• Title/Summary/Keyword: Air Brake System

Search Result 97, Processing Time 0.032 seconds

A Study of Thermal Behavior in Ventilated Disk Brake

  • Kim, Jin-Taek
    • KSTLE International Journal
    • /
    • v.7 no.2
    • /
    • pp.56-60
    • /
    • 2006
  • By the increasing amount of vehicles, the increase of car accident served as a major momentum for remind the importance of braking system. The adequate design of a passenger car braking system, which is directly related to the safety of a car, is very important since the safety is an essential design parameter of a car to keep men and car from the damage. The thermal behaviors of the ventilated disk has been investigated based on the air cooling effects during repeat braking operations. In this study, the temperature and velocity fields of 3-D unsteady simulated model are obtained using a software package "FLUENT". The numerical results show that there exits a temperature nonuniformity between the disk faces contacting with pads.

Development of the Braking Equipments for a Rubber-Tired AGT Light Rail Vehicle (고무차륜 AGT 경량전철용 제동장치의 개발)

  • 박성혁;김연수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1585-1588
    • /
    • 2003
  • Based on the design requirements for the rubber-tired AGT light rail vehicle. the braking system was designed. Its major components are a brake operating unit, a pneumatic-hydraulic transfer, screw compressor, oil separator. air dryer, hydraulic caliper. After the components of braking system were manufactured. some factory tests were executed to evaluate their performances. The Results of these tests can guarantee a performance. safety of the braking system developed.

  • PDF

An Analytical Study on the Improvement of the Performance of Swivel Valve Tube Couplers (스위벨 밸브 튜브 커플러 개발을 위한 해석 연구)

  • Lee, Jun-Ho;Sung, Jae-Kyeong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.1-6
    • /
    • 2011
  • This study focused on the localization of swivel type tube couplers, which all depend on imports. In this study, a computer application analysis was performed using a finite element method as a preliminary study. In the major developments related to the objective of this study, the air brake system produced by car makers represents a different in the installation point of an air tank according to the type of cars or in the length and direction of its hoses and that leads to cause lots of problems. For solving such problems, the design of the major elements in a swivel type tube coupler was analyzed using a finite element method, and its validity was also verified. In the process that verifies the validity of this study, it was necessary to investigate how much external force affects the desorption of the tube support, which is the most important element in swivel type tube couplers. For achieving the investigation, a pressure test was implemented for the tube support according to the Federal Motor Vehicle Safety Standards(FMVSS). In the results of the pressure test, all samples satisfied the FMVSS. In addition, several tests were implemented by installing the sample of the developed swivel type tube coupler to an actual vehicle. In particular, rotation tests with various angles were applied by welding the swivel type coupler to an air tank through an argon welding process. In the results of the installing test for an actual vehicle, it was verified that the designed structure was determined as a structure that is able to endure the eccentric torque and deformation pressure applied to several directions that are the major problems in such fixed type tube couplers. Therefore, in the comparison of the performance of the developed product with the product of PARKER, it was possible to verify that the localized swivel type tube coupler developed in this study shows more excellent than that of the existing products by PARKER.

Study on the Evaluation of Frictional Drag Reduction by Air Lubrication and the Arrangement of Air Injection Parts for a Liquefied Natural Gas Carrier (공기윤활에 의한 액화천연가스운반선의 마찰저항저감 평가 및 공기 분사부 배치에 대한 연구)

  • Kim, Hee-Taek;Kim, Hyoung-Tae;Kim, Hyun-Joe;Kim, Jung-Joong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.3
    • /
    • pp.144-157
    • /
    • 2021
  • Brake Horse Power (BHP) reduction ratios by air injection to the underside of the hull surface in an actual ship are predicted using an unstructured finite-volume CFD solver and compared with the sea trial results. In addition, air lubrication system installed on the existing vessel is investigated to find a good solution for additional drag reduction. As a results, it is found that the thickness of the air layer should be minimized within a stable range while securing the area covered by the air layer as much as possible. Furthermore, the amount of frictional drag reduced by air injection is found to be independent of surface roughness and still effective on rough surface. Based on the results of this study, it is expected that systematic and reliable air lubrication system can be designed and evaluated using the proposed method.

A study on Test and Evaluation & Technology of Brake Control System in High Speed Railway (고속철도 제동제어 시험평가기술 방법에 대한 연구)

  • Shin Yu-Jeong;Choi Kyung-Jin
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.103-108
    • /
    • 2005
  • Since the braking system of rolling stock is directly linked to it's safety, ensuring reliability of braking system and evaluation of performance of it are very important. To develope the performance of braking system, it is required advanced technology and gradually various factors in the field test result. This study is designed to analyze the air pressure control about braking force in rolling stock, also, by comparing braking force of KTX with that of high speed train. This paper suggests to establish a method of computation of braking force form the air pressure control. And The high speed train researches into patterns of braking system such as the train of speed up and introduction of electric and pneumatic braking system.

  • PDF

Development of a new test facility for the study of pressure transients in tunnel and micro-pressure waves radiated from the tunnel exit on the railroad (철도터널내 압력변동 및 터널 미기압파 저감 시험장치개발에 관한 연구)

  • Kim, Dong-Hyeon;Oh, Il-Geun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.611-618
    • /
    • 2000
  • The test facility of the 1/60-scale models for the train-tunnel interactions was recently developed to investigate the effects of entry portal shapes, hood shapes and air-shafts for reducing the micro-pressure waves radiating to the surroundings of the tunnel exits by KRRI in Korea. The launching system of train model was chosen as air-gun type. In present test rig, after train model is launched, the blast wave by the driver did not enter to inside of the tunnel model. The train model is guided on the one-wire system from air-gun driver to the brake parts of test facility end. Some cases of the experiments were compared with numerical simulations to prove the test facility.

  • PDF

Development of A New Facility for Moving Model Test (한국형 터널 미기압파 저감 시험기 개발)

  • 김동현;양신추;오일근
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.146-154
    • /
    • 1999
  • The test facility of the 1/60-scale models for the train-tunnel interactions was recently developed to investigate the effects of entry portal shapes, flood shapes and air-shafts for reducing the micro-pressure waves radiating to the surroundings of the tunnel exits by KRRI in Korea. The launching system of train model was chosen as air-gun type. In present test rig, after train model is launched, the blast wave by the driver did not enter to inside of the tunnel model. The train model is guided on the one-wire system from air-gun driver to the brake parts of test facility end. Some cases of the experiments were compared with numerical simulations to prove the test facility.

  • PDF

A STUDY ON THE ENGINE PERFORMANCE OF A SPARK IGNITION ENGINE ACCORDING TO THE IGNITION ENERGY

  • Han, Sung Bin
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.1-6
    • /
    • 2014
  • The more or less homogeneous fuel-air mixture that exists at the end of the compression process is ignited by an electric ignition spark from a spark plug shortly before top dead center. The actual moment of ignition is an optimization parameter; it is adapted to the engine operation so that an optimum combustion process is obtained. Brake mean effective pressure (BMEP) of the spark ignition energy control device (IECD) than conventional spark system at the stoichiometric mixture is increased about 9%. For lean burn engine, the lean limit is extended about 25% by using the IECD. It was considered the stability of combustion by the increase of flame kernel according to the high ignition energy supplies in initial period and discharge energy period lengthen by using the IECD.

Analysis of using Permanent Magnet Eddy Current Brake system (영구자석을 이용한 와전류 제동장치의 특성 해석)

  • Jang, S.M.;Cha, S.D.;Jeong, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.277-279
    • /
    • 2000
  • This paper proposes two kinds of the eddy current brake which uses permanent magnet. The one, like multipolar excitation consists of hexahedron shape of a segmented permanent magnetic and iron situated in the air-gap. The other, like multipolar excitation consists of only a segmented permanent magnetic. We use a finite element method to compute the flux distribution in the model. Also, we use the Galerkin-FEM with linear interpolation function may oscillate between the adjacent nodes to calculate the braking and attraction force. The advantages of the Halbach array are discussed.

  • PDF

A Study of the Friction Factor Unit Considering the Cost of Energy (에너지비용변화에 따른 경제적 단위마찰저항 값에 대한 고찰)

  • Shin, Dong-Shin;Kim, A-In;Lee, Byung-Hyun;Jung, Hyueong-Mok;Lee, Sung-Goo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.1
    • /
    • pp.29-34
    • /
    • 2016
  • The friction factor unit was studied to find a more economic alternative compared to the conventional 30 mmAq/m. The pipe and pump for cooling water piping used in a failing were selected, and the friction factor unit was changed to calculate the pipe diameter and the brake shaft power. Based on current electric charges, After the brake shaft power was converted into operational costs based on current electric charges, then an economic analysis was conducted considering that incorporated the initial installation costs and operational costs for the pump. We found that the friction factor unit when using 20 mmAq/m is more economical than that with 30 mmAq/m, if the piping is used for more than 4 years. The small friction factor unit is desirable when the piping is used for quite a long period of time, and the selection of a more economic friction factor unit should considering the period of usage will be important.