Browse > Article
http://dx.doi.org/10.9708/jksci.2017.22.09.149

Study on bubble detection sensor for safe sap and blood injection  

Yun, Young Gi (Dept of Computer Science & Engineering. Kongju national university)
Lee, Hoo Young (Dept of Computer Science & Engineering. Kongju national university)
Park, Koo Rack (Dept of Computer Science & Engineering. Kongju national university)
Abstract
The infusion of fluid and blood is necessary in the ward, operating room, recovery room, neonatal room, etc. for nutrition and blood supply to the patient, but air bubbles generated during infusion of fluid and blood circulate along the artery or vein. Serious illnesses occur and there is also a risk of death. In this paper, we propose a medical bubble detection system, a bubble detection system, a bubble detection alarm system, and a communication method in order to develop a safer fluid and blood injection system in the existing system, which is detected by a medical staff monitoring system or an ultrasonic bubble detection sensor In this study, infrared rays are transmitted to a tube through a tube for injecting fluid or blood into a patient, infrared rays transmitted by an infrared ray emitting section are received, and the amount of light is measured in real time. Based on the data, we study how to detect and analyze the presence of bubbles in fluid and blood.
Keywords
Allocation; Bubble detection; Sap Injection; Infrared ray;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Jin Nam Kim, Won Tae Kwon, Kanghee Lee "Automatic Flow Control and Network Monitoring of IV Injection" The Journal of the Korean Society of Manufacturing Technology Engineers Vol. 21 No.1 pp.161-166, 2012.   DOI
2 Uslusoy E, Mete S. Predisposing factors to phlebitis in patients with peripheral intravenous catheters: a descriptive study. Journal of American Academy of Nurse Practitioners. pp172-180. 2008.
3 Wei Q. Lee J. H., Seong K. W. Kim M. N. Cho J. H. "The design of a wireless flexible capacitive sensor detection system to detect liquid level in plastic bag intravenous drip sets," Biomedical Engineering Letters, 2011.
4 Korea Industry and Technology Vision 2020 = The next big thing! : General remarks vol.1 2011.
5 A Study on the Strengthening of Manufacturing Competitiveness Using Internet of Things, Ministry of Trade, Industry and Energy, 2014.
6 Studies on Effective Fluid Monitoring Terminal design with the Use of location-based service, Journal of the KIECS. pp. 421-426, 2016.
7 Global Data, Infusion Systems-Global Pipeline Analysis, Competitive Landscape and Maket Forecasts to 2017.
8 Research to develop the guidelines for the evaluation & approval of medical devices: 8 items such as intravascular administration set, surgical drap, etc. National Institute of Food and Drug Safety Evaluation, 2011.
9 Jung Hoon Ro; Gyo-won Shin; Sang Guen Lee; Beong-Ik Hur. "Development of fluid infusion pump tester using drip sensor" Journal of Pusan national university hospital 33 pp399-416 2013.
10 Je-Ho Song, In-Sang Lee, You-Yub Lee. "Ringer's solution detector and transceiver design for efficient manage of patient", Journal of the Korea Academia-Industrial cooperation Society Vol. 17, No. 9 pp45-50, 2016   DOI
11 Jin Nam Kim, Won Tae Kwon, Kanghee Lee. "Automatic Flow Control and Network Monitoring of IV Injection". Journal of the Korean Society of Manufacturing Technology Engineers Vol.21 No.1 pp161-166, 2012.   DOI
12 H. S. Park, J. H. Kim, WEICHIN, J. H. Lee, K. Y. Seong, J. H. Jo. "Optical Sensor for Intravenous Solution Exhaustion Detecting". The Journal of the Rehabilitation Engineering And Assistive Technology Society of Korea, pp322-325. 2014.