• Title/Summary/Keyword: Air conditioner control

Search Result 182, Processing Time 0.029 seconds

Comparison of Thermal Comfort Performance Indices for Cooling Loads in the Lecture Room - An Correlation of PMV Bnd EDT - (강의실에서의 냉방부하에 따른 열쾌적성 평가지표 비교 - PMV와 EDT의 연관성 -)

  • Noh Kwang-Chul;Oh Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.868-877
    • /
    • 2005
  • We performed the experimental and the numerical study on the comparison of thermal comfort performance indices for cooling loads in the lecture room for 4 cases: Fan coil unit(FCU) or 4-way cassette air-conditioner is respectively operated with the ventilation system or without. We measured the velocity, the temperature distribution and predicted mean vote(PMV) value in the lecture room for 4 different air-conditioning methods. Effective draft temperature(EDT) and PMV were investigated to analyze the characteristics of two thermal comfort indices in the lecture room and to compare their values each other. From the results we knew that there is the similarity between PMV values and EDTs when the room is air-conditioned for cooling loads. It turned out that definition of the control temperature is very important when the EDT is calculated. Finally EDT should not be used to predict the accurate thermal comfort in case that the temperature and humidity are suddenly varied and the zone affected by the solar and inner wall radiation.

(On designing Temperature Control System of the Air-conditioner using immune system) (면역 시스템을 이용한 에어콘의 온도 제어 시스템 설계)

  • Seo, Jae-Yong;Jo, Hyeon-Chan;Jeon, Hong-Tae
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • In this paper, we propose temperature inference system for indoor and outdoor temperature of the Air-Conditioner with limited sensors. The proposed system based on the network theory of biological immune system consists of indoor and outdoor temperature inference process. It is designed that on-line temperature inference is possible. This system is admirable for unlearned data as well as given input data by making efficient use of previous information.

SINGLE-PHASE ACTIVE RECTIFIER WITH HIGH POWER FACTOR CAPABILITY FOR INVERTER AIR-CONDITIONER

  • Jung, Yong-Chae;Kwon, Kyung-Ahn
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.677-682
    • /
    • 1998
  • A Single-phase Active Rectifier (SAR) [4-6] with high power factor capability is adopted to satisfy the international harmonic current standards such as IEC 1000-3-2. To minimize the input current distortion and to apply the control IC, such as FA5331, UC3854, ML4821 and so forth, the new adequate sensing circuits of the input voltage and current are proposed. There are tow methods applicable the SAR to inverter air-conditioner from the viewpoint of both efficiency and cost. The selecting methods of the passive components are presented for the two approaches. Using the determined components, the loss analyses are carried out. The prototype SAR circuits of these two approaches with 3kW power consumption are built and the operation and performance of the circuits with power factor correction capability are verified through the experimental results.

  • PDF

Process Design to Prevent Internal & External Defects of Cold Extruded Products with Double Ribs (이중 리브를 가진 냉간 압출품의 내.외부 결함 방지를 위한 공정 설계)

  • 김동진;김병민
    • Transactions of Materials Processing
    • /
    • v.8 no.6
    • /
    • pp.612-619
    • /
    • 1999
  • Internal and external defects of an inner pulley for automobile air conditioner are investigated in this study. Inner pulley is a part of compressor clutch assembly of automobile air conditioner. In cold forging of inner pulley, the design requirement are to keep the same height of the inner rib and outer one and to make uniform distribution of hardness in the forged product. At the end of the forging of inner pulley, the piping defect as an external defect begins to form at the back center of the billet. The internal crack as an internal defect also occur at the adiabatic shear band which usually has maximum ductile fracture value. It is important to predict when the internal and external defects occur during the deformation process, in order to minimize the amount of discard that is generated. The finite element simulations are applied to analyze the defects. The validity of the computational results are examined by experiments. These computational results are in good agreement with the experimental ones.

  • PDF

A Study on Control and Monitoring System for Building Energy Management System

  • Oh, Jin-Seok;Bae, Soo-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.335-340
    • /
    • 2011
  • Building energy saving is one of the most important issues in these days. Control algorithm for energy saving should be designed properly to reduce power consumption in building. Recently, building energy system consists of hybrid energy system coupling with RE (Renewable Energy) source. In this paper, an optimum control algorithm for building energy saving is applied to BEMS (Building Energy Management System) by using an outdoor air temperature prediction strategy. BEMS coupling with renewable energy can control HVAC (Heating, Ventilating and Air-Conditioning) system effectively. In order to verify the effectiveness of building energy saving, BEMS was tested for several months at a laboratorial chamber with an air conditioner, fan and heater. To this end BEMS embedded control algorithm has been tested successfully.

New control strategy of Static Inverter for the Light Rail Transit (경량전철용 보조전원장치의 새로운 제어 기법)

  • Lee, Eun-Kyu;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.190-193
    • /
    • 2003
  • This paper Proposes 40 [KVA] rated SIV(Static Inverter) system for Light Rail Transit. The SIV Provide power of a fluorescent light in the car, Air-conditioner. and other equipments. To control output voltage it is used voltage control loop for constant voltage control and simultaneously used current control loop for instantaneous control at load changing. The Performance of SIV system will be verified by experimental results.

  • PDF

Development of Static Inverter for the Light Rail Transit (경량전철용 보조전원장치의 개발)

  • 이은규;염상구;최재호
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.522-527
    • /
    • 2002
  • This paper proposes 40 [KVA] rated SW(Static Inverter) system for Light Rail Transit. The SIV provide power of a fluorescent light in the car, Air-conditioner, and other equipments. To control output voltage it is used voltage control loop for constant voltage control and simultaneously used current control loop for instantaneous control at load changing. The performance of SW system will be verified by experimental results.

  • PDF

Energy Saving Potentials of Dedicated Outdoor Air System in a High-rise Apartment Building (외기전담 시스템 기반 초고층 공동주택 중앙 환기시스템의 에너지 절감효과 분석)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.291-296
    • /
    • 2009
  • This paper investigates the energy saving potentials of a dedicated outdoor air system (DOAS) applied to a highrise apartment building. As for a typical $132-m^2$ apartment unit, two different HVAC systems; centralized DOAS-Ceiling Radiant Cooling Panel and decentralized Energy Recovery Ventilator-Packaged Air Conditioner were installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program, and annual cooling coil load and heating load reduction potentials were compared. The research shows that DOAS-Ceiling Radiant Cooling Panel system can reduce the cooling coil load over 21% annually compared with the current Energy Recovery Ventilator-Packaged Air Conditioner pair. In addition, over 40% of annual ventilation heating load can be reduced by use of DOAS.

  • PDF

Economic Analysis and Comparison between Hybrid and Central Air Conditioning System (혼합공조와 중앙공조 시스템의 경제성 분석 및 비교)

  • Lee, Yoon-Jong;Kim, Chan-Jung;Moon, Je-Myung;Kim, Cheol-Woo;Seo, Hyeong-Joon;Kim, Gyoung-Rok;Shin, Haeng-Cho;Hong, Hi-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.334-339
    • /
    • 2007
  • This paper is concerned with economic analysis and comparison between hybrid and central air conditioning system by TRNSYS simulation and Life Cycle Cost(LCC) analysis. Hybrid air conditioning system that is using VAV for interior zone and system air-conditioner for perimeter zone is installed in building A. Central air conditioning system is composed of VAV and convector. The simulation was carried out in mode temperature level control using TRNSYS 16. From the result of simulation and LCC analysis, hybrid air conditioning system was better than central air conditioning system in initial cost and energy consumption.

  • PDF

Analysis of Flow Distribution around Room Air Conditioner Using PIV Technique (PIV기법을 이용한 룸에어컨 주변 유동 분포 해석)

  • Lee, A-Mi;Han, Kyu-Il;Kim, Dong-Won;Na, Seon-Uk;Joo, Jae-Man;Ko, Han-Seo
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.131-134
    • /
    • 2006
  • Whole flow fields of a room air conditioner (RAC) have been visualized by a Particle Image Velocimetry (PIV) technique to analyze the flow structure by various inlet and outlet angles, and to control an eccentric vortex which affects an efficiency and noise of the RAC. A test model with 5 stages of a cross flow fan has been manufactured and a transparent acryl has been installed at the side of the test model for the PIV experiment. The inlet and outlet flows and the flow inside the cross flow fan have been analyzed by varying the inlet grill angles and outlet blade angles. The movement of the eccentric vortex has been investigated experimentally by developing the measurement technique for the inner flow field of the cross flow fan, and the relationship between the control of the eccentric vortex and the inlet and outlet angles has been confirmed in this study.

  • PDF