• 제목/요약/키워드: Air Temperature Rise

검색결과 309건 처리시간 0.03초

낙동강 하구둑 건설 전·후의 기상환경 변화 특성 (Characteristics of Meteorological Environment Variation Before and After Construction of Nak-dong River Estuary Barrage)

  • 전병일
    • 환경영향평가
    • /
    • 제14권3호
    • /
    • pp.135-145
    • /
    • 2005
  • This study was conducted to investigate the characteristics of meteorological environment variation before and after construction of Nak-dong river estuary barrage. We used meteorological data(air temperature, precipitation, relative humidity, visibility, wind) at Gimhae airport meteorological station. The construction of river estuary barrage can change climate at the neighboring districts and influence human's health and vegetable. The construction of Nakdong river estuary barrage brought rise of temperature, decrease of relative humidity and increase of poor visibility frequency.

태양열과 지열을 이용한 난방용 공기순환시스템 기초연구 - 태양열을 이용한 트롬월식의 축열성능 중심으로 - (A Basic Study on the Air Circulation System for Heating using Solar and Geothermal Heat - Focused on Trombe Wall Thermal Storage Performance using Solar Heat -)

  • 김병윤;최용석
    • 한국농촌건축학회논문집
    • /
    • 제19권4호
    • /
    • pp.49-56
    • /
    • 2017
  • Each country in the world currently concentrates on shifting into clean energy, which can be alternative energy, for global environment protection and solution to the problem of fossil fuel depletion. The Korean government is predicted to develop renewable energy, such as solar power, ground power, and offshore wind power, and to increase their supply ratios by ending the use of coals and nuclear power plants. This study conducted experiments on thermal storage performance of Trombe wall thermal storage materials using solar power and simulations in order to offer baseline data for the development of a hybrid air circulation system for heating that can maximize efficiency by simultaneously using solar and geothermal power. The study results are as follows: (1) In all the specimens with 3m, 5m, and 7m in the length of thermal storage pipe, $5.7^{\circ}C$, $7.8^{\circ}C$, and $10.5^{\circ}C$ rose, respectively, as the thermal storage effect of the specimens attaching insulation film and black tape to the general funnel. They were most excellent in terms of thermal storage effect. (2) As a result of thermal performance evaluation on the II type specimens, II-3 ($7.8^{\circ}C$ rise) > II-4 ($5.3^{\circ}C$ rise) > II-1 ($3.9^{\circ}C$ rise) > II-2 ($2.3^{\circ}C$ rise) was revealed, and thus II-3 (insulation film + black tape) was most effective as shown in the I type. (3) This study analyzed air current and temperature distribution inside of the greenhouse by linking actually measured values and simulation interpretation results through the interpretation of CFD (computational fluid dynamics). As a result, the parts absorbing heat and discharging heat around the thermal storage pipe could be visibly classified, and temperature distribution inside of the greenhouse around the thermal storage pipe could be figured out.

식품분진의 폭발 특성과 발화온도에 관한 연구 (A study on the explosion properties and Autoignition Temperature of a food additive Dusts)

  • 안형환
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2001년도 춘계학술대회
    • /
    • pp.301-310
    • /
    • 2001
  • A study for the dangerous properties measurment of dust explosion was attended by the various dust concentration on Anthraquinone, Sodiumbenzoic acid, Corn starch, soy sauce powder, and cheese powder. As the result, maximum explosion pressure, the maximum rate of pressure rise, autoigntion temperature, and the water content of dust on lower limit explosion concentration was obtained as follows 1. The lower limit explosion concentration on soy sauce powder with the humidity of 65 to 90% increased by increasing the con tent of moisture, and the effect of dry air and moisture air decreased better in make of dry air. 2. The effect of a various dust concentration on autoigntion temperatures is investigated, If the vessel of dust explosion is small size and the easiness of autoignition was controled by air within the vessel, because it was better decreased air with increasing of dust concentration 3. The maximum explosion pressures of Anthraguinone, sodiumbenzoic acid, com starch, soy sauce powder, and cheese powder were 1.0g/$\ell$, 1.0g/$\ell$, 1.5g/$\ell$, 1.5g/$\ell$, and 1.5g/$\ell$, respectively, and the maximum rate of pressure rise were 0.5g/$\ell$, 0.5g/$\ell$, 1.0g/$\ell$, 1.0g/$\ell$, and 1.0g/$\ell$, respectively.

  • PDF

HVFA 콘크리트의 기초물성 및 단열온도상승 특성에 관한 실험적 연구 (An Experimental Study on the Fundamental and Adiabatic Temperature Rise Properties of High Volume Fly Ash Concrete)

  • 김성수;최세진;정용;임창근;박대균;조윤구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.309-310
    • /
    • 2010
  • 본 연구에서는 플라이애시를 대량 사용한 콘크리트의 기초 물성 및 단열온도상승 특성에 대하여 검토하였다. 이를 위하여 플라이애시를 시멘트량에 대하여 40% 및 50% 사용한 콘크리트 배합에 대하여 슬럼프, 공기량, 블리딩, 압축강도 및 단열온도상승 시험을 실시하였다.

  • PDF

도시의 기온 분석을 통한 지역별 열 환경 특성 해석과 동·하절기 계절 간 비교연구 (Comparison Study on Thermal Environment Characteristics in Each Region and the Seasons of Summer and Winter Through Air Temperature Analysis in Urban Areas)

  • 최동호;이부용
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.83-93
    • /
    • 2012
  • This study is to perform the effect of urbanization in urban and suburban districts, and to identify regional characters of climate according to the analysis of slope at rise, and descent of temperature and globe temperature, correlation between seasonal temperature analysis, and calculation of degree hour. According to this study, the result is summarized as follows. (1) The average temperature, rated from high to low, consists of residential area, Daegu weather station, intracity, green belt, water-front green belt, and suburban. (2) At the rise and descent of temperature, the result of the slope change of in each point may be one of the useful indexes to be able to perform the regional unique thermal characteristic, including the seasonal urbanization. (3) Although there is a difference between the surface of the earth and ambient environment. The result of the correlation of temperature between summer and winter is that temperature slope in urban districts was higher than in suburban districts, and the difference of slope was unvaried among the four observations in the same city region. (4) To show objectively, regional thermal characteristics in urban and suburban districts, the exponentiation of winter degree hour and summer degree hours were checked. The result of the exponentiation is that the more artificial a region, the lower index.

일체형 주상용 몰드 변압기의 온도분포 및 특성 비교 (Temperature Rise Test and Temperature Distribution Analysis of Pole Mount Mold Transformer with One-body Molding)

  • 조한구;이운용;강택수;최인혁
    • 한국전기전자재료학회논문지
    • /
    • 제19권12호
    • /
    • pp.1154-1159
    • /
    • 2006
  • The mold transformers have been widely used in underground substations of large building and have some advantages when compared with oil-transformer. Those advantages are low fire risk, environmental compatibility, compact size and high reliability. The mold transformer is generally known to have cooling duct between low voltage and high voltage coil. To achieve better compact structure and low loss, mold transformers made by one body molding method has been developed. Nevertheless, such kinds of transformer need better cooling method because heat radiation between each winding is still of problem. The life of transformer is significantly dependent on the thermal behavior in windings. Many designers have calculated temperature distribution in transformers and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, the temperature distribution analysis of 100 kVA pole mold transformer for power distribution were investigated by FEM program and the thermal analysis results were compared with temperature rise test.

신경망모형을 이용한 새만금호 수온 예측 (The Prediction of Water Temperature at Saemangeum Lake by Neural Network)

  • 오남선;정신택
    • 한국해안·해양공학회논문집
    • /
    • 제27권1호
    • /
    • pp.56-62
    • /
    • 2015
  • 지구 온난화의 영향으로 해수면과 기온이 상승하고, 이의 직접적인 영향으로 수온이 증가하고 있다. 지구 온난화가 하천의 수질과 생태 환경에 미치는 영향을 추정하기 위해서는 수온에 대해 이해하고 수온의 변화를 예측할 필요가 있다. 이 연구에서는 수온의 변화를 예측하기 위하여 기온과 수온자료를 입력자료로 하여 수온의 예측을 실시하였다. 2012년에서 2014년까지 환경부의 수질환경관측소에서 관측한 새만금호내의 신시, 가력, 만경, 동진 4개 지점의 수온자료와 기상청에서 같은 기간에 관측한 부안의 자동관측 기온 자료를 활용하였다. 신경망이론을 이용하여 최고 및 최저 수온을 예측한 결과 4개 지점의 모든 결과에서 아주 높은 상관계수를 가지고 있다.

저탄소 그린콘크리트의 물리·역학적 특성 (Physical and Mechanical Properties of Low Carbon Green Concrete)

  • 조일호;성찬용
    • 한국농공학회논문집
    • /
    • 제55권3호
    • /
    • pp.123-128
    • /
    • 2013
  • This study was performed to evaluate the slump flow, air content, setting time, compressive strength, adiabatic temperature rise and diffusion coefficient of chloride used ordinary portland cement, crushed coarse aggregate, crushed sand, river sand, fly ash, limestone powder, blast furnace slag powder and superplasticizer to find optimum mix design of low carbon green concrete for structures. The performances of low carbon green concrete used fly ash, limestone powder and blast furnace slag powder were remarkably improved. This fact is expected to have economical effects in the manufacture of low carbon green concrete for structures. Accordingly, the fly ash, limestone powder and blast furnace slag powder can be used for low carbon green concrete material.

Loss Analysis and Air-Cooled Design for a Cascaded Electrical Source Transmitter

  • Xue, Kai-Chang;Wang, Shuang;Lin, Jun;Li, Gang;Zhou, Feng-Dao
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.530-543
    • /
    • 2015
  • Air-cooling method is adopted on the basis of the requirements for the thermal stability and convenient field use of an electrical source transmitter. The power losses of the transmitter are determined after calculating the losses of the alternating current (AC)-direct current (DC) power supply, the constant-current circuit, and the output circuit. According to the analysis of the characteristics of a heat sink with striped fins and a fan, the engineering calculation expression of the Nusselt number and the design process for air-cooled dissipation are proposed. Experimental results verify that the error between calculated and measured values of the transmitter losses is 12.2%, which meets the error design requirements of less than 25%. Steady-state average temperature rise of the heat sink of the AC-DC power supply is $22^{\circ}C$, which meets the design requirements of a temperature rise between $20^{\circ}C$ and $40^{\circ}C$. The transmitter has favorable thermal stability with 40 kW output power.

도시 캐노피 층 기온과 상대습도의 일변화에 관한 수치 모의 (Numerical Simulations of Diurnal Variations of Air Temperature and Relative Humidity in the Urban Canopy Layer)

  • 박경주;한범순;진한결
    • 대기
    • /
    • 제31권3호
    • /
    • pp.295-309
    • /
    • 2021
  • Diurnal variations of air temperature and relative humidity in the Urban Canopy Layer (UCL) of the Seoul metropolitan area are examined using the Weather Research and Forecasting model coupled with the Seoul National University Urban Canopy Model. The canopy layer air temperature is higher than 2-m air temperature and exhibits a more rapid rise and an earlier peak in the daytime. These result from the multiple reflections of shortwave radiation and longwave radiation trapping due to the urban geometry. Because of the absence of vegetation in the UCL and the higher canopy layer air temperature, the canopy layer relative humidity is lower than 2-m relative humidity. Additional simulations with building height changes are conducted to examine the sensitivities of the canopy layer meteorological variables to the urban canyon aspect ratio. As the aspect ratio increases, net sensible heat flux entering the UCL increases (decreases) in the daytime (nighttime). However, the increase in the volume of the UCL reduces the magnitude of change rate of the canopy layer air temperature. As a result, the canopy layer air temperature generally decreases in the daytime and increases in the nighttime as the aspect ratio increases. The changes in the canopy layer relative humidity due to the aspect ratio change are largely determined by the canopy layer air temperature. As the aspect ratio increases, the canopy layer relative humidity is generally increased in the daytime and decreased in the nighttime, contrary to the canopy layer air temperature.