• 제목/요약/키워드: Air vent wall

검색결과 13건 처리시간 0.026초

일사열 배제를 위한 통기벽체 적정 길이에 대한 검토 (A Study on the optimal length of air cavity for Solar heat removal with Air-Vent System)

  • 김상진;금종수;최광환;신병환;정용현
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.33-38
    • /
    • 2004
  • Outside wall systems we lost much energy from the dew of thermal bridge and unsuitable adiabatic construction. The air vent wall system can make reduce cooling loads from the outside wall in summer. The basic concept is connected with buoyant force by the difference of density. An external surface of a wall absorbs solar radiation, and transfers it to the air in the cavity. The warmed air gets buoyant force. So the warmed air is released through the top opening and cooler outside air replaces the space in the cavity. So because of the cavity and the openings, the cooling load reduction by natural ventilation is believed to be considerable. The purpose of this study is finding optimal length of air cavity by numerical analyses.

통기벽체적용 건물에서의 일사열 제거효과 검토 (A Study of Solar heat removal Impact with Air-Vent Wall)

  • 김상진;금종수;최광환;신병환;정용현
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.25-31
    • /
    • 2004
  • Ventilation through air vent system in a building envelope is expected to be an effective measure to release solar radiation. An external surface of a wall absorbs solar radiation and transfers it to the air in the cavity. The warmed air gets buoyant force. So when openings are provided at the top and bottom of the cavity, the warmed air is released through the top opening and cooler outside air replaces the space in the cavity. This reduces the further heat transmission into the built environment. This natural ventilation effect seems to be steady and strong. So because of the cavity and the openings, the cooling load reduction by natural ventilation is believed to be considerable.

급기구 형상에 따른 겨울철 실내 온열환경의 비교 (Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations)

  • 한화택;정영균
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

초음속 유동장 내 벤트 혼합기에 관한 수치해석 연구 (A Computational Study of Flowfield for a Vent Mixer in Supersonic Flow)

  • 김채형;정인석
    • 한국추진공학회지
    • /
    • 제12권2호
    • /
    • pp.33-39
    • /
    • 2008
  • 초음속 연소에서 혼합 효율을 높이면서 전압력 손실을 줄일 수 있는 혼합기에 관한 연구가 수십 년동안 진행되어 왔으며, 본 논문에서는 이를 만족할 수 있는 새로운 개념의 혼합기를 고안하여 그 성능을 수치해석을 통하여 분석하였다. 후면 계단 혼합기를 비교 대상으로 압력과 등밀도선, 유선구조를 분석하였다. 공동이나 탭에서 발생하는 충격파가 후류로 전파되는 것과 달리, 벤트 혼합기의 구멍에서 발생하는 충격파는 벤트 혼합기 끝단에서 형성되는 팽창파에 의해 전파되지 못하며, 후류부의 재순환 영역으로 인해 경계층이 증가하며 이로 인해 후면 계단 방식에 비해 약한 충격파가 형성된다. 따라서 충격파로 인한 전압력 손실을 줄일 수 있으며, 구멍을 통한 공기 유입은 다수의 재순환 영역을 형성하여 혼합 효율을 증대시킨다. 또한 후류부에서 유동 흐름이 전반적으로 안정화되는 것을 볼 수 있다.

Outpatient Drainage Therapy with a Thoracic Vent for Traumatic Pneumothorax due to Bull Attack

  • Sano, Atsushi;Tsuchiya, Takehiro;Nagano, Masaaki
    • Journal of Chest Surgery
    • /
    • 제47권6호
    • /
    • pp.563-565
    • /
    • 2014
  • Outpatient drainage therapy is generally indicated for spontaneous pneumothoraces. A 63-year-old man, who had been attacked by a bull sustaining injuries on the right side of his chest, was referred to the emergency room with dyspnea. His chest X-ray showed a small pneumothorax. The next day, a chest X-ray demonstrated that his pneumothorax had worsened, although no hemothorax was identified. Outpatient drainage therapy with a thoracic vent was initiated. The air leak stopped on the third day and the thoracic vent was removed on the sixth day. Thoracic vents can be a useful modality for treating traumatic pneumothorax without hemothorax.

초음속 유동 내 벤트 혼합기의 형상적 특성에 따른 성능 연구 (A Performance Study of Vent Mixer with Geometric Characteristics in Supersonic Flow)

  • 김채형;정인석
    • 한국항공우주학회지
    • /
    • 제37권1호
    • /
    • pp.69-75
    • /
    • 2009
  • 본 논문은 새로운 개념의 초음속 혼합기인 벤트 혼합기의 형상적 특성에 따른 공력 특성을 연구하였다. 홀의 크기는 2 mm이며 혼합기 벽면에서 2 mm 떨어진 곳에 위치한 모델(case 1)과 혼합기 벽면 뒤쪽에 위치한 모델(case 2)의 경우 같은 전압력 회복율을 보였으며, 홀의 크기를 반으로 줄인 1 mm(case 3) 모델은 cases 1, 2에 비해 낮은 전압력 회복율을 보였다. 재순환 영역의 크기는 cases 1-3은 같지만 전단층 두께는 cases 1, 2가 case 3 보다 두꺼웠다. 재순환 영역 내 압력 손실의 경우 cases 1, 2은 case 3에 비해 낮은 압력 손실과 높은 속도 구배를 보였으며, 이는 재순환 영역 내 공기와 연료의 혼합을 증대시키는 요인이다. 재순환 영역 내로 유입 되는 유동에 의해 형성되는 박리 버블은 연소기의 전압력 회복율과 재순환 영역 내 압력 분포와 순환 유동에 영향을 미친다. 따라서 박리 버블 형성에 영향을 주는 유입 공기 유량이 벤트 혼합기 성능에 주요한 영향을 미치는 것을 알 수 있다.

바닥의 위치가 Vortex Vent의 배기성능에 미치는 영향 (Effect of the Floor on the Ventilation Performance of the Vortex Vent)

  • 이진원;임영복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.154-158
    • /
    • 2009
  • The vortex ventilation system (VV) which uses a rotating finned swirler installed coaxially with the exhaust duct is a very effective local ventilator. VV can enhance the capture depth by a factor of 3-5 compared to the conventional exhaust hood, in the absence of any solid walls nearby. In real situations there may exist ceiling, side wall and floor, all of which can affect the flow field and suction performance by way of the no-slip condition on the walls. 3D CFD simulation was performed in order to see the effect of the floor on the capture performance of the VV. The presence of floor reduced suction flow velocity, and increased the critical rotational speed which is the rotational speed required for stable vortex formation. Flow velocity profile along the axis could be well approximated by a universal functional form when the distance from the exhaust inlet is non-dimensionalized by the distance to the floor. Capture depth, define by the distance from the exhaust inlet to a point of velocity decreased to 10% of that at the inlet, is reduced by about 10% when the floor distance is 6 times the exhaust hood diameter.

  • PDF

관상동맥우회수술후 합병증과 사망율에 대한 임상적 고찰;61례 보고 (Complications amd Mortality After Coronary Artery Bypass Graft Surgery; Collective Review of 61 Cases)

  • 조건현
    • Journal of Chest Surgery
    • /
    • 제26권7호
    • /
    • pp.526-531
    • /
    • 1993
  • Sixty-one consecutive patients with coronary artery bypass graft for myocardial revascularization were retrospectively reviewed to analyze various pattern of postoperative complication and death during hospital stay from Nov. 1988 to Oct. 1992. Fortytwo of the patients were male and nineteen female. The mean age was 56 and 51 years in male and female. Preoperative diagnosises were unstable angina in 14 of patients, stable angina in 28, postmyocardial infarction state in 15, and state of failed percutaneous transluminal coronary angioplasty in 4. 141 stenosed coronary arteries were bypassed with use of 20 pedicled internal mammary artery and 124 reversed saphenous vein grafts. Postoperative complications and perioperative death were as follows: 1. Of 61 patients undergoing operation, peri and postoperative over all complication occured in 15 patients [ 25% ]; newly developed myocardial infarction in 4, intractable cardiac arrhythmia including atrial fibrillation and frequent ventricular premature contraction in 3, bleeding from gastrointestinal tract in 2, persistent vegetative state as a sequele of brain hypoxia in 1, wound necrosis in 1, left hemidiaphragmatic palsy in 3 and poor blood flow through graft in 2. 2. Operative mortality was 8%[5 patients]. 3 out of these died in operating room; 1 patient by bleeding from rupture of calcified aortic wall, 1 by air embolism through left atrial vent catheter, 1 by low cardiac output syndrome. 2 patients died during hospital stay; 1 by acute respiratory distress syndrome with multiuple organ failure, 1 by brain death after delayed diagnosis of pericardial tamponade.

  • PDF

압전세라믹 냉각홴에 의한 강제 공랭 모듈 주위의 열전달특성 (Heat Transfer Characteristics Around a Surface-Mounted Module Cooled by Piezoelectric Fan)

  • 박상희;박규진;최성대
    • 대한기계학회논문집B
    • /
    • 제28권7호
    • /
    • pp.780-788
    • /
    • 2004
  • This paper reports the fluid flow and heat transfer around a module cooled by forced air flow generated by a piezoelectric(PZT) cooling fan. The fluids are locally accelerated by a flexible PZT fan which deflects inside a fluid transport system of comparatively simple structure mounted on a PCB in a parallel-plate channel(450${\times}$80${\times}$700㎣). Input voltages of 20-100V and a resonance frequency of 23㎐ were used to vibrate the cooling fan. Input power to the module was 4W. The fluid flow around the module was visualized by using PIV system. The temperature distributions around a heated module were visualized by using liquid crystal film(LCF). The cooling effect using a PZT fan was independent of the vent area ratios at the channel inlet and was similar to the forced convection cooling. We found that the flow type was Y-shape and the cooling effect was increased by the wake generated by a piezoelectric cooling fan.

전남 지방에 있어서의 양송이 재배에 최적한 환경조건 조절법 분석에 관한 연구 (Study on the Controlling Mechaniques of the Environmental Factors in the Mushroom Growing House in Chonnam Province)

  • 정병재;이은철
    • Journal of the Korean Wood Science and Technology
    • /
    • 제2권2호
    • /
    • pp.32-34
    • /
    • 1974
  • 본 논문은 1968년 과학기술처 Trust Fund에 의하여 실시된 연구로서 전남 지방에 있어서 최적합한 양송이 재배사를 구명하기 위하여 이미 구미에서 연구된 결과를 토대로 하여 우리나라의 기후적 조건과 경제적 조건을 고찰한 자연공기 순환법을 적용, 양송이 재배에 최적한 환경 조건과 이의 조절법을 구명코저 시상식재배사와 지하실에 구축한 태양열을 이용하는 태양열식 재배사를 본실험용으로 구축하고 전자에 대하여서는 외가의 온도의 영향을 받지 아니하는 측벽구조와 천정의 구조, 환기구의 위치 및 그 환기량등에 관하여 검토하였으며 후자에 관하여는 태양열 이용 효과에 대하여 검토하였다. 또한 동기에 있어서의 계속적 재배를 가능케 하기 위하여 양송이 재배사의 보온에 적합한 가열 장치에 대하여서도 검토하였다. 1. 실험용 지상식 양송이 재배사의 효과에 관하여는 이미 실험결과 및 그 분석에서 지적된 바 있거니와 그 측벽 및 천정의 구조는 재배사를 외계의 기상조건에서 격리하는데 충부한 효과가 있는 것으로 고려된다. 2. 반지하실에 구축한 실험용 태양식 양송이 재배사의 효과에 관하여는 실험결과 및 그 분석에 지적한 바와 같거니와 태양열을 이용하는데 있어 충분한 효과가 있는 것으로 고려된다. 그러나 이것을 농가에 적용하기 위하여는 다음과 같은 제점이 개선되어야 할 것으로 고려된다. 즉 (1) 태양식의 지붕과 천정은 실험용 지상식재배사의 그것과 동일히 하고, (2) 태양열 수열 장치는 적당히 제고되어야 할 것으로 고려된다. 3. 본 실험 연구에서 실시한 각조의 환기법중 GE-CV 및 VS-CV 환기법이 가장 효과적인 것으로 본다. 4. 측벽수치 및 지중 환기장치는 이미 지적한 바와 같이 농가용 양송이재배사의 자연환기법으로 실용적 가치가 충분하다. 그것은 이들 환기장치는 그 환기로를 통하여 사내에 유입되는 외기의 온도를 인공적으로 가열이나 또는 냉각하지 않고 사내 온도에 접근하지 않도록 조절하는 효과가 있기 때문이다. 지금 외온을 $X^{\circ}C$로 할때 각종 환기로에 의하여 흡수되는 온도 $Y^{\circ}C$를 X의 함수로 하는 실험식은 다음과 같이 회귀직선으로 표시된다. GP$\cdots$Y=0.9X-12.8 GE$\cdots$Y=0.96X-15.11 VS$\cdots$Y=0.94X-17.57 5. 재배사내에 유입되는 공기 및 사외로 배출되는 공기에 관한 실험식은 다음과 같이 회귀직선 및 지수곡선으로 표시된다. 5.1 배출속도 Ycm/sec.를 유입속도 Xcm/sec.의 함수로 하는 회귀직선식 GE-CV(50%)법$\cdots$Y=1.0X-1.65 GE-CV(100%)법$\cdots$Y=0.42X+2.03 VS-CV(100%)법$\cdots$Y=0.85X+0.96 5.2 배출량 $Ym^3$/hr.를 유출량${\times}m^3$/hr.의 함수로 하는 회귀직선식 GE-CV(50%)법$\cdots$Y=2.59X-10.88 GE-CV(100%)법$\cdots$Y=2.16X+26.53 5.3 상면 공기이동 속도 Ym/sec.를 배출공기 속도${\times}m$/sec.의 함수로 하는 회귀직선식 GE-CV(50%)법$\cdots$Y=0.5X+0.84 5.4 $CO_2$ 축적량 Y(%)를 상면공기이동속도 cm/sec.의 함수로 하는 회귀직선식 GE-CV(50%)$\cdots$Y=114.53-6.42X 5.5 $CO_2$ 축적량Y(%)를 배출공기량 $m^3$/hr.의 함수로 하는 지수곡선식 GE-CV(50%)$\cdots$Y=$127.18{\times}1.0093^{-x}$ 5.6 Natural ventilation system에 있어서 양송이 생육에 적합한 환경적조건을 마련하기 위한 환기구의 단면적은 재배사 전용적에 대하여 다음과 같은 비율로할 수 있다. GE(지중유입 환기구 단면적)$\cdots$0.3-0.5%(요조절) CV(천정배출 환기구 단면적)$\cdots$0.8-1.0% (요조절) 6. 본 연구에서 실험한 각종의 가열장치중 무압증기수 보이라도 사요할 수 있는 온수 보이라가 농가용 양송이재배사 가열장치로서, 그 효과면에 있어서나 또는 그 가격면에 있어서 최적합다하는 것이 확인되고 있다.

  • PDF