• 제목/요약/키워드: Air Temperature Rise

검색결과 308건 처리시간 0.042초

CFD를 활용한 새만금 시설원예 예정지 최고온도 분포 및 개선방안 (The Maximum Temperature Distribution and Improvement Plan of Protected Horticulture Planning Area in Saemanguem Using CFD Simulation)

  • 손진관;최덕규;박민정;윤성욱;공민재;이승철;김창현;강동현
    • 농촌계획
    • /
    • 제25권3호
    • /
    • pp.115-128
    • /
    • 2019
  • The A1B scenario predicts that the mean air temperature of South Korea will rise up to $3.8^{\circ}C$ by 2071. However, the effects of ecosystem services are declining because of various environmental problems, including climate change, land use change, stream intensification, non-point pollution, and untreated garbage. Moreover, horticultural sites which have various ecosystem services suffer highly absorbed heat from the heat island phenomenon associated with climate change. Therefore, we analyzed the heat island phenomenon occurring in an protected horticulture estimated area in Saemanguem, South Korea. Using an advanced measurement method, we examined the air temperature change derived from water channels as well as open spaces. The CFD analysis of coverage ratio 85% design showed wind speed of 2.09 m/s and temperature of $38.07^{\circ}C$. At a coverage ratio of 70%, the wind speed was improved to 2.61 m/s and the temperature was improved to $36.89^{\circ}C$. In Alternative 2 with wetlands and trees, the wind speed was 2.71 m/s and the temperature was $35.90^{\circ}C$. When the coverage ratio decreases to 55%, the wind speed increases showing 3.06 m/s and the temperature decreases showing $35.18^{\circ}C$.

증기터빈 익렬유동에 관한 실험적 연구 (Experimental Study on Stream Turbine Cascade Flow)

  • 권순범;윤의수;김병지
    • 대한기계학회논문집
    • /
    • 제18권8호
    • /
    • pp.2177-2183
    • /
    • 1994
  • The rapid expansion or condensible gas such as moist air of steam gives rise to nonequilibrium condensation. As a result of irreversibility of condensation process in the supersonic cascade flow of low pressure steam turbine, the entropy of the flow is increased, and the efficiency of the turbine is decreased. In the present study, to investigate the flow of moist air in 2-dimensional cascade made as the configuration of the tip section of the last actual steam turbine moving blade, the static pressure at both sides of pressure and suction of blade are measured by static pressure taps and the distribution of Mach number on both surfaces of the blade are obtained by using the measured static pressure. Also, the flow field is visualized by a schlieren system. From the experimental results, the effects of the stagnation temperature and specific humidity on the flow properties in a 2-dimensional stationary cascade of a practical steam turbine blade are clearly identified.

프랑스 고속철도 전차선로 시스템에서 균압선의 문제점 (The question at issue of connector wire in High Speed Railway Catenary System of France)

  • 안영훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.636-651
    • /
    • 2000
  • In these days, SNCF replace the connector wire (M-T type) with a dropper has a equivalent role and function of the one in general lines of TGV, and change the connector wire (T-T-M-M-T-T, T-T-M-M-T type, etc) into a New one has more flexible cable in parallel lines (air section air joint, etc) of TGV. The Connector wire has many problems according to a flow of excessive circulation current (or traction current) and a sudden rise of temperature on catenary when electric locomotive is running in high speed. To solve the question at issue of the connector wire in high speed railway catenary system of Fiance, SNCF return their operating experience in TGV lines to design and execution of catenary system Therefore, we have to deal with the question in design and execution of catenary system for kyoungbu HSR line because we will spend a lot of time and more money for maintenance than for construction of that.

  • PDF

좁은 공간 내의 밀폐형 장치 냉각시스템에 대한 열평형 평가 (Evaluation of Heat Balance for Cooling System of an Armored Installation in Small Space)

  • 김성광;안석환;남기우
    • 한국해양공학회지
    • /
    • 제21권3호
    • /
    • pp.1-7
    • /
    • 2007
  • In this study, the heat balance test of an engine was conducted, and the heat released to coolant is measured and corrected using a power adjustment factor for high fuel temperature to simulate heat rejection of the engine. An engine-converter matching simulation program which can compute the engine speed, transmission output speed, transmission input and output power is developed from the vehicle, transmission and engine performance curve. With this information and the engine heat rejection characteristics, the engine and transmission heat rejection rates can be determined at given condition. In analyzing the air mass flow, a sub program computing the air mass flow rate from the equation of the pressure balance between cooling fan static pressure rise and pressure losses of cooling components is developed.

Stack Effect Guidelines for Tall, Mega Tall and Super Tall Buildings

  • Simmonds, Peter;Zhu, Rui
    • 국제초고층학회논문집
    • /
    • 제2권4호
    • /
    • pp.323-330
    • /
    • 2013
  • The ASHRAE Technical Committee for Tall Buildings, TC 9.12, has defined a tall building as one whose height is greater than 300 feet (91m). Since the publication of the HVAC Design Guide for Tall Commercial Buildings in 2004, there were only about 300 buildings taller than 200 meters; this number has risen to 600 in 2010 and the prediction 765 buildings taller than 200 meters in 2012. There has also been an introduction of two new classes of tall buildings: ${\bullet}$ Mega tall, which are buildings taller than 300 m, and ${\bullet}$ Super tall, which are buildings taller than 600 m. The effect of ambient air temperature over the height of buildings, especially Mega tall and Super tall buildings. The ambient climatic conditions vary with altitude and these changes in ambient conditions can seriously affect load calculations and performance of super and mega tall buildings. This paper presents revised calculations for stack effect for Tall, Mega Tall and Super tall Buildings.

순차적 근사최적화 기법을 이용한 방열판 최적설계 (Optimal Design of a Heat Sink using the Sequential Approximate Optimization Algorithm)

  • 박경우;최동훈
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1156-1166
    • /
    • 2004
  • The shape of plate-fin type heat sink is numerically optimized to acquire the minimum pressure drop under the required temperature rise. In constrained nonlinear optimization problems of thermal/fluid systems, three fundamental difficulties such as high computational cost for function evaluations (i.e., pressure drop and thermal resistance), the absence of design sensitivity information, and the occurrence of numerical noise are commonly confronted. Thus, a sequential approximate optimization (SAO) algorithm has been introduced because it is very hard to obtain the optimal solutions of fluid/thermal systems by means of gradient-based optimization techniques. In this study, the progressive quadratic response surface method (PQRSM) based on the trust region algorithm, which is one of sequential approximate optimization algorithms, is used for optimization and the heat sink is optimized by combining it with the computational fluid dynamics (CFD).

Mobility Enhancement in Polycrystalline Silicon Thin Film Transistors due to the Dehydrogenation Mechanism

  • Lee, Seok Ryoul;Sung, Sang-Yun;Lee, Kyong Taik;Cho, Seong Gook;Lee, Ho Seong
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1329-1333
    • /
    • 2018
  • We investigated the mechanism of mobility enhancement after the dehydrogenation process in polycrystalline silicon (poly-Si) thin films. The dehydrogenation process was performed by using an in-situ CVD chamber in a $N_2$ ambient or an ex-situ furnace in air ambient. We observed that the dehydrogenated poly-Si in a $N_2$ ambient had a lower oxygen concentration than the dehydrogenated poly-Si annealed in an air ambient. The in-situ dehydrogenation increased the (111) preferred orientation of poly-Si and reduced the oxygen concentration in poly-Si thin films, leading to a reduction of the trap density near the valence band. This phenomenon gave rise to an increase of the field-effect mobility of the poly-Si thin film transistor.

PC 적용을 위한 고강도 매스콘크리트의 수화특성에 관한 연구 (Study on Hydration Properties of High Strength Mass Concrete to apply Precast Concrete)

  • 박흥이;김성진;이회근;이승훈;박병근;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.661-664
    • /
    • 2008
  • 고층 대형 건축물에 사용되는 기둥 보 등의 단면치수가 큰 Precast Concrete 부재는 제조과정에 있어서 외부에서의 가열뿐만 아니라, 시멘트수화열의 축척에 의한 내부에서의 온도 상승도 작용되기 때문에, 단면치수가 비교적 작은 벽, 밑바닥 등의 Precast Concrete 부재와는 다른 온도이력을 나타낸다고 생각할 수 있다. 이에 본 연구는 Precast Concrete적용을 위한 고강도 매스콘크리트 부재의 강도특성을 검토하기에 앞서, 온도이력특성을 밝히는 것을 목적으로 했다. 단면치수가 큰 Precast Concrete 모의부재의 단면치수, 단위시멘트량, 양생조건이 가각 다른 Precast Concrete 부재를 제조할 때의 온도이력특성을 총괄적으로 검토하여 분석하였다.

  • PDF

초대형 매트기초 매스 콘크리트의 응결시간조정에 의한 온도균열저감 공법적용의 기초적 실험 (A Fundamental Test of Temperature Crack Reduction Method Application by Setting Time Control of Large-Scaled Mat Foundation Mass Concrete)

  • 한천구;이재삼;노상균
    • 한국건축시공학회지
    • /
    • 제9권3호
    • /
    • pp.95-101
    • /
    • 2009
  • Constructing large-scale mat foundation mass concrete is increasing for the stability of building structure, because a lot of high rise building are being built in order to make full use of limited space. However, It is of increasing concerns that because limited placing equipments, available job-site and systems for mass concete placement in construction field do not allow to place great quantity of concrete at the same time in large scale mat foundation, consistency between placement lift can not be secured. And also, it is likely to crack due to stress caused by the difference of hydration heat generation time. To find out the solution against above problems, this study is to reconfirm the performance of normal concrete designed by mix proportion and super retarding concrete. The Fundamental test shows what happens if low heat proportioning and control method of setting time are applied at the job-site of newly constructed high rise building. The test result show that slump flow of concrete has been somewhat increased as the target retarding time gets longer, while the air content has been slightly decreased but this is no great difference from normal concrete. The setting time shows to be retarded as target retarding time gets longer, the range of retarding time increases. It is necessary to increase the amount of mix of super retarding agent in the proportion ration by setting curing temperature high since outdoor curing is about 6 hours faster than standard curing, which means the temperature of the concrete will be higher than the temperature of the surrounding environment, due to its high hydration heat when applying in a construction site. The compressive strength of super retarding concrete appears to be lower than normal concrete due to the retarding action in the early stage. However, as the time goes by, the compressive strength gets higher, and by the 28th day the strength becomes the same or higher than normal concrete.

건축물 구획실간 틈새에서의 누설유동에 대한 수치모델 연구 (Study on Numerical Model of Leakage Flow at Gap between Compartments in a Building)

  • 김정엽;김지석
    • 설비공학논문집
    • /
    • 제25권10호
    • /
    • pp.562-567
    • /
    • 2013
  • 1D-numerical analysis of the network algorithm with the orifice equation for the relationship between pressure difference and flowrate has been mostly used to analyse leakage flow at the gap. In this study, a 3D-numerical method applying momentum loss model to the gap region in the computational domain is represented to reflect effectively the effect of leakage flow by determining the proportion of pressure difference to air passage velocity. While the 3D-numerical method is verified through the computation of the two compartments model, the numerical analysis of the stack effect in a building stairway is performed. As the temperature of air outside drops, the pressure in the upper stairway and leakage flowrate through the gap in the door rise. The change of gap area does not have an effect on pressure in the stairway for the analysis conditions.