• Title/Summary/Keyword: Air Conditioning Unit

Search Result 377, Processing Time 0.027 seconds

Performance Analysis of Ground-Coupled Heat Pump System with Slinky-Type Horizontal Ground Heat Exchanger (수평형 지열 히트펌프 시스템의 냉난방 성능 분석)

  • Sohn, Byong-Hu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.230-239
    • /
    • 2012
  • Ground-coupled heat pump (GCHP) systems utilize the immense renewable storage capacity of the ground as a heat source or sink to provide space heating, cooling, and domestic hot water. The main objective of the present study is to investigate the cooling and heating performance of a small scale GCHP system with horizontal ground heat exchanger (HGHE). In order to evaluate the performance, a water-to-air ground-source heat pump unit connected to a test room with a net floor area of 18.4 m2 and a volume of 64.4 m3 in the Korea Institute of Construction Technology ($37^{\circ}39'N$, $126^{\circ}48'E$) was designed and constructed. This GCHP system mainly consisted of slinky-type HGHE with a total length of 400 m, indoor heat pump, and measuring devices. The peak cooling and heating loads of the test room were 5.07 kW and 4.12 kW, respectively. The experimental results were obtained from March 15, 2011 to August 31, 2011 and the performance coefficients of the system were determined from the measured data. The overall seasonal performance factor (SPF) for cooling was 3.31 while the system delivered heating at a daily average performance coefficients of 2.82.

A Study on Improved Heating Performance of an Apartment Housing Unit (공동주택 세대별 난방 성능 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.

Study on the Cooling Performance of Single and Cascade Refrigeration Systems Using Thermoelectric Modules (열전소자를 이용한 싱글 및 캐스케이드 냉동시스템의 냉각 성능에 관한 연구)

  • Lim, Changhak;Kim, Dongwoo;Kim, Yongchan;Seo, Kookjeong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.12
    • /
    • pp.641-646
    • /
    • 2013
  • The purpose of this study is to improve the cooling performance of single and cascade refrigeration systems using thermoelectric modules. The system consists of a heat sink, fan, and thermoelectric module. The operating parameters considered in this study include power distribution between the first- and second-stage thermoelectric modules, air flow, and variable condensing unit. The cooling capacity increased with decreases in the temperature difference between hot and cold surfaces, but decreased with increases in the condensing temperature. The COP decreased with increasing electric power of the thermoelectric module because of the increased Joule heat. The cooling performance improvement using the thermoelectric module is represented by the freezer temperature.

A Study on the Heating Characteristics of Radiant Floor Panel Using Heat Pipes with the Double Wick (이중 윅 타입 히트파이프를 이용한 바닥복사패널의 난방특성 연구)

  • Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.183-189
    • /
    • 2012
  • Most of the domestic residential buildings have used the traditional radiant heating system, circulating hot water through the cross-linked polyethylene(PE-X) pipe buried in the floor panel of the heating space. New type of the heating panel was recently developed using heat pipes with double wicks. Some experiments were carried out in this study to verify the thermal characteristics of this heating system at the unit heating space which surrounded by outer space whose temperature of air be maintained scheduled value with time. Through the various experiments with several parameters, such as flow rate, inlet and outlet temperatures of hot water and the heating duration and so on, we found that the floor heating system with heat pipes was able to reduce the pumping power for hot water circulation by 4~31% compared with the conventional panel heating system using PE-X pipe. These results could be used for optimal design and efficient operation of the heating system as well as improvement of thermal comfort.

Measurement and Analysis of Energy Consumption of HVAC Equipment of a Research Building (연구용 건물의 열원 및 공조기기의 에너지 소비량 측정 및 분석)

  • Kim Seong-Sil;Kim Youngil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.914-922
    • /
    • 2004
  • In this study, measurement and analysis of energy consumption of a research building have been conducted. The energy audit procedure includes monitoring of electricity and LNG consumption over a period of three yews from 2000 to 2002. Data acquisition system for collecting energy consumption data of HVAC equipment such as chillers, fan filter units, AHUs, cooling towers, boilers, pumps, fan coil units, air compressors and etc. has been installed in a building located in Seoul. Data collected at an interval of 1 minute are analyzed for studying the energy consumption pattern of a research building. Percentage of energy consumption of all HVAC equipment is $51.0\%$ in 2000, $55.4\%$ in 2001, and $62.3\%$ in 2002, respectively. Electricity consumption of chillers accounts for $17.6\%$ of the total energy consumption, which is the largest. Annual energy consumption-rate per unit area is $840.5Mcal/m^2{\cdot}y$ in 2000, $1,064.8Mcal/m^2{\cdot}y$ in 2001, and $1,393.0Mcal/m^2{\cdot}y$ year 2002, respectively.

Case Study on the Energy Consumption Unit of District Apartments (지역난방 공동주택의 에너지원별 원단위 사례분석)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Oh, Byung-Chil;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.474-480
    • /
    • 2014
  • This study investigated the total energy consumption and the energy consumption by type of 31 apartment complexes in Daejeon. The energy is supplied to the apartments from district heating, and can be divided into hot water, electricity, and gas. Hot water is used in for space heating and for domestic hot water (DHW), and electricity is used for plugs, cooling, ventilation, and public utilities (street lights, pumps, elevators, etc.). All gas supplied from district heating is used for cooking. As a result, the consumption unit of each energy source of independent dwelling areas was calculated to be $103.7kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$) for thermal energy, $48.0kWh/m^2{\cdot}a$ ($4,646kWh/H{\cdot}a$) for electricity, and $10.5kWh/m^2a$ ($1,015kWh/H{\cdot}a$) for gas, so the entire consumption was calculated to be $162.3kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$).

A Study on the Development of Power-Line EMI Filter for the Prevention of Conduction Noise by Coil Loads. (코일성 부하에 의한 전도 노이즈 방지 목적의 전원용 EMI필터 개발 연구)

  • Kim, Byeong Jun;Joo, Jae-hun;Kim, Jin Ae;Baek, Pan Keun;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.175-179
    • /
    • 2009
  • this paper proposes a filter design that makes to be satisfied EMC spec. in reliability test of analogue switch for electronic equipment and air conditioning load unit. A designed electromagnetic wave filter was applied to minimize an mutual interference and surrounding environment and improve the product's quality being satisfied to EMC standard. By simulation, using a spectrum analyzer at the 30MHz~1GHz band, ISO/JASO standard frequency range, and simplified EMI chamber, energy distribution of a specific frequency band was analyzed and the capacity of the element which composed the filter was determined in order to implement the most suitable electromagnetic wave filter.In fact, it was certificated that noise decrease by filter addition to the analogue switch for electronic equipment and air conditioning load unit in Certification Authority, and confirmed that the unit is carried out a normal action without electromagnetic wave interference.

  • PDF

Design and Implementation of a Digital Control Unit for an Oxygenaire Servo Baby Incubator

  • Zahran, Mohamed;Salem, Mahmoud;Attia, Yousry;Eliwa, Aref
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.121-130
    • /
    • 2008
  • This paper introduces a design and implementation of a digital control unit for an Oxygenaire Servo Baby Incubator. The control unit is designed and implemented according to international standards. The control unit is based on an AVR Atmel microcontroller unit. It is built for monitoring and control and displays the three main temperature values: set point temperature, baby skin temperature and air temperature. User friendly software is implemented. The implemented control unit was tested in the laboratory as well as in the field. The control unit is sensitive to change of $0.1^{\circ}C$. At startup, based on a unique control strategy, the incubator reaches its steady state in about 14 minutes. The system schematic diagrams are shown in the paper. Also, programs flow charts are presented. The control unit was designed and implemented based on a contract between the Electronics Research Institute (ERI) and ENGIMED Company. The authors would like to thank ERI and ENGIMED for introducing all required finance and shoring to complete this work.

An Experimental Study on the Deodorization Performance Enhancement of the Air Handling Unit Using a Nano-Silver Material (은나노 소재를 이용한 공조기의 탈취 성능 향상에 관한 실험적 연구)

  • Nam, Sang-Yeob;Kang, Byung-Ha;Song, Ji-Hyeon;Han, Sung
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.739-744
    • /
    • 2009
  • The filter has long been used in purification processes for indoor air quality. To determine the deodorization effect of several filter materials in a full-scale air-handling system, the present study has been carried out using a wind tunnel equipped with a heat exchanger and various filter materials, such as commercial fabric, activated carbon(AC) and silver nano-particles attached to activated carbon(Ag-AC). The experiment was conducted using an odor substance with ammonia, acetaldehyde, acetic acid. The results obtained indicate that odor substance is substantially decreased on the moisture condensation on the surface of the heat exchanger. The fabric filter has no effect for removal of odor substances. The deodorization efficiency is found to be approximately 7% in the AC filter, while the deodorization efficiency is increased up to 10% using the Ag-AC filter.

  • PDF

Development of Home Indoor Air Quality evaluation program considering planning and construction stage (주거 건물의 설계 및 시공단계를 고려한 실내공기질 평가 프로그램 개발에 관한 연구)

  • Choi, Dong-Hee;Kang, Dong-Hwa;Kim, Sun-Sook;Yeo, Myoung-Seok;Kim, Kwang-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.51-56
    • /
    • 2005
  • The objective of this study is to develop Home Indoor Air Quality evaluation prorgram considering planning and construction stage for architects, engineers and occupants to estimate and improve the IAQ of a home. In this study, the IAQ modeling technique was discussed to determine the appropriate modeling of housing unit in Korea. The program algorithm was developed based on the selected model reflecting planning and construction stage. This program can be applied to estimate the IAQ of a home and encourage appropriate action in advance.

  • PDF