• Title/Summary/Keyword: Air tubes

Search Result 495, Processing Time 0.024 seconds

Commissioning result of the KSTAR in-vessel cryo-pump

  • Chang, Y.B.;Lee, H.J.;Park, Y.M.;Lee, Y.J.;Kwag, S.W.;Song, N.H.;Park, D.S.;Joo, J.J.;Moon, K.M.;Kim, N.W.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to $LN_2$ one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

The Effects of Hot Corrosion on the Creep Rupture Properties of Boiler Tube Material (보일러 管材料의 크리프破斷特性에 미치는 고온부식의 影響)

  • 오세욱;박인석;강상훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.2
    • /
    • pp.236-242
    • /
    • 1989
  • In order to investigate the effects of hot corrosion on the creep rupture properties and creep life of 304 stainless steel being used as tube materials of heavy oil fired boiler, the creep rupture tests were carried out at temperature 630.deg.C, 690.deg.C and 750.deg.C in static air for the specimens with or without coating of double layer corrosives according to the new hot corrosion test method simulating the situation commonly observed on superheater tubes of the actual boiler. The double layer corrosives are 85% V$_{2}$O$_{5}$ + 10% Na$_{2}$So$_{4}$ + 5% Fe$_{2}$O$_{3}$ as the inner layer corrosive being once melted at 900.deg. C and crushed to powder, and 10% V$_{2}$O$_{5}$ + 85% Na$_{2}$SO$_{4}$ +5% Fe$_{2}$O$_{3}$ as the outer layer corrosive. As results, in the specimen coated with the double layer corrosives, the rupture strength was extremely lowered and showed a large difference each other. The rupture ductility also lowered remarkably as a result of the brittle fracture mode due to hot corrosion. These results indicate that hot corrosion could essentially alter the creep fracture mechanism. From the metallographic observation, it was clarified that the rupture life of 304 stainless steel subjected to hot corrosion was chiefly determined by the behavior of the aggressive intergranular penetration of sulfides.des.

Effects of Interrupted Wetness Periods on Conidial Germination, Germ Tube Elongation and Infection Periods of Botryosphaeria dothidea Causing Apple White Rot

  • Kim, Ki Woo;Kim, Kyu Rang;Park, Eun Woo
    • The Plant Pathology Journal
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • Responses of Botryosphaeria dothidea to interrupted wetness periods were investigated under in vivo and in vitro conditions. Conidia of B. dothidea were allowed to germinate on apple fruits under wetting condition at $25^{\circ}C$ for 5 hr. They were air-dried for 0, 1, 2 or 4 hr, and then rewetted at $25^{\circ}C$ for 5 hr. Following an initial wetness period of 5 hr, 83% of the conidia germinated. The percent conidial germination increased to 96% when wetting was extended continuously another 5 hr. However, no further conidial germination was observed when wetting was interrupted by dry periods of 1, 2 and 4 hr, resulting in 83, 81 and 82%, respectively. The mean length of the germ tubes was $37{\mu}m$ after 5 hr of wetting and elongated to $157{\mu}m$ after 10 hr of continuous wetting. On the other hand, interruption of wetting by a dry period of 1 hr or longer after the 5 hr of initial wetting arrested the germ tube elongation at approximately $42{\mu}m$ long. Prolonged rewetting up to 40 hr did not restore germ tube elongation on slide glasses under substrate treatments. Model simulation using weather data sets revealed that ending infection periods by a dry period of at least 1 hr decreased the daily infection periods, avoiding the overestimation of infection warning. This information can be incorporated into infection models for scheduling fungicide sprays to control apple white rot with fewer fungicide applications.

Development and Application of Conducting Shape Memory Polyurethane Actuators (전도성 형상기억폴리우레탄 작동기의 개발 및 응용)

  • Baek, Il-Hyeon;Gu, Nam-Seo;Jeong, Yong-Chae;Jo, Jae-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.1
    • /
    • pp.56-64
    • /
    • 2006
  • This paper presents the development and application of a conducting shape memory polyurethane (CSMPU) actuator. While conventional shape memory polyurethanes were activated by external heat source, conducting shape memory polyurethanes introduced in 2004 are activated by electric power. Conducting shape memory polyurethane actuators were manufactured by adding carbon nano tube to conventional shape memory polyurethane. The main problem of the CSMPU developed in 2004 was bad dispersion of carbon nano tubes. In this paper, we tried to find how to solve the dispersion problem, and with a lot of elaborative works, conducting shape memory polyurethane actuators which had better electrical characteristics were developed. Then the actuation performance of the conducting shape memory polyurethane actuators was also measured and assessed. Finally, the possibility of applications were examined through the installation to Micro Air Vehicle.

Change in concentration and bioactivity of soil-applied pretilachlor under various soil moisture conditions (다양한 토양수분조건에 처리한 pretilachlor의 농도 및 활성 변화)

  • Lee, Do-Jin
    • The Korean Journal of Pesticide Science
    • /
    • v.3 no.2
    • /
    • pp.81-85
    • /
    • 1999
  • Concentration change of soil-applied pretilachlor (2-chloro-2',6'-diethyl- N-2-propoxyethyl)-actanilide) was investigated under upland condition with various soil moisture contents ranging from 50 to 80%(water content by weight). Following pretilachlor from each soil solution was extracted by centrifugation using double tubes, its concentration was determined by HPLC. Pretilachlor concentration in the soil solutions were almost the same under various soil moisture conditions. However, the total amount of pretilachlor increased as the soil moisture content increased. With increasing soil moisture content, the bioactivity of soil-applied pretilachlor on inhibiting the growth of Echinochloa ultilis Ohwi et Yabuno and the absorption of $^{14}C$-pretilachlor in its plants were also enhanced. Our results demonstrate that the absorption of pretilachlor in plants varies with soil moisture content and thus the bioactivity of soil-applied pretilachlor on inhibiting plant growth is different under various soil moisture conditions at the same dosage based on air-dried weight.

  • PDF

Development of Respiration Sensors Using Plastic Optical Fiber for Respiratory Monitoring Inside MRI System

  • Yoo, Wook-Jae;Jang, Kyoung-Won;Seo, Jeong-Ki;Heo, Ji-Yeon;Moon, Jin-Soo;Park, Jang-Yeon;Lee, Bong-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.235-239
    • /
    • 2010
  • In this study, we have fabricated two types of non-invasive fiber-optic respiration sensors that can measure respiratory signals during magnetic resonance (MR) image acquisition. One is a nasal-cavity attached sensor that can measure the temperature variation of air-flow using a thermochromic pigment. The other is an abdomen attached sensor that can measure the abdominal circumference change using a sensing part composed of polymethyl-methacrylate (PMMA) tubes, a mirror and a spring. We have measured modulated light guided to detectors in the MRI control room via optical fibers due to the respiratory movements of the patient in the MR room, and the respiratory signals of the fiber-optic respiration sensors are compared with those of the BIOPAC$^{(R)}$ system. We have verified that respiratory signals can be obtained without deteriorating the MR image. It is anticipated that the proposed fiber-optic respiration sensors would be highly suitable for respiratory monitoring during surgical procedures performed inside an MRI system.

Synthesis of $H_2$-Permselective Silica Films by Chemical Vapor Deposition (화학증착(CVD)에 의한 선택적 수소 투과성 실리카막의 제조)

  • 남석우;하호용;홍성안
    • Membrane Journal
    • /
    • v.2 no.1
    • /
    • pp.21-32
    • /
    • 1992
  • Hydrogen-permselective silica membranes were synthesized within tim walls of porous Vycor tubes by chemical vapor depostion of $SiO_2$. Film deposition was carried out using $SiCl_4$ hydrolysis either in the oppm shag reactants or in the one-sided geometry. At temperatures above $600^{\circ}C$ the permeation rate of hydrogen thorough the silica films varied between 0.01 and $025cm^3(STP)/cm^2-min-atm$ depending on the reaction geometry and the $H_2 : N_2$ permeation ratio was about 1000. Permeation rates of both $H_2$ and $N_2$ increased with increasing temperature. The silica membranes produced by one-sided deposition have higher hydrogen permmeation rates than those produced by the opposing reactants geometry although the membranes formed in an opposing reactants geometry were relatively stable during the heat treatment or after exposure to ambient air. These membranes can be applied to high temperature gas separations or membrane reactors once the film deposition process is optimized to get high permeability as well as good stability.

  • PDF

The Measurement Error owing to Leakage of Gaugeline in Orifice Flowmeter (오리피스 유량계에서 게이지라인 누설에 의한 계량오차)

  • Lee, Cheol-Gu;Ha, Young-Chul;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.143-148
    • /
    • 2003
  • This study was experimentally performed in order to estimate the errors due to the leakage of transmitter gaugelines in the orifice flow meter for natural gas. It would be a serious problem in safety if a large quantity of leak was occurred at the tubes or fittings like valve. But in most cases the safety problems might be rarely happened because the gas leak detectors could be operated in advance and the various kinds of inspection would be also fulfilled periodically. If the leakage was occurred continuously with an undetectable amount at the gaugelines for measuring the pressure or the differential pressure(DP), the amount of leakage might be an error or an unaccounted flow(UAE). In addition if the measuring value of pressure or DP were affected by the leakage, it might also be a measurement error. The experiments were performed to estimate the amount of leakage and to check the DP changes if it exited. First, through the measurement of the air pressure changes in the airtight container connected to a transmitter with gaugelines as the time passed, the amount of leakage causing from the fittings of gaugelines was roughly estimated. As changing the leak position of the gaugeline, the leak was intentionally made to break out. The variance of DP was checked as controlling the extent of leakage and compared to no leak conditions. Consequently, under the normal maintenance conditions, the result represented that the amount of leakage causing from the gaugelines was insignificant and also the DP changes on leakage conditions were too small to cause the errors of measurements.

  • PDF

Experimental Study for Evaporation Heat Transfer and Pressure Drop of R-22 and R-407C in an Inner Diameter of 4.3 mm and 6.4 mm (내경 4.3 mm와 6.4 mm관내 R-22와 R-407C의 증발 열전달과 압력강하에 관한 실험연구)

  • Son, Chang-Hyo;Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.43-49
    • /
    • 2008
  • The evaporation heat transfer coefficient and pressure drop of R-22 and R-407C in horizontal copper tubes were investigated experimentally. The main components of therefrigerant loop are a receiver, a compressor, a mass flow meter, a condenser and a double pipe type evaporator (test section). The test section consists of a smooth copper tube of 4.3 mm and 6.4 mm inner diameter. The refrigerant mass fluxes were varied from 100 to $300[kg/m^2s]$ and the saturation temperature of evaporator were 5 [$^{\circ}C$]. The evaporation heat transfer coefficients of R-22 and R-407C rise with the increase in mass flux and vapor quality. The evaporation heat transfer coefficient of R-22 for inner diameter tube of 4.3 mm and 6.4 mm is about $7.3{\sim}47.1%$ and $5.68{\sim}46.6%$ higher than that of R-407C, respectively.

  • PDF

Condensation Heat Transfer Characteristics of Tube-in-Tube Heat Exchanger using Small Diameter Tubes with R-22, R-407C and R-410A (세관을 이용한 Tube-in-Tube 열교환기내 R-22, R-407C 및 R-410A 응축열전달 특성)

  • Park, Woo-Jong;Choi, Kwang-Il;Park, Ki-Won;Oh, Jong-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.657-662
    • /
    • 2006
  • The present paper dealt with an experimental study of condensation heat transfer coefficients with refrigerant R-22, R-407C and R-410A, and was focused on pressure gradient and heat transfer coefficient in horizontal tube-in-tube heat exchangers using inner diameter of 4 mm, 3 mm and 2 mm in a 16.91 mm tube and length of 3,000 mm. Experiments were performed at inlet saturation temperature of 35 to $45^{\circ}C$ and mass flux ranges from 200 to $600 kg/m^2s$. The pressure gradient with inner tube diameter of 4.0 mm is higher 2.5 times than that of 8.0 mm. In tube-in-tube HEX, the pressure gradient of R-410A were lower than those of R-22 and R-407C. The condensation heat transfer coefficients increased with mass flux increase, but they decreased with saturation temperature increased. Condensation heat transfer coefficients of R-410A were a little higher than those of R-22 and R-407C. The condensation heat transfer coefficients of tube-in-tube HEX were about 40% higher than those of double tube HEX.

  • PDF