing. 2) In winter temperature/pressure condition(in : $20^{\circ}C$, out : $-2^{\circ}C/{\Delta}P$ : 0.2~5.0Pa) the temperature of inflow air decreases according by the open rate of PVS increasing. Heat gain performance decreases 10.1%, 25.6% when open rate increases 3) In the same condition, Heat gain performance decreases 18.3%, 18.8% according by the hole diameter of PVS increasing.

A Study of Solar heat removal Impact with Air-Vent Wall (통기벽체적용 건물에서의 일사열 제거효과 검토)

  • Kim, Sang-Jin;Kum, Jong-Soo;Choi, Kwang-Hwan;Shin, Byong-Hwan;Chung, Yong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.25-31
    • /
    • 2004
  • Ventilation through air vent system in a building envelope is expected to be an effective measure to release solar radiation. An external surface of a wall absorbs solar radiation and transfers it to the air in the cavity. The warmed air gets buoyant force. So when openings are provided at the top and bottom of the cavity, the warmed air is released through the top opening and cooler outside air replaces the space in the cavity. This reduces the further heat transmission into the built environment. This natural ventilation effect seems to be steady and strong. So because of the cavity and the openings, the cooling load reduction by natural ventilation is believed to be considerable.

Estimation of Ventilation Volume by Traffic Ventilation Force in Tunnel (교통환기력에 의한 터널내 환기량 추정에 관한 연구)

  • 김종호;이상칠;도연지;김신도
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.273-278
    • /
    • 1995
  • This study is to estimate the ventilation volume by the traffic that originated from driving automobiles for two tunnels (Kugi tunnel and Kumhwa tunnel) that adopted natural ventilation system among tunnels of Seoul, and on the basis of which, we estimated the ventilation velume at various conditions. With the result of the estimation, we will present the basic method that can be operated with the optimum condition for the ventilation system. Estimating the predicted ventilation volume in the tennel by the pollutant concentration, we used traffic volume and CO emission data by the automobile speed and CO concentration in the tunnel. And, when we estimated the traffic ventilation volume by natural and traffic ventilation force, we used traffic volume, automobile speed, tunnel area, automobile area data and so on. As the result of simple regression between predicted ventilation volume and traffic ventilation volume, we attained the regression coefficient 0.88, and achieved the relation form that predicted ventilation volume equal 0.12x traffic ventilation volume-92, 000. Using this equation, we estimated the ventilation volume to satisfy the enviromnental standards of several space, and calculated the required volume for mechanical ventilation. Incase of Kumhwa Tunnel, there is a need of mechanical ventilation all day long to satisfy air quality standard 9 ppm for 8 hours average and 10 ppm for the indoor air quality standard of public facilities.

  • PDF