• Title/Summary/Keyword: Air quality monitoring system

Search Result 160, Processing Time 0.032 seconds

Optimization of Air Quality Monitoring Networks in Busan Using a GIS-based Decision Support System (GIS기반 의사결정지원시스템을 이용한 부산 대기질 측정망의 최적화)

  • Yoo, Eun-Chul;Park, Ok-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.526-538
    • /
    • 2007
  • Since air quality monitoring data sets are important base for developing of air quality management strategies including policy making and policy performance assessment, the environmental protection authorities need to organize and operate monitoring network properly. Air quality monitoring network of Busan, consisting of 18 stations, was allocated under unscientific and irrational principles. Thus the current state of air quality monitoring networks was reassessed the effect and appropriateness of monitoring objectives such as population protection and sources surveillance. In the process of the reassessment, a GIS-based decision support system was constructed and used to simulate air quality over complex terrain and to conduct optimization analysis for air quality monitoring network with multi-objective. The maximization of protection capability for population appears to be the most effective and principal objective among various objectives. The relocation of current monitoring stations through optimization analysis of multi-objective appears to be better than the network building for maximization of population protection capability. The decision support system developed in this study on the basis of GIS-based database appear to be useful for the environmental protection authorities to plan and manage air quality monitoring network over complex terrain.

Real-time Air Quality Monitoring System Based on Wireless Network (무선네트워크기반 공기질 실시간 모니터링 시스템)

  • Paik, Seung Hyun;Lee, Jun Yeong;Jung, Sang Woo;Park, Hong Bae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.3
    • /
    • pp.143-151
    • /
    • 2016
  • In this paper, a real-time air quality monitoring system based on wireless network is designed and implemented for industrial park or multiuse facilities. The existing gas detector is high price and hard to apply the remote monitoring system. On the other hand, demand for air quality monitoring is increasing because of industrial gas accident, air pollution, and so on. In Korea, indoor air regulation was established by law. According to indoor air regulation, CO2, CO, and NO2 are important gases as the air quality standard. So we study the gas detector for indoor air quality and the wireless network system. The wireless network consist of sensor network and WCDMA to apply various place. To verify the performance of the implemented gas detector, the gas measurement experiment is performed in laboratory environment by using the realized gas detecting wireless sensor node. And we evaluate the experiment results.

A Low Power Wireless Communication-based Air Pollutants Measuring System (저전력 무선통신 기반 대기오염 측정시스템)

  • Kang, Jeong Gee;Lee, Bong Hwan
    • Journal of Information Technology Applications and Management
    • /
    • v.28 no.6
    • /
    • pp.87-95
    • /
    • 2021
  • Recently interest for air pollution is gradually increasing. However, according to the environmental assessment of air quality, the level of air pollution in the nation is quite serious, and air pollutants measuring facilities are also not enough. In this paper, a secure air pollutants sensor system based low power wireless communication is designed and implemented. The proposed system is composed of three parts: air pollutants measuring sensors module, LoRa-based data transmission module, and monitoring module. In the air pollutants measuring module, the MSP430 board with six big air pollutants measuring sensors are used. The air pollutants sensing data is transmitted to the control server in the monitoring system using LoRa transmission module. The received sensing data is stored in the database of the monitoring system, and visualized in real-time on the map of the sensor locations. The implemented air pollutant sensor system can be used for measuring the level of air quality conveniently in our daily lives.

Query-based Indoor air Quality monitoring system Using wireless sensor network inside the Building (빌딩내에서 무선센서네트워크를 이용하는 쿼리기반의 실내공기 질 모니터링시스템)

  • Lee, Seung-Chul;Chung, Wan-Young
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.627-628
    • /
    • 2008
  • This paper proposes an indoor air Quality monitoring system for measuring various indoor air qualities using IEEE 802.15.4 based wireless sensor network. For indoor air quality monitoring, sensor nodes include carbon monoxide sensor and dust sensor were used. The wireless network by deployed sensor nodes has limited energy, computing, communication capabilities and memory sizes. In this paper, the query process in indoor air quality monitoring was designed to improve the limited sensor node resources such as battery consumption and networking.

  • PDF

Problems and Improvements in the Quality Control of the Air Monitoring Network (대기오염측정망 정도관리의 문제점과 개선방향)

  • Kim, Duck-Sung;Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.8
    • /
    • pp.847-855
    • /
    • 2020
  • This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.

Research of Real-Time Remote Operation for Quality Improvement of the Air-compressor : Case Study of Reciprocating Air-compressor (공기압축기의 품질향상을 위한 실시간 원격 운영시스템 연구 : 왕복동형 공기압축기 대상으로)

  • Im, Sang-Don;Kim, Jong-Rae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.1
    • /
    • pp.33-40
    • /
    • 2014
  • Air compressor is an important facility with electric power in the industry. However, because of the noise and vibration of air compressor and is installed outside the building management difficulty. In this study, MCP (Micro Control Processor) to remote monitoring of the air compressor via the compressed air through improved quality and allows stable maintenance were designed. So, increase the productivity improvement of energy-saving effect can be obtained. Remote real-time information stored on your PC to manage air compressor equipment was higher reliability. Monitoring system is developed in this study was applied to embedded systems. It is easy to install air compressor, and low maintenance costs was to raise the economic impact.

Iot based Indoor Air Quality Monitoring System (Iot 기반 실내 공기오염 측정 시스템)

  • Kim, Ungtae;Kim, Yong-Chul;Kwak, Sooyeong
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.143-151
    • /
    • 2016
  • Many people interested in indoor air quality monitoring since they spend a majority of their time indoors such as homes and offices. This paper proposes the effective indoor air quality monitoring system and it can gauge carbon dioxide, particulate matter and VOCs(Volatile Organic Compounds) which can be harmful to humans. The proposed system is composed of three main modules which are device, web server, and mobile application. In order to evaluate the performance, we tested two cases which are candle and smoke. We monitor the condition of indoor air quality with our mobile application. Also, we developed the information graphics to compare the condition of air quality between indoor and outdoor and this mobile application improves usability.

Current Status and Development of Modeling Techniques for Forecasting and Monitoring of Air Quality over East Asia (동아시아 대기질 예보 및 감시를 위한 모델링 기술의 현황과 발전 방향)

  • Park, Rae Seol;Han, Kyung Man;Song, Chul Han;Park, Mi Eun;Lee, So Jin;Hong, Song You;Kim, Jhoon;Woo, Jung-Hun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.407-438
    • /
    • 2013
  • Current status and future direction of air quality modeling for monitoring and forecasting air quality in East Asia were discussed in this paper. An integrated air quality modeling system, combining (1) emission processing and modeling, (2) meteorological model simulation, (3) chemistry-transport model (CTM) simulation, (4) ground-based and satellite-retrieved observations, and (5) data assimilation, was introduced. Also, the strategies for future development of the integrated air quality modeling system in East Asia was discussed in this paper. In particular, it was emphasized that the successful use and development of the air quality modeling system should depend on the active applications of the data sets from incumbent and upcoming LEO/GEO (Low Earth Orbit/Geostationary Earth Orbit) satellites. This is particularly true, since Korea government successfully launched Geostationary Ocean Color Imager (GOCI) in June, 2010 and has another plan to launch Geostationary Environmental Monitoring Spectrometer (GEMS) in 2018, in order to monitor the air quality and emissions in/around the Korean peninsula as well as over East Asia.

Air Quality Monitoring System Using NDIR-CO$_2$ Sensor for Underground Space based on Wireless Sensor Network (비분산적의선 CO$_2$센서를 이용한 무선 센서 네트워크 기반의 지하 공기질 모니터링 시스템)

  • Kwon, Jong-Won;Kim, Jo-Chun;Kim, Gyu-Sik;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.28-38
    • /
    • 2009
  • In this study, a remote air quality monitoring system for underground spaces was developed by using NDIR-based CO$_2$ sensor. And the remote monitoring system based on wireless sensor networks was installed practically on the subway station platform. More than 6.5 million citizens commutate everyday by the Seoul subway transportation that is the most typical public transportation. They concern about air quality with increasing interest on public health or many workers in subway stations or underground shopping centers. Recently, the Korean Ministry of Environment has operated the air quality monitoring system in some subway stations for testing phase. However, it showed many defects which are large-scale, high-cost and maintenance of precision sensors imported from abroad. Therefore this research includes the reliability test and a theoretical study about the inexpensive commercialized CO$_2$ sensor for reliable measurement of air quality which changes rapidly by the surrounding environments. And then we develop the wireless sensor nodes and the gateway applied for remote air quality monitoring. In addition, web server program was realized to manage air quality in the subway platform. This result will be valuable for a basic research for air quality management in underground spaces for future study.

Investigation on the Validation for Designating Air Quality Control Region among Provincial Cities by the Data Measured with Air Quality Monitoring Network (대기오염 측정 자료에 의한 지방도시의 대기환경규제지역 설정에 관한 타당성 검토)

  • Yu, Mee-Seon;Yang, Sung-Bong;Woo, Kyung-Bin
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.181-190
    • /
    • 2016
  • Regional air quality regulation is a system that allows the Minister of Environment to designate the local area as air quality control region where the concentrations of air pollutants are exceeding the environmental standards, and the local governments that administrate the regulated area have to develop and practise a plan for reducing the air pollutants. From the data observed yearly by the monitoring stations in 8 provincial cities with more than 0.5 million people was judged the compliance with air quality standards in each municipality for the period of 2003 to 2013. As the result of investigation on air pollutants concentrations of each city, it was found that there was no station that exceeds the ambient air quality standards of CO, $SO_2$ and 24-hour $NO_2$. But all municipalities exceeded the standards of 8-hour $O_3$, annual and 24-hour $PM_{10}$, and therefore 8 municipalities can be designated to be under the local air regulation. For the annual $NO_2$ were the monitoring sites necessary requirements for designation of the air quality regulation region in Cheongju, Cheonan, Daejeon and Gwangju area. Incase of 1-hour $O_3$, some of stations in Pohang, Cheongju, Cheonan and Changwon area were over the designation standards for the air quality control region.