• 제목/요약/키워드: Air breakdown

검색결과 234건 처리시간 0.029초

Electrical Breakdown In flames

  • Uhm, Han S.
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제4권1호
    • /
    • pp.33-37
    • /
    • 2000
  • Properties of electrical discharge in flames and influence of plasma electrons on gas neutrals are investigated by making use of the ionization cross section of air. Frames have three distinctive features. They are hot, emit light and are weakly ionized. We investigate influence of these three characteristics of flames on the electrical breakdown. It is found that the breakdown electric field in flames is inversely proportional to the flame temperature T$\_$g/, thereby easily generating plasmas in flames. A swarm of low-energy electrons in flames would allow a significant population of electronically excited states of flame molecules to be formed. Therefore, the analysis shows that the electronic excitation of flame molecules may also considerably reduce the breakdown field. Plasma electrons generate atomic oxygen by the electron attachment of oxygen molecules in high-pressure flames. These oxygen atoms are the most reactive radicals in flames for material oxidation.

  • PDF

진공에서 전극 재질에 따른 절연파괴 전압 특성 파악 (characteristic of breakdown voltage of electrode material in vacuum)

  • 이승수;허준;윤재훈;임기조;강성화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.101-102
    • /
    • 2008
  • SF6 widely used as insulating gas is rising as the environment problem. For decreasing this greenhouse gas, electrical breakdown characteristics of vacuum with air are studied in non-uniform field. The gap of needle to plane was 0.5mm. The pressure of vacuum the range of 10^-4${\sim}$10^-5torr. The diameter of a plane made of the stainless steel is 150mm. As a result of the experiment, the breakdown voltage is increased about degree of vacuum increased. The electrode material influenced breakdown voltage in vacuum.

  • PDF

기계적 응력상태에서 절연지 및 케이블의 전기절연 특성 (The Characteristics of Electrical Breakdown of Dielectric Paper and Cable under mechanical stress)

  • 김영석;곽동순;김해종;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 영호남 학술대회 논문집
    • /
    • pp.3-6
    • /
    • 2003
  • The electrical and mechanical properties of dielectric paper and cable at cryogenic temperature have been investigated to optimum insulating design of high-Tc superconducting(HTS) cable. From the results, Tensile strength of PPLP in liquid nitrogen was high more than that of air, but tensile strain could know that decrease sharply. According as tensile strength increases, the breakdown stress of PPLP in liquid nitrogen was decreased because PPLP was degradated. According as bending radius multiple is decrese, breakdown voltage decreased sharply. And bending radius multiple is thought that more than about 25 is suitable.

  • PDF

Electrical Breakdown in Flames

  • Han, S.Uhm
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.187-187
    • /
    • 2000
  • Properties of electrical discharge in flames are investigated by making use of the ionization cross section of air. Fames have three distictive features. They are hot, emit light and are weakly ionized. We investigate influence of these three characteristics of flames on the electrical breakdown. It is found that the breakdown electric field in flames is inversely proportional to the flame temperature, thereby easily generating plasmas in flames. A swarm of low-energy electrons in flames would allow significant population of electronically excited states of flame molecules to be formed. Therefore, the analysis shows that the electronic excitation of flame molecules may also considerably reduce the breakdown field. Plasma electrons generate atomic oxygens by the electron attachment of oxygen molecules in high-pressure flames. These oxygen atoms are the most reactive radicals in flames for material oxidation. How are you and your family in this new year\ulcorner Professor Choi! I plan to go back Korea on February 6. All my family members are fine and have good time because I am here. Once I am in Korea, I will call you. I am always grateful for your helpful hand. Thank you so much.

  • PDF

개선된 Dry Air와 SF6의 혼합비에 따른 절연파괴 특성 연구 (A Study on Characteristics of Insulation Breakdown by the Mixing Ratio of enhanced Dry Air and SF6)

  • 석정후;백종현;임동영;배성우;김기채;박원주
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.86-93
    • /
    • 2016
  • It is very desirable that a mixture gas possessing excellent insulation performance is suggested for insulation on increasing high voltage. This paper proposes a $SF_6$ mixture gas based on the factors including dielectric strength, environmental impact and economic feasibility of manufacture for the insulation in eco-friendly power equipment. A suitable-$SF_6$ content was determined to improve the dielectric strength in $N_2$ and Dry Air. The examination results of the factors revealed that a $SF_6$/Dry Air mixture gas possessing the $SF_6$ content was more appropriate than a $SF_6/N_2$ mixture gas to the eco-friendly power equipment. In addition to the selection of the suitable $SF_6$ mixture gas, insulation characteristics as a function of $SF_6$ content were described from electron-detachment mechanism.

Impulse Breakdown Behaviors of Dry Air as an Alternative Insulation Gas for SF6

  • Li, Feng;Yoo, Yang-Woo;Kim, Dong-Kyu;Lee, Bok-Hee
    • 조명전기설비학회논문지
    • /
    • 제25권3호
    • /
    • pp.24-32
    • /
    • 2011
  • [ $SF_6$ ]gas, which has an excellent dielectric strength and interruption performance, is used in various applications such as gas insulated switchgear (GIS) in substations. However, since $SF_6$ has a high global warming potential (GWP), it is necessary to find an eco-friendly alternative insulation gas. In order to examine the possibility of using alternative insulation gases for $SF_6$ in power distribution system equipment, the dielectric strength and physical phenomena of dry air in a quasi-uniform electric field are investigated experimentally in this paper. As a result, the breakdown voltages for positive polarity are higher than those for negative polarity under impulse voltage applications. The negative 50[%] flashover voltage, $V_{50}$ of dry air under conditions above 0.4[MPa] gas pressure, is higher than 150[kV], that is the basic impulse insulation level of distribution equipment. The $V_{50}$ increases linearly with increasing the gas pressure, regardless of the waveform and polarity of the applied impulse voltages. The voltage-time curves are dependent on the rise time of the impulse voltage and gas pressure. Furthermore, streamer discharge was observed through light emission images by an ICCD camera under impulse voltage applications.

침 전극 기울기에 따른 XLPE의 부분 방전 특성 (The Partial Discharge Characteristics of the XLPE According to the Tilt of the Needle Electrode)

  • 신종열;안병철;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.28-33
    • /
    • 2015
  • The needle electrode is inserted into the cross-linked polyethylene(XLPE) which is the ultra high voltage cable for electric power. By changing the tilt of the needle electrode, we investigated how the void and the thickness of the insulating layer influence the partial discharge(PD) characteristics and the insulating breakdown. In order to investigate the PD characteristics, The XLPE cable was used to the specimens and the tungsten electrode was used with the needle electrode. And the inner semi-conductive layer material of XLPE cable was used with the negative electrode by bonding with the use of conduction tape. The size of the specimens was manufactured to be $16{\times}40{\times}30[mm^3]$. We confirmed the effect on changing the PD characteristics according to the changing voltage and the tilt of the electrode after applying the voltage on the electrode from 1[kV] to 40[kV] at room temperature. In the PD characteristics, it was confirmed that the PD current of air void specimens with tilt was unstable more than that of no void specimens with tilt. It was also confirmed that the breakdown voltage was decreased because the effect of air void is more active than the change of the needle electrode tilt in the specimen with air void inside the insulation.

Insulation Breakdown Characteristics of Inverter Surge Resistant Enameled Wire Prepared with Organic/Inorganic Hybrid Nanocomposite

  • Park, Jae-Jun;Shin, Seong-Sik;Lee, Jae-Young;Han, Se-Won;Kang, Dong-Pil
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권4호
    • /
    • pp.190-193
    • /
    • 2015
  • Insulation breakdown characteristics of an inverter surge resistant enameled wire were investigated in a twisted pair prepared with organic/inorganic hybrid nanocomposite. Organic polymer was polyesterimide-polyamideimide (EI/AI) and inorganic material was a nano-sized silica. The enamel thickness was 50 μm and the diameters of enameled copper wires were 0.75, 1.024, and 1.09 mm, respectively. There were many air gaps in a twisted pair. Therefore, when the voltage was applied to the twisted pair, enamel erosion took place in the air gap area because of partial discharge according to Paschen’s law. The insulation lifetime of the hybrid wire (HW) was 41,750 sec, which was 515.4 times more than the 81 sec of EI/AIW. In addition, the shape parameter of HW was 2.58, which was 3.4 times higher than 0.75 of EI/AIW.

연소실 진단을 위한 LIBS 소형화 장비 개발 (Development of LIBS Plug for Combustor Diagnosis)

  • 전형민;김현우;여재익
    • 한국추진공학회지
    • /
    • 제23권2호
    • /
    • pp.53-59
    • /
    • 2019
  • 연소실 내부의 연료 분포를 실시간으로 측정하는 목적을 가진 소형화 장비인 LIBS plug가 개발 및 제작 되었다. LIBS plug는 레이저 유도 플라즈마 분광분석법 (Laser-induced breakdown spectroscopy : LIBS)를 응용한 장비로, 기존의 LIBS 결과인 전체 스펙트럼에서 당량비와 깊게 관여하는 두 개의 파장(H: 656.3 nm, O: 777 nm)만을 선정하여 측정할 수 있도록 하였다. 렌즈와 밴드패스 필터, 포토다이오드로 구성된 본 장비로 수집한 결과에 대한 분석이 이루어졌으며, 액체(가솔린)와 기체(LPG) 연료와 공기의 혼합물에서의 당량비 측정이 이루어졌다.