• Title/Summary/Keyword: Air quality simulation

Search Result 259, Processing Time 0.028 seconds

Numerical Modeling of Pollutants using Local Wind Model in Gwangyang Bay, Korea (국지순환풍 모델을 이용한 광양만권 대기오염물질의 수치모델링)

  • 이상득
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.1
    • /
    • pp.13-23
    • /
    • 2003
  • A local wind model and a three dimensional local environmental model including advection, diffusion, deposition. and photochemical reactions were performed at Gwangyang Bay, Korea, to predict air flow and air pollutants concentrations. A large grid was used, and nesting method was employed for small grid calculation. From the meterological module simulation, we were able to reproduce local wind characteristics such as sea/land winds and mountain/valley winds simulation at Gwangyang Bay. In addition, the concentration module showed high concentration regions at Yosu industrial complex, Gwangyang steel company. and Container anchor. It was also seen that air pollutants were dispersed by sea/land winds. A comparison between the measurement and the prediction of sulfur dioxide and nitric oxide, which are relatively low-reacted pollutants, was performed. However, the measured nitrogen dioxide and ozone concentrations were higher than the simulated ones. Particularly, ozone concentration between 8 a..m. and 8 p.m. agreed well, but the measured ozone during the rest of time were generally higher.

A Numerical Simulation of Air-Cooled Ammonia/Water GAX Absorption Cooling Cycle (공냉형 암모니아/물 GAX 흡수식 냉동 사이클의 수치 해석)

  • Jeong, S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.488-500
    • /
    • 1995
  • An air-cooled ammonia/water GAX(Generator-Absorber heat eXchange) absorption cooling cycle is proposed and its performance is numerically evaluated. It is shown that the performance of the system is greatly dependent on the quality of the refrigerant leaving the evaporator. For any refrigerant concentration in the investigated range(99.1~99.9% ammonia), the cycle COP(coefficient of performance) reaches the highest value, when some amount(about 7%) of refrigerant evaporates in the refrigerant heat exchanger. Among temperature differences in various heat exchangers, the temperature difference between GAX-absorber and the GAX-generator shows the greatest effect on the system performance, whereas pressure losses cause no significant decrease in COP. The system COP increases almost linearly with increasing evaporator temperature, decreasing absorber temperature or decreasing condenser temperature. If both absorber and condenser temperature increase simultaneously, the decrease in the COP becomes larger.

  • PDF

Development of CAPSS2SMOKE Program for Standardized Input Data of SMOKE Model (배출 모델 표준입력자료 작성을 위한 CAPSS2SMOKE 프로그램 개발)

  • Lee, Yong-Mi;Lee, Dae-Gyun;Lee, Mi-Hyang;Hong, Sung-Chul;Yoo, Chul;Jang, Kee-Won;Hong, Ji-Hyung;Lee, Suk-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.838-848
    • /
    • 2013
  • The Community Multiscale Air Quality (CMAQ) model is capable of providing high quality atmospheric chemistry profiles through the utilization of high-resolution meteorology and emissions data. However, it cannot simulate air quality accurately if input data are not appropriate and reliable. One of the most important inputs required by CMAQ is the air pollutants emissions, which determines air pollutants concentrations during the simulation. For the CMAQ simulation of Korean peninsula, we, in general, use the Korean National Emission Inventory data which are estimated by Clean Air Policy Support System (CAPSS). However, since they are not provided by model-ready emission data, we should convert CAPSS emissions into model-ready data. The SMOKE is the emission model we used in this study to generate CMAQ-ready emissions. Because processing the emissions data is very monotonous and tedious work, we have developed CAPSS2SMOKE program to convert CAPSS emissions into SMOKE-ready data with ease and effective. CAPSS2SMOKE program consists of many codes and routines such as source classification code, $PM_{10}$ to $PM_{2.5}$ ratio code, map projection conversion routine, spatial allocation routine, and so on. To verify the CAPSS2SMOKE program, we have run SMOKE using the CAPSS 2009 emissions and found that the SMOKE results inherits CAPSS emissions quite well.

PM2.5 Source Apportionment Analysis to Investigate Contributions of the Major Source Areas in the Southeastern Region of South Korea (동남지역 주요 배출지역의 PM2.5 기여도 분석)

  • Ju, Hyeji;Bae, Changhan;Kim, Byeong-Uk;Kim, Hyun Cheol;Yoo, Chul;Kim, Soontae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.517-533
    • /
    • 2018
  • We utilize the CAMx (Comprehensive Air Quality Model with eXtensions) system and the PSAT (Particulate Source Apportionment Technology) diagnostic tool to determine the $PM_{2.5}$ concentration and to perform its source apportionment in the southeastern region of South Korea. For a year-long simulation, eight local authorities in the region such as Pohang, Daegu, Gyeongju, Ulsan, Busan-Gimhae, Gosung-Changwon, Hadong, and all remaining areas in Gyeongsangnam-do, are selected as source areas based on the emission rates of $NO_x$, $SO_x$, VOC, and primary PM in CAPSS (Clean Air Policy Support System) 2013 emissions inventory. The CAMx-PSAT simulation shows that Pohang has the highest $PM_{2.5}$ self-contribution rate (25%), followed by Hadong (15%) and Busan-Gimhae (14%). With the exception of Pohang, which has intense fugitive dust emissions, other authorities are strongly affected by emissions from their neighboring areas. This may be measured as much as 1 to 2 times higher than that of the self-contribution rate. Based on these estimations, we conclude that the efficiency of emission reduction measures to mitigate $PM_{2.5}$ concentrations in the southeastern region of South Korea can be maximized when the efforts of local or regional emission controls are combined with those from neighboring regions. A comprehensive control policy planning based on the collaboration between neighboring jurisdictional boundaries is required.

A Study on the Simulation Evaluation of IAQ at the Process of Building Construction (건물 시공단계의 실내공기질 시뮬레이션 평가 연구)

  • Choi, Jeong-Min;Cho, Sung-Woo;Park, Chang-Seob;Park, Min-Yong;Lee, Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.60-67
    • /
    • 2007
  • The purpose of this study is to evaluate indoor air quality at the stage of building construction. To check the IAQ at the stage of construction IAQX simulation program developed by EPA was used and the values of TVOC were analyzed with time-series. The Simulation conditions are as follows. 1) Ventilation rate, 2) Time schedule of works, 3) Material change. Through this simulation, the major factors which affect the IAQ were analyzed and the importance of empirical data about the time-series emission rate of concerned material could be confirmed.

Air Damping Evaluation for Laterally Driven Electrostatic Repulsive-Force Microactuators Using Creeping Flow Model (수평 구동형 정전 반발력 마이크로엑추에이터의 Creeping 유동 모델에 의한 공기 감쇠)

  • Lee, Gi-Bang;Seo, Yeong-Ho;Jo, Yeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.11
    • /
    • pp.581-588
    • /
    • 2001
  • This paper presents theoretical and experimental study on the quality-factor of the laterally oscillated electrostatic microactuator, driven by a lateral repulsive-force generated by the asymmetry of planar electric field. The quality-factor of the repulsive-force microactuator using a creeping flow model of the ambient air is evaluated. By filling the simulation results of damping force, we evaluate the dimensionless damping force, $\alpha$, thereby obtaining an analytical damping force, F, in the form of $F=\mu\; \alphaUL,\; where\; \mu,$ U and L denote the air viscosity, the velocity and the characteristic length of the movable electrodes. The measured quality-factor increases from 12 to 13 for the DC bias voltage increased from 60V to 140v. The theoretical quality-factor estimated from the creeping flow model increases from 14.9 to 18.7. Characteristics of quality-factor of the repulsive-force microactuator have been discussed and compared with those of the conventional attractive-force microactuator.

  • PDF

Air-traffic dispatching scheduling in terminal airspace (공항접근영역 항공교통 Dispatching 스케줄링 연구)

  • Jeong, Sun-Jo;Cho, Doo-Hyun;Choi, Han-Lim
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.11
    • /
    • pp.973-980
    • /
    • 2016
  • An air traffic management (ATM) has been studied in a variety of fields to utilize an air traffic capacity efficiently and solve a congested air traffic situation due to an increment of an air traffic demand. In this paper, an air traffic management, which is related with controlling and determining the sequencing of an aircraft approaching to an airport, in terminal control area is studied. This paper focuses on scheduling algorithms with a given problem for the air traffic management with operational constraints, such as a space separation, an overtaking on the same air-route, and a route merge point (a scheduling point). For a real-time calculation, the presented algorithms focus on dispatching heuristic rules which are able to assign tasks in a fast time period with an adequate performance, which can be demonstrated as a proper and realistic scheduling algorithm. A simulation result is presented to illustrate the validity and applicability of the proposed algorithm. Each scheduling rule is analyzed on the same static and dynamic air traffic flow scenario with the ATM Monte-Carlo simulation.

Evaluation of Energy Consumption of HVAC System for Air Filter Pressure Difference Change in Commercial Buildings (공조설비의 필터차압 변화에 따른 에너지 소비성능 평가)

  • Won Keun-Ho;Kwak Ro-Yeul;Huh Jung-ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1227-1233
    • /
    • 2004
  • Air handling unit (AHU)'s air filter pressure difference is important for energy consumption and indoor air quality. Both energy Performance data and air filter differential pressure of AHU in real office buildings were monitored and analyzed to investigate quantitatively energy impact as dust buildup level on air filter grows. We also modeled and simulated CAV system using HVACSIM+ program to examine the energy effect of dust buildup on filters. Through analysis of time series pressure drop data, the filter pressure difference rate has been increased due to cumulative supply air flow rate increase. As filter pressure drop increased to 1 inch water column, it is found that the supply air flow rate was decreased by 10%, the chilled water flow rate was increased by 5.9% and the pump energy consumption was increased to 5.9%.

Childrens' Health Risk Assessment on Indoor Hazardous Air Pollutants of Preschool Facility (유아교육시설 내 실내공기유해오염물질에 대한 어린이 건강위해성평가)

  • Koh, Yeon-Jung;Kim, Shin-Do;Park, Suk-Young;Jang, Seong-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.2
    • /
    • pp.78-85
    • /
    • 2009
  • In this study, the hazard rate of the indoor environment of Children's Educational Facilities in Seoul was conducted, in order to determine how the indoor environments of these facilities, where infants and children spend the most time of their away from home day, can effect their health. The way of measurement and analysis were done according to the Indoor Air Quality Standard Method, and the Risk Assessment was accomplished with several significant ways - Hazard Identification, Exposure Assessment, Dose-response Assessment, Risk Characterization, which are deighed by National Research Council (NRC). On each exposure factors, documentary and questionary research such as Epidemiological study and Toxicological study were conducted. The result of the CTE (Central tendency exposure) of Formaldehyde and Benzene by Monte-Carlo simulation was $6.79{\times}10^{-6}$, $2.50{\times}10^{-7}$ which in the case of Formaldehyde exceeded the permitted standard ($10^{-6}$) of the US EPA. The RME(Reasonable maximum exposure) was $7.31{\times}10^{-5}$, $2.65{\times}10^{-6}$ which did not exceed $10^{-4}$, the maximum permitted standards in the US EPA.

A Performance Evaluation of Plate Type Enthalpy Exchanger through CFD Analysis of Elements (열 교환 소자 형상의 CFD 시뮬레이션을 통한 판형 전열 교환기 성능평가)

  • Kang, In-Sung;Ahn, Tae-Kyung;Park, Jin-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • In order to better save energy, many buildings have been constructed with high levels of insulation and airtightness in recent years. Additionally, having high quality indoor air has become more relevant, necessitating a ventilating system. This study is aimed at evaluating the performance of a humidity exchanger through computational fluid dynamics (CFD) analysis of elements for the purpose of providing comfortable indoor air and reduced energy consumption. The simulation was conducted with three different shapes (triangle, rectangular, and curve) of heat exchanger elements, in order to find the most effective element. A follow-up simulation then proved the efficiency of the chosen humidity exchanger, which was selected by analyzing the results of the preceding simulation, comparing study data with measurement data from the Korea Testing Laboratory (KTL). The resulting analysis revealed that the rectangular element showed the lowest level of efficiency in both heating and cooling, while the curved element showed the highest level of efficiency in both heating and cooling.