• Title/Summary/Keyword: Air Gap Winding

Search Result 104, Processing Time 0.021 seconds

An Analysis on the Characteristics of the Contact-less Power Supply (무접점 전원장치의 특성분석)

  • Lee, Hyun-Kwan;Lee, Gi-Sik;Chung, Bong-Geun;Kang, Sung-In;Kong, Young-Su;Kim, Eun-Soo;Kim, Yoon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.919-922
    • /
    • 2006
  • Comparing with the conventional transformer without the air gap, a contact-less transformer with the large air-gap (4.8cm) between the long primary winding and the secondary winding has the increased leakage inductance and the reduced magnetizing inductance. By the increased leakage inductance and the reduced magnetizing inductance on the primary of the contact-less transformer, a good deal of the primary current circulates through magnetizing inductance, which results in a massive loss in contact-less power supply (CPS). In this paper, the efficiency characteristics of the contact-less power supply using a series resonant converter is analyzed and simulated. The results are verified on the simulation based on the theoretical analysis and the 1.8kW experimental prototype.

  • PDF

Development of Shorted Turn Sensor for Generator Rotor (발전기 회전자 층간단락 감지기 국산화 개발)

  • Lee, Young-Jun;Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.195-197
    • /
    • 2001
  • The shorted-turn sensor for generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a shorted-turn test was performed at the Seoinchon & Sininchon combined cycle power plant on gas turbine generator. This sensor will be used as a detecting of shorted-turn for generator's field winding.

  • PDF

Research on Oscillation Character of Six-Phase Fractional-Slot Concentrated-Winding Permanent Motor with Different Slot-Pole Match

  • Qiao, Ming-zhong;Zhu, Yong-xin;Liang, Jing-hui;Li, Geng
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1693-1699
    • /
    • 2016
  • The oscillation character of permanent magnetic motor is highly related to its slot-pole match. By calculating air-gap magnet field and radial electromagnetic force of 6-phase fractional-slot concentrated-winding permanent magnetic motor with slot-pole match of 48/44, 48/46, 48/50 and 48/52 under no load and load status, oscillation character of permanent magnetic motor is analyzed. A 20kW prototype with 48 slots and 44 poles is designed. With many sensors attaching to the corresponding parts, oscillatory acceleration is measured, and spectrum of oscillation frequency is recorded as well. The experiment results give proof to the analysis method for permanent magnetic motor oscillation in this paper.

Development of Shorted-Turn Sensor for Generator Rotor (발전기 계자의 층간단락 감지기 개발)

  • Lee, Young-Jun;Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1765-1767
    • /
    • 2001
  • The shorted-turn sensor for generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a shorted-turn test was performed at the Seoinchon combined cycle power plant on gas turbine generator. This sensor will be used as a detecting of shorted-turn for generator's field winding.

  • PDF

A Study of On-line Monitoring System for a KEPCO Pumped Storage Generator/Motor

  • Kim Hee-Dong;Ju Young-Ho;Kim Yong-Joo;Cho Kyu-Bock
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2006
  • An on-line diagnostic test has been studied and performed for the pumped storage generator/motor. This study aims at reducing the diagnostic cost, minimizing the technical dependency on third party manufactures. Further design of on-line diagnostic system such as shorted-turn of rotor winding, partial discharge (PD) of stator winding and air-gap between stator and rotor for pumped storage generator/motor has been verified. In addition, it needs to be validated on site performance of the developed continuous on-line monitoring system for corresponding tasks for the improvement of the availability & reliability during operation.

The Travelling Field of Two phase Linear Induction Motor (2상 Linear Induction Motor의 이동자계)

  • 이윤종;임달호
    • 전기의세계
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 1970
  • The foundation for the theoretical establishment of the linear motor lies in the investigation of the magnetic flux distribution in its airgaps. Generally speaking, the linear motor is similar, in the principle of its operation, to the general induction motor. However, there are great differences in the aspects of its structure and characteristics, especially, in the fact that the formation of its travelling magnetic field depends on the method of its winding. This paper is written in order to introduce the method of calculating the air gap magnetic flux distribution on the basis of its ampere-conductor in the case that 2 phase winding is applied on its open magnetic circuit iron core, and to present the results of investigation of the pulsation in its travelling fields. the first and second example of winding show the case of travelling magnetic field with the constant amplitude except the end region. The third example deals with the configuration of coil-side displaced outside the core and which produce the increased flux density at the ends, but, on the contrary, forms the pulsated travelling field.

  • PDF

Electromotive Force Characteristics of Current Transformer According to the Magnetic Properties of Ferromagnetic Core

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.1
    • /
    • pp.37-41
    • /
    • 2015
  • The most common structure of the current transformer (CT) consists of a length of wire wrapped many times around a silicon steel ring passed over the circuit being measured. Therefore, the primary circuit of CT consists of a single turn of the conductor, with a secondary circuit of many tens or hundreds of turns. The primary winding may be a permanent part of the current transformer, with a heavy copper bar to carry the current through the magnetic core. However, when the large current flows into a wire, it is difficult to measure its magnitude of current because the core is saturated and the core shows magnetic nonlinear characteristics. Therefore, we proposed a newly designed CT which has an air gap in the core to decrease the generated magnetic flux. Adding the air gap in the magnetic path increases the total magnetic reluctance against the same magnetic motive force (MMF). Using a ferrite core instead of steel also causes the generation of low magnetic flux. These features can protect the magnetic saturation of the CT core compared with the steel core. This technique can help the design of the CT to obtain a special shape and size.

A Study on Design and Manufacture of Slotless Outer Rotor BLDC Motor for a Vehicle Blower (자동차 송풍장치용 Slotless Outer Rotor BLDC 모터 설계 및 제작에 관한 연구)

  • Hyon-Jang Lee;Hee-Seok Jeong;Sun-Ho Cho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.5
    • /
    • pp.827-834
    • /
    • 2023
  • In this paper, a slotless outer rotor BLDC motor for a vehicle blower was designed and manufactured to improve the disadvantages of general motors. The proposed motor solves the noise caused by mechanical friction of DC motor during rotation by removing the brush, Also, slotless air-gap windings are used to improve cogging torque by BLDC motor slots. Then, the motor has a structure in which a magnet is attached to the external rotor and rotates simultaneously with the internal rotor, there is no change in magnetic flux. Therefore, it has high efficiency by fundamentally reducing iron loss.

Magnetic Field Calculation and Multi-objective Optimization of Axial Flux Permanent Magnet Generator with Coreless Stator Windings

  • Zhu, Jun;Li, Shaolong;Song, Dandan;Han, Qiaoli;Li, guanghua
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1586-1595
    • /
    • 2018
  • For the problem that the complexity of 3-D modeling and multi parameter optimization, as well as the uncertainty of the winding factor of axial flux permanent magnet generator with coreless windings. The complex 3-D model was simplified into 2-D analytic model, and an analytical formula for the winding factor that adapting different coreless stator winding is proposed in this paper. The analytical solution for air-gap magnetic fields, no-load back EMF, electromagnetic torque, and efficiency are calculated by using this method. The multiple objective and multivariable optimization of the maximum fundamental and the minimum harmonic content of back EMF are performed by using response surface methodology. The proposed optimum design method was applied to make a generator. The generator was tested and the calculated results are compared with the proposed method, which show good agreements.

Design and Dynamic Analysis of Electromagnets for Levitation Application (부상용 전자석의 설계 및 동특성 해석)

  • Jang, Seok-Myeong;Choi, Jang-Young;Sung, So-Young;Sung, Ho-Kyoung
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.83-85
    • /
    • 2008
  • This paper deals with design and dynamic analysis of electromagnets for levitation applications. On the basis of equivalent magnetic circuit (EMC) method and 3-D finite element analysis (FEA) model, initial and detailed design for electromagnets are performed. Using the state equation for the closed-loop control, the dynamic analysis of electromagnets is also performed. Finally, this paper investigates the variation of levitation force according to current under fixed nominal air-gap, and the variation of required current according to load weight in order to maintain the nominal air-gap. From these results, the validation of design and dynamic analysis of electromagnets is confirmed. In particular, the influence of winding temperature on levitation control is discussed in detail.

  • PDF