• Title/Summary/Keyword: Air clean system

Search Result 289, Processing Time 0.028 seconds

Numerical Study on the Performance Assessment for Defrost and De-Icing Modes (승용차의 제상 및 성에 제거 성능 평가를 위한 수치해석적 연구)

  • Kim, Yoon-Kee;Yang, Jang-Sik;Kim, Kyung-Chun;Ji, Ho-Seong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.161-168
    • /
    • 2011
  • The heating, ventilating, air conditioning (HVAC) system is a very important part of an automotive vehicle: it controls the microclimate inside the passenger's compartment and removes the frost or mist that is produced in cold/rainy weather. In this study, the numerical analysis of the defrost duct in an HVAC system and the de-icing pattern is carried out using commercial CFX-code. The mass flow distribution and flow structure at the outlet of the defrost duct satisfied the duct design specification. For analyzing the de-icing pattern, additional grid generation of solid domain of ice and glass is pre-defined for conductive heat transfer. The flow structure near the windshield, streakline, and temperature fields clearly indicate that the de-icing capacity of the given defrost duct configuration is excellent and that it can be operated in a stable manner. In this paper, the unsteady changes in temperature, water volume fraction, and static enthalpy at four monitoring points are discussed.

The Effect of the Performance of Firefighting Construction Supervision Personnel on the Completion Inspection of Firefighting Facility Construction in Apartments (소방공사감리원의 업무수행능력이 아파트 소방시설공사의 완공검사에 미치는 영향)

  • Kim, Sang-Sig;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.43-54
    • /
    • 2019
  • In this study, results of completion inspection are investigated according to the performance of the firefighting construction supervision personnel and according to the necessity of clean air supply in a performance test of the firefighting construction supervision personnel. The results of the completion inspection are measured and the causes of defects in the fire protection facilities after issuance of a completion inspection certificate are analyzed. The findings of this investigation can be used to minimize the risk of apartment fires and improve the performance of firefighting construction supervision personnel. The results of this study are summarized as follows. First, the results of the completion inspection conducted by the firefighting construction supervision personnel varies according to particular occupation. The performance of fire facility supervisors from design companies and fire construction companies were significantly higher than the fire officers. Therefore, it is necessary to employ supervisors who have experience in supervising the construction of apartments, in order to improve the performance of fire construction supervision officers. Second, the analysis of the completion inspection results according to the necessity of a clean air supply for performance tests of firefighting construction supervision personnel showed that the necessity of a clean air supply was significantly higher for fire facility supervisors from design companies and fire construction companies than for the fire officers. In order to improve, the completion inspection should be carried out up until the completion date of the building. In addition, a system needs to be established to ensure that clients are not able to demand that a completion inspection certificate be issued on the construction completion date. Finally, it is found that defects of completion inspection after issuance of a completion inspection certificate affects the result of the completion inspection. The results of the completion inspections conducted by the fire facility supervisors from design companies and fire construction companies were affected significantly less by defects than that of the general contractors. Research shows that faults have occured in firefighting facilities after the issuance of a completion inspection certificate due to the client and the construction company demanding the issuance of the completion inspection certificate.

An Experimental Study on Real Time CO Concentration Measurement of Combustion Gas in LPG/Air Flame Using TDLAS (TDLAS를 이용한 LPG/공기 화염 연소가스의 실시간 CO 농도 측정에 관한 연구)

  • So, Sunghyun;Park, Daegeun;Park, Jiyeon;Song, Aran;Jeong, Nakwon;Yoo, Miyeon;Hwang, Jungho;Lee, Changyeop
    • Clean Technology
    • /
    • v.25 no.4
    • /
    • pp.316-323
    • /
    • 2019
  • In order to enhance combustion efficiency and reduce atmosphere pollutants, it is essential to measure carbon monoxide (CO) concentration precisely in combustion exhaust. CO is the important gas species regarding pollutant emission and incomplete combustion because it can trade off with NOx and increase rapidly when incomplete combustion occurs. In the case of a steel annealing system, CO is generated intentionally to maintain the deoxidation atmosphere. However, it is difficult to measure the CO concentration in a combustion environment in real-time, because of unsteady combustion reactions and harsh environment. Tunable Diode Laser Absorption Spectroscopy (TDLAS), which is an optical measurement method, is highly attractive for measuring the concentration of certain gas species, temperature, velocity, and pressure in a combustion environment. TDLAS has several advantages such as sensitive, non-invasive, and fast response, and in-situ measurement capability. In this study, a combustion system is designed to control the equivalence ratio. Also, the combustion exhaust gases are produced in a Liquefied Petroleum Gas (LPG)/air flame. Measurement of CO concentration according to the change of equivalence ratio is confirmed through TDLAS method and compared with the simulation based on Voigt function. In order to measure the CO concentration without interference from other combustion products, a near-infrared laser at 4300.6 cm-1 was selected.

Evaluation of Commercially Available Passive Samplers and Development of New Passive Samplers Part 1: Evaluation of Commercially Available Passive Samplers (공기중 유기용제 농도 측정에 있어서 수동식 시료채취기의 성능평가 및 한국산 수동식 시료채취기의 개발에 관한 연구 제 1 부 : 외국산 수동식 시료채취기의 성능 평가)

  • Paik, Nam Won;Park, Mi Jin;Yoon, Chung Sik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.109-124
    • /
    • 1996
  • This study was performed to evaluate the performance of three passive samplers made in U.S.A. Three passive samplers selected for this study included products made by 3M, Gilian, and SKC in U.S.A. Three organic solvents, such as toluene, trichloroethylene, and n-hexane which are used frequently in Korean industry were selected for the study. Conclusions obtained from this study are summarized as follows. 1. For toluene and trichloroethylene, the overall accuracy of the results from all of three products was within 25 %, which is the criteria recommended by the U.S. National Institute for Occupational Safety and Health (NIOSH). For n-hexane, the overall accuracy of the results from two products except 3M was exceeding 25 %. Thus 3M product showed the best accuracy among three products. 2. When passive samplers collected organic vapors were exposed to clean air for two hours, there were 12 - 16 % loss of organic vapors due to reverse diffusion in Gilian products. There was no significant loss in results from other two products. 3. Air velocity affected greatly on the performance of passive samplers which did not have permeation membrane. At high velocity, 100 cm/sec, accuracies of results from Gilian and SKC were 57 - 108 and 128 - 164 %, respectively. However, the results from 3M samplers, which contain permeation membrane, indicated accuracy below 25 %. 4. When passive samplers collected organic vapors for eight hours, the accuracy was reduced. Thus, it is recommended that passive samplers be used for less than four hours.

  • PDF

Ozone Simulations over the Seoul Metropolitan Area for a 2007 June Episode, Part I: Evaluating Volatile Organic Compounds Emissions Speciated for the SAPRC99 Chemical Mechanism (2007년 6월 수도권 오존모사 I - 광화학측정자료를 이용한 SAPRC99 화학종별 휘발성유기물질 배출량 입력자료 평가)

  • Kim, Soon-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.580-602
    • /
    • 2011
  • Volatile organic compound (VOC) emissions in the 2007 CAPSS (Clean Air Protection Supporting System) emissions inventory are chemically speciated for the SAPRC99 (Statewide Air Pollution Research Center 99) mechanism, following the Source Classification Code (SCC) matching method to borrow the U.S.EPA's chemical speciation profiles. CMAQ simulations with High-order Direct Decoupled Method (HDDM) are in turn applied to evaluate uncertainty in the method by comparing the simulated model VOC species to the observations in the Seoul Metropolitan Area (SMA) for a 2007 June episode. Simulations under-predicted ALK1 to ALK4 in SAPRC99 by a factor of 2 to 5 and over-predicted ALK5 by a factor of 7.5 while ARO1, ARO2, OLE1, and ethylene (ETH) are comparable to the observations, showing relative difference by 10 to 30%. OLE2 emissions are roughly 4 times overestimated. Emission rates for individual VOC model species are revised referring to the ratio of simulated to observed concentrations. Impact of the VOC emission changes on the overall ozone prediction was insignificant for the days of which 1-hr maximum ozone are lower than 100 ppb. However, simulations showed ozone difference by 5 to 10 ppb when high ozone above 120 ppb was observed in the vicinity of Seoul. This result suggests that evaluations on individual model VOC emissions be necessary to lead ozone control plans to the right direction. Moreover, the simulated ratios of ARO1 and ARO2 to $NO_x$ are roughly 50% lower than the observed ones, which imply that adjustment in $NO_x$ and VOC emission rates may be required to mimic the real VOC/$NO_x$ condition over the area.

An Experimental Study on the Spray and Lean Combustion Characteristics of Bio-enthanol-Gasoline Blended Fuel of GDI (직접분사식 바이오에탄올-가솔린 혼합연료의 분무 및 희박연소 특성에 관한 실험적 연구)

  • Park, Gi-Young;Kang, Seok-Ho;Kim, In-Gu;Lim, Cheol-Soo;Kim, Jae-Man;Cho, Yong-Seok;Lee, Seong-Wock
    • Journal of ILASS-Korea
    • /
    • v.19 no.3
    • /
    • pp.115-122
    • /
    • 2014
  • As a demand for an automobile increases, air pollution and a problem of the energy resources come to the fore in the world. Consequently, governments of every country established ordinances for green-house gas reduction and improvement of air pollution problem. Especially, as international oil price increases, engine using clean energy are being developed competitively with alternative transportation energy sources development policy as the center. Bio ethanol, one of the renewable energy produced from biomass, gained spotlight for transportation energy sources. Studies are in progress to improve fuel supply methods and combustion methods which are key features, one of the engine technologies. DI(Direct Injection), which can reduce fuel consumption rate by injecting fuel directly into the cylinder, is being studied for Green-house gas reduction and fuel economy enhancement at SI(Spark Ignition). GDI(Galoine Direct Injection) has an advantage to meet the regulations for fuel efficiency and $CO_2$ emissions. However it produces increased number of ultrafine particles, that yet received attention in the existing port-injection system, and NOX. As fuel is injected into the cylinder with high-pressure, a proper injection strategy is required by characteristics of a fuel. Especially, when alcohol type fuel is considered. In this study, we tried to get a base data bio-ethanol mixture in GDI, and combustion for optimization. We set fuel mixture rate and fuel injection pressure as parameters and took a picture with a high speed camera after gasoline-ethanol mixture fuel was injected into a constant volume combustion chamber. We figured out spraying characteristic according to parameters. Also, we determine combustion characteristics by measuring emissions and analyzing combustion.

Environmental Policy Comparison under Various Potential Forms of Health Response Function (건강반응함수를 고려한 환경정책의 비교)

  • Hlasny, Vladimir
    • Environmental and Resource Economics Review
    • /
    • v.19 no.4
    • /
    • pp.915-961
    • /
    • 2010
  • This study is concerned with health damages from $SO_2$ under different assumptions on the relationship between air concentrations and their marginal health impacts. $SO_2$ concentration profiles resulting under emission caps, and a system of tradable emission allowances are compared. Using slopes and curvatures of the health response function consistent with evidence in medical literature, emission caps are shown to lead to lower aggregate damages under all considered parameters, an advantage of $26~452 million. The benefit of emission caps over tradable allowances increases with the curvature of the response function, but falls with its slope. The advantage of emission caps in terms of environmental damages is never overturned completely for the considered functional forms. The marginal damage function would have to be steeper than what the current medical evidence suggests for price instruments to outperform emission caps in terms of aggregate damages. With other welfare consequences included-emission abatement costs, consumer and producer surpluses, and government revenue-emission caps always lead to a $3.7~4.1 billion greater measure of social welfare.

  • PDF

Research on Step-Type Chemical Liquid Deodorizer using Liquid Catalyst

  • WOO, Hyun-Jin;KWON, Lee-Seung;JUNG, Min-Jae;YEO, Og-Gyu;KIM, Young-Do;KWON, Woo-Taeg
    • The Korean Journal of Food & Health Convergence
    • /
    • v.6 no.5
    • /
    • pp.19-25
    • /
    • 2020
  • The purpose of this study was to research and develop a step-type chemical liquid deodorizer including a liquid catalyst that can prevent civil complaints due to odor due to its excellent deodorizing performance. The main composition of chemical liquid deodorizer including liquid catalyst is cleaning deodorization, catalyst deodorization, chemical deodorization, water film plate, deodorization water circulation device, deodorization water injection device, catalyst management system, gas-liquid separation device, chemical supply device, deodorizer control panel, etc. It consists of a device. The air flow of the step-type liquid catalyst chemical liquid deodorizer is a technology that firstly removes basic odor substances, and the liquid catalyst installed in the subsequent process stably removes sulfur compounds, which are acidic odor substances, to discharge clean air. The efficiency of treating the complex odor of the prototype was 98.5% for the first and 99.6% for the second, achieving the target of 95%. The hydrogen sulfide treatment efficiency of the prototype was 100% for the first and 99.9% for the second, which achieved 95%, which was the target of the project. As a result, ammonia was removed by the reaction of ammonia and hydrogen sulfide.

Investigation and Analysis of Particulate-matters and Ammonia Concentrations in Mechanically Ventilated Broiler House According to Seasonal Change, Measurement Locations and Age of Broilers (강제환기식 육계 사육시설의 계절별, 지점별, 주령별 PM, NH3 농도 조사 및 분석)

  • Jang, Dong-hwa;Kwon, Kyeong-seok;Kim, Jong-bok;Kim, Jung-kon;Yang, Ka-young;Choi, Sung-min;Jang, YuNa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.75-87
    • /
    • 2021
  • Air quality related to particulate matters and ammonia is being come to the fore as the national concern in Korea. CAPSS (Clean Air Policy Support System) provides emission coefficients of these kinds of particulate and gaseous matters in the fields of livestock; however reliability issues are consistently mentioned. Evaluation of emission rates of PM2.5 and NH3 of the country is very important, but only few studies are available as the background related to observation of the concentration of the particulate matter and ammonia, especially within livestock house in Korea. In this paper, long-term measurement of PM10, PM2.5, and ammonia within the mechanically ventilated broiler house were carried out to introduce backgrounds of generation and emission of the particulate matters and ammonia. Measurement results were analyzed according to seasonal changes, age of broilers(weeks) and measurement locations. Concentration of inhalable and respirable dust were also evaluated in terms of occupational respiratory health according to increase in broiler's activity. From the results of this study, identification of the generation mechanisms of the particulate and gaseous matters, and evaluation of the emission rate of these in the broiler house will be carried out.

Utilization of Element-doping Titania-impregnated Granular Activated Carbon in a Plug-flow System for Removal of BTEX

  • Jo, Wan-Kuen;Shin, Seung-Ho;Hwang, Eun-Song;Yang, Sung-Bong
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.3
    • /
    • pp.177-188
    • /
    • 2010
  • The use of an activated carbon (AC) system alone has the limitation that the pollutants are not eliminated but only transferred to another phase with the consumed AC becoming hazardous waste itself. Therefore, the present study investigated the feasibility of using a combined system of granular AC (GAC) with S-doped visible-light-induced $TiO_2$ (GAC/S-doped $TiO_2$) to clean monocyclic aromatic hydrocarbons (MAHs) with concentrations at $\leq$ 3 mg $m^{-3}$, using a continuous air-flow reactor. This study conducted three different experiments: an adsorption test of pure GAC and GAC/S-doped $TiO_2$; a long-term adsorptional photocatalytic (AP) activity test of GAC/S-doped $TiO_2$; and an AP activity test of GAC/S-doped $TiO_2$ under different conditions. For the AP activity test, three parameters were evaluated: various weights of GAC/S-doped $TiO_2$ (0.9, 4.4, and 8.9 g); various flow rates (FRs) (0.5, 1 and 2 L $min^{-1}$); and various input concentrations (ICs) of the target MAHs (0.1, 1, 2 and 3 mg $m^{-3}$). The adsorption efficiencies were similar for the pure GAC and GAC/S-doped $TiO_2$ reactors, suggesting that S-doped $TiO_2$ particles on GAC surfaces do not significantly interfere with the adsorption capacity of GAC. Benzene exhibited a clear AP activity, whereas no other target MAHs did. In most cases, the AP efficiencies for the target MAHs did not significantly vary with an increase in weight, thereby suggesting that, under the weight range tested in this study, the weights or FRs are not important parameters for AP efficiency. However, ICs did influence the AP efficiencies.