Evaluation of Ventilation System Performance Using Indoor Air Quality Model (실내공기질 모델을 이용한 환기 시스템의 공기 정화 효율성 평가)

  • 최성우
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.57-66
    • /
    • 1997
  • Successful energy conservation and good indcfor air quality (IAQ) are highly dependent on ventilation system. Air filtration is a primary solution of indoor air control strategies in terms of reducing energy consumption and improving ihdoor air quality. A conventional system with bypass filter, as it is called variable-air-volume/bypass filtration system (VAV/BPFS), is a variation of the conventional variable air volume (VAV) systems, which is designed to eliminate indoor air pollutant and to save energy. Bypass filtration system equipped with a high-efficiency particulate filter and carbon absorbent provides additional cleaned air into indoor environments and maintain good IAQ for human health. The objectives of this research were to compare the relative total decay rate of indoor air pollutant concentrations, and to develop a mathematical model simulating the performance of VAV/BPFS. All experiments were performed in chamber under the controlled conditions. The specific conclusions of this research are: 1. The VAV/BPFS system is more efficient than the VAV system in removing indoor air pollutant concentration. The total decay rates of aerosol, and total volatile organic compound (TVOC) for the VAV/BPFS system were higher than those of the conventional VAV system. 2. IAQ model predictions of each pollutant agree closely with the measured values. 3. According to IAQ model evaluation, reduction of outdoor supply air results in decreased dilution removal rate and on increased bypass filtration removal rate with the VAV/BPFS. As a results, we recommends the VAV/BPFS as an alternative to conventional VAV systems.

  • PDF

A Study on the Application of VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) for Indoor Air Environment (VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) 의 실내환경 적응에 관한 연구)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1235-1243
    • /
    • 2003
  • Under controlled conditions in an environmental chamber, 24 experiments were performed to compare the ability of a Variable-Air-Volume/Bypass Filtration System(VAV/BPFS) to remove indoor pollutants and to conserve energy with the ability of conventional Variable Air Volume(VAV) system. The specific conclusions of this paper were; first, the VAV/BPFS was more efficient than the VAV system in removing particulate matter, TVOC, and target VOCs. The total effective removal rate of PM for the VAV/BPFS was two times as high as that of the VAV system. The total effective removal rate of TVOC for the VAV/BPFS was 20 percent higher than that of the VAV system. Also each target VOC concentration was reduced by using the VAV/BPFS. Second, clean air delivery rate was increased by using VAV/BPFS due to additional filtration rate. Otherwise, the VAV/BPFS decreased outdoor supply air rate above 25 percent relative to the rate of VAV system. Third, total energy consumption by the VAV/BPFS was lower than that of the VAV system during the period with indoor thermal load, occupied time. The energy saving of the VAV/BPFS ranged from 11 to 16 percent. The VAV/BPFS improves indoor air quality more efficiently than the VAV system, and it reduced energy consumption. Retrofitting the VAV system with the VAV/BPFS was easy The use of VAV/BPFS is, therefore, recommended far buildings with VAV system as well as for buildings at designing stage.

A preliminary study of Standardization Plan on Underground Air filtration Facility (지하역사 공기여과장치 표준화방안 사전연구)

  • Bae, Sung-Joon;Hwang, Sun-Ho;Shin, Chang-Hun
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.919-929
    • /
    • 2009
  • 2008, Seoulmetro transports an average of 3,952,000 passengers every day with a 0.8% increase of the daily ridership compared to last year.(Korean Economics '09.01.21) Seoul subway systems ridden by a considerable number of Seoul citizens place their top priority on swiftness, safety and clean underground air quality so as to meet the customer satisfaction. One of the most important problems is to eliminate minute dust(PM10) among the pollutants such as the gas attributable to air pollution and floating particulate matter defined by the ordinance of the Ministry of Environment. Seoulmetro install and operate many kinds of air filtration facilities, however we've launched a research on "Standardization Plan on Underground Air Filtration Facility" for the installation and improvement of optimum standardized air filtration system. As a preliminary study, we're going to consider ventilation system and air filter to supply filtered metropolitan outdoor air aimed at ensuring clean underground environment.

  • PDF

Performance of the Exhaust Filtration System of Hot Cell at PIEF (조사후시험시설에서의 핫셀 배기포집시스템의 성능평가)

  • Hwang, Yong-Hwa
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.799-804
    • /
    • 2011
  • Radioactivity of high concentrations have existed in the handling nuclear materials in hot cell of PIEF(Post Irradiation Examination Facility). The exhaust filtration system was enabled to process cylindrical filters by using a manipulator in the hot cell. By establishing a double filtration system with two filters, backup protection against leakage or failure of the first is provided by the second filter. Additionally, this a arrangement is arrange intended to increase the total filtration efficiency. The result of the pressure drop changing in the air flow of the cylindrical and HEPA filters is observed by a curved line. A filtering efficiency of more than 99.99% to $0.3{\mu}m$ particle appears in the upstream and downstream during the efficiency test on the HEPA filters. The V-pleats type had a lower pressure drop than the separator type. There was no damage during usage and was found to be suitable with high capacity of air volume. Therefore, by carrying out performance tests of the exhaust filtration system, efficiency and safety can be achieved.

Development of Optimal Antiviral Coating Method for the Air Filtration System of Subway Station (지하역사 승강장 공조 시스템 필터용 항바이러스 코팅 성능 및 재생 성능 평가)

  • Park, Dae Hoon;Hwang, Jungho;Shin, Dongho;Kim, Younghun;Lee, Gunhee;Park, Inyong;Kim, Sang Bok;Hong, Keejung;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.18 no.1
    • /
    • pp.9-21
    • /
    • 2022
  • In this study, a novel antiviral coating method for the air filtration system of subway station was investigated. Using dry aerosol coating process, we developed a high-performance antiviral air filter with spark discharger and carbon brush type ionizer. Silver nanoparticles were produced by a spark discharge generation system with ion injection system and were used as antiviral agents coated onto a medium grade air filter. The pressure drop, filtration efficiency, and antiviral ability of the filter against aerosolized MS2 virus particles as a surrogate of SARS-CoV-2 virus were tested with dust contamination. Dust contamination caused the increase of the filtration efficiency and pressure drop, while the antiviral agents (in this study, silver nanoparticles) coating did not have any significant effect on the filtration efficiency and pressure drop. Using these properties, we suggested a novel method to maximize the antiviral performance of the antiviral air filter that was contaminated by dust particles. Moreover theoretical analysis of antiviral ability with dust contamination and re-coated antiviral agents was carried out using a mathematical model to calculate the time-dependent antiviral effect of the filter under actual conditions of subway station. Our model can be used to apply on antiviral air filtration system of subway station for prevention of pandemic diffusion, and predict the life cycle of an antiviral filter.

An Experiment on Performance Evaluation of a Vapor Condensation Type Air Washer System for Semiconductor Clean Rooms (반도체 클린룸용 수증기 응축식 에어와셔 시스템의 성능평가)

  • Yeo, Kuk-Hyun;Park, Sang-Tae;Yoo, Kyung-Hoon;Son, Seung-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.442-447
    • /
    • 2006
  • In semiconductor manufacturing clean rooms, it becomes important to remove airborne molecular contaminants as well as particulate contaminant in outdoor air introduced into clean rooms. One suitable control technique for these chemical contaminants is air washing by water in an outdoor air handling unit. In order to enhance the removal efficiency of chemical contaminants the effect of adding a heating and humidifying process before an air washer was examined.

  • PDF

High-rate Removal of Algae by Using of Filtration System with Coagulant Addition (응집과 여과를 이용한 조류의 초고속 제어에 관한 연구)

  • Yun, Sang Leen;Kim, Dong Ha;Rhee, Young Kyu
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.221-228
    • /
    • 2002
  • Abundant growth of algae in raw water sources caused by eutrophication brings about significant side effects on water supply, such as taste and order problem, oxygen depletion, toxic material secretion, and filter clogging problem in water treatment process, etc. The purpose of this research is to remove the algae and phosphorus compounds in the Pal-dang reservoir promptly by using the upflow filtration system with coagulant addition. The filter tower consisted of sand media and sieve filter with air back-washing process. By using coagulation and filtration with $132{\mu}m$ pore size filter, about 55% and 70% of algae and phosphorus compounds were removed respectively. The experimental conditions were as follows; head loss of 0.2m, linear velocity of 200m/day, and filtration flux of 1000($L/m^2/day$). In the case of filtration with cartridge type filter of $25{\mu}m$ pore size, the filtration flux was about 7800 LMH, and the removal ratios of COD, SS, T-P, and Chlo-a. were 61%, 99%, 54%, and 98%, respectively. However, high pressure air back-washing process with should be required for the maintenance of such high filtration flux.