• 제목/요약/키워드: Air tightness

검색결과 120건 처리시간 0.022초

한국형 고속전철 객차 개발 연구 (The Study of passenger Car Design of korean High Speed Train)

  • 박만수;박광복;임성근
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.563-575
    • /
    • 2000
  • This study was carried out about the system engineering, the design, and Mock-up for the development of passenger car of Korean High Speed Train of maximum operating speed of 350km/h. The design was studied to carbody section & lay out, ring, fitting, carbody, electrical system based on Korean-TGV. The design of aluminium alloy carbody which was enabled to reduce the weight of carbody structure and was studied with construction of air-tightness. Air pressure controlled system provided to comfort passenger due to a reduction of difference pressure between inside and outside of passenger room on running of the tunnel. The Interior design was performed in order to satisfy high speed and comfort to study by the modern design. The electrical system was designed two parts of logic and network for high reliability of train.

  • PDF

전동차 소음저감을 위한 슬라이딩플러그 출입문 개발 (Development of a Sliding-Plug Entrance Door System for Urban Electric Transit Unit to Reduce Inside Noise Level)

  • 서승일;임영호;신동국
    • 한국철도학회논문집
    • /
    • 제5권2호
    • /
    • pp.112-117
    • /
    • 2002
  • Reduction of noise level in the cabin of urban transit unit is an important issue to enhance the comfortability of passengers. It is made clear that a cause of increased noise level in cabin is the imperfect airtightness of entrance doors. In this study, the sliding-plug door system is developed to reduce the noise level of cabins by securing the airtightness of entrance door. The sliding-plug door system is composed of air-driven engine, swing arms, guide rails, guide rollers and locking devices. It is economical owing to using the previous door engine system. It is also adequate for the platform system of our subway station. It was tested to prove the reliability of system and was applied to standard urban transit unit. The effectiveness of noise reduction in cabin resulting form the sliding-plug door system was confirmed by test results.

3L House의 설계, 시공 및 평가 (The Technology Applied 3 Liter House, Super Energy Saving Building)

  • 박선효;박용승;원종서
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.814-819
    • /
    • 2006
  • This research is on the design and introducing of integrated thermal performance of super energy saying building, called 3 Liter house which can be sustained with 3 liter oil(kerosene) per $yr.m^2$. 3 liter houses(Passive houses) offer extended living comfort with only 15 to 20% of the space heating demand of conventional new building. To achieve this purpose, the efficiency of building components is improved, such as walls, windows or ventilation system and the construction technology is improved, such as the prevention of thermal bridge and the air tightness. The fuel cell is used as alternative energy. Energy consumption of 3L house is 2.08 [liter/$yr.m^2$] in monitoring result of $2006/2/1{\sim}2/7$ and ACH50 is 0.67 in result of Blow Door Test, therefore 3L House is well- insulated and well- airtighted house.

  • PDF

동절기 공동주택 갱폼 개구부 천막보양에 따른 보양 온도 분포 분석 (The temperature distributions of the curing space according to blocking the opening of gang-form at the apartment in the cold weather)

  • 조홍범;송진희;김영선;최지수;이규남
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.140-141
    • /
    • 2022
  • CFD analysis was performed to analyze the temperature distribution of the inner space of the curing house according to blocking the opening of the gang-form with a tent in case of concrete pouring and heat curing of the apartment house during the winter season. If the gang-form opening is closed with a tent during internal heating using a hot air blower in the winter, the internal temperature rises compared to the non-reserved due to air-tightness of the curing spaces, and uniform temperature distribution can be ensured. In addition, it is possible to increase curing efficiency by reducing the amount of heat supplied and shortening the heating time.

  • PDF

모헤어 개수, 틈새 길이 및 축소된 길이의 창문 기밀성 및 개폐력에 대한 실험적 연구 (Experimental Research of Window Air Tightness and Opening Force with Respect to Mohair Number, Clearance and Shortened Length)

  • 김승재;박종준;김영일
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.195-203
    • /
    • 2018
  • Mohair is widely used as an airtight material for filling the gap between a window frame and sash. The purpose of this study is to investigate infiltration rate and opening force of sliding windows according to the mohair installation conditions. Infiltration experimental apparatus was set up, and the experimental results were applied to windows to find a correlation between infiltration rates and opening forces. When 4 rows of mohair were installed, the infiltration rate increase became 27.1% per clearance length increase of 1 mm, and the infiltration rate decrease became 5.7% per shortened length increase of 0.1 mm. For 4 rows of mohair, the opening force decreased by 28.2% as the clearance increased by 1 mm, and it increased by 9.3% as the shortened length increased by 0.1 mm.

실험계획법에 의한 수직샤프트내 압력분포에 영향을 미치는 인자간 상관관계 분석 (Correlation Analysis of Parameters affecting Pressure Distributions in Vertical Shafts by Design of Experiments)

  • 한화택;신철용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.883-888
    • /
    • 2008
  • Various effluents generated in cooking processes contribute a great deal to indoor air pollution among many other indoor pollutants such as dusts from outdoor and carbon dioxide from human body. Kitchen exhaust hoods are not believed to exhaust indoor contaminants properly in many cases, while generating too much noise. Instead of focusing on individual products of kitchen hoods, we should address the problem by attacking the ventilation system as a whole including vertical shafts and building air-tightness. In this study, it is intended to investigate the pressure distribution along the vertical shaft depending on various system parameters, such as shaft size, concurrent hood usage rate, roof fan, inlet pressure loss, and outdoor temperature. The maximum static pressure in the vertical shaft has been obtained using the method of design of experiments and analyzed by the analysis of variance. The results can be used for the design of kitchen exhaust systems by analyzing the pressure distributions in vertical shafts.

  • PDF

숨쉬는 벽체를 적용한 건물에서의 실내공기질(IAQ) 개선 효과 분석 (IAQ improvement effect analysis in Dynamic Breathing Building(DBB))

  • 박용대;이진숙;강은철;이의준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.748-753
    • /
    • 2008
  • In modern buildings, the air-tightness and insulation for energy saving resulted in degradation of Indoor Air Quality(IAQ). It has brought out new diseases such as New Building Syndrome(NBS) and Sick Building Syndrome(SBS) to the tenants of such buildings. As a result, researches on the Dynamic Breathing Building(DBB) are being undertaken to minimize energy loss as well as to improve IAQ. DBB is a state-of-the-art technology to build channels inside the wall so that air migrates between indoor and outdoor, which improves insulation performance and IAQ. This study attempts to evaluate the improvement of DBB employed in real buildings. As analyzing tools, IAQ improvement and particle degradation while were evaluated while the required indoor ventilation rate was satisfied. DBB were installed in the twin test cells at Korea Institute of Energy Research(KIER). From the test, IAQ was compared with outdoor air base on the concentration of particle matter(PM10). As a results, the concentration of particle dust (PM10) within the breathing walls was reduced by 80% at 0.7 ACH, 67% at 2 ACH, 63% at 3 ACH respectively. As ACH is higher, Dnamic Isulation(DI) and normal wall permit more PM10 particles being infiltrated.

  • PDF

중국 수출용 아웃도어 웨어 개발을 위한 중국 소비자의 한류에 대한 태도 및 착용실태 조사 - 중국인 관광객을 대상으로 - (A Study of Chinese Consumer's Attitude towards Korean Wave and Wearing Condition for Outdoor Clothing Development into the China Market - Focused on Chinese Tourist -)

  • 김지은;손재민;김미라;최혜선
    • 한국의류산업학회지
    • /
    • 제16권4호
    • /
    • pp.614-624
    • /
    • 2014
  • This study is intended to offer basic data for developing outdoor clothing exported to China by identifying how Chinese consumers use outdoor clothing. To accomplish the objective, a survey was conducted on 300 male and female Chinese tourists in their 10s to 40s who have purchased outdoor clothing before. As more than twice as many respondents said they wear sweatsuit or everyday clothes for mountain-climbing instead of outdoor clothing, the necessity of outdoor clothing is obviously perceived at a low level. Among them, 57.4% wear outdoor clothing as townwear in everyday lives, and other respondents are dissatisfied with the design. Thus, it is necessary to develop townwear-style design. When buying outdoor clothing, wearability was the biggest consideration. Also, the first criteria for evaluating outdoor clothing was practicality for mountain-climbing activities. The functionality of outdoor clothing they needed the most was air permeability. As for outdoor clothing top, the main inconvenience was tightness around the neck. As for bottoms, it was tightness of pants when bending knees. In terms of areas to be improved, the No. 1 was unformed design. Thus, it is imperative to develop design of diverse styles. As the Chinese outdoor clothing market has grown significantly in recent years, the following should be executed by domestic companies before advancing to the market. First, they should form Korean brand image and boost the brand awareness with various activities, amid Korean Wave. Second, they should develop preferred designs among Chinese consumers and strengthen functionality of products, based on consumer survey.

한지창호의 실내 온.습도 조절효과에 관한 실험적 연구 (An Experimental Study on the Effect of Hanji Windows on Indoor Air Temperature and Humidity Control)

  • 장길수;박사근;송민정;신훈
    • 한국주거학회논문집
    • /
    • 제17권2호
    • /
    • pp.125-134
    • /
    • 2006
  • The tightness of windows have devoted to the improvement of thermal insulation and energy saving in buildings. But it is known that this tightness causes some side effects such as low ventilation, low capacity to humidity and temperature control and these are not profitable for inhabitants. To act on these side effects, Korean traditional windows which are composed of Han-Ji(Koreand traditional paper) and Chang-Sal(Korean traditional wooden frame) have been studied to get a reasonable solutions for these problems. In this study, to compare the thermal and humidity control performance of current window(12 mm pair) and Korean traditional windows, frames which are made of existing window and Korean traditional windows are adapted to scale model house and then humidity and temperature of in and out of scale model house are measured and analysed. The results of this study are followings ; 1) When Korean traditional window charges 20cm(1/8 of total window area) from total window area, Han-Ji window has higher thermal insulation than that of existing window in daytime. There is the most big thermal difference when double faced with double-ply Han-Ji window is placed to mock-up house. In night-time, the temperature difference is very small so this means that Korean traditional window is good to cover direct sunlight in daytime and reduce the temperature of balcony. One faced with one-ply han-Ji window has the best humidity penetration performance among three type of Korean traditional windows. 2) When Korean window area enlarged to 40cm(1/4 of total window area), the function of 40cm width Han-Ji window is higher than that of 20cm's. This means that enlargement of Han-Ji window cover direct sunlight more and is more efficient in humidity penetration.

사무용 건물에서 전열교환 환기시스템과 일반공조기의 냉방에너지 비교분석에 관한 연구 (A Comparative Analysis on Cooling Energy of Heat Recovery Ventilator and Air Handling Unit in the Office Building)

  • 장지훈;김현수;어진선;이승복;김병선
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.123-128
    • /
    • 2016
  • Purpose: In order to save the energy consumption of buildings, buildings have been constructed with high performance insulation or airtightness. However, high performance insulation or air tightness has led to a poor indoor air quality. Therefore, HRV(Heat Recovery Ventilator) has received attention to save the energy consumption and insure a good air quality. Because existing research is almost about the performance of HRV in residential buildings, This study analyzed the effect of HRV on cooling energy consumption in commercial office building. Method: This study was proceeded at commercial office building in In-cheon. In order to evaluate the energy consumption of HRV, this study proposed two methods: estimating energy consumption of the room installed AHU(Air Handling Unit) system; estimating energy consumption of the room installed HRV system. Therefore, comparison of two methods was proceeded to evaluate energy performance of each method. Result: As the result of comparison between rooms installed AHU and HRV, the experiment showed that energy consumption of the room installed HRV system is about 22% less than the room of AHU system. This conclusion is considered because the room installed HRV system have maintained temperature well at set point temperature $26^{\circ}C$.