• Title/Summary/Keyword: Air to water

Search Result 6,150, Processing Time 0.032 seconds

Effect of Air Temperature Changes on Water Temperature and Hysteresis Phenomenon in Lake Paldang (기온 변화에 따른 팔당호 수온 영향 및 이력현상)

  • Yu, Soonju;Im, Jongkwon;Lee, Bomi
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.5
    • /
    • pp.323-337
    • /
    • 2020
  • Long-term continuous data were used to investigate changes in air and water temperature and temperature hysteresis at Lake Paldang, the largest source of drinking water in South Korea. Based on the temperatures at Yangpyeong, near Lake Paldang, using a seasonal Mann-Kendall test, the rate of change of increase in temperature over the last 27 years (0.060℃/yr, 1993-2019) was higher than that of during 47 years (0.048℃/yr, 1973-2019). The air and water temperatures in Lake Paldang and its influent rivers had a high correlation (R > 0.9, p < 0.005); however, the water temperature increased at rate slower than the river water temperature, and the water temperature decreased slowly as the air temperature fell. The depth-averaged water temperature also changed more slowly than the surface water of the lake both when the air temperature was high and when it was low. This is likely because the lake has a larger area and a longer heat retention time than rivers, resulting in a greater hysteresis of water temperature at lake.

Development of Semen Transport System for Cryopreservation and Fertility in Bull Sperm (소 정자의 동결 및 수정능력 향상을 위한 정액운반법의 개발)

  • Lee, Sang-Hee;Song, Eun-Ji;Woo, Jea-Seok;Lee, Seung-Hwan;Kang, Hee-Seol;Cheong, Hee-Tae;Yang, Boo-Keun;Park, Choon-Keun
    • Reproductive and Developmental Biology
    • /
    • v.37 no.3
    • /
    • pp.97-102
    • /
    • 2013
  • The objective of this study was to develop of semen transport system for cryopreservation and fertility in bull sperm. The ejaculated semen were diluted with Triladyl containing 20% egg-yolk for transportation. Diluted semen was transported by three methods that there were wrapping tissue (Tissue), sinking under $30^{\circ}C$ water (Water) and sinking between warm water and air (Air) methods. Semen was transported within 2 hours in $0.3^{\circ}C$. For this study, the freezing of diluted semen were added with Triladyl containing 20% egg-yolk. And frozen-thawed sperm were estimated with SYBR14/PI double stain for viability, FITC-PNA/PI double stain for acrosome reaction analysis and Rhodamine123 double stain for mitochondrial intact assessment. In results, live sperm (SYBR+/PI-) in Air treatment group ($43.3{\pm}4.7%$) was significantly (p<0.05) higher than other treatment groups (Tissue: $16.3{\pm}2.7%$ and Water: $27.5{\pm}3.1%$), dying sperm (SYBR+/PI+) in Air treatment group ($55.6{\pm}4.7%$) was significantly lower than other treatment groups (Tissue: $77.6{\pm}3.2%$ and Water: $67.6{\pm}3.3%$) (p<0.05). Acrosome reaction in Air treatment group ($0.2{\pm}0.1%$) within live sperm (PI negative region) was significantly (p<0.05) lower than other treatment groups (Tissue: $0.7{\pm}0.2%$ and Water: $0.5{\pm}0.1%$), the acrosome reaction in Air treatment group ($28.6{\pm}2.8%$) within all sperm also was significantly lower than other treatment groups (Tissue: $44.2{\pm}1.8%$ and Water: $36.2{\pm}2.0%$) (p<0.05). And mitochondrial intact in Air treatment group within live ($97.1{\pm}0.4%$) and all ($61.9{\pm}3.3%$) sperm were significantly higher than other treatment groups (Tissue: $85.2{\pm}3.3%$, Water: $87.8{\pm}2.9%$ within live sperm and Tissue: $49.28{\pm}3.7%$, Water: $42.0{\pm}3.1%$ within all sperm) (p<0.05). Therefore, we suggest that transportation by sinking method between warm water and air was beneficial to improvement of fertility in frozen-thawed in bull semen.

A Study on the Dehumidification Control to Prevent Condensation for Radiant Floor Cooling (바닥복사냉방의 결로방지를 위한 제습제어에 관한 연구)

  • 김용이;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 2003
  • In the forming of an integrated system of radiant floor cooling and dehumidifying, chilled coil can be used for cooling and dehumidification. Therefore, it is necessary to find the efficient control method which can eliminates latent load efficiently. This study has been conducted to find this method by dividing the dehumidification system into 3 types according to the control variables and analyzing characteristics of each system. To prevent the floor surface condensation, the amount of condensation can be manipulated by water temperatures, water flow rates in chilled coil, and air flow rates passing by it. So dehumidification system control can be divided into constant air flow control and variable air flow control. Regarding dehumidification control, variable air flow control, which eliminates latent load rather than sensible load, is preferable to constant flow control.

Efficient Management of the pH of the Wet Scrubber Washing Water for Risk Mitigation (리스크 완화를 위한 Wet Scrubber 세정수 pH의 효율적 관리)

  • Joo, Dong-Yeon;Seoe, Jae Min;Kim, Myung-Chul;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.85-92
    • /
    • 2020
  • Wet Scrubber reacts the incoming pollutant gas with cleaning water (water + absorbent) to absorb pollutants and release the clean air to the atmosphere. Wet scrubbers and packed tower scrubbers using this principle are widely used in businesses that emit acid gases. In particular, in the etching process using hydrochloric acid (HCl), alkaline washing water (NaOH) having a pH of about 8 to 11 is used to absorb a large amount of acid gas. However, These salts are attached to the injection nozzle (nozzle), filling material (packing), and the demister (Demister), causing air pollution, human damage, and inoperability due to clogging and acid gas discharge. Therefore, In this study, an improvement plan was proposed to manage the washing water with pH 3~4 acidic washing water. The test method takes samples from the Wet Scrubber flue measurement laboratory twice a month for 1 year. Hydrogen chloride (HCl) concentration (ppm) was measured, and nozzle clogging and scale conditions were measured, compared, and analyzed through a differential pressure gauge and a pressure gauge. As a result of the check, it was visually confirmed that the scale was reduced to 50% or less in the spray nozzle, filler, and demister. In addition, the emission limit of hydrogen chloride in accordance with the Enforcement Regulation of the Air Quality Conservation Act [Annex 8] met 3 ppm or less. Therefore, even if the washing water is operated in an acidic pH range of 3 to 4, it is expected to reduce air pollution and human damage due to clogging of internal parts, and it is expected to reduce maintenance costs such as regular cleaning or replacement of parts.

Submerging Performances of Automatic Submersible Buoy Operated by Air Control (공기 제어에 의한 자동 부침 부자의 부침 성능)

  • Kim, Tae-Ho;Hur, Jung-Gyu;Yang, Kyong-Uk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.743-749
    • /
    • 2010
  • The primary object of this study was to develop the control algorithm and program for automatic submersible buoy which is free to move vertically within the water column by adjusting weight and buoyancy forces by air control. The experiment was performed to validate the usefulness of the program in the indoor water tank. In the experiment, the automatic submerging and surfacing of the buoy were controlled by water-pressure gauge and air control system. The buoy is raised by injecting compressed air from a compressor and then is lowered by releasing the air. The submerging and surfacing characteristics of the buoy calculated with the numerical model were similar to measurements obtained with the experiment. It was concluded that the algorithm and program could be useful in analyzing various parameters and submerging mechanisms required to design new type of automatic submersible fish cage system.

Development of a Air-jet Water Sprayer for Dust Generation Control in the Production Sites of Gloves Making Plants (장갑공장의 분진발생 억제를 위한 에어젯 노즐의 개발)

  • Kim, Jin-Hyun;Choi, Hyun-kuk;Kim, Ki-Dong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.2
    • /
    • pp.69-78
    • /
    • 2009
  • Dust in the fabric production sites is increased by the static electricity in air which is generated in the manufacturing process. The static electricity is shown in inverse proportion to humidity of the production sites. The optimum humidity rate for the filament in the production process has been established as 65~75%. Where as, average humidity rate of production site is estimated as 40%. Therefore, it is necessary to raise the humidity rate by 30% to maintain appropriate humidity to control generation of static electricity and dust in the production sites. In this study, a new air-jet water sprayer was developed and it can produce $10{\mu}m$ sprayed particles. When the air-jet water sprayer was operated on the production site dust generation rate was shown far below the environmental standard. It is assumed that when the air jet sprayers was applied to 1,000 fabric machines of 5 gloves making plants, its productivity and rates of operation will be improved by value of about 2.5 billion Won a year.

  • PDF

A study on the Effect of SOB(Sulfur-Oxidizing Bacteria) Media on the Removal of Hydrogen Sulfide in Water of Septic Tank (SOB(Sulfur Oxidizing Bacteria) Media가 정화조의 수중황화수소 제거에 미치는 영향에 관한 연구)

  • Song, Homyeon;Cho, Jeongil;Kim, Taeksoo;Kwon, Sucheol;Yu, Hyeongsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.59-67
    • /
    • 2013
  • The odor occurring in the sewage system induces the displeasure, the disgust such as the headache, the vomit, etc. and increases the spiritual stress and disturbs the pleasant life of residents. These odors occur mainly in the area of combined sewage system treatment, being created in the personal sewage treatment plant such as septic tank and are incoming to sewage pipes and emitted to the outside through the manhole and the receiver, etc.; and this causes odors to the people. The Hydrogen Sulfide, the Methyl Mercaptan, the Ammonia, etc. are materials causing the odor, the more serious issue of odor is occurring since the septic tank of degradation process is being applied. The primary cause of odor is the decomposition of human feces in the septic tanks and sewage disposal facilities. The purpose of this study is reduction of hydrogen sulfide using air supplying and SOB(Sulfur-Oxidizing Bacteria). As a result of this study of the air supply system and the SOB media equipment by air supply, in case the air is injected to SOB media compared to the injection of air only, the removal efficiency the hydrogen sulfide was average 3.4 times higher.

Failure Analysis of Air Vent Connected with Heat Supply Pipeline Under Manhole (맨홀에 설치된 지역난방 열공급관 에어벤트의 전단부 파손 원인 규명)

  • Cho, Jeongmin;Chae, Hobyung;Kim, Heesan;Kim, Jung-Gu;Kim, Woo Cheol;Jeong, Joon Cheol;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.196-202
    • /
    • 2020
  • The air vent connected to a heat supply pipeline in the district heating system has been used to eliminate the existing air in the pipe, which has a detrimental effect on corrosion durability and heat efficiency. Recently, the air vent installed under a manhole for 22 years was corroded and several pinholes were detected in the front-end of the air vent. To identify the cause of the failure, thickness reduction, corrosion products, and water quality were examined. The corrosion damage was significant at the outside of the front-end of the air vent where the insulator was covered. While a thin oxide layer was formed in the interior of the tube, the coarse and porous corrosion products consisting of magnetite and hematite were found externally. Water flowing into the thermal insulator was absorbed by the insulator following hydrolysis. The hydrolyzed insulator ejected the corrosion factors such as Cl-, SO42-, and NH4+. The findings suggest that the corrosion under insulation due to rain water is the main cause of the underlying failure in the air vent.

Experimental study on feasibility test for removing particles in air scouring membrane backwash water with metal membrane (금속막을 이용한 저압 막 공기병용 역세척수 처리 타당성 연구)

  • Park, No-Suk;Yoon, Sukmin;Moon, Yong-Taik;Lee, Sun-Ju;Park, Sunghyuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.251-259
    • /
    • 2015
  • The main objective of this research is to study feasibility for applying metal membrane to remove particles from air scouring membrane backwash water. Also, the research was conducted to investigate the influence of polyamine coagulation on floc growth in membrane backwash water as pretreatment for removal particles. From the results of experiments for evaluating the influence of polyamine coagulation on floc growth, it was investigated that particles in the rage of $2{\sim}50{\mu}m$ grew up to $30{\sim}5,000{\mu}m$. In addition, all six metal membranes showed lower removal efficiency, which was 0.87~13.89%, in the case of no polyamine coagulant. On the other hand, in the case of injecting polyamine coagulant, those did extremely high efficiency in 56~92%. From the SEM(Scanning Electron Microscope) images of filtered wiremesh and metal foam membrane, sieve effects were predominant for liquid solid separation in wiremesh and adsorption and diffusion capture effects were predominant in metal foam membrane.

A Study on Bubble Behavior Generated by an Air-driven Ejector for ABB (Air Bubble Barrier) (II): Comparison of Bubble Behavior with and without Ejector (공기구동 이젝터를 이용한 ABB (Air Bubble Barrier)의 기포거동 특성 연구 (II): 기포거동 특성의 비교 분석)

  • Seo, Hyunduk;Aliyu, Aliyu Musa;Kim, Hyogeum;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.15 no.2
    • /
    • pp.59-67
    • /
    • 2017
  • To verify floatability of ABB (Air bubble barrier), we compared bubble swarm behavior with and without the air-driven ejector. Experiment was conducted using the fabricated air-driven ejector with 5 mm nozzle on the bottom of 1 m3 water tank. Reynolds number of air in the nozzle was ranged 1766-13248. We analyzed data with statistical method using image processing, particle mage velocimetry (PIV) and proper orthogonal decomposition (POD) analysis. As a result of POD analysis, there was no significant eigenmode in bubbly flow generated from the ejector. It means that more complex turbulent flows were formed by the ejector, thereby (1) making bubbles finer, (2) promoting three-dimensional energy transfer between bubble and water, and (3) making evenly distributed velocity profile of water. It is concluded that the air-driven ejector could enhance the performance of ABB.