• Title/Summary/Keyword: Air Extraction

Search Result 384, Processing Time 0.021 seconds

The Study on Pre-treatment Method of Filter for Analysing the Heavy Metals in Air Quality (대기중의 중금속 분석을 위한 여지의 전처리 방법에 관한 연구)

  • 김광래;이상칠;어수미;김민영;신재영;이재영
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.16-19
    • /
    • 2002
  • This study was carried out to establish the standardized analysis method in order to decide accurate concentrations of hazardous metals in the air. Acid decomposition method used usually was compared to microwave digestion method. Comparing results of tested background concentration in blank filter, we found that the magnitude of element concentration was Na, Ca, K, Mg, Al and Ba by order. The element concentrations of Glass fiber filter were higher than those of Quartz fiber filter, and the number of undetected components in Glass fiber filter was lower than that in Quartz fiber filter. Thus it is supposed that the concentration of background elements in Glass fiber filter was higher than those in Quartz fiber filter The extraction rate of microwave digestion method was superior to those of acid decomposition method during the test of blank filter as well as SRM of NIST. In case of the SRM of NIST, the average extraction efficiency of acid decomposition Method and microwave pretreatment is 53.8∼82.7%, 81.3∼97.1%, respectively. This result might be caused by the closed system of Microwave, which make outflow and loss of components less. Also microwave digestion method has other merits such as the minimization of time, reagents, and contamination. Furthermore, if the extraction condition, extraction time and used acids are optimized, the better results will be represented.

  • PDF

Hot Air Injection/Extraction Method for the Removal of Semi-Volatile Organic Contaminants from Soils (토양내 저휘발성 유류오염물 제거를 위한 고온공기 주입/추출기술 연구)

  • Gu Chung-Wan;Ko Seok-Oh
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.1
    • /
    • pp.6-12
    • /
    • 2005
  • Contamination of soils and groundwater by leakage of petroleum compounds from underground storage tanks (USTs) has become great environmental issues. Conventional methods such as soil vapor extraction (SVE) used for the remediation of unsaturated soils contaminated with volatile organic compounds might not be applied for the removal of semi-volatile organic compounds such as diesel fuels and PCBs, which have low volatility and high hydrophobicity. The objective of this study is to develop a hot air injection method to remove semi-volatile compounds. Additionally, operation parameters such as temperature, air flow rate, and water content are evaluated. Experimental results show that diesel ranged organics (DROs) are removed in the order of volatility of organic compounds. As expected, removal efficiency of organics is highly dependent on the temperature. It is considered that more than $90\%$ of organic contaminants whose carbon numbers range between 17 and 22 can be removed efficiently by the hot air injection-extraction method (modified SVE) over the $100^{\circ}C$. It is also found that increased air flow rate resulted in high removal rate of contaminants. However, air flow rate over 40 cc/min is not effective for the operation aspects, due to mass transfer limitation on the volatilization rate of the contaminants. The effect of the water content on the decane removal is minimal, but some components show large dependence on the removal efficiency with increasing water content.

Extensive Bilateral Subcutaneous Emphysema after Dental Treatment: Two Case Reports

  • Gyu-Beom Kwon;Chul-Hwan Kim ;Hae-Seo Park
    • Journal of Korean Dental Science
    • /
    • v.16 no.1
    • /
    • pp.80-86
    • /
    • 2023
  • We report two rare cases of extensive bilateral subcutaneous emphysema that occurred during ordinary dental procedures. An air-driven high-speed handpiece, routinely used in dental procedures may cause subcutaneous emphysema when high pressure air is introduced into the loose connective tissues below the dermal layer. The first case occurred with surgical extraction of the lower third molar. The air introduced into the fascial spaces near the surgical field spread to the contralateral spaces, as well as the neck and chest areas. The second case also showed extensive bilateral subcutaneous emphysema caused by the introduction of compressed air from the handpiece during crown preparation without any invasive procedure. Cases where the emphysema extends beyond the treatment site to involve the contralateral cervicofacial areas have been rarely reported. Predicting the occurrence of subcutaneous emphysema is difficult, so it is important to exercise caution during routine dental treatment. If significant bilateral cervicofacial swelling is suspected to be due to subcutaneous emphysema, prompt diagnosis with securing the patient's airway will be necessary.

Application of Adsorption Sampling and Thermal Desorption with GC/MS Analysis for the Measurement of Low-Molecular Weight PAHs in Ambient Air (환경대기 중 저분자 PAHs 측정을 위한 흡착-열탈착-GC/MS 방법의 적용)

  • Seo, Seok-Jun;Seo, Young-Kyo;Hwang, Yoon-Jung;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.362-377
    • /
    • 2014
  • Polycyclic aromatic hydrocarbons (PAHs) have been of particular concern since they are present both in the vapor and particulate phases in ambient air. In this study, a simple method was applied to determine the vapor phase PAHs, and the performance of the new method was evaluated with a conventional method. The simple method was based on adsorption sampling and thermal desorption with GC/MS analysis, which is generally applied to the determination of volatile organic compounds (VOCs) in the air. A combination of Carbotrap (300 mg) and Carbotrap-C (100 mg) sorbents was used as the adsorbent. Target compounds included two rings PAHs such as naphthalene, acenaphthylene, and acenaphthene. Among them, naphthalene was listed as one of the main HAPs together with a number of VOCs in petroleum refining industries in the USA. For comparison purposes, a method based on adsorption sampling and solvent extraction with GC/MS analysis was adopted, which is in principle same as the NIOSH 5515 method. The performance of the adsorption sampling and thermal desorption method was evaluated with respect to repeatabilities, detection limits, linearities, and storage stabilities for target compounds. The analytical repeatabilities of standard samples are all within 20%. Lower detection limits was estimated to be less than 0.1 ppbv. In the results from comparison studies between two methods for real air samples. Although the correlation coefficients were more than 0.9, a systematic difference between the two groups was revealed by the paired t-test (${\alpha}$=0.05). Concentrations of two-rings PAHs determined by adsorption and thermal desorption method consistently higher than those by solvent extraction method. The difference was caused by not only the poor sampling efficiencies of XAD-2 for target PAHs and but also sample losses during the solvent extraction and concentration procedure. This implies that the levels of lower molecular PAHs tend to be underestimated when determined by a conventional PAH method utilizing XAD-2 (and/or PUF) sampling and solvent extraction method. The adsorption sampling and thermal desorption with GC analysis is very simple, rapid, and reliable for lower-molecular weight PAHs. In addition, the method can be used for the measurement of VOCs in the air simultaneously. Therefore, we recommend that the determination of naphthalene, the most volatile PAH, will be better when it is measured by a VOC method instead of a conventional PAH method from a viewpoint of accuracy.

Inhibition of Reactive Oxygen Species (ROS) and Nitric Oxide (NO) by Gelidium elegans Using Alternative Drying and Extraction Conditions in 3T3-L1 and RAW 264.7 Cells

  • Jeon, Hui-Jeon;Choi, Hyeon-Son;Lee, OK-Hwan;Jeon, You-Jin;Lee, Boo-Yong
    • Preventive Nutrition and Food Science
    • /
    • v.17 no.2
    • /
    • pp.122-128
    • /
    • 2012
  • Gelidium (G.) elegans is a red alga inhabiting intertidal areas of North East Asia. We examined anti-oxidative and anti-inflammatory effects of G. elegans, depending on drying and extraction conditions, by determining reactive oxygen species (ROS) and nitric oxide (NO) in 3T3-L1 and RAW 264.7 cells. Extraction yields of samples using hot air drying (HD) and far-infrared ray drying (FID) were significantly higher than those using natural air drying (ND). The 70% ethanol extracts showed the highest total phenol and flavonoid contents compared to other extracts (0, 30, and 50% ethanol) under tested drying conditions. The scavenging activity on 2,2-diphenyl- 1-picrylhydrazyl (DPPH) and nitrite correlated with total phenol or flavonoid content in the extracts. The greatest DPPH scavenging effect was observed in 70% ethanol extract from FID and HD conditions. The production of ROS and NO in 3T3-L1 and macrophage cells greatly decreased with the 70% ethanol extraction derived from FID. This study suggests that 70% ethanol extraction of G. elegans dried by FID is the most optimal condition to obtain efficiently antioxidant compounds of G. elegans.

Performance Evaluation of Soil Vapor Extraction Using Prefabricated Vertical Drain System (연직배수시스템을 이용한 토양증기추출공법의 성능 평가)

  • Shin, Eun-Chul;Park, Jeong-Jun
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.9-18
    • /
    • 2007
  • Soil vapor extraction (SVE) is an effective and cost efficient method of removing volatile organic compounds (VOCs) and petroleum hydrocarbons from unsaturated soils. However, soil vapor extraction becomes ineffective in soils with low gas permeability, for example soils with air permeabilities less than 1 Darcy. Incorporating PVDs in an SVE system can extend the effectiveness of SVE to lower permeability soils by shortening the air flow-paths and ultimately expediting contaminant removal. The objective of the research described herein was to effectively incorporate PVDs into a SVE remediation system. The test results show that the gas permeability was evaluated for four different equivalent diameters, increasing the equivalent diameter results in a decrease in the calculated gas permeability. It was found that the porosity for the dry condition was greater than that of the wet condition and will allow flow rate for the same vacuum flow, offering a low resistance to the air flow.

Integration of Headspace Solid Phase Micro-Extraction with Gas Chromatography for Quantitative Analysis of Formaldehyde

  • Lo, Kong Mun;Yung, Yen Li
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.139-142
    • /
    • 2013
  • A study was carried out to evaluate the solid phase micro-extraction (SPME) for formaldehyde emission analysis of uncoated plywood. In SPME, formaldehyde was on-fiber derivatized through headspace extraction and analyzed by gas chromatography coupled with mass spectrometry (GC/MS). The SPME was compared with desiccators (DC-JAS 233), small-scale chamber (SSC-ASTM D6007) and liquid-liquid extraction (LLE-EPA 556) methods which were performed in accordance with their respective standards. Compared to SSC (RSD 4.3%) and LLE (RSD 5.0%), the SPME method showed better repeatability (RSD 1.8%) and not much difference from DC (RSD 1.4%). The SPME has proven to be highly precise (at 95% confidence level) with better recovery (REC 102%). Validation of the SPME method for formaldehyde quantitative analysis was evidenced. In addition, the SPME by air sampling directly from plywood specimens (SPME-W) correlated best with DC ($r^2$ = 0.983), followed by LLE ($r^2$ = 0.950) and SSC ($r^2$ = 0.935).

Doppler Profile Extraction to Air-Breathing Targets with PT-Waveform Received Signal and Target Tracking Information on a Ground Radar (지상레이다의 PT-파형 수신신호와 항공기 추적정보를 이용한 항공기 도플러 프로파일 추출)

  • Oh, Hyun-Seok;Kim, Soo-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.2
    • /
    • pp.129-138
    • /
    • 2017
  • This paper has been shown for the extraction of Doppler signature from the radar signal for an air-breathing targets tracked in the ground radar. For the extractions, a Doppler resolution is confirmed from mathematical modeling of PT(pulse train) waveform. Doppler signatures of air-breathing target are varied to radar aspect angle of engine and are determined from physical parameter of jet engine. To confirm such Doppler signatures, the radar signal reflected from the air-breathing target is obtained by our radar signal storage. After this extraction, radar aspect angle of engine has estimated from tracking information. Relative differences of Doppler signatures to radar aspect angle of engine is verified from these results and Doppler profiles for radar target identification appliance are presented.

A Study on Unsaturated Zone Characterization and Feasibility of Soil Vapor Extraction at a DNAPL-contaminated Site in Korea

  • Lee, Man Na Mi;Yeo, In Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.6
    • /
    • pp.48-55
    • /
    • 2013
  • This study aimed at characterizing unsaturated zone at the source zone area contaminated by DNAPL and investigating feasibility of soil vapor extraction (SVE). Five boreholes with three multi-level screens at the depth of 3.0~4.5 m, 5.5~7.0 m, and 8.0~12.0 m were installed at the source zone. Pneumatic tests were performed to determine the permeability of porous medium. Permeability was estimated to be 81.6 to 203.7 darcy, depending on the applied solutions, which was contradicted by grain size analysis of cored soil samples leading to 3.51 darcy. This is due to air flow through gravel pack during the early stage of pneumatic test. Pressure-drawdown curve in the late stage also well showed the leaky aquifer type, indicating air leakage to the ground. Air flow tests were also carried out to investigate air flow connectivity between multi-level wells, indicating that the horizontal air flow was well developed between the lower screens of the wells, not between the upper and middle screens due to the leakage to the surface. For the SVE test, there was no noticeable variation in TCE vapor concentration between three different test runs: 1. 8 hours daily for 5 days, 2. 24 hours together with air blowing at another well (BH1), 3. five consecutive days. Even for five-day consecutive test, total amount of removed TCE was estimated only to be as low as 46.5 g.

Comparative randomized study of propofol target-controlled infusion versus sevoflurane anesthesia for third molar extraction

  • Chung, Patrick K;Dhanrajani, Parmanand
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.3
    • /
    • pp.169-175
    • /
    • 2018
  • Background: The objective of this study was to compare hemodynamic and recovery characteristics of total intravenous anesthesia using propofol target-controlled infusion (TCI) versus sevoflurane for extraction of four third molar teeth. Methods: One hundred patients undergoing extraction of four third molar teeth under general anesthesia were randomized to one of two groups. Group 1 received propofol TCI-oxygen for induction and propofol TCI-oxygen-air for maintenance. Group II received a propofol bolus of 2 mg/kg for induction and sevoflurane-oxygen-air for maintenance. Heart rate, mean arterial pressure (MAP), operating time, time to emergence, nausea and vomiting, and sedation and pain scores were measured in each group. Results: Demographic data, including age, gender, weight, and height, were not significantly different between the two groups. The MAP was significantly higher after intubation (P = 0.007) and injection of anesthesia (P = 0.004) in the propofol group than in the sevoflurane group, with significant reflex bradycardia (P = 0.028). The mean time to emergence from anesthesia using propofol was 25 s shorter than that of sevoflurane (P = 0.02). Postoperatively, the propofol group was less sedated than the sevoflurane group at 30 min (0.02 versus 0.12), but this difference was not significant (P = 0.065). Conclusion: Both propofol TCI and sevoflurane are good alternatives for induction and maintenance of anesthesia for short day-case surgery. However, propofol TCI does not blunt the hemodynamic response to sudden, severe stimuli as strongly as sevoflurane, and this limitation may be a cause for concern in patients with cardiac comorbidities.