• Title/Summary/Keyword: Air Pollution Cost

Search Result 161, Processing Time 0.025 seconds

A Study on the Priority Analysis of Government Support Policies for SOx Emission of Ships

  • Yang, Han-Na;Lee, Gwang-Un;Shin, Chang-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.43 no.2
    • /
    • pp.86-92
    • /
    • 2019
  • IMO has enacted a convention that air pollution due to emissions of ships and sulfur oxides emissions should be significantly reduced by 2020. Based on the current support policies, this work intended to draw up the government support plans required by the shipping companies. Analytic Hierarchy Process analysis was done with factors derived from brainstorming and literature studies. The analysis results showed that the cost factor was generally the most important criterion and the Financial Aid was relatively more important within this cost factor. The policy implications for the regulation of sulfur oxides emissions was provided.

A Study on the Performance of a Short Term Ozone Passive Sampler in Experimental Chamber (단기 측정용 오존 간이 측정기의 실험 챔버 내에서 성능에 관한 연구)

  • Jeong, Sang-Jin
    • Journal of Environmental Science International
    • /
    • v.16 no.8
    • /
    • pp.1001-1009
    • /
    • 2007
  • Passive sampler is a simple and cost-effective measuring equipment for ambient and indoor air pollution. We studied the performance of a short term (1 hour mean concentration) ozone passive sampler which was coated with a colorant (indigo carmine) to a filter substrate. Acetone and sulfamic acid added ozone passive sampler was investigated to measure short term mean ozone concentration. Ozone response and interference of criteria air pollutant($SO_2,\;NO_2$, CO) on a short term ozone passive sampler was tested through experimental chamber. The results show sulfamic acid added passive ozone sampler have good response in ozone exposure. Interference of $NO_2$ gas is larger than other two criteria gases.

A Study on the Optimization of Fuel Allocation for the Management of Sulfur Dioxide Pollution (亞黃酸가스 汚染度 管理를 위한 燃料配分의 最適化에 관한 硏究)

  • 安徹;金丁勖
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.103-110
    • /
    • 1986
  • Since sulfur dioxide is released from the oxidation of sulfur in fuel, the level of $SO_2$ in industrial areas can be effectively managed by optimizing the allocation of fuels: the fuel should be allocated to each industries so as to achieve the air quality goal in the area with minimum fuel cost. The solution for this can be by solved using linear programming technique incorporated with the Gaussian dispersion equation. When this method was applied in Ulsan Industrial Complex, 39.3% of fuel expense could be saved compared with the present uniform fuel policy. With this method, bituminous coal generally was allocated to big emission sources such as power plants or to industries sparsely located in remote areas, and LPG or low-sulfur oils to small or medium-size sources in dense indurstrial aras. However, the particulates emission will increase with this policy, because it maximizes the use of coal within the limit to achieve the air quality goal in the area.

  • PDF

Experimental and Numerical Study of Low NOx Multi-Staged Burner in the Test Combustor (시험용 연소로에서의 다단 저 NOx 버너의 실험 및 수치적 연구)

  • Choi, Yun-Ki;Kang, Kyung-Tae;Lim, Ki-Suk;Ko, Dong-Wan;Kim, Yong-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1339-1347
    • /
    • 2004
  • Development of the low NOx heating boiler was strongly asked due to severe air pollution and the large number of boilers in korea. Compactness of the commercial boiler was also important because of low manufacturing cost and easy installation. In this study. newly developed compact low NOx burner, using turbulent gas diffusion combustion with multi-staged air supplies and multiple fuel nozzles, was investigated. Comparison study of the new burner was performed between experimental results and computational analysis. Commercial computational fluid dynamic(CFD) program named CFX-5.6 was used for numerical analysis of the low NOx burner inside the test combustor. Comparisons of experiment data and numerical result were performed under various equivalence ratio and fuel flow rate.

A study on the monitoring of high-density fine particulate matters using W-station: Case of Jeju island (W-Station을 활용한 고밀도 초미세먼지 모니터링 연구: 제주도 사례)

  • Lee, Jong-Won;Park, Moon-Soo;Won, Wan-Sik;Son, Seok-Woo
    • Particle and aerosol research
    • /
    • v.16 no.2
    • /
    • pp.31-47
    • /
    • 2020
  • Although interest in air quality has increased due to the frequent occurrence of high-concentration fine particulate matter recently, the official fine particulate matter measuring network has failed to provide spatial detailed air quality information. This is because current measurement equipment has a high cost of installation and maintenance, which limits the composition of the measuring network at high resolution. To compensate for the limitations of the current official measuring network, this study constructed a spatial high density measuring network using the fine particulate matter simple measuring device developed by Observer, W-Station. W-Station installed 48 units on Jeju Island and measured PM2.5 for six months. The data collected in W-Station were corrected by applying the first regression equation for each section, and these measurements were compared and analyzed based on the official measurements installed in Jeju Island. As a result, the time series of PM2.5 concentrations measured in W-Station showed concentration characteristics similar to those of the environmental pollution measuring network. In particular, the results of comparing the measurements of W-Station within a 2 km radius of the reference station and the reference station showed that the coefficient of determination (R2) was 0.79, 0.81, 0.67, respectively. In addition, for W-Station within a 1 km radius, the coefficient of determination was 0.85, 0.82, 0.68, respectively, showing slightly higher correlation. In addition, the local concentration deviation of some regions could be confirmed through 48 high density measuring networks. These results show that if a network of measurements is constructed with adequate spatial distribution using a number of simple meters with a certain degree of proven performance, the measurements are effective in monitoring local air quality and can be fully utilized to supplement or replace formal measurements.

An Experimental Study on the Optimization of Performance Parameter for Membrane Based Dehumidification and Air Conditioning System (분리막 제습공조 시스템의 성능변수 최적화를 위한 실험적 연구)

  • Jang, Jeachul;Kang, Eun-Chul;Jeong, Siyoung;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.75-80
    • /
    • 2016
  • There are three types of dehumidification systems : refrigeration dehumidification method, desiccant dehumidification method and hybrid dehumidification method. The first method involves removing moisture by condensation below the dew point, the second method involves absorption by a desiccant material and the last is an integration method. However, the refrigeration dehumidification system consumes too much power and controlling the humidity ratio is difficult. The desiccant dehumidification system uses less power but it has problems of environmental pollution. The hybrid dehumidification system has the disadvantage of a high initial cost. On the other hand, the energy consumption of the membrane based dehumidification system is lower than for the refrigeration dehumidification system. Also, it is an environmentally friendly technology. In this study, the performance parameters are evaluated for the dehumidification system using a hollow fiber membrane. Available area, duct side dry-bulb temperature, sweep gas flux (flow rate) and LMPD (Log Mean Pressure Difference) were used as the performance parameters.

A Study on the Early Fire Detection by Using Multi-Gas Sensor (다중가스센서를 이용한 화재의 조기검출에 대한 연구)

  • Cho, Si Hyung;Jang, Hyang Won;Jeon, Jin Wook;Choi, Seok Im;Kim, Sun Gyu;Jiang, Zhongwei;Choi, Samjin;Park, Chan Won
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.342-348
    • /
    • 2014
  • This paper introduced a novel multi-gas sensor detector with simple signal processing algorithm. This device was evaluated by investigating the characteristics of combustible materials using fire-generated smell and smoke. Plural sensors including TGS821, TGS2442, and TGS260X were equipped to detect carbon monoxide, hydrogen gas, and gaseous air contaminants which exist in cigarette smoke, respectively. Signal processing algorithm based on the difference of response times in fire-generated gases was implemented with early and accurately fire detection from multiple gas sensing signals. All fire experiments were performed in a virtual fire chamber. The cigarette, cotton fiber, hair, polyester fiber, nylon fiber, paper, and bread were used as a combustible material. This analyzing software and sensor controlling algorithm were embedded into 8-bit micro-controller. Also the detected multiple gas sensor signals were simultaneously transferred to the personnel computer. The results showed that the air pollution detecting sensor could be used as an efficient sensor for a fire detector which showed high sensitivity in volatile organic compounds. The proposed detecting algorithm may give more information to us compared to the conventional method for determining a threshold value. A fire detecting device with a multi-sensor is likely to be a practical and commercial technology, which can be used for domestic and office environment as well as has a comparatively low cost and high efficiency compared to the conventional device.

A Study of Environment Monitoring System based on Sensor Network (센서 네트워크를 이용한 실내 공기질 관리 및 제어에 관한 연구)

  • Kim, Ki-Tae;Kim, Dong-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.389-392
    • /
    • 2010
  • The problem for the air pollution in the office or the indoor except a specific working area is the continuously issue since the human beings have lived in the dwelling facilities. Measures for that problem are urgently needed. It's possible to solve for the freshair of outside with enough ventilation but that is the awkward situation to be managed by person. It's feasible to supervison and control easily if you use to sensor network under the network. It works out to sense, storage, process, deliver every kind of appliances and environmental information from the stucktags and sensors. And it is possible to utilize to measure and monitor about the place of environmental pollution which is difficult for human to install. It's studied constantly since it be able to compose easily more subminiature, low-power, low-cost than previous one. And also it spotlights an important field of study, graft the green IT and IT of which the environment and IT unite stragically onto the Network. This study compose a IAQM(Indoor Air Quality Management) under the network, suggest the application of supervision and control.

  • PDF

A Study on Logistics Cost Analysis for Autonomous Cargo Truck (무인화물차의 물류비용 분석에 관한 연구)

  • Kim, Hwan-Seong;Park, Jin-Soon;Jo, Min-Ji
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2016.05a
    • /
    • pp.207-208
    • /
    • 2016
  • By according to increase the research for autonomous vehicle in automobile industries, the efficient of autonomous cargo truck instead of conventional driver cargo truck will be analyzed in logistics areas. The inland transportation has been serious problem such as traffic accident, traffic congestion in downtown, air pollution, noise and etc. even if it have a great effect to logistics industries. Especially there have to be improved its transportation schedule and sleepy driving in night which induced heavy accident in highway. In this study, the effectiveness of autonomous cargo truck will be analysed by considering the logistics cost including social effects.

  • PDF

The Economic Analysis of A Solid Refuse Fuel (SRF) Project in the Urban Area (가연성 폐기물 고형연료(SRF) 사업의 경제성 분석)

  • Jang, EunMi;Cho, Yongsung
    • Journal of Climate Change Research
    • /
    • v.4 no.3
    • /
    • pp.245-254
    • /
    • 2013
  • Korea government promote renewable energy as the core of their energy matrix to break the dependence and reduce greenhouse effects. This study analyzes the economic assessment of Solid Refuse Fuel project in urban area, considering the marginal external costs of air pollution in this area. Assessment index defined as costs (i.e., construction cost, operation cost) and benefit (margin, external cost) data which is located in Sudokwon landfill site. The result indicates that cost-benefit analysis of SRF is calculated as 1.0. In addition, SRF project is very sensitive about electric power selling price, operating cost and labor cost according to inflation rates. This study shows that the sustainability of SRF project is required the government financial support like investment funds as well as policy support. Variability analysis of SRF economic assessment due to renewable energy can be used for making policies in various fields such as waste and public energy field.