• Title/Summary/Keyword: Air mattress

Search Result 31, Processing Time 0.027 seconds

Alternating Pressure Profile Characteristics of Powered Pressure Ulcer Preventing Devices (동력형 욕창예방제품의 교대부양 압력 프로파 특성)

  • Won, Byeong-Hee;Song, Chang-Seop
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.639-646
    • /
    • 2010
  • The APAM's quantitative effectiveness and comparative study in preventing and treating pressure ulcer has not been sufficiently evaluated mainly because of uncertainty of pressure load input and lack of interpretation of dynamic perfusion recovery characteristics of soft tissue. The purpose of this paper was to quantify and analyze the alternating pressure characteristics of APAM as a preventive measure for pressure ulcers. To quantify the alternating load to human body, we introduced alternating pressure profile concept and developed parametric model of the profile. Regarding pressure level and cycle time, 3 global and 7 local periodic parameters were used to define the profile such as light, standard, typical and heavy duty profile shape. Pressure impulse ratio of light duty is the lowest but pressure fluctuation is significantly high. For the same duty shape, contact conditions are changed with alternating cycle time and more dramatically in shorter alternating cycle time conditions. We can conclude that if we use shorter alternating cycle time on APAM's operation we can get more positive effects regarding to inflated contact time condition. We proposed the quantitative methods on tissue viability study of external loading by simultaneous measurement of interface pressure and tissue perfusion with proper alternating pressure profile conditions.

A Study on the Characteristics of Fire Resistance of Window Material in Compartment Fire (건물화재시 창문재료에 따른 내화특성 연구)

  • Hur, Man-Sung;Jang, Moon-Seok;Cho, Soo
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.62-67
    • /
    • 2003
  • The full-scale compartment fire tests were carried out to evaluate the characteristics of fire resistance of window material under actual fire conditions. The room size used for full-scale room fire tests was 4 by 3.8 m with 2.4 m high ceiling. The windows with PVC, Aluminum and AL+Wood frame materials were established, sofa and mattress were used as fire sources. The window contained pair glasses with the air between 6 mm glasses. Temperatures at total 32 points in the room were measured to find the temperature distribution in the room fire. It is examined that thermal effects on window frame materials such as charring, distortion, melting, structural collapse, and other effects.

Electromagnetic Forces Measurement of Various Electric Appliances and Places (각종 전기기기 및 장소에서의 전자파 측정)

  • Kim, Deok-Won;Ryu, Chang-Yong;Kim, Su-Chan;Yoon, Hyung-Ro
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.179-182
    • /
    • 1995
  • Although air, water, and noise pollutions have been widely recognized, electromagnetic forces(EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, once machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven senates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

  • PDF

Effectiveness of Active Warming Intervention for Women Undergoing Cesarean Section: A Systematic Review and Meta-analysis (제왕절개 환자에서 적극적 가온 요법의 효과: 체계적 문헌고찰 및 메타분석)

  • Choi, Jung Eun;Kim, Mee Sun;Song, Jin Ran
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.24 no.3
    • /
    • pp.167-180
    • /
    • 2017
  • Purpose: The aim of this study was to synthesize the best available evidence for active warming interventions during cesarean section. Methods: A database search was done for randomized controlled trials utilizing active warming interventions. Maternal temperature, shivering and neonatal temperature were evaluated as outcome variables. Data were analyzed using Cochrane Review Manager software Version 5.3. Results: Thirteen studies including 1306 patients were reviewed. The degree of lowering of maternal temperature decreased in the warmed fluids (MD 0.51; p=.004) and warming mattress interventions (MD 0.22; p<.001) compared with control groups. Incidence of shivering was also lower in the active warming group (OR 0.55; p=.003). There was no statistically significant difference in maternal temperature with a forced air warming intervention (MD 0.64; p=.15) or in neonatal temperature (MD 0.12; p=.26). Conclusion: Findings show that with warmed fluids and warming mattresses applied during cesarean sections maternal temperature decline was reduced and also the incidence of shivering declined, but no significant effect was observed for forced air warming interventions. These findings provide a basis for developing a warming guideline for women having a cesarean section and will help to improve the quality of care for cesarean section patients.

The Effects of Alternating Set Pressure Changes on Dynamic Tissue Perfusion Characteristics (교대부양 설정압력 변화가 인체조직의 동적인 관류특성에 미치는 영향)

  • Won, Byeong-Hee;Song, Chang-Seop
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.875-887
    • /
    • 2010
  • The quantitative effectiveness of powered support surfaces such as APAM in preventing and treating pressure ulcers has not been sufficiently evaluated because of uncertainty of alternating pressure load input and lack of interpretation of dynamic perfusion characteristics of soft tissue. The aim was to verify the dynamic loading effects to sacral tissue perfusion characteristics from alternating set pressure changes. We developed integrated experiment system to supply alternating load to supinely positioned sacrum and concurrently measured $TcPO_2$, $TcPCO_2$ and air cell pressure. Ten aged subjects (5 female, 5 male) were tested with alternating set pressure 20, 30, 40, 50 and 60mmHg. From the dynamic perfusion response eight characteristic parameters were proposed such as average, minimum, maximum and perfusion range regarding to $TcPO_2$ and $TcPCO_2$. A one-way ANOVA was carried out to determine whether the manipulation of alternating set pressure had any effect on $TcPO_2$ and $TcPCO_2$. From the dynamic tissue perfusion response we found mean $TcPO_2$ decreased exponentially as alternating pressure load increased and perfusion range varied mainly because of minimum level change of $TcPO_2$. And perfusion range of $TcPCO_2$ affected by increase of maximum value of $TcPCO_2$. From the results we can get more strict insights about actual physiological dynamic tissue perfusion mechanism under alternating pressure load.

Exposure Assessments on Biological Contaminants in Homes of Allergy Patients - Bacteria, Fungi, House Dust Mite Allergen and Endotoxin (알레르기 환자 가정에서 생물학적 유해인자에 대한 노출평가 -세균, 진균, 집먼지 진드기 알레르겐, 내독소를 대상으로)

  • Moon Kyong Whan;Byeon Sang Hoon;Choi Dal Woong;Kim Young Whan;Lee Jang Hee;Lee Eun Il
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.2 s.83
    • /
    • pp.120-126
    • /
    • 2005
  • To assess exposure of allergy patients to a biological environment, measurements were made of levels of airborne bacteria and fungi, house dust endotoxin and mite allergens in homes of 7 allergy patients and 12 healthy families. Concentrations of airborne total bacteria and the ratio of indoor and outdoor concentrations(I/O) in allergy patient's homes were high compared to non-allergy houses. But no significant differences could be shown for the concentration of spores of viable fungi and staphylococcus in indoor air between the homes of allergic patients and healthy families. The results of investigation on house dust mites, Dermatophagoids farinae were detected in all mattress samples and the levels in the allergy patient's homes were generally high, with individual measurements exceeding $2{\mu}g/g$ dust found in $30\%$ samples. In contrast with, Dermatophagoids pteronyssinus were detected in only $60\%$ samples and the concentrations were very low. The levels of endotoxin in dust samples collected from the allergy patient's home mattresses were higher than those of control houses. There was a positive correlation between the endotoxin levels and the house dust mite allergens.

The Study of Realtime Fall Detection System with Accelerometer and Tilt Sensor (가속도센서와 기울기센서를 이용한 실시간 낙상 감지 시스템에 관한 연구)

  • Kim, Seong-Hyun;Park, Jin;Kim, Dong-Wook;Kim, Nam-Gyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.11
    • /
    • pp.1330-1338
    • /
    • 2011
  • Social activities of the elderly have been increasing as our society progresses toward an aging society. As their activities increase, so does the occurrence of falls that could lead to fractures. Falls are serious health hazards to the elderly. Therefore, development of a device that can detect fall accidents and prevent fracture is essential. In this study, we developed a portable fall detection system for the fracture prevention system of the elderly. The device is intended to detect a fall and activate a second device such as an air bag deployment system that can prevent fracture. The fall detection device contains a 3-axis acceleration sensor and two 2-axis tilt sensors. We measured acceleration and tilt angle of body during fall and activities of daily(ADL) living using the fall detection device that is attached on the subjects'. Moving mattress which is actuated by a pneumatic system was used in fall experiments and it could provide forced falls. Sensor data during fall and ADL were sent to computer and filtered with low-pass filter. The developed fall detection device was successful in detecting a fall about 0.1 second before a severe impact to occur and detecting the direction of the fall to provide enough time and information for the fracture preventive device to be activated. The fall detection device was also able to differentiate fall from ADL such as walking, sitting down, standing up, lying down, and running.

A study on the work in fishing convention, 2007 and the fishing vessel's accommodation facilities standards in national fishing vessel act (ILO어선원노동협약과 어선법의 어선거주설비에 대한 고찰)

  • Kim, Wook-Sung;Park, Moon-Gap
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.466-475
    • /
    • 2010
  • This study intends to present a direction for the better reforming of fishers'onboard living conditions and proposals for preparing for ratification of the Work in Fishing Convention by means of making a comparison between standards on recent national fishing vessel accommodation facilities and standards on the Work in Fishing Convention and Its Recommendation, 2007, ILO. For the most part of standards on national fishing vessel accommodation facilities are somewhat insufficient to satisfy the provisions in Annex III of the Convention. Considering by items on fishing vessel accommodation facilities, the standards on insect protector, noise and vibration, heating and air conditioning, lighting, persons per sleeping room, recreational facility are not provided in national law. Headroom, separation of accommodation, sleeping room floor area, mattress size, mess room, galley and food storage are partially sufficient for the Convention. In case of sanitary facilities, national standards are not sufficient for the Convention. The other side, facilities related safety of ship and crew such as emergency escape etc., are fully sufficient for the Convention. These insufficiencies caused by different types of fishing vessel depend on originality of fishing method and practices. In the comparison between equivalent tonnage about vessel's length on convention and calculated tonnage of national existing fishing vessel, the difference are 226tons about length 24m and 501tons about length 45m. For that reason, headroom, persons per sleeping room, cabin of sicker and injured, sanitary facilities may decide to use gross tonnage in place of length (L) and the alleviating measure basis of convention. But in case of standards on sanitary facilities which are unsufficient for the Convention, specially in coastal fishing vessel length basis should be adopted with alleviating basis for less than length 24m.

Human Exposures to Various Electromagnetic Forces : Measurement of Electromagnetic Force for Future Epidemiological Study (각종 전자파에 의한 인체의 노출 : 역학조사를 위한 전자파 측정)

  • Kim, Deok-Won;Ryu, Chang-Yong;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.191-200
    • /
    • 1995
  • Although air, water, and noise pollutions have been widely recognized, electromagnetic forces (EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, office machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven radiates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

  • PDF

Evaluation of a Tunneling Technique under the Latissimus Dorsi Muscle for Thoracostomy Tube Placement in Eleven Dogs (흉강 튜브 삽입을 위한 넓은 등근 아래 터널 만들기 방법에 대한 평가)

  • Yoon, Hun-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.368-371
    • /
    • 2012
  • The present study evaluated the outcome of use of thoracostomy tube tunneling technique under the latissimus dorsi muscle for the evacuation of postoperative pneumothorax induced by thoracotomy in 11 dogs. A stab incision was made through the skin and the latissimus dorsi muscle over the rib in the fifth intercostal space caudal to a surgical window. The thoracostomy tube with a Kelly hemostat was advanced into the thoracic cavity in a cranioventral direction through the sublatissimal tunnel. After tube placement, a # 1 nylon horizontal mattress suture was placed around the skin incision. The thoracostomy tube was removed after creating a negative pressure in the thoracic cavity. Dogs were monitored after surgery for pneumothorax, subcutaneous emphysema, clinical signs including dyspnea, and tube kinking in a muscle tunnel using physical examination and postoperative radiography. There was no tube kinking in the sublatissimal tunnel in 11 dogs on introducing the tubes into the thoracic cavity. The mean (${\pm}SD$) follow-up period was $19{\pm}10$ months. On postoperative radiography, there was no evidence of pneumothorax in 11 dogs. Subcutaneous emphysema was identified around the stab incision in a dog postoperatively. The subcutaneous emphysema disappeared spontaneously within 3 days. On postoperative physical examination, there was no evidence of dyspnea in 11 dogs. Our results suggest that the sublatissimal tunneling technique for thoracostomy tube placement is effective to prevent air leakage around the thoracostomy tube while the tube remains in the thoracic cavity and along the thoracostomy tunnel after tube removal. Tunneling under the latissimus dorsi muscle should be considered the thoracostomy tube placement technique to prevent iatrogenic pneumothorax with first priority.