• 제목/요약/키워드: Air Tank

검색결과 607건 처리시간 0.022초

Optimization of drag reduction effect of air lubrication for a tanker model

  • Park, Seong Hyeon;Lee, Inwon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권4호
    • /
    • pp.427-438
    • /
    • 2018
  • The reduction of $CO_2$ emissions has been a key target in the marine industry since the IMO's MEPC published its findings in 2009. Air lubrication method is one of the mature technologies for commercialization to reduce the frictional resistance and enhance fuel efficiency of ships. Air layer is formed by the coalescence of the injected air bubbles beyond a certain air flow rate. In this study, a model ship (${\lambda}=33.33$) of a 50,000 ton medium range tanker is equipped with an air lubrication system. The experiments were conducted in the 100 m long towing tank facility at the Pusan National University. By selecting optimal air injector configuration and distribution ratio between two injectors, the total resistance of model $R_{TM}$ was able to be reduced down to 18.1% in the model scale. Key issue was found to suppress the sideway leakage of injected air by appropriate injection parameters.

물 순환 및 에어레이션용 에어리프트 펌프의 성능 (Performance of Airlift Pumps for Water Circulation and Aeration)

  • 오세경
    • 한국수산과학회지
    • /
    • 제25권6호
    • /
    • pp.529-537
    • /
    • 1992
  • 본 실험은 에어리프트 펌프의 펌핑 성능과 에어레이션 능력을 조사하기 위해 수행했다. 펌프로는 2, 3, 4, 6인치 내경의 PVC 파이프를 사용했으며 펌프의 길이는 34.5인치였다. 공기 공급장치로는 정격 1 마력의 불로워를 사용하였다. 공기 유량 계측은 유량 게이지(풍속계)를 사용하였으며, 공기 압력은 물이 펌핑될 때 수위 변화로 측정했다. 펌프에 의한 에어레이션 성능 시험은 표준 에어례이션 테스트 방법으로 수행했다. 그 때 펌프출구의 중심선의 위치는 물 표면으로부터 3인치 위가 되도록 설정하였다. 수중의 산소농도는 에어레이션율을 산출하기 위하여 측정되었다. 탱크 속에서 수위 설정은 에어리프트 점프의 위치를 상하로 변경시켜 조절했다. 그 결과 수면에서 펌프의 위치가 높은 상태에서 물의 토출양은 공기의 공급량이 증가함에 따라 감소했다. 물 토출량의 감소율은 4인치와 6인치 펌프에서 높았으며, 직경이 작은 펌프에서 감소율은 그 정도가 미미했다. 시간의 변화에 따라 측정한 각 펌프의 에어레이션 성능은 2인치 펌프를 제외하고 3, 4, 6인치 펌프에서 비슷한 결과를 보았다. 6인치 펌프는 점핑 수두를 최소로 했을 때 가장 우수한 물 순환 효과를 얻을 수 있었다.

  • PDF

BNR 하수처리시스템에서 효과적 고형물 분리를 위한 DAF 공정의 적용과 처리특성 (Treatment Characteristics and Application of DAF Process for Effective Solid Separation in BNR Municipal Wastewater Treatment System)

  • 곽동희;유대환
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.267-276
    • /
    • 2010
  • Many plants have been improved to adapt the target of the biological treatment processes changed from organics to nutrients since the water quality criteria of effluent was reinforced and included T-N and T-P for the municipal wastewater treatment plant. To meet the criteria of T-N and T-P, the conventional biological reactor such as aeration tank in activated sludge system is changed to the BNR (biological nutrient removal) processes, which are typically divided into three units as anaerobic, anoxic and oxic tank. Therefore, the solid separation process should be redesigned to fit the BNR processes in case of the application of the DAF (dissolved air flotation) process as an alternatives because the solid-liquid separation characteristics of microbial flocs produced in the BNR processes are also different from that of activated sludge system as well. The results of this study revealed that the microbial floc of the anaerobic tank was the hardest to be separated among the three steps of the unit tanks for the BNR processes. On the contrary, the oxic tank was best for the removal efficiency of nutrients as well as suspended solid. In addition, the removal efficiency of nutrients was much improved under the chemical coagulation treatment though coagulation was not indispensable with a respect to the solid separation. On the other hand, in spited that the separation time for the microbial floc from the BNR processes were similar to the typical particles like clay flocs, over $2.32{\times}10^3$ ppm of air volume concentration was required to keep back the break-up of the bubble-floc agglomerates.

제과공장의 폐수처리장에서 발생하는 악취 저감 (Reduction of the Offensive Odor from Confectionery Wastewater Plant)

  • 김영식;손병현;조상원;정종현
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.62-69
    • /
    • 1998
  • It has been studied that the measurement of odor component emission at confectionery manufacture. The objects of this study were to investigate reduction of offensive odor. The survey effects of odorous materials are presented as follows. The countermeasure of operating process is to minimize sludge sediment in each unit facility. Especially, in summer, we have to clean the sludge frequently, because anaerobic decomposing is likely to occur easily. The sludge or scum from sedimentation tank pond, and floating tank should be treated quickly. We should avoid overloading operation. In the case of overloading, dissolved oxygen should be increased, the quality of wastewater input should be decreased. When dried cakes from condense tank or floating tank are left in treatment plant, we should cover, to prevent diffusion of smell with masking materials. The seasonal condition of operating should be fixed and the kind of coagulants should be changed because the wastewater in each season have different loading rates and organic materials. Odorous materials are very sensitive to the seasonal temperature variation. Especially, when the amount of rainfall is small and the high temperature of maintenance in long periods, air diffusion rate is large, so odorous materials can make great effect on surroundings comparision with other periods. To reduce odorous gas, as short term method, we had better take ceramic addition method. Especially, in summer we should take ceramic addition method. Also, as long term method, the size of wastewater treatment facility is the most important in the normal operating of wastewater treatment facility. But wastewater treatment facilities in this factory are too old, treatment process is old fashion, and the size is too small. So, large wastewater quantity to treat in summer. As results, the expansion of wastewater treatment facility and the process of improvement are required. Restriction level of odor was exceed. As it is overloaded in summer, the basis cause of odor is that the size of wastewater treatment facility is small. The prediction of air quality equilibrium density variation show that the odorous materials from working place are Amine materials whose smell strength is about 2.5(a little strong degree). We can suppose that in summer is sensitive to temperature variation, smell strength is larger as to reduce the origin of odor. We must expand wastewater treatment facility and improve the process A.S.A.P.

  • PDF

초.중.고등학교 시설의 급수 사용량에 대한 연구 (A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities)

  • 김규생
    • 설비공학논문집
    • /
    • 제20권12호
    • /
    • pp.802-807
    • /
    • 2008
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows; 1) On the whole, typical rates of water-use was founded out 15 L/stu. d in pirmary school, 10 L/stu. d in middle school and 30 L/stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking peak load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

산업배열 및 부산물을 활용한 1톤급 바이오수소 생산 시뮬레이터 동적 열설계 (Dynamic thermal Design of a 1-ton Class Bio-Hydrogen Production System Simulator Using Industrial Waste Heat and by-Products)

  • 김혜준;김석연;안준
    • 설비공학논문집
    • /
    • 제29권5호
    • /
    • pp.259-268
    • /
    • 2017
  • This paper proposes a hydrogen-based social economy derived from fuel cells capable of replacing fossil fuels and resolving global warming, It thus provides an entry for developing economically feasible social configurations to make use of bio-hydrogen production systems. Bio-hydrogen production works from the principle that microorganisms decompose water in the process of converting CO to $CO_2$, thereby producing hydrogen. This study parts from an analysis of an existing 157-ton class NA1 bio-hydrogen reactor that identifies the state of feedstock and reactor conditions. Based on this analysis, we designed a 1-ton class bio-hydrogen reactor process simulator. We carried out thermal analyses of biological heat reactions, sensible heat, and heat radiation in order to calculate the thermal load of each system element. The reactor temperature changes were determined by modeling the feed mixing tank capacity, heat exchange, and heat storage tank. An analysis was carried out to confirm the condition of the feed mixing tank, heat exchanger, heat storage tank capacity as well as the operating conditions of the system so as to maintain the target reactor temperature.

가정용 고분자 전해질 연료전지 열병합 발전시스템의 급탕 적용을 위한 온수 저장조의 최적 설계에 관한 실험적 연구 (Experimental Investigation on the Optimal Design of Water Tank for Domestic Hot Water Supply using PEMFC Co-generation System)

  • 황유진;안영철;정성일;진근호;이재근
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.394-399
    • /
    • 2008
  • There are many attempts to use a fuel cell system as a residential power generation system. The purpose of this study is to investigate the optimal design of a water tank for a hot water system when the fuel cell co-generation system is combined with a domestic hot water supply system. The demands of hot water supply per month per home are investigated in Busan for a year. It showed somewhat large differences between the actual demand and the designed demand of hot water, but the actual capacity of hourly averaged hot water demands is analyzed as $60{\ell}/h$ in this study based on the actual demand. The experiments are performed in the various inlet and outlet locations of nozzles, and the hot water consumption rates. The experimental results are showed that the optimal capacity of the water tank is $200{\ell}$ when the thermal efficiency, the storing capacity of hot water and the space for installation are considered.

전차병복 착용실태에 관한 연구 (A Study on the Actual Wearing Conditions of Korean Military Tank Driver's Clothing)

  • 권서윤;임채근;신동우;정현미
    • 한국의류산업학회지
    • /
    • 제13권4호
    • /
    • pp.582-589
    • /
    • 2011
  • The purpose of this study was to investigate problems of design, fitness, suitability for movement, and comfort in current Korean military tank driver's clothing through analysis of actual wearing condition by questionnaire and field evaluation and. to provide basic data for developing a improved design of Korean military tank driver's clothing. The survey was done for 477 military tank driver and the field evaluation was also done for evaluation. The overall satisfaction for design of military tank driver's clothing(3.25) was higher than that for the easiness in wearing and taking off(2.76). The military tank drivers evaluated that current coverall type of clothing is more suitable than two-piece type of clothing. The overall satisfaction for fitness of clothing was as a whole low(2.82~3.09), Especially, the satisfaction for fitness of from front and back rise length was the lowest one. In the satisfaction for clothing materials, the satisfaction for the breathability of material was the lowest, followed by clothing insulation and air permeability. The satisfaction for movement was low in bending waist and raising forward and aside. The part which surveyors think most dissatisfactory was also front and back rise length. The frequency in use of pocket was the highest in chest pocket, followed by waist and pants pockets. The satisfaction for opening easiness of hips opening part was very low(2.64).

자동차용 에어컨의 단품 성능에 관한 연구 (A Study on the Component Performance for Automotive Air Conditioner)

  • 이대웅;유성연
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.293-303
    • /
    • 2002
  • For successful design of component, performances of one-tank plate type evaporator, gas-liquid separation type condenser, swash plate type compressor and thermostatic expansion valve for automotive air conditioner are investigated experimentally. Heat transfer characteristics in the evaporator are examined by means of air temperature, relative humidity, air volume flow, outlet refrigerant pressure and superheat, and heat transfer characteristics in the condenser are examined by means of air temperature, air velocity and inlet refrigerant pressure. Pressure drops for both evaporator and condenser are measured arid empirical correlations are derived. Volumetric efficiencies and isentropic efficiencies for trio types of compressors with different capacity are measured and compared. Thermostatic expansion valve is tested to investigate the pressure variation according to temperature changes.

기액분리기를 적용한 가스 인젝션 히트펌프의 성능 향상에 관한 실험적 연구 (The Performance Improvement of a Gas Injection Heat Pump with a Flash Tank)

  • 손길수;김동우;최성경;김용찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.297-305
    • /
    • 2017
  • Air-source heat pumps are widely used in residential heating systems. However, the decrease in the capacity of the heat pump is unavoidable when operating at very low and high ambient temperatures. The vapor injection technique is considered a promising technology to overcome this problem. Recent research on vapor injection cycles have mainly adopted a scroll compressor with an internal heat exchanger at severe operating conditions. This study measured the COP and EER of a gas injection heat pump using a flash tank with an inverter-driven rotary compressor at severe operating conditions. Compared to non-injection heat pumps, the heating capacity and COP of the gas injection heat pump improved up to 15% and 2.9%, respectively, at outdoor temperatures of $-10^{\circ}C$ to $7^{\circ}C$. The cooling capacity of the gas injection heat pump was 11% higher than the non-injection heat pump at an outdoor temperature of $35^{\circ}C$. At the same time, the EER of the gas injection heat pump was similar to that of the non-injection heat pump.