• 제목/요약/키워드: Air Bubbles

검색결과 285건 처리시간 0.022초

수격파를 이용한 배관 세정기 개발 연구 (A Study on the Development of the Water Hammering Cleaner System for Pipeline)

  • 김홍식;김윤제;박광진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.675-678
    • /
    • 2002
  • In order to develop the water hammering cleaner system for removing scale and slime in inner metal or non-metal piping wall, the flow characteristics are investigated by numerical and experimental methods. The air bubbles in the piping systems as a shock wave are formed and transferred with the water flow in the piping. The governing equations are derived from making using of three-dimensional Wavier-Stokes equations with the standard $k-{\varepsilon}$ turbulence model and SIMPLE algorithm. Pressure distributions in the pipeline are calculated for different air supply pressures. Also, we prepared some experimental results of the pressure differences for various air supply times.

  • PDF

익형 변화에 따른 유도공기부상기 성능특성 연구 (Effects of Blade Configuration on the Performance of Induced Gas Flotation Machine)

  • 송유준;이지구;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제20권2호
    • /
    • pp.41-46
    • /
    • 2017
  • The flotation performance of the induced gas flotation (IGF) machine is considerably influenced by geometric configurations of rotor and stator. The interaction of rotor and stator, which are the most important components in IGF, serves to mix the air bubbles. Thus, the understanding of flow characteristics and consequential analysis on the machine are essential for the optimal design of IGF. In this study, two-phase (water and air) flow characteristics in the forced-air mechanically stirred Dorr-Oliver flotation cell was investigated using ANSYS CFX. In addition, the void fraction and the velocity distributions are determined and presented with different blade configurations.

신생아의 양측성기흉을 동반한 긴장성 종격동 기종 (Tension pneumomediastinum associated with bilateral pneumothorax in neonate)

  • 이두연
    • Journal of Chest Surgery
    • /
    • 제15권3호
    • /
    • pp.285-289
    • /
    • 1982
  • Pneumomediastium in a newborn baby is a rare condition and is usually manifested by respiratory and circulatory distress syndrome. We recently have experienced a newborn baby of severe tension pneumomediastinum associated with bilateral pneumothorax. The patient in this report was a day old female and the mother of the baby a lot of difficulties during her delivery and the aid of vaccuum was necessary. This patient was received closed thoracotomy and followed by explothoracotomy and excision of tension multiple air bubbles. The post-op. course is not uneventful.

  • PDF

Numerical investigation of a novel device for bubble generation to reduce ship drag

  • Zhang, Jun;Yang, Shuo;Liu, Jing
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권5호
    • /
    • pp.629-643
    • /
    • 2018
  • For a sailing ship, the frictional resistance exerted on the hull of ship is due to viscous effect of the fluid flow, which is proportional to the wetted area of the hull and moving speed of ship. This resistance can be reduced through air bubble lubrication to the hull. The traditional way of introducing air to the wetted hull consumes extra energy to retain stability of air layer or bubbles. It leads to lower reduction rate of the net frictional resistance. In the present paper, a novel air bubble lubrication technique proposed by Kumagai et al. (2014), the Winged Air Induction Pipe (WAIP) device with opening hole on the upper surface of the hydrofoil is numerically investigated. This device is able to naturally introduce air to be sandwiched between the wetted hull and water. Propulsion system efficiency can be therefore increased by employing the WAIP device to reduce frictional drag. In order to maximize the device performance and explore the underlying physics, parametric study is carried out numerically. Effects of submerged depth of the hydrofoil and properties of the opening holes on the upper surface of the hydrofoil are investigated. The results show that more holes are favourable to reduce frictional drag. 62.85% can be achieved by applying 4 number of holes.

수평원통 관에서 선회유동의 공기동 발생에 관한 실험적 연구 (An Experimental Study on the Generation of Air-core with Swirl Flow in a Horizontal Circular Tube)

  • 장태현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.922-930
    • /
    • 2004
  • An experimental investigation was performed to study on the generation of air bubble and air core with swirling flow in a horizontal cicular tube. To determine some characteristics of the flow, 2D PIV technique is employed for velocity measurement in water. The experimental rig is manufactured from an acryl tube. The test tube diameter of 80mm, and a length of 3000mm. The used algorithm is the gray leve cross-correlation method(Kimura et al. 1986). An Ar-ion laser is used and the light from the laser(500mW) passes through a probe to make two-dimensional light sheet. In order to make coded images of the tracer particles on one frame, an AOM(Acoustic-Optical Modulator) is used. The maximum axial velocities showed near the test tube wall at y/D =0.1 and y/D =0.9 along the test tube. The higher Reynolds number increase, the lower axial velocities are showed in the center of the test tube. The air bubbles are generated from Re =10,000 and developed into air core from the recirculating water pump rpm equal 30Hz. The pressure and temperature are measured across the test tube at X/D=3.33.

Study on bubble detection sensor for safe sap and blood injection

  • Yun, Young Gi;Lee, Hoo Young;Park, Koo Rack
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권9호
    • /
    • pp.149-154
    • /
    • 2017
  • The infusion of fluid and blood is necessary in the ward, operating room, recovery room, neonatal room, etc. for nutrition and blood supply to the patient, but air bubbles generated during infusion of fluid and blood circulate along the artery or vein. Serious illnesses occur and there is also a risk of death. In this paper, we propose a medical bubble detection system, a bubble detection system, a bubble detection alarm system, and a communication method in order to develop a safer fluid and blood injection system in the existing system, which is detected by a medical staff monitoring system or an ultrasonic bubble detection sensor In this study, infrared rays are transmitted to a tube through a tube for injecting fluid or blood into a patient, infrared rays transmitted by an infrared ray emitting section are received, and the amount of light is measured in real time. Based on the data, we study how to detect and analyze the presence of bubbles in fluid and blood.

정수장(淨水場) Scum의 발생(發生) 원인분석(原因分析)과 살수에 의한 물리적(物理的) 제거효과(除去效果) (Analysis on Occurrence of the Scum in Water Treatment Plants and Its Removal by Water Spray Method)

  • 윤재흥;최계운
    • 상하수도학회지
    • /
    • 제8권3호
    • /
    • pp.26-33
    • /
    • 1994
  • To slove the problems by the scum, which causes operational and water quality problems in water treatment plants, several researches were conducted based on the site investigations on twelve large water treatment plants, biological and chemical analysis of scum, analyzing raw water quality data. Two types of scum, which are from scum and floe scum, can be classified based on the analysis and site investigations. The major parameter generating floe scum was indicated as fine bubbles dissolved in the water. The fine bubbles dissolved in the water can be generated by over-saturated air in the water, adding aluminum surface as the coagulant, conducting the break point pre-chlorination and so on. The water spray method, which is one of the physical treatment methods for removing scum, was selected for conducting experiments on the removal efficiency in the flocculation basin of the real water treatment plant. The water spray method was successfully applied for removing scum with the advantages of using spiral nozzles in case of using the raw water rather than the cleaned water.

  • PDF

수직상향 기체주입시 기포거동에 관한 연구 (A Study on the Bubble Behavior in the Vertical-upward Gas Injection)

  • 서동표;오율권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.712-716
    • /
    • 2003
  • In the present study, the gas injection system based on air-water model was designed to investigate the behavior characteristics of bubbles injected into a ladle. The parameters such as gas volume fraction and bubble rise velocity were exprementally measured in a gas-liquid flow region. To measure gas volume fraction, an electo-conductivity probe was used and bubble rise velocity was obtained by a high speed CCD camera. Gas volume fraction was symmetric to the axis of nozzle secured on the bottom of a ladle. The bubble rise velocity was calculated for two different experimental conditions. That is, gas flow conditions were following two case: 1) Q = $0.63{\times}10^{-4}$ $m^{3}/s$, 2) $1.26{\times}10^{-4}$ $m^{3}/s$. As a gas injected into the liquid ladle, the liquid-phase region is circulated by bubbles' behavior. The bubble rise velocity was influenced of the circulation flow of liquid phase. As a result, the bubble rise velocity was appeared higher middle region of ladle than near the nozzle.

  • PDF

X-ray PTV 기법을 이용한 불투명 튜브 내부의 미세기포의 크기 및 속도 동시 측정 (Simultaneous Measurement of Size and Velocity of Microbubbles inside Opaque Tube Using X-ray PTV Technique)

  • 김석;이상준
    • 한국가시화정보학회지
    • /
    • 제4권2호
    • /
    • pp.69-75
    • /
    • 2006
  • The microbubbles were used in various fields, such as turbulent control, drag reduction, material science and life science. The X-ray PTV using X-ray micro-imaging technique was employed to mea-sure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}$=2.7mm) were tested. Due to the different refractive indices of water and air, phase contrast X-ray images clearly show the exact size and shape of over-lapped microbubbles. In all of the working fluids tested (deionized water, tap water, 0.01 and 0.10M NaCl solutions), the measured terminal velocity of the microbubbles rising through the solution was proportional to the square of the bubble diameter. The rising velocity was increased with increasing mole concentration. The microbubble can be useful as contrast agent or tracer in life science and biology. The X-ray PTV technique should be able to extract useful information on the behavior of various bio/microscale fluid flows that are not amenable to analysis using conventional methods.

  • PDF

사각탱크 내부의 기포구동유동에 대한 동특성 연구 (Dynamic Analysis of Bubble-Driven Liquid Flows in a Rectangular Tank)

  • 김상문;이승재;김현동;김종욱;김경천
    • 한국가시화정보학회지
    • /
    • 제8권1호
    • /
    • pp.31-38
    • /
    • 2010
  • An experimental study to evaluate dynamic structures of flow and turbulence characteristics in bubble-driven liquid flow in a rectangular tank with a varying flow rate of compressed air is conducted. Liquid flow fields are measured by time-resolved particle image velocimetry (PIV) with fluorescent tracer particles to eliminate diffused reflections, and by an image intensifier to acquire enhanced clean particle images. Instantaneous vector fields are investigated by using the two frame cross-correlation function and bad vectors are eliminated by magnitude difference technique. By proper orthogonal decomposition (POD) analysis, the energy distributions of spatial and temporal modes are acquired. When Reynolds number increases, bubble-induced turbulent motion becomes dominant rather than the recirculating flow near the side wall. The total kinetic energy transferred to the liquid from the rising bubbles shows a nonlinear relation regarding the energy input because of the interaction between bubbles and free surface.