• 제목/요약/키워드: Air mattress

검색결과 31건 처리시간 0.025초

동력형 욕창예방제품의 교대부양 압력 프로파 특성 (Alternating Pressure Profile Characteristics of Powered Pressure Ulcer Preventing Devices)

  • 원병희;송창섭
    • 대한인간공학회지
    • /
    • 제29권4호
    • /
    • pp.639-646
    • /
    • 2010
  • The APAM's quantitative effectiveness and comparative study in preventing and treating pressure ulcer has not been sufficiently evaluated mainly because of uncertainty of pressure load input and lack of interpretation of dynamic perfusion recovery characteristics of soft tissue. The purpose of this paper was to quantify and analyze the alternating pressure characteristics of APAM as a preventive measure for pressure ulcers. To quantify the alternating load to human body, we introduced alternating pressure profile concept and developed parametric model of the profile. Regarding pressure level and cycle time, 3 global and 7 local periodic parameters were used to define the profile such as light, standard, typical and heavy duty profile shape. Pressure impulse ratio of light duty is the lowest but pressure fluctuation is significantly high. For the same duty shape, contact conditions are changed with alternating cycle time and more dramatically in shorter alternating cycle time conditions. We can conclude that if we use shorter alternating cycle time on APAM's operation we can get more positive effects regarding to inflated contact time condition. We proposed the quantitative methods on tissue viability study of external loading by simultaneous measurement of interface pressure and tissue perfusion with proper alternating pressure profile conditions.

건물화재시 창문재료에 따른 내화특성 연구 (A Study on the Characteristics of Fire Resistance of Window Material in Compartment Fire)

  • 허만성;장문석;조수
    • 한국화재소방학회논문지
    • /
    • 제17권1호
    • /
    • pp.62-67
    • /
    • 2003
  • 실제 건물화재에서 창문재료의 내화특성을 평가하기 위하여 건물화재실험이 수행되었다. 4 mx3.8mx2.4m 방에서 PVC 창문, 알루미늄 창문, AL+Wood 창문을 각각 설치하고 화원은 소파와 매트리스를 사용하였다. 창문은 아파트 베란다에 많이 사용하는 유리두께 6mm사이에 공기층 12 mm인 것을 사용하였다. 건물내부와 창문 주변의 온도분포를 살펴보기 위하여 총 32개 지점의 온도를 측정하였다. 실험결과 건물내의 온도분포, 창틀의 변화, 유리창의 파손 정도 둥을 조사하여 분석하였다.

각종 전기기기 및 장소에서의 전자파 측정 (Electromagnetic Forces Measurement of Various Electric Appliances and Places)

  • 김덕원;류창용;김수찬;윤형로
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.179-182
    • /
    • 1995
  • Although air, water, and noise pollutions have been widely recognized, electromagnetic forces(EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, once machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven senates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

  • PDF

제왕절개 환자에서 적극적 가온 요법의 효과: 체계적 문헌고찰 및 메타분석 (Effectiveness of Active Warming Intervention for Women Undergoing Cesarean Section: A Systematic Review and Meta-analysis)

  • 최정은;김미선;송진란
    • 기본간호학회지
    • /
    • 제24권3호
    • /
    • pp.167-180
    • /
    • 2017
  • Purpose: The aim of this study was to synthesize the best available evidence for active warming interventions during cesarean section. Methods: A database search was done for randomized controlled trials utilizing active warming interventions. Maternal temperature, shivering and neonatal temperature were evaluated as outcome variables. Data were analyzed using Cochrane Review Manager software Version 5.3. Results: Thirteen studies including 1306 patients were reviewed. The degree of lowering of maternal temperature decreased in the warmed fluids (MD 0.51; p=.004) and warming mattress interventions (MD 0.22; p<.001) compared with control groups. Incidence of shivering was also lower in the active warming group (OR 0.55; p=.003). There was no statistically significant difference in maternal temperature with a forced air warming intervention (MD 0.64; p=.15) or in neonatal temperature (MD 0.12; p=.26). Conclusion: Findings show that with warmed fluids and warming mattresses applied during cesarean sections maternal temperature decline was reduced and also the incidence of shivering declined, but no significant effect was observed for forced air warming interventions. These findings provide a basis for developing a warming guideline for women having a cesarean section and will help to improve the quality of care for cesarean section patients.

교대부양 설정압력 변화가 인체조직의 동적인 관류특성에 미치는 영향 (The Effects of Alternating Set Pressure Changes on Dynamic Tissue Perfusion Characteristics)

  • 원병희;송창섭
    • 대한인간공학회지
    • /
    • 제29권6호
    • /
    • pp.875-887
    • /
    • 2010
  • The quantitative effectiveness of powered support surfaces such as APAM in preventing and treating pressure ulcers has not been sufficiently evaluated because of uncertainty of alternating pressure load input and lack of interpretation of dynamic perfusion characteristics of soft tissue. The aim was to verify the dynamic loading effects to sacral tissue perfusion characteristics from alternating set pressure changes. We developed integrated experiment system to supply alternating load to supinely positioned sacrum and concurrently measured $TcPO_2$, $TcPCO_2$ and air cell pressure. Ten aged subjects (5 female, 5 male) were tested with alternating set pressure 20, 30, 40, 50 and 60mmHg. From the dynamic perfusion response eight characteristic parameters were proposed such as average, minimum, maximum and perfusion range regarding to $TcPO_2$ and $TcPCO_2$. A one-way ANOVA was carried out to determine whether the manipulation of alternating set pressure had any effect on $TcPO_2$ and $TcPCO_2$. From the dynamic tissue perfusion response we found mean $TcPO_2$ decreased exponentially as alternating pressure load increased and perfusion range varied mainly because of minimum level change of $TcPO_2$. And perfusion range of $TcPCO_2$ affected by increase of maximum value of $TcPCO_2$. From the results we can get more strict insights about actual physiological dynamic tissue perfusion mechanism under alternating pressure load.

알레르기 환자 가정에서 생물학적 유해인자에 대한 노출평가 -세균, 진균, 집먼지 진드기 알레르겐, 내독소를 대상으로 (Exposure Assessments on Biological Contaminants in Homes of Allergy Patients - Bacteria, Fungi, House Dust Mite Allergen and Endotoxin)

  • 문경환;변상훈;최달웅;김영환;이장희;이은실
    • 한국환경보건학회지
    • /
    • 제31권2호
    • /
    • pp.120-126
    • /
    • 2005
  • To assess exposure of allergy patients to a biological environment, measurements were made of levels of airborne bacteria and fungi, house dust endotoxin and mite allergens in homes of 7 allergy patients and 12 healthy families. Concentrations of airborne total bacteria and the ratio of indoor and outdoor concentrations(I/O) in allergy patient's homes were high compared to non-allergy houses. But no significant differences could be shown for the concentration of spores of viable fungi and staphylococcus in indoor air between the homes of allergic patients and healthy families. The results of investigation on house dust mites, Dermatophagoids farinae were detected in all mattress samples and the levels in the allergy patient's homes were generally high, with individual measurements exceeding $2{\mu}g/g$ dust found in $30\%$ samples. In contrast with, Dermatophagoids pteronyssinus were detected in only $60\%$ samples and the concentrations were very low. The levels of endotoxin in dust samples collected from the allergy patient's home mattresses were higher than those of control houses. There was a positive correlation between the endotoxin levels and the house dust mite allergens.

가속도센서와 기울기센서를 이용한 실시간 낙상 감지 시스템에 관한 연구 (The Study of Realtime Fall Detection System with Accelerometer and Tilt Sensor)

  • 김성현;박진;김동욱;김남균
    • 한국정밀공학회지
    • /
    • 제28권11호
    • /
    • pp.1330-1338
    • /
    • 2011
  • Social activities of the elderly have been increasing as our society progresses toward an aging society. As their activities increase, so does the occurrence of falls that could lead to fractures. Falls are serious health hazards to the elderly. Therefore, development of a device that can detect fall accidents and prevent fracture is essential. In this study, we developed a portable fall detection system for the fracture prevention system of the elderly. The device is intended to detect a fall and activate a second device such as an air bag deployment system that can prevent fracture. The fall detection device contains a 3-axis acceleration sensor and two 2-axis tilt sensors. We measured acceleration and tilt angle of body during fall and activities of daily(ADL) living using the fall detection device that is attached on the subjects'. Moving mattress which is actuated by a pneumatic system was used in fall experiments and it could provide forced falls. Sensor data during fall and ADL were sent to computer and filtered with low-pass filter. The developed fall detection device was successful in detecting a fall about 0.1 second before a severe impact to occur and detecting the direction of the fall to provide enough time and information for the fracture preventive device to be activated. The fall detection device was also able to differentiate fall from ADL such as walking, sitting down, standing up, lying down, and running.

ILO어선원노동협약과 어선법의 어선거주설비에 대한 고찰 (A study on the work in fishing convention, 2007 and the fishing vessel's accommodation facilities standards in national fishing vessel act)

  • 김욱성;박문갑
    • 수산해양기술연구
    • /
    • 제46권4호
    • /
    • pp.466-475
    • /
    • 2010
  • This study intends to present a direction for the better reforming of fishers'onboard living conditions and proposals for preparing for ratification of the Work in Fishing Convention by means of making a comparison between standards on recent national fishing vessel accommodation facilities and standards on the Work in Fishing Convention and Its Recommendation, 2007, ILO. For the most part of standards on national fishing vessel accommodation facilities are somewhat insufficient to satisfy the provisions in Annex III of the Convention. Considering by items on fishing vessel accommodation facilities, the standards on insect protector, noise and vibration, heating and air conditioning, lighting, persons per sleeping room, recreational facility are not provided in national law. Headroom, separation of accommodation, sleeping room floor area, mattress size, mess room, galley and food storage are partially sufficient for the Convention. In case of sanitary facilities, national standards are not sufficient for the Convention. The other side, facilities related safety of ship and crew such as emergency escape etc., are fully sufficient for the Convention. These insufficiencies caused by different types of fishing vessel depend on originality of fishing method and practices. In the comparison between equivalent tonnage about vessel's length on convention and calculated tonnage of national existing fishing vessel, the difference are 226tons about length 24m and 501tons about length 45m. For that reason, headroom, persons per sleeping room, cabin of sicker and injured, sanitary facilities may decide to use gross tonnage in place of length (L) and the alleviating measure basis of convention. But in case of standards on sanitary facilities which are unsufficient for the Convention, specially in coastal fishing vessel length basis should be adopted with alleviating basis for less than length 24m.

각종 전자파에 의한 인체의 노출 : 역학조사를 위한 전자파 측정 (Human Exposures to Various Electromagnetic Forces : Measurement of Electromagnetic Force for Future Epidemiological Study)

  • 김덕원;류창용;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.191-200
    • /
    • 1995
  • 대기오염, 수질오염, 소음공해 등은 국내에서도 널리 알려지고 이에 대한 연구와 대책들이 수행되고 있으나 전자파 공해에 대한 인식은 국내에서는 매우 단편적이며 이에 대한 기초 연구조차 되어 있지 않아 국민 보건을 위해서 이 분야에 대한 연구가 시급한 실정이다. 그리하여 본 연구에서는 각종 가정용, 사무용 및 통신용 전기기기에서 발생하는 전자파를 측정하였고 또한 전철역 및 변전소 등에서와 같이 전자파가 많이 발생하는 장소에서도 측정하였다. 측정결과, 가정용 전기기기의 경우 전자레이니가 많은 양의 자계와 microwave를 방출하고 전기요의 경우에도 많은 양의 자계가 발생하였으며, 또한 청소년들이 많이 이용하는 전자오락실의 경우도 많은 자계가 발생하여 이에 대한 규제 및 대책이 시급한 것으로 나타났다. 요즈음 문제가 되고 있는 휴대용 전화기 및 car-phone의 경우도 위험하다고 추정되는 기준치에 비해 거의 십여배에 해당되는 micorwave가 검출되어 휴대용 전화기 및 car-phone의 사용자가 급격히 늘어가는 추세에 비추어 이에 대한 대책이 시급한 실정이다. 그리고 많은 시민들이 이용하는 지하철 및 지하철 역의 경우, 특히 국철 전돛차에서 많은 양의 자계가, 국철역에서는 많은 양의 자계 및 전계가 측정되었다. 본 연구에서는 각종 전기기기 및 장소에 따른 전자파를 측정하여서 data-base를 구축하였고 이를 통하여 앞으로의 역학 조사 및 연구에 발판을 마련하고자 한다.

  • PDF

흉강 튜브 삽입을 위한 넓은 등근 아래 터널 만들기 방법에 대한 평가 (Evaluation of a Tunneling Technique under the Latissimus Dorsi Muscle for Thoracostomy Tube Placement in Eleven Dogs)

  • 윤헌영;정순욱
    • 한국임상수의학회지
    • /
    • 제29권5호
    • /
    • pp.368-371
    • /
    • 2012
  • 본 연구는 개흉술을 실시한 11 마리 개에서 수술 후 흉강 내 음압 형성을 위한 흉강 튜브 삽입방법으로 넓은 등근 아래 흉강 튜브 삽입 방법의 효과를 평가하기 위해 실시 하였다. 흉강 튜브 삽입을 위해 수술 창 뒤쪽으로 다섯 번째 늑간 늑골 위 피부와 넓은 등근에 작은 절개창을 형성하였다. 지혈겸자를 장착한 흉강 튜브를 근육 아래 터널을 통과하여 흉강 내로 삽입하였으며 튜브 장착 후 절개창 주위에 매트리스 봉합법을 이용하여 봉합사를 설치하였다. 수술 후 흉강 내 음압을 형성한 다음 흉강 튜브를 제거하였다. 튜브 관련 부작용을 확인 하기 위해 튜브 삽입 시 튜브 꺽임 현상과 수술 후 신체 검사 및 방사선 검사를 통한 기흉, 피하 기종, 호흡곤란 여부를 확인 하였다. 튜브 삽입 시 튜브 꺽임 현상과 수술 후 기흉 및 호흡 곤란 증상이 11 마리 개 모두에서 확인 되지 않았다. 신체 검사에서 튜브 삽입 주위 피하 기종이 한 마리에서 관찰 되었으나 별다른 치료 없이 3일 후에 사라졌음을 확인 할 수 있었다. 음압 형성 후 평균 (${\pm}SD$) 추적 기간은 $19{\pm}10$ 개월 이었다. 결론적으로 넓은 등근 아래 흉강 튜브 삽입 방법은 튜브가 흉강 내 유지 될 때와 튜브 제거 후 남게 되는 터널을 통한 흉강 내 공기 유입 차단에 효과적이며 흉강 튜브 장착 시 우선적으로 고려 되야 할 방법으로 사료 된다.