공조설비용 고장진단시스템의 실시간 진단실험 (The On-Line Diagnostic Test of Fault Diagnosis System for Air Handling Unit)

  • 소정훈;유승신;경남호;신기석
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.787-795
    • /
    • 2001
  • An experimentation on the on-line fault detection and diagnosis(FDD) system has been performed with HVAC system in he experimental building constructed inside the large scale environmental chamber. Personal computer with a home-made FDD program by pattern recognition method utilizing artificial neural network was connected on-line via Ether-net TCP/IP to the supervisory control server for HVAC system. The FDD program monitored the HVAC system by 1 minuted interval. The results showed that he FDD program detected the sudden or abrupt faults such s those in fans, sensors and heater, etc.

  • PDF

축류팬의 성능 평가 및 주변 유동 특성 (Performance and Flow Characteristics of Axial Fan)

  • 김재원;정윤영
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.972-981
    • /
    • 2000
  • Comprehensive work is done for flows by an axial fan by experimental research. The present model fan is used for air handling device for out-door unit of an air conditioner in home appliance. PIV(Particle Image Velocimetry) system and wind tunnel are adopted for measurements of flows and performance evaluation, respectively. Major experimental conditions are the installation depth of a fan into a bellmouth of it. Optimal position of a fan in an inlet guide tube is observed by examination of fan-performance and flows in both upstream and downstream of the fan. Consequently, in the case of the fan inserted in half depth into the inlet tube, the efficiency of fan shows its maximum value and flow patterns is also streamlined.

  • PDF

공기조화기내 메쉬삽입 물-공기 직접접촉의 열전달 특성 연구 (Air Handling Unit Utilizing Water/Air Direct Contact Heat Exchanger with Mesh)

  • 전용한;김종윤;김남진;서태범;김종보
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.75-80
    • /
    • 2008
  • The objective of this research was to investigate the enhancement of heat transfer by mesh in water/air direct contact air conditioning system. Mesh is inserted as a turbulent promoter in front of the water injection nozzle. The heat transfer characteristics with and without mesh and the effect of the number of inserted mesh and mesh porosity size have been studied experimentally. Inserted mesh improves heat transfer efficiency compared to non~inserted mesh system and heat transfer efficiency increased as the number of mesh is increased. Meanwhile, heat transfer efficiency decreased as the porosity of the mesh is increased. With inserted mesh, inlet and outlet temperature difference of air increased more than 50%. Heat exchange time of water/air to reach the 100% humidity decreased less than 30%. This result shows inserted mesh can enhance the performance of the water/air direct contact air conditioning system.

공조 시스템의 센서 고장 검증 기술 (Sensor Validation for an Air Handling Unit)

  • 이원용;신동열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.612-614
    • /
    • 1999
  • In order to improve the operational reliability, it is necessary to validate the measured sensor data, isolate any failed sensor and recover the failed critical measurement. This paper describes the use of estimating equation to identify failed sensors and to recover the feedback signal for control purpose when the sensor measurement is determined to be erroneous Simulation results show that the proposed sensor validation scheme can adequately identify the failed sensor and provide reasonable estimates for control purposes.

  • PDF

유동해석을 사용한 공조기 입구형상의 최적설계 (Optimal inlet shape design of air handling unit using CFD)

  • 최영석;이용갑;주종일
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2001년도 춘계학술대회 발표논문집
    • /
    • pp.108-112
    • /
    • 2001
  • 본 논문에서는 전산유체해석 기법을 이용하여 저소음ㆍ고효율 공조기의 입구형상에 대한 유동해석을 하였다. 공조기 입구형상을 결정하는 여러 설계변수가 입구와 출구의 유동조건과 유로의 압력손실에 미치는 영향을 평가하였다. 이를 바탕으로 입구와 출구유동의 균일성과 압력손실의 최소화를 만족하는 최적의 설계 변수를 결정하여 공조기의 최적설계를 달성하였다.

AHU 토출온도에 따른 일반 공조시스템의 에너지 소비량 및 실내 온열환경 분석 (Energy Consumption and Thermal Comfort Assessment of Conventional Forced-air System According to AHU Discharge Air Temperature)

  • 김민지;연상훈;이광호
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.51-57
    • /
    • 2018
  • Recently, global warming has been a serious issue on the worldwide, and the importance of energy conservation is increasing. In most buildings, energy consumption increases due to cooling, heating, and ventilation. Because of these issues, researches have been carried out to reduce building energy. However, in most conventional forced-air system, the guidelines for the Air Handling Unit (AHU) discharge air temperature are not fully established. The purpose of this study is to assess the impact of AHU discharge air temperature, which is one of the important control variables, on the overall energy consumption and thermal comfort characteristics by modeling conventional forced-air system using EnergyPlus. In addition, recommendations for energy reduction in conventional AHU is provided.

열교환기를 사용한 냉각/재가열 장치의 에너지 절감에 관한 연구 (A Study on the Energy Saving of Cooling/Reheating System Using Heat Exchanger)

  • 김진혁;유성연;최양규
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.482-491
    • /
    • 2010
  • In conventional air-handling units, when the circulated air from the air-conditioned space pass through the cooling coil, the air is over-cooled to eliminate the moisture as well as to decrease the temperature. The purpose of this study is to estimate the thermal performance and energy saving of the cooling/reheating system using heat exchanger which can save both cooling energy and reheating energy by exchanging heat between the cooled air and reheated air. The energy balance equations to estimate the state of the air for each components were provided and the heat transfer rates and the energy saving rates for the system were calculated from the equations. The results showed that the energy saving was up to 40% under present conditions, and saving rates were significantly affected by the air velocity, inlet conditions and the effectiveness of heat exchanger.

공기조화기내 메쉬삽입 물-공기 직접접촉의 열전달 특성 연구 (Air handling unit utilizing water/air direct contact heat exchanger with mesh)

  • 전용한;문명훈;김종윤;김남진;서태범;김종보
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1161-1166
    • /
    • 2008
  • The objective of this research was to investigate the enhancement of heat transfer by mesh in water/air direct contact air conditioning system. Mesh is inserted as a turbulent promoter in front of the water injection nozzle. The heat transfer characteristics with and without mesh and the effect of the number of inserted mesh and mesh porosity size have been studied experimentally. Inserted mesh improves heat transfer efficiency compared to non-inserted mesh system and heat transfer efficiency increased as the number of mesh is increased. Meanwhile, heat transfer efficiency decreased as the porosity of the mesh is increased. With inserted mesh, inlet and outlet temperature difference of air increased more than 50%. Heat exchange time of water/air to reach the 100% humidity decreased less than 30%. This result shows inserted mesh can enhance the performance of the water/air direct contact air conditioning system.

  • PDF

데이터센터에 적용된 외기도입 냉방시스템에서 필터유형별 에너지 소비량 변화 (Energy Consumption Analysis based on Filter Differential Pressure when Adopting an Air-side Economizer System for a Data Center)

  • 박성현;서장후;정용호;장현재;황석호
    • 설비공학논문집
    • /
    • 제25권7호
    • /
    • pp.371-376
    • /
    • 2013
  • Recently, many studies related to reducing the energy consumption in data centers have been conducted. These studies have mainly focused on the air intake and exhaust system of a computer room air handling unit (CRAH) in the server room, diffuser type, suppression and discharge of the heat generated from the server, and the air-side economizer system. In this study, the energy consumption of the conventional central chilled water cooling system is compared with the energy consumption of the air-side economizer system. We also examined how changes of differential pressure by each filter have influenced energy consumption, using the power usage effectiveness (PUE). Results show that the PUE was improved, and energy consumption decreased, by applying the air-side economizer system.

정풍량 공조시스템의 고장검출 및 진단 시뮬레이션 (Fault Detection and Diagnosis Simulation for CAV AHU System)

  • 한동원;장영수;김서영;김용찬
    • 설비공학논문집
    • /
    • 제22권10호
    • /
    • pp.687-696
    • /
    • 2010
  • In this study, FDD algorithm was developed using the normalized distance method and general pattern classifier method that can be applied to constant air volume air handling unit(CAV AHU) system. The simulation model using TRNSYS and EES was developed in order to obtain characteristic data of CAV AHU system under the normal and the faulty operation. Sensitivity analysis of fault detection was carried out with respect to fault progress. When differential pressure of mixed air filter increased by more than about 105 pascal, FDD algorithm was able to detect the fault. The return air temperature is very important measurement parameter controlling cooling capacity. Therefore, it is important to detect measurement error of the return air temperature. Measurement error of the return air temperature sensor can be detected at below $1.2^{\circ}C$ by FDD algorithm. FDD algorithm developed in this study was found to indicate each failure modes accurately.