• 제목/요약/키워드: Air atmosphere

검색결과 1,572건 처리시간 0.029초

KEOP-2007 라디오존데 관측자료를 이용한 장마 특성 분석 : Part Ⅱ. 2007년 장마의 역학적 및 열역학적 특성에 관한 사례연구 (The Analysis of Changma Structure Using Radiosonde Observational Data from KEOP-2007: Part II. The Dynamic and Thermodynamic Characteristics of Changma in 2007)

  • 김기훈;김연희;장동언
    • 대기
    • /
    • 제19권4호
    • /
    • pp.297-307
    • /
    • 2009
  • The synoptic structures and the dynamic and thermodynamic characteristics of Changma in 2007 are investigated using the ECMWF analysis data and the radiosonde data from KEOP-2007 IOP. The enhancement of the North-Pacific High into the Korean peninsula and the retreat of the Okhotsk High are shown during the onset of Changma and the change of wind component from southwesterly to northwesterly is appeared during the end of Changma. The baroclinic atmosphere is dominant during Changma at most regions over the Korean peninsula except at Gosan and Sokcho. The quasi-barotropic atmosphere is induced at Gosan by warm air mass and Sokcho by cold air mass. Precipitation in the Korean peninsula occurs when dynamic instability is strengthened as the baroclinic and qusi-barotropic structure is weakened. An empirical orthogonal function (EOF) analysis is performed to find the dominant modes of variability in Changma. The first EOF explains the onset of Changma. The second EOF is related to the discrimination for existence and nonexistence of precipitation during Changma period according to the alternation of equivalent potential temperature between middle and lower atmosphere.

PZT 세라믹스이 압전 및 기계적 특성에 미치는 어닐링 분위기의 영향 (Effect of annealing Atmosphere on the Piezoelectric and Mechanical Properties of PZT Ceramics)

  • 임진호;손준호;김진호;조상희
    • 한국세라믹학회지
    • /
    • 제31권9호
    • /
    • pp.1037-1043
    • /
    • 1994
  • The effects of annealing atmosphere and temperature on piezoelectricity (k33) and the mechanical strength of machined PZT was studied. Morphotropic Nb-doped PZT was sintered, machined to a rod and then annealed between 80$0^{\circ}C$ and 100$0^{\circ}C$ in air, PbZrO3, and CuO atmospheres respectively. In air or PbZrO3 atmosphere, the compressive strength of Nb-doped PZT increased by 12% with little change in k33 irrespective of annealing temperature. In CuO atmosphere, on the other hand, the compressive strength increased by 20% with little change in k33 at 80$0^{\circ}C$ but both turned to significant decrease above 90$0^{\circ}C$. The examination of the phase distribution and microstructure beneath the surface of CuO-treated PZT revealed that the changes in compressive strength and k33 are closely related to the reaction between PZT and vaporized CuO:liquid PbO precipitated in shallow surface region by the substitution of Cu to Pb sites enhances the decrease in microcracks and the surface roughness at 80$0^{\circ}C$ ; rapid evaporation of precipitated PbO expands a porous region of changed composition into the bulk above 90$0^{\circ}C$.

  • PDF

Superconducting transitions of LuBa2Cu3O7-z heated under various atmospheres

  • Lee, M.S.;Lee, H.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권1호
    • /
    • pp.6-8
    • /
    • 2014
  • The influence of quenching temperature, heating atmosphere and annealing time on superconducting characteristics has been studied for $LuBa_2Cu_3O_{7-z}$ compound which has been recently synthesized in a nearly phase-pure form. Resistivity measurements for the as-prepared sample heated at $300^{\circ}C$ in oxygen and subsequently quenched into liquid nitrogen revealed that there is no significant change in $T_c$. On the other hand, $T_c$ of the sample slightly increased when the sample was heated at $300^{\circ}C$ either in air or in $N_2$ atmosphere. It was also found that $T_c$ of the sample decreased when the annealing temperature in $N_2$ atmosphere increased above $400^{\circ}C$. The experimental results indicated that the as-prepared sample is under overdoped state. The enhanced superconducting transition observed in the samples after heating at $300^{\circ}C$ in air or $N_2$ atmosphere was discussed in conjunction with a slight removal of oxygen and ordering of oxygen atoms in the as-prepared sample.

상압화학기상 증착법에 의한 반도체탄소나노튜브의 성장과 $300^{\circ}C$ 대기에서의 산화열처리 효과 (The semiconductor carbon nanotube growth with atmosphere pressure chemical vapor deposition method and oxidation effect at $300^{\circ}C$ in air)

  • 김좌연
    • 한국결정성장학회지
    • /
    • 제15권2호
    • /
    • pp.57-60
    • /
    • 2005
  • [ $SiO_2$ ]로 산화된 웨이퍼 위에 상압화학기상증착 기술로 반도체 탄소나노튜브를 성장했으며, 이 나노튜브의 전기적 특성을 조사하였다. 전기적 특성은 반도체 탄소나노튜뷰를 $300^{\circ}C$, 대기 중에서 산화 열처리 시간을 변화시키면서 상온대기에서 측정하였다. 반도체 탄소나노튜브는 $300^{\circ}C$에서 산화 열처리 시간을 증가할수록 점차적으로 금속 탄소나노튜브로 변형되는 것을 보았다. 탄소나노튜브는 $300^{\circ}C$, 대기에서 6시간 동안 산화 열처리 후 표면의 일부가 없어지는 현상을 투과 전자현미경으로 확인하였다.

공기 및 수소 분위기에서 열처리 된 Pt/Al2O3 촉매의 HI분해반응 특성 (The Characteristics of HI Decomposition using Pt/Al2O3 Catalyst Heat Treated in Air and Hydrogen Atmosphere)

  • 박은정;고윤기;박주식;김창희;강경수;조원철;정성욱;배기광;김영호
    • 한국수소및신에너지학회논문집
    • /
    • 제25권3호
    • /
    • pp.219-226
    • /
    • 2014
  • In HI decomposition, $Pt/Al_2O_3$ has been studied by several researchers. However, after HI decomposition, it could be seen that metal dispersion of $Pt/Al_2O_3$ was greatly decreased. This reason was expected of platinum loss and sintering, which platinum was aggregated. Also, this decrease of metal dispersion caused catalytic deactivation. This study was conducted to find the condition to minimize platinum sintering and loss. In particular, heat treatment atmosphere and temperature were examined to improve the activity of HI decomposition reaction. First of all, although $Pt/Al_2O_3$ treated in hydrogen atmosphere had low platinum dispersion between 13 and 18%, it was shown to suitable platinum form that played an important role in improving HI decomposition reaction. Oxygen in the air atmosphere made $Pt/Al_2O_3$ have high platinum dispersion even 61.52% at $500^{\circ}C$. Therefore, in order to get high platinum dispersion and suitable platinum form in HI decomposition reaction, air heat treatment at $500^{\circ}C$ was needed to add before hydrogen heat treatment. In case of 5A3H, it had 51.13% platinum dispersion and improved HI decomposition reaction activity. Also, after HI decomposition reaction it had considerable platinum dispersion of 23.89%.

각종 응용환경에서 WS$_2$ 고체윤활제의 마찰 계수 (Factors Controlling Friction Coefficient of WS$_2$ Solid Lubricant)

  • 신동우;윤대현;최인혁;김인섭
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1997년도 제26회 추계학술대회
    • /
    • pp.110-116
    • /
    • 1997
  • The tribological behaviour of WS$_2$ solid lubricant was investigated using a ball-on-disk type tester. The WS$_2$ powder was spray-coated at room temperature and the effects of specimen configuration, atmosphere, applied load and rotating spccd on the friction coefficient was examined. WS$_2$ coated ball and disk showed the lowest friction coefficient of 0.05 in the nitrogen atmosphere under 0.3 kgf and 100 rpm, whereas relatively high coefficient of 0.1 - 0.15 was observed in air atmosphere. This confirmed that the spray-coated WS$_2$ solid lubricant was effective in reducing the friction coefficient and improving wear life in nitrogen atmosphere.

  • PDF

암모니아 유니트 쿨러의 열성능 해석 (Analysis on the Thermal Performance of an Ammonia Unit Cooler)

  • 최재광;김무근;박병규
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1125-1133
    • /
    • 2001
  • Since the surface temperature of the evaporating tube in an ammonia unit cooled is lower than the dew point of atmosphere, the moisture in the atmosphere condenses and the frost grows on the tube. The frost of liquid film decreases the heat transfer rate. The reliable analysis of the heat transfer is required for the prediction of the optimal design of the ammonia unit cooler. For the specific commercial model, the performance was numerical1y estimated for the variation of operating condition and geometric configuration. It is found that there exists an optimum range for the parameters such as mass flow rate of air and refrigerant, humidity, refrigerant quality, fin pitch, the number of step, the number of rows and the pattern of refrigerant path.

  • PDF

도심지의 온열성상에 관한 연구 -제1보 도심지 온열환경 예측모델을 위한 실측조사- (Study on Thermal Property in Urban Area - Part 1 : Experimental Analysis for Predicting Methodology of Thermal Property in Urban Area -)

  • 손원득;이성
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.984-989
    • /
    • 2004
  • Significant air temperature increases in urban areas is well known as the heat island phenomenon in a global scale. Therefore, we propose numerical model in order to analyze quantitative effects of building environmental factors on the heat island phenomenon in urban area. In this paper, thermal property of upper atmosphere is experimentally investigated for Sakae, Nagoya Japan. In conclusion, it was confirmed that the boundary layer of a urban canopy existed near the altitude of 139 m.

갯벌에서 여름철 일몰 전후 이산화탄소 농도 변동 분석 (Variation Analysis of CO2 Concentrations at Sunset before and after of Summer Season at the Foreshore)

  • 강동환;권병혁;김박사
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.399-407
    • /
    • 2014
  • In this study, before and after sunset carbon dioxide concentration and air temperature were observed in two points of atmosphere (lower observation point of the GL + 0.1 m, the upper observation point of GL + 1.0 m) on the foreshore at located in Suncheon Bay and their variations were analyzed. Observation was performed on the foreshore on 2~4 August 2010. Instrument (VAISALA, GMP343) was set two hours before sunset and then observation was made continuously for six hours. In three days, observed carbon dioxide concentration was 375~419 ppm, and the air temperature was in the range of $28.7{\sim}32.5^{\circ}C$. The average concentration of carbon dioxide was 388~399 ppm in the upper observation point and 386~396 ppm in the lower observation point. It was higher in the upper observation point and its fluctuations were similar in two observation points. Correlation coefficients between carbon dioxide concentration and air temperature in the upper observation point were in the range of -0.64~-0.88, and were calculated -0.65 to -0.90 in the lower observation point. For the carbon dioxide concentration, correlation coefficients between the upper part and the lower part were very high as 0.98 in three times. For the air temperature, correlation coefficients between the upper part and the lower part were very high as 0.97 and 0.99. In the same observation time, the slope of the linear regression function as carbon dioxide concentration in the lower observation point for the upper observation point was in the range of 0.97~1.01. Carbon dioxide concentration was slightly higher in the upper observation point. Because carbon dioxide in the lower observation point was closer on the surface of the foreshore and absorbed from atmosphere to the foreshore. In this study, it was showed that the vertical variation of carbon dioxide concentration was insignificant in the several meter scale of atmosphere on the surface of the foreshore.

영동대설 사례와 관련된 동해상의 현열속과 잠열속 분포 특성 (Characteristics of Sensible Heat and Latent Heat Fluxes over the East Sea Related with Yeongdong Heavy Snowfall Events)

  • 김지언;권태영;이방용
    • Ocean and Polar Research
    • /
    • 제27권3호
    • /
    • pp.237-250
    • /
    • 2005
  • To investigate the air mass modification related with Yeongdong Heavy snowfall events, we examined sensible and latent heat fluxes on the East Sea, the energy exchange between atmosphere and ocean in this study. Sensible and latent heats were calculated by a bulk aerodynamic method, in which NCEP/NCAR reanalysis data and NOAA/AVHRR weekly SST data with high resolution were used. Among winter precipitation events in the Yeongdong region, 19 heavy precipitation events $(1995{\sim}2001)$ were selected and classified into three types (mountain, cold-coastal, and warm types). Mountain-type precipitation shows highly positive anomalies of sensible and latent heats over the southwestern part of the East Set When separating them into the two components due to variability of wind and temperature/ specific Humidity, it is shown that the wind components are dominant. Cold-coastal-type precipitation also shows strong positive anomalies of sensible and latent heats over the northern part and over the central-northern part of the East Sea, respectively. It is shown that the sensible heat anomalies are caused mostly by the decrease of surface air temperature. So it can be explained that cold-coastal-type precipitation is closely related with the air mass modification due to cold air advection over warm ocean surface. But in warm-type precipitation, negative anomalies are found in the sensible and latent heat distributions. From this result, it may be postulated that warm-type precipitation is affected by the internal process of the atmosphere rather than the atmosphere-ocean interaction.