Performance Analysis of an Aircraft Gas Turbine Engine using Particle Swarm Optimization

  • Choi, Jae Won;Sung, Hong-Gye
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.4
    • /
    • pp.434-443
    • /
    • 2014
  • A turbo fan engine performance analysis and the optimization using particle swarm optimization(PSO) algorithm have been conducted to investigate the effects of major performance design parameters of an aircraft gas turbine engine. The FJ44-2C turbofan engine, which is widely used in the small business jet, CJ2 has been selected as the basic model. The design parameters consists of the bypass ratio, burner exit temperature, HP compressor ratio, fan inlet mass flow, and nozzle cooling air ratio. The sensitivity analysis of the parameters has been evaluated and the optimization of the parameters has been performed to achieve high net thrust or low specific fuel consumption.

Investigation on Characteristics of Interior Permanent Magnet Synchronous Motor according to Pole-Slot Combination (매입형 영구자석 동기전동기의 극 수 슬롯 수 조합에 따른 특성에 관한 연구)

  • Bahn, Ji-Hyung;Kwon, Soon-O;Ha, Seung-Hyonng;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.771-772
    • /
    • 2006
  • Recently, Interior Permanent Magnet Synchronous Motor(IPMSM) is widely used in the industry applications such as power train for hybrid vehicles and compressor motors of air-conditioner due to its high power density and wide speed range. In designing motors, pole slot combination should be chosen properly according to the use of the motor and driving method in the initial design stage, accordingly there have been many researches about pole slot combination. As a part of the studies, this paper presents a comparison of characteristics of concentrated winding IPMSM, such as back-emf, Total Harmonic Distortion(THD) and core losses for each pole slot combination. By comparing the characteristics of each model, this paper can be a guide or reference in determining pole slot combination in the initial design stage.

  • PDF

Optimal Design of Synchronous Reluctance Motor by Loss & Efficiency Evaluations Related to Slot Number using Response Surface Methodology (반응표면법을 이용한 슬롯수 관련 손실, 효율 평가애 따른 동기형 릴럭턴스 전동기의 최적 설계)

  • Park, Seong-June;Jang, Young-Jin;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.123-125
    • /
    • 2004
  • This paper presents the application of response surface methodology (RSM) to design optimization for two types of synchronous reluctance motors (SynRMs); one has 12 slots with distributed winding, and the other has 6 slots with concentrated winding, to improve the ratio between torque ripple and average torque. The usefulness of RSM in optimization problem of SynRM is verified as compared with the results of finite element analysis. In the end, the optimized two SynRMs are compared with SynRM currently used in air-conditioning compressor in connection with torque performance and loss.

  • PDF

Software design technique of Train Control and Monitoring System (TCMS) using CASE tool (CASE tool을 이용한 전동차 제어감시장치 (TCMS)의 소프트웨어 설계기법)

  • Han, Seong-Ho;Ahn, Tae-Ki;Kim, Won-Kyong;Choi, Kyu-Hyoung
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.358-360
    • /
    • 1997
  • The train control and monitoring system(TCMS) is an on board computer system in railway vehicles performing the control, supervisory and diagnostic functions of the complete train. This system replaces a lot of hardwired relays and minimizes the necessaries vehicle wiring thus increasing the reliability of the train. In this paper, we proposed a software design technique of TCMS using CASE tool (SAO+). The TCMS functions are implemented in software easily programmed, using a functional block, graphic programming language. We applied the compressor air module to a case study.

  • PDF

Optimal Design of Synchronous Reluctance Motor Related to Slot Number using Response Surface Methodology (반응표면방법론을 적용한 슬롯 수에 따른 동기형 릴럭턴스 전동기의 최적 설계)

  • Park, Seong-June;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.117-119
    • /
    • 2005
  • This parer presents the application of response surface methodology (RSM) to design optimization for two types of synchronous reluctance motors (SynRMs) one has 12 slots with distributed winding, and the other has 6 slots with concentrated winding, to improve the ratio between torque ripple and average torque. The usefulness of RSM in optimization problem of SynRM is verified as compared with the results of finite element analysis. In the end, the optimized two SynRMs are compared with SynRM currently used in air-conditioning compressor in connection with torque performance and loss.

  • PDF

Performance analysis of R404A refrigeration system using R744 as secondary refrigerant (R744를 2차냉매로 사용하는 R404A용 냉동시스템의 성능 분석)

  • Oh, H.K.;Son, C.H.
    • Journal of Power System Engineering
    • /
    • v.16 no.2
    • /
    • pp.24-29
    • /
    • 2012
  • In this paper, an analysis on performance and exergy of R404A refrigeration system using R744 secondary refrigerant was performed numerically to optimize the design for the operating parameters. The operating parameters considered in this study include subcooling and superheating degree, internal heat exchanger and compression efficiency, evaporation and condensation temperature in the R404A refrigeration cycle and temperature difference of cascade heat exchanger. The main results are summarized as follows : The COP(coefficient of performance) of R404A refrigeration system increases with increasing evaporation temperature. The evaporation capacity of R744 as secondary refrigerant increases with the increase in evaporation pressure of R744 secondary refrigeration. And the enthalpy in the evaporator outlet of R744 increases with the increasing evaporation pressure of R744 secondary refrigeration. Therefore, it is important to analysis for the relationship between COP of R404A refrigeration system and refrigeration capacity of R744. As cascade evaporation temperature increase, the exergy loss of condenser and compressor using R404A is the largest among all components. Therefore, the exergy loss in the condenser and compressor using R404A must be decreased to enhance the COP of R404A refrigeration system with R744 secondary refrigerant.

Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Heating-main Operating Mode (난방주체 운전모드에서의 동시냉난방 열펌프 성능향상에 관한 실험적 연구)

  • Kang, Hoon;Jung, Hyen-Joon;Joo, Young-Ju;Kim, Yong-Chan;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.245-251
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the heating-main operating mode were investigated experimentally. The system adopted a variable speed compressor with four indoor units and one outdoor unit with R-410A. In the heating-main mode, the cooling capacity was lower than the design cooling capacity due to the reduction of the flow rate in the indoor unit for the cooling, with the increase of the heating capacity. To solve these problems, the performance characteristics of the simultaneous heating and cooling heat pump in the heating-main mode were investigated by varying the flow rate to the indoor unit for the cooling and the compressor rotating speed. In addition, the adequate control methods were suggested to improve the system efficiency.

A Study of FEED Verification process of Small Utility Equipment in Offshore plant (해양플랜트 소형 유틸리티장비의 FEED 검증 프로세스에 대한 연구)

  • Han, Seong-Jong;Park, Beom
    • Plant Journal
    • /
    • v.13 no.2
    • /
    • pp.39-45
    • /
    • 2017
  • This paper is a study on FEED validation model that can be used in the bidding stage of small utility equipment in offshore plant industry using system engineering technique. Currently, domestic marine plant equipment industry companies are faced with the financial risk of project execution as they enter marine plant. The major cause was the insufficient ability to verify the FEED output from the contractor (Engineering or Procurement and Construction) of the equipment manufacturer (COMPANY or EPC). Therefore, we propose FEED design verification method that simplifies the system engineering method that sequentially applies requirements analysis, function, performance analysis and physical architecture building process. Also, we verified the suitability of the developed model by comparing the results of applying the developed FEED verification model and the verification method that depends on the existing experience for the small utility equipment (Air Compressor).

  • PDF

Performance analysis for load control of R744(carbon dioxide) transcritical refrigeration system using hot gas by-pass valve (핫가스 바이패스 밸브를 이용한 R744용 초임계 냉동사이클의 부하제어에 대한 성능 분석)

  • Roh, Geun-Sang;Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2189-2194
    • /
    • 2009
  • The automatic hot gas by-pass technique is applied to control the capacity of refrigeration and air-conditioning system when operating at part load. In the scheme, the hot gas from the compressor is extracted and injected into the outlet of an evaporator through a hot gas by-pass valve. Thus, In this paper, the hot gas by-pass scheme for CO2 is discussed and analyzed on the basis of mass and energy conservation law. A comparative study of the schemes is performed in terms of the coefficiency of performance (COP) and cooling capacity. The operating parameters considered in this study include compressor efficiency, superheating degree, outlet temperature of gas cooler and evaporating temperature in the R744 vapor compression cycle. The main results were summarized as follows : the superheating degree, outlet temperature and evaporating temperature of R744 vapor compression refrigeration system have an effect on the cooling capacity and COP of this system. With a thorough grasp of these effect, it is necessary to design the compression refrigeration cycle using R744.

Friction Characteristics of Magnetic Clutch Used in Automobiles (차량용 마그네틱 클러치의 마찰 특성)

  • Kim, Dong-Wook;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.25 no.4
    • /
    • pp.243-249
    • /
    • 2009
  • A magnetic clutch consists of pulley and disk. It delivers and isolates the power needed for the operation of the compressor used in automotive air conditioning system. To improve the performance, efficiency and durability of automotive air conditioning system, appropriate design of pulley, disk and system working parameters(the magnitude of magnetic force, and so on) is necessary. For that goal, it is required to understand the friction characteristics of magnetic clutch for the initial operating time. In this study, friction tests were carried out in order to investigate the effect of sliding velocity on the friction characteristics of magnetic clutch using pin-on-disk type friction and wear tester. For experiments, pulley and disk used in real automotive air conditioning system were considered. Friction experiments were conducted under various sliding velocities, and coefficients of kinetic friction were obtained. Under the experimental conditions considered in this study, the coefficients of kinetic friction increased with the increase of test number(sliding distance) and decreased with the increase of sliding velocity.