• Title/Summary/Keyword: Air Condition

Search Result 4,337, Processing Time 0.032 seconds

Thermal Analysis of a Spent Fuel Storage Cask under Normal and Off-Normal Conditions

  • Lee, J. C.;K. S. Bang;K. S. Seo;Kim, H.D.;Park, B. I.;Lee, H. Y.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.601-608
    • /
    • 2003
  • Thermal analyses have been carried out for a spent fuel dry storage cask under normal and off-normal conditions. Environmental temperature is assumed to be $15^{\circ}C$ under the normal condition. The off-normal condition has an environmental temperature of $38^{\circ}C$. An additional off-normal condition is considered as a partial blockage of the air inlet ducts. Two of the four air inlet ducts are assumed to be completely blocked. The maximum temperatures of the fuel rod and concrete overpack were lower than the allowable values under the normal condition. Temperature distributions for the off-normal conditions were slightly higher than the normal conditions.

  • PDF

Performance Variation of the Air Curtain for Various Discharge Angles in Feating Space (난방공간에서 에어커튼의 토출각도 변화에 따른 성능 변화)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.57-63
    • /
    • 2010
  • Air curtains are widely used for gates of shopping mall, warehouse, cold stores and refrigerated display cabinets. The purpose of the air curtain is to reduce the infiltration of outdoor air and heat loss from the air conditioning space to ambient air. The discharge angle of air curtain is very important as the sealing efficiency is affected by it. This paper presents a performance of single jet air curtain in heating space when the discharge angle of nozzle changes. A numerical simulation is used to study the influence of various parameters on the efficiency of the downward-blowing air curtain device which is installed inside of the wall above the door. The performance of the air curtain is evaluated by sealing efficiency which provides the assessment of the energy savings. A condition of discharge angle that has the highest sealing efficiency is proposed.

Study on the Effect of Season Conditions to the Performance of Longitudinally-Finned Air-Heating Vaporizer

  • Djajadiwinata, Eldwin;Lee, Yong-Hun;Kim, Pil-Hwan;Park, Gi-Tae;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2321-2326
    • /
    • 2007
  • To return LNG to a gaseous state, it is fed into a regasification plant. For inland area, where pipelines do not exist or difficult to construct, the LNG is delivered to the inland-receiving terminal available at that area, regasified and delivered to consumers. At inland-receiving terminal, air-heating vaporizer type is usually used. To contribute in developing an efficient air-heating vaporizer, experiment on finned type air-heating vaporizer using 8 fins, 50 mm fin length (8fin50le) and 4 fins, 75 mm fin length (4fin75le) were conducted. The experiments were conducted by varying the ambient condition and the length of the vaporizer. The ambient air was controlled so that it has the same condition with air condition in every season available. $LN_2$ is used to substitute LNG because of safety reason. The results show that characteristics of the finned type 4fin75le vaporizer are comparable to finned type 8fin50le vaporizer at all season.

  • PDF

Resonance Condition of the Resonance Cavity and Air Gap in the Sacred Bell of the Great King Seongdeok (성덕대왕신종의 명동과 간극의 공명조건)

  • Kim, Seock-Hyun;Jeong, Won-Tae;Kang, Yun-June
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.4
    • /
    • pp.223-230
    • /
    • 2011
  • Korean bell is hung with some air gap between the bell bottom and the ground. In addition, it has a peculiar acoustic element, so called resonance cavity below the bell. A proper design of the air gap and cavity size dramatically amplifies the bell sound by resonance effect. Bell interior cavity, air gap and resonance cavity consist of an acoustic cavity system. When the acoustic cavity frequency coincides with the natural frequency of the bell body, the frequency component is significantly amplified. On the Sacred Bell of the Great King Seongdeok, this study proposes a resonance condition of the cavity system considering air gap effect for the first time. With the exact dimension of the bell, boundary element analysis is performed using SYSNOISE. Finally, this study reveals how the temperature in season influences the resonance condition and proposes a concept of variable type resonance cavity. By using the variable type resonance cavity, the cavity size is controlled on site and exact resonance is available regardless of temperature difference in season.

Biosurfactant 생산균주 Pseudomonas aeruginosa F722의 배양특성

  • O, Gyeong-Taek;Go, Myeong-Jin;Park, Hye-Yeong;An, Gil-Won;Kim, Hwan-Beom;Lee, Ji-Heon;Gang, Chang-Min;Jeong, Seon-Yong
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.393-397
    • /
    • 2003
  • P. aeruginosa F722 produces biosurfactant (BS) while degrading hydrocarbons. BS production was 0.78 $g/{\ell}$ on the C-medium. However, BS production increased by 1.66 $g/{\ell}$ on the condition of 0.05% (w/v) $NH_4Cl+0.1%$ (w/v) yeast extract and 3.0% (w/v) glucose, which was proved to be advantageous to BS production. In the condition of aeration of 1.0 liter per minute (LPM), BS production was increased 20% (1.94 $g/{\ell}$)more than 1.66 $g/{\ell}$ produced when the air was not supplied. Moreover, the velocity of glucose degradation at both of log and stationary growth phases increased from 0.25 and 0.18 $h^{-1}$ to 0.33 and 0.29 $h^{-1}$ respectively when the air was supplied. Besides, BS activity was more stabilized on the condition of air supply.

  • PDF

Properties of Dandelion Tea by Pre-treatment Process (전처리 방법에 따른 민들레 볶음차의 특성)

  • 오상룡;양진무;허향옥;박준희;강우원;강미정;김광수
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.10 no.2
    • /
    • pp.136-141
    • /
    • 2000
  • This study was conducted to analyze the properties of the roasted dandelion tea prepared after various pre-treatments such as pre-drying, steaming and air blast drying. The dandelion tea was prepared by roasting the pre-treated dandelion leaves and its total yield, pH, soluble solid content, turbidity, browning and sensory value were evaluated. Total yield and soluble solid content were the highest in case of air blast drying. Turbidity and browning degree were similar in all the teas regardless of their pre-treatment including pre-drying, steaming or air blast drying. The best palatability in the sensory evaluation was obtained at the steaming condition for 60 sec without pre-drying. Longer air blast drying time resulted in the increase in the a and b values. turbidity, browning degree, total yield and soluble solid content in the air blast dried tea.

  • PDF

Experimental Study on Natural Ventilation Performance of Double Facade System in Heating Period (난방기 중 이중외피 시스템의 자연환기 성능분석에 관한 실험적 연구)

  • Lee, Keon-Ho;Kim, Hyeon-Soo;Ko, Yung-Woo;Son, Young-Joo
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.43-50
    • /
    • 2006
  • A Double Facade System(DFS) is well known as an innovative solution of ecological facade in the west european countries. There are more than 200 various realized DFS in Germany. At the same time, the korean engineers have researched to find out the physical advantages of DFS in the moderate korean climate, which has a very humid summer with high temperature and a dry winter with low temperature. For example, the monthly mean temperature in Korea comes up to 28K, while that in Germany comes up to only 19K. That is, why a other solution of DFS is needed in Korea. This study has experimented the physical performance of the natural ventilation in the heating period. The preheating function of the cold air by DFS can improve no doubt the performance of the natural ventilation at the cold season as well as spring and autumn. The physical difference between single and double facade on natural ventilation has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. The results show the natural ventilation of the DFS has definitely much more comfortable than that of the single facade system. The air velocity of the inflow as well as the air temperature in the DFS provide a more stable condition than in the SFS. The theoretical limit(air velocity max 0.2m/s, air temperature min. $18^{\circ}C$, temperature difference between 100mm and 1700mm height max. 3K) on the indoor comfortableness doesn't go over in the DFS. On the other hand, the SFS showed an unstable condition with an excess of comfortableness limit on air velocity as well as temperature. In view of the researching results so far achieved, the research came to a conclusion, that the DFS can provide a more comfortable indoor condition by the preheating in the heating period than a SFS, and the period of natural ventilation in winter time could be definitely increased at the DFS.

Analysis on the Dielectric Characteristics of Dry Air According to Pressures for Developing an Eco-friendly High Voltage Switchgear (친환경 고압배전반 개발을 위한 dry air의 압력별 절연내력특성 분석에 관한 연구)

  • Nam, Seok-Ho;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1560-1565
    • /
    • 2011
  • The environmental pollution caused by green-house gases such as $CO_2$ and $SF_6$ has been becoming the main issue of industrial society. Many developed countries are making efforts to minimize the amount of $CO_2$ emission come from the operation of high voltage electrical apparatuses. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions. Nowadays, the study on the development of dry air insulated switchgear (DAIS) which is known as an eco-friendly electrical apparatus is in progress. A DAIS is advantageous for minimizing the effect of impurities and enhancing the dielectric characteristics over an air insulated switchgear (AIS) by applying constant pressure to an enclosed cubicle. Therefore, a study on the electrical insulation performance of dry air as a gaseous insulation medium is conducted in this paper to substitute a gas insulated switchgear (GIS) for DAIS. As results, it is verified that the AC dielectric characteristics of dry air are similar to those of air and the lightning impulse dielectric characteristics of dry air are superior to those of air at 1bar pressure condition. However, dry air is of inferior dielectric characteristics to $SF_6$ at 4bar pressure condition. Finally, it is suggested that the internal pressure of DAIS should be over 4bar pressure to develop a high voltage switchgear which has similar electrical performance to a conventional GIS. Also, the empirical formulae on calculating the maximum electric field intensity at sparkover of dry air are deduced by experiments according to pressures. It is expected that these results are helpful to design and develop a high voltage electrical apparatus.

Numerical Investigation on the Thermal Characteristics of Mild Combustion According to Co-axial Air (동축공기에 따른 Mild 연소의 열적 특성에 대한 수치연구)

  • Hwang, Chang-Hwan;Baek, Seung-Wook;Kim, Hak-Young
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.4
    • /
    • pp.1-8
    • /
    • 2010
  • Mild combustion is considered as a promising combustion technology for energy saving and low emission of combustion product gases. In this paper, the controllability of reaction region in mild combustion is examined by using co-axial air nozzle. For this purpose, numerical approach is carried out. Propane is considered for fuel and air is considered for oxidizer and the temperature of air is assumed 900K slightly higher than auto ignition temperature of propane. But unlike main air, the atmospheric condition of co-axial air is considered. Various cases are conducted to verify the characteristics of Co-Axial air burner configuration. The use of coaxial air can affect reaction region. These modification help the mixing between fuel and oxidizer. Then, reaction region is reduced compare to normal burner configuration. The enhancement of main air momentum also affects on temperature uniformity and reaction region. The eddy dissipation concept turbulence/chemistry interaction model is used with two step of global chemical reaction model.

Characteristics of Mn-Ni-Co system for automobile fuel shortage detecting sensor with $Bi_2O_3$ addition ($Bi_2O_3$를 첨가한 Mn-Ni-Co계 써미스타의 자동차 연료 부족 감지용 센서 특성)

  • 윤중락;이헌용;김두용;오창섭
    • Electrical & Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.455-462
    • /
    • 1996
  • Automobile Fuel Shortage Detecting Sensor, in this paper, was fabricated by using heat dissipation coefficient difference between gasoline and air condition the NTC thermistor of Mn-Ni Co system with the composition ratio of Mn$_{3}$O$_{4}$ : 9wt%, NiO : 28wt%, and CO$_{3}$O$_{4}$ : 61wt%. The condition of sensor operation is that, for turn-on characteristics, the time of arriving at 135mA must be less than 180 second when the DC voltage of 11V is applied in the air condition of -10.deg. C and that, for turn-off characteristics, the saturation current must be less than 60mA when the DC voltage of 15V is applied in the gasoline condition of 60.deg. C. It is known, from the experimental results, that the resistance range and B-constant for the Automobile Fuel Shortage Detecting Sensor with dimension of 5*3*0.9mm were 850-1150.ohm. and 1150-1250.deg. C, respectively and the resistance range and B-constant were agree with that of sensor operation condition. When Bi$_{2}$O$_{3}$ of 0-0.5wt% was added to Mn$_{3}$O$_{4}$ : 9wt%, NiO : 28wt%, and CO$_{3}$O$_{4}$ : 61wt% composition, the resistivity and B-value were 380-430(.ohm.-cm) and 1930 - 2030, respectively. Particularly, for Bi$_{3}$O$_{3}$ of 0.25-0.5wt%, the sintering density of over 90% and the operation characteristics necessary to Automobile Fuel Shortage Detecting Sensor were obtained. The difference of heat dissipation coefficient gasoline and air condition was 15 times.

  • PDF