• Title/Summary/Keyword: Air Hygiene

Search Result 410, Processing Time 0.03 seconds

Assessment of Indoor and Outdoor Air Quality through Determination of Microorganism (미생물을 이용한 일부 병원, 가정 및 일반 대기질의 평가)

  • Ha, Kwon Cheol;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.73-81
    • /
    • 1991
  • To assess biological air quality, concentrations of viable airborne microbes were determined in hospital home and outdoor air from August 25 to October 18, 1990. Bacteria, fungi and thermophilic bacteria were sampled using gravitational and suctional sampling method. In bacteria groups, the Staphylococcus spp. was identified by microscopic examination and biochemical tests. Results of the study are as follows. 1. Results using the gravitational sampling method indicated that average numbers of airborne microbes in hospital home and outdoor air were 21.5, 12.2 and 17.6 CFU/plate, respectively. These levels are well within an appropriate standard of 50 CFU/plate suggested by Endo. 2. Results using the suctional sampling method indicated that total airborne microbe concentrations in hospital, home and outdoor air were 1,998, 1,363 and $1,880CFU/m^3$, respectively. All of the results were within the recommended remedial action level, $10,000CFU/m^3$ of the American Conference of Governmental Industrial Hygienists(ACGIH). 3. Concentration of thermophilic bacteria in hospital and outdoor air were 79 and $111CFU/m^3$, respectively. Thermophilic bacteria were not detected in the home air. These results were within the remedial action level, $500CFU/m^3$. 4. Concentrations of Gram negative bacilli in holpital home and outdoor air were 20.3, 23.6 and $16.8CFU/m^3$, respectively. all were within the remedial action level, $500CFU/m^3$, recommended by ACGIH. 5. Concentrations of Staphylococcus spp. in hospital, home and outdoor air were 34.8, 14.7, and $22.4CFU/m^3$. respectively. all were within the remedial action level, $75CFU/m^3$, recommended by ACGIH. The percentages of Staphylococcus spp. in total bacteria in hospital, home and outdoor air were 19.0, 10.2 and 14.5%, respectively.

  • PDF

Environmental Working Status of Mercury using Industries in Korea (수은 취급사업장 작업환경 실태에 관한 조사연구)

  • Chung, Mu Soo;Hwang, Kyu Yoon;Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.128-135
    • /
    • 1991
  • To obtain the basic information of environmental working status in mercury industries in Korea, 26 mercury industries were investigated with mercury concentration in air and various factors affecting on workplace environment. The results were as follows : 1. The mean air concentration of mercury was $0.046{\pm}0.035mg/m^3$ in 26 mercury industries. 2. The highest mean air concentration of mercury among 26 mercury industries classified by type of product was found in sodium hydroxide manufacturing industries ($0.054{\pm}0.020mg/m^3$) and the lowest mean was found in mercury battery manufacturing industries ($0.003{\pm}0.002mg/m^3$). 3. While the highest' mean air concentration of mercury was found in manual method ($0.061{\pm}0.041mg/m^3$) among the types of operation method, lowest one was found in automatic method ($0.035{\pm}0.025mg/m^3$). 4. While the mean air concentration of mercury was $0.023{\pm}0.018mg/m^3$ in good clean status of workshop, the mean air concentration of mercury in bad clean status was $0.06{\pm}0.033mg/m^3$. Among various factors affecting on th e air concentration of mercury, clean Iiness of workshop showed statistically significant difference with air concentration of mercury, and automation of workshop and local exhaust ventitlation also played important role in control the air concentration of mercury in the working environment.

  • PDF

A Study on Factors Affecting Airborne Fume Composition and Concentration in Welding Process (용접공정에서 발생된 공기중 흄의 조성과 농도에 영향을 미치는 요인에 관한 연구)

  • Shin, Yong Chul;Yi, Gwang Yong;Park, Seung Hyun;Lee, Na Roo;Jeong, Jee Yeon;Park, Jung Keun;Oh, Se Min;Moon, Young Hahn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.181-195
    • /
    • 1997
  • The purpose of this study was to investigate factors affecting the composition and concentrations of fumes generated from various types of welding processes. The results are as follows. 1. Iron(Fe), zinc(Zn) and manganese(Mn) were predominant in Welding fumes. The Fe content in total fumes was 25.5% in coated electrode and 28.2% in $CO_2$ are welding, and the Zn content was 4.5% and 9.1%, respectively, and the Mn was 3.6% and 7.8%, respectively. 2. It was found that the important factors determining composition and concentration of fumes were type of industries, type of welding processes, type and composition of electrodes, composition of base metals, confinement of workplaces or condition of ventilation, work intensity, coated metals such as lead and Zn in paint. 3. The Mn content in airborne fumes was highly correlated with that of electrode(r=0.77, p<0.01) and was about 4 times higher than that in electrodes or base metals. The results lindicate that Mn is well evaporated into air during welding. The higher vapor pressure of Mn may explain this phenomenon. 4. the airborne total fume concentrations were significantly different among types of industries(p<0.001). The airborne total fume concentration was higher in order of sleel-structure manufacturing($GM=15.1mg/m^3$), shipbuilding($GM=13.2mg/m^3$), automobile-component manufacturing ($GM=7.8mg/m^3$) and automobile assembling industry($GM=3.0mg/m^3$) 5. The airbone total fume concentration was 6 times higher in $CO_2$ welding than in coated electrode welding, and approximately 3 times higher in confined area than in open area, in steel-structure manufacturing industry. 6. The concentration of welding fume outside welding helmet was about 2 times higher than that inside it. It is recommened that air sampling be done inside helmet to evaulate worker's exposure accurately, for it has an outstanding effect on reducing worker exposure to fumes and other contaminants.

  • PDF

A Study on the Standards of Volatile Organic Compounds in Indoor Air of Office (사무실 실내공기중 휘발성유기화합물의 기준설정에 관한 연구)

  • Kim, Yoon-Shin;Lee, Cheol-Min;Roh, Young-Man;Lee, So-Dam;Sohn, Jong-Ryeul;Kim, Seok-Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.413-427
    • /
    • 2006
  • It is necessary to study and develop guidelines for providing comfort and health indoor air quality for office workers since air-tight envelope system of current office building may cause poor indoor air quality. The purpose of this study is to propose guideline for volatile organic compounds in office base on the field study, human health risk assessment and cost-benefit analysis. The field study was conducted to survey the concentrations of volatile organic compounds in indoor air of 69 offices from June to September, 2005 in Seoul and Gyeonggi-do. The rate of excess to guideline of volatile organic compounds in indoor air of new apartment on the Ministry of Environment in Korea(MOE) was surveyed 37.6% for benzene, 6.8% for toluene, and 1.5% for ethylbenzene. As the result of human health risk assessment, mean cancer risk did not exceed 10-6 which is guideline of US.EPA. Also, total hazard index did not exceed 1 which is guideline of US.EPA. Through the cost-benefit analysis of angle on the social-economics to verify the necessary to establish the standards of volatile organic compounds for improvement and development of indoor air quality in office, the present value of benefit was higher than the present value of cost. With the above considerations in mind, it is suggested that the field study for indoor air quality in offices should be expanded and human health risk assessment and cost-benefit analysis be performed th offer scientific data for decision-making of policy for improvement and management of indoor air quality in office.

Possibility of Spreading Infectious Diseases by Droplets Generated from Semiconductor Fabrication Process (반도체 FAB의 비말에 의한 감염병 전파 가능성 연구)

  • Oh, Kun-Hwan;Kim, Ki-Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.111-115
    • /
    • 2022
  • Objectives: The purpose of this study is to verify whether droplet-induced propagation, the main route of infectious diseases such as COVID-19, can occur in semiconductor FAB (Fabrication), based on research results on general droplet propagation. Methods: Through data surveys droplet propagation was modeled through simulation and experimental case analysis according to general (without mask) and mask-wearing conditions, and the risk of droplet propagation was inferred by reflecting semiconductor FAB operation conditions (air current, air conditioning system, humidity, filter conditions). Results: Based on the results investigated to predict the possibility of spreading infectious diseases in semiconductor FAB, the total amount of droplet propagation (concentration), propagation distance, and virus life in FAB were inferred by reflecting the management parameter of semiconductor FAB. Conclusions: The total amount(concentration) of droplet propagation in the semiconductor fab is most affected by the presence or absence of wearing a mask and the line air dilution rate has some influence. when worn it spreads within 0.35~1m, and since the humidity is constant the virus can survive in the air for up to 3 hours. as a result the semiconductor fab is judged to be and effective space to block virus propagation due to the special environmental condition of a clean room.

Performance of Hygiene Management according to Capacity and Food Cost of Foodservice in Kindergartens (시설 규모 및 급식비에 따른 유치원 급식소 위생 관리 수행도)

  • Kim, Ok-Sun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.24 no.5
    • /
    • pp.680-690
    • /
    • 2014
  • This study investigated the performance of hygiene management according to the capacity and food cost of foodservice in kindergartens as a measure of kindergartens foodservice hygiene management. Dietitians from the education office visited 50 kindergartens under the control of Dongbu District Office of Education during January, 2011. Kindergartens were 11 public and 39 private institutions. Over half of kindergartens (n=27) provided foodservice to 50~99 children. About 21 kindergartens had a foodservice cost per student per day of 2,000 won. Regarding personal hygiene, 'whether to wear an accessory or have a manicure' showed the best performance. 'Whether to have their health examined once every 6 months or keep their health records in 2 years' was rarely performed. For food materials, 'whether to buy food appropriate for the quality control standard of food materials' showed the highest performance. The highest performances for storage management of food materials and handling of food was 'whether to store goods within butlery at intervals more than 30 cm from the ground' and 'whether to heat and cook food more than $74^{\circ}C$', respectively. The highest performance for distribution of food and management of facilities was 'the hygienic management of cooking tools and facilities' and 'the proper installation of air-conditioning, heating and ventilation facilities', respectively. The results of this study show that capacity and food cost had the strongest effects on performance of personal hygiene. Especially, smaller facility size could increase performance of foodservice management.

Exposures of Organic Solvent Mixtures to Rotogravure Printing Workers (일부 그라비아 인쇄업 근로자의 혼합 유기용제 노출농도)

  • Choi, Ho-Chun;Kim, Kangyoon;An, Sun-Hee;Chung, Kyou-Chull
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.71-85
    • /
    • 1997
  • The purpose of this study was to evaluate concentrations of organic solvent mixtures in air of rotogravure printing workplaces. Qualitative and quantitative analysis of organic solvents contained in the gravure inks used at rotogravure factories had been done. The results obtained were as follows: 1. The gravure inks mainly consist of toluene, methyl ethyl ketone(MEK), and ethyl acetate(EA), and traces of isopropyl alcohol(IPA), xylene, 2-butanol, cyclohexane, cellosolve etc were also contained in them. 2. Thinner used as a diluent consist of toluene, MEK, and EA. 3. Geometric mean concentration of toluene in ambient air were 23.81 ppm at gravure printing of packing material, 42.10 ppm at gravure printing of wallpaper, 16.95 ppm at gravure printing of plastic bottle for beverage and 4.31 ppm at gravure printing of plywood printing or floor covering. Concentrations of toluene in ambient air showed statistically significant difference between types of printing. 4. Concentrations of MEK in ambient air were 12.43 ppm at gravure printing of packing material, 5.47 ppm at gravure printing of wallpaper, 16.78 ppm at gravure printing of plastic bottle for beverage and 16.44 ppm at gravure printing of plywood printing or floor covering. MEK concentrations in ambient air showed no significant difference. 5. Conentrations of EA were 14.30 ppm at gravure printing of packing material, 1.92 ppm at gravure printing of wallpaper and 21.12 ppm at gravure printing of plywood printing or floor covering. EA concentrations in ambient air shown significant difference. 6. Percentage of the workplaces where the ambient air concentration of organic solvent mixtures exceeded the Korean Permissble Exposure Level(KPEL) amounted to 18.03%. 7. Toluene concentrations in ambient air of rotogravure printing workplaces ranged from 0.69 to 156.02 ppm and urinary hippuric acid excretion ranged from 0.10 to $1.32g/{\ell}$.

  • PDF

An Experimental Study for the Improvement of Ventilation Conditions and Effectiveness in the Manufacturing Industry by Increasing the Mixing Factor (K-Factor) (혼합계수(K-Factor) 증가에 따른 사업장의 환기 조건 및 효율 개선에 관한 연구)

  • Lee, Yun-ho;Lee, Seokwon;Lee, Kyoungho;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.343-350
    • /
    • 2019
  • Objectives: This study aims to identify whether ventilation conditions and their effectiveness can be significantly improved in an experimental chamber by increasing the mixing factor (K-Factor). Methods: In a chamber with a volume of $1m^3$, air velocity was measured at six different points with four roof fans in the upper part of the chamber being operated in order. The impact of the ventilation conditions was analyzed when the flow rates were increasing and the first inlet of the chamber was either open or closed. Smoke patterns were also observed at four corner points where ventilation was limited. Kruskal Wallis and Mann-Whitney tests were performed to compare air velocities measured in the chamber. Results: The air velocities measured at only the third point increased significantly from $0.03{\pm}0.03m/s$ (door open) and $0.05{\pm}0.06m/s$ (door closed) with two fans, $0.08{\pm}0.08m/s$ with three fans, and $0.09{\pm}0.09m/s$ with four fans operating (p<0.05). However, air velocities at the four corner points did not significantly increase. Smoke patters also showed that the open inlet of the chamber had no effect on improvement of ventilation conditions and effectiveness. Conclusions: In this study, the air velocities at six points in the chamber did not significantly increase despite the increase in the mixing factor and flow rates of ventilation in the controlled environment. Therefore, the inflow of outdoor air throughout an open inlet and installation of a forced ventilation system can potentially increase the indoor air velocity and improve ventilation condition without an increase in the mixing factor.

The Effects of the Superimposed Fabrics on the Air-Permeability (직물의 중첩이 통기성에 미치는 영향)

  • Chung Jung-Sook;Chung Un-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.11 no.1
    • /
    • pp.21-28
    • /
    • 1987
  • Since the air permeabilities are closely connected with clothing hygiene, air permeabilities required to optimize dressing were studied and measured the air permeabilities that take air layers among fabrics into account. The thickness of air layers were controlled from 3mm to 24mm, and the numbers of air layers were made from one layer to three layers. The samples used were selected in casual wears in spring and autumn. The results obtained are as follows; 1. Specific air permeabilities of superimposed fabrics decreased gradually according to the increase of superimposed number. 2. Specific air permeabilities of the same kind of fabrics increased at first and later decreased by the increase of intervals when the fabrics are superimposed at regular intervals, and those of the different kind of fabrics decreased. 3. Specific air permeabilities of the different kind of fabrics decreased to the 18mm of total thickness in air layers and increased later.

  • PDF

Impact of working environment on the subjective health symptoms in the dental hygienists (치과위생사의 직무환경이 건강자각증상에 미치는 영향)

  • Jeong, Ka-Young;Cho, Hye-Eun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.539-546
    • /
    • 2015
  • Objectives: The purpose of the study is to investigate the impact of working environment on the subjective health symptoms in the dental hygienists. Methods: The subjects were 220 dental hygienists in Gwangju and Jeonnam. A self-reported questionnaire was completed from September 9 to 22, 2012. The questionnaire was adapted and modified from building symptom index of workers in large buildings by O. The questionnaire consisted of eight questions of the general characteristics of the subjects, 19 questions of working environment and job satisfaction, nine questions of working environment characteristics, and six questions of subjective health symptoms. The questionnaire was measured by Likert 4 scale. Cronbach's alpha in this study was 0.826. Except incomplete answers, 192 data were analyzed using SPSS 19.0 program including t-test, ANOVA, and multiple regression. Results: The health symptoms were statistically and significantly different in glasses wearer and contact lens wearer, working hour satisfaction, and indoor environment(p<0.05). The subjective health symptoms were statistically different from the salary satisfaction, human relations satisfaction, office air environment, indoor environmental awareness score(p<0.05). Conclusions: It is necessary to improve the pleasant indoor working environment by providing the efficient working environment for the health care providers.