• Title/Summary/Keyword: Aging parameter

Search Result 136, Processing Time 0.025 seconds

Measurement of Ultrasonic Nonlinear Parameter by Using Non-Contact Ultrasonic Receiver (비접촉식 초음파 수신기를 이용한 초음파 비선형성 측정)

  • Kim, Jongbeom;Jhang, Kyoung-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1133-1137
    • /
    • 2014
  • The ultrasonic nonlinear parameter ${\beta}$ is generally known as an effective parameter for evaluating material degradation. Thus far, most research has been conducted using a contact method. However, since measurement by this contact method is affected by the contact conditions between the transducer and the specimen, additional devices are required to maintain the contact conditions stable during the measurement. To avoid this inconvenience, this paper proposes a noncontact method. In this study, only the receiver was replaced with a noncontact receiver, and then, the ultrasonic nonlinear parameters measured by the newly developed noncontact receiver were compared with those measured by the contact receiver. Results obtained using both these receivers for heat-treated aluminum alloy specimens showed good agreement. From this result, we can confirm that the ultrasonic nonlinear parameter ${\beta}$ can be measured using the proposed noncontact ultrasonic method.

Assessment of Residual Life for In-Service Fossil Power Plant Components Using Grain Boundary Etching Method (입계부식법에 의한 사용중인 화력발전소 요소의 잔여수명평가)

  • Han, Sang-In;Yoon, Kee-Bong;Chung, Se-Hi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.1
    • /
    • pp.22-31
    • /
    • 1997
  • The grain boundary etching method as a method for assessing degradation of structural materials has received much attention because it is simple, inexpensive and easy to apply to real components. In this study, the effectiveness of the method is verified by successfully applying the technique to in-service components of aged fossil power plants such as main steam pipes, boiler headers an turbine rotors. A new degradation parameter, intersecting number ratio (N$_{1}$/N$_{0}$), is employed. The intersecting number ratio (N$_{1}$/N$_{0}$) is defined as the ratio of intersection number (N$_{1}$) obtained from 5-minute picric acid etched surface to the number (N$_{0}$) obtained from nital etched surface. Two kinds of test materials, 2.25Cr-1Mo steel and 1Cr-1Mo-0.25V steel, were artificially thermal-aged at 630.deg. C in different levels of degradation., (N$_{1}$/N$_{0}$) were measured. And, correlations between the measured values and LMP values calculated from aging temperature and aging time were sought. To check the validity of the correlations obtained in laboratory, similar data were measured from service components in four old Korean fossil power plants. These on-site measurement data were in good correlation with those obtained in the laboratory.oratory.

Aging effect of Solution-Processed InGaZnO Thin-Film-Transistors Annealed by Conventional Thermal Annealing and Microwave Irradiation

  • Kim, Gyeong-Jun;Lee, Jae-Won;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.211.1-211.1
    • /
    • 2015
  • 최근 용액 공정을 이용한 산화물 반도체에 대한 연구가 활발히 진행되고 있다. 넓은 밴드갭을 가지고 있는 산화물 반도체는 높은 투과율을 가지고 있어 투명 디스플레이에 적용이 가능하다. 기존의 박막 진공증착 방법은 진공상태를 유지하기 위한 장비의 가격이 비싸며, 대면적의 어려움, 높은 생산단가 등으로 생산율이 높지 않다. 하지만 용액 공정을 이용하면 대기압에서 증착이 가능하고 대면적화가 가능하다. 그리고 각각의 조성비를 조절하는 것이 가능하다. 이러한 장점에도 불구하고, 소자의 신뢰성이나 저온공정은 중요한 이슈이다. Instability는 threshold voltage (Vth)의 shift 및 on/off switching의 신뢰성과 관련된 parameter이다. 용액은 소자의 전기적 특성을 열화 시키는 수분 과 탄소계열의 불순물을 다량 포함 하고 있어 고품질의 박막을 형성하기 위해서는 고온의 열처리가 필요하다. 기존의 열처리는 고온에서 장시간 이루어지기 때문에 유리나 플라스틱, 종이 기판의 소자에서는 불가능하지만 $100^{\circ}C$ 이하의 저온 공정인 microwave를 이용하면 유리, 플라스틱, 종이 기판에서도 적용이 가능하다. 본 연구에서는 산화물 반도체 중에서 InGaZnO (IGZO)를 용액 공정으로 제작한 juctionless thin-film transistor를 제작하여 기존의 열처리를 이용하여 처리한 소자와 microwave를 이용해서 열처리한 소자의 전기적 특성을 한 달 동안 관찰 하였다. 또한 In:Zn의 비율을 고정한 후 Ga의 비율을 달리하여 특성을 비교하였다. 먼저 p-type bulk silicon 위에 SiO2 산화막이 100 nm 증착된 기판에 RCA 클리닝을 진행 하였고, solution InGaZnO 용액을 spin coating 방식으로 증착하였다. Coating 후에, solvent와 수분을 제거하기 위해서 $180^{\circ}C$에서 10분 동안 baking공정을 하였다. 이후 furnace열처리와 microwave열처리를 비교하기 위해 post-deposition-annealing (PDA)으로 furnace N2 분위기에서 $600^{\circ}C$에서 30분, microwave를 1800 W로 2분 동안 각각의 샘플에 진행하였다. 또한, HP 4156B semiconductor parameter analyzer를 이용하여 제작된 TFT의 transfer curve를 측정하였다. 그 결과, microwave 열처리한 소자의 경우 기존의 furnace 열처리 소자와 비교하여 높은 mobility, 낮은 hysteresis 값을 나타내었으며, 1달간 소자의 특성을 관찰하였을 때 microwave 열처리한 소자의 경우 전기적 특성이 거의 변하지 않는 것을 확인하였다. 따라서 향후 용액공정, 저온공정을 요구하는 소자 공정에 있어 열처리방법으로 microwave를 이용한 활용이 기대된다.

  • PDF

A study on the TIG Welding Technology of Room Lamp for Vehicle (자동차용 실내등의 TIG 용접기술에 관한 연구)

  • Hahn Chang-Su;Cho Hyoung-Ki;Kim Jin-Pyeong;Park Ho;Kim Dong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.525-530
    • /
    • 2006
  • Recently companies which do not use the heavy metals such as lead, chrome, mercury to the electronic goods and alternate the materials environment-friendly are increasing. In advanced country, lead-free solder without lead is developed and soldering process almost disappeared. The lead-free solder is environment-friendly but is expensive and lack of tack and durability than lead, the improvement is necessary. To solve this problem, the welding process that uses TIG welding and the welding technology between different kind metals for lead-in wire of room lamp and base department was developed. To do this, previous room lamp manufacturing process was analysed and which process can be alternate was proposed. And the test for selection of optimal value of TIG welding parameter was done. Finally the lamp aging test and earthquake resistant test was done to check the reliability of welded room lamp.

  • PDF

Quantitative Changes of Collagen and Malonedialdehyde as the Parameters of Skin Alteration (피부노화의 지표가 되는 collagen과 malonedialdehyde의 정량적인 변화)

  • 김기영;이재형;진주영;양시용
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.1
    • /
    • pp.135-140
    • /
    • 2004
  • Anti-skin aging agent could be have an inhibition effect of ROS production as well as fragmentation and change of collagen cross linkage in collagen molecule. For the monitoring of lipid peroxidation and collagen degradation, the skin of young and old rats were incised and observed 7 days. In the result, the wound closure was observed in the skin from 10 of 11 young rats and in 8 of 11 old rats. And the longer wound length but shorter wound closure, weaker collagen density and thicker epidermis were observed in old rats than in young rats. The level of hydroxyproline as a parameter of collagen synthesis and MDA as a parameter of lipid peroxidation was lower in old group than in young group. The cyst and lacuna between collagen bundle and fibroblast were observed in old rats in contrast to young rats. So that we propose that MDA and hydroxyproline could be used for monitoring of anti-skin aging agent.

Application of Non-linear Acoustic Effect for Evaluation of Degradation of 2.25Cr-1Mo Steel (2.25Cr-1Mo 강의 열화도 평가를 위한 비선형 음향효과 응용법)

  • Choi, Y.H.;Jhang, K.Y.;Park, I.K.;Kim, H.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.170-176
    • /
    • 2002
  • Nonlinear acoustic effect has been considered as an effective tool for the evaluation of material degradation. In this paper, the applicability of nonlinear acoustic effect to the evaluation of degraded 2.25Cr-1Mo steel is investigated. Firstly, artificial aging was performed to simulate the microstructural degradation in 2.25Cr-1Mo steel arising from long time exposure at $540^{\circ}C$. Secondly, ultrasonic nonlinear parameter was quantitatively measured by bi-spectrum and power spectrum. Nonlinear acoustic parameter from bi-spectrum was found to be clearly sensitive to the aging time.

Determination of New Parameter for Materials Degradation Using Continuous Indentation Testing Technique (연속압입 시험기법을 이용한 석유화학설비 경년손상의 새로운 평가변수 고찰)

  • Jang, Jae-Il;Choi, Yeol;Son, Dongil;Lee, Yun-Hee;Kwon, Dongil;Kim, Jeoung-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.5
    • /
    • pp.881-889
    • /
    • 2002
  • Newly developed continuous indentation technique has made nondestructive assessment of tensile properties possible. The present study was undertaken to determine new parameters for indicating time-dependent material degradation of petro-chemical plant. Continuous indentation tests were performed for Cr-Ni steel and Cr-Mo steel which are widely used as facilities of petro-chemical plant. From the results, it was found that yield strength and tensile strength cannot be used as general degradation parameters because the changes in the strengths with aging time didn't show any tendency. On the other hand, work hardening exponent and yield ratio showed consistent tendency with increasing aging time. Therefore, nam attention of this work was paid on them as new degradation parameters, and the in-field applicability of the parameters was evaluated and discussed.

A Statistical Analysis to the VLF Tanδ Criteria for Aging Diagnosis in Power Cables (전력케이블 열화진단을 위한 극저주파 탄델타 판정기준의 통계적 해석)

  • Jung, Woosung;Kim, Seongmin;Lim, Jangseob;Lee, Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.1
    • /
    • pp.1-5
    • /
    • 2020
  • In this study, the objective is to improve the criteria used for statistical comparison of the VLF tanδ (TD) database and failure rate according to water-tree degradation in underground distribution power cables. The aging condition of the KEPCO criteria is divided into 6 levels using the Weibull distribution, and the "failure imminent" condition is quantified by using the statistical end-point of the lifetime parameter of the VLF big-data group obtained from KEPCO. Moreover, new criteria with a 2-dimensional combination of TD, DTD, and a statistical normalized factor are suggested. These criteria exhibit high reproducibility for the detection of cables in an imminent failure state. Consequently, it is expected that the adoption of the extended VLF-2019 criteria will reduce the asset management cost of cable replacement compared to the VLF-2012 criteria of KEPCO.

Study on the Adhesive Strength by the Manufacturing Process Parameter of the Aluminum Pouch for Secondary Battery (이차전지용 알루미늄 파우치 필름의 제조 공정 변수에 따른 접착력에 대한 연구)

  • Yu, Min Sook;Kim, Do Hyun;Cho, Jung Min;Bae, Sung Woo;Kim, Dong Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.2
    • /
    • pp.149-155
    • /
    • 2016
  • In this study, we investigated the adhesive strength by molecular weight, mixture ratio, coating thickness, lamination temperature and aging condition of adhesive in manufacture process of Nylon-Aluminum for secondary aluminum pouch. It found that as the molecular weight of adhesive gets lower, the adhesive strength increases. In the mixture ratio, as the content of hardener get higher and as the content of solvent get lower, the adhesive strength increases. Also, as the coating thickness of adhesive get thicker, the adhesive strength increase. In addition, the adhesive strength is higher at 90 degrees of lamination temperature. So, it found that 90 degrees of lamination temperature is appropriate. In the aging condition when aged for 5 days, it found that the reaction and curing of adhesive is sufficient by measuring the adhesive strength.

Electrical Characteristic Changes of ZnO Varistors by Energy Absorption

  • Kim, Woo-Hyun;Hwang, Seong-Cheol;Wang, Guoming;Kil, Gyung-Suk;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.12
    • /
    • pp.817-821
    • /
    • 2017
  • As a ZnO varistor is subjected to electrical and environmental stresses, it degrades gradually, which may result in power interruption by short circuit. This study investigates changes in the electrical characteristics of ZnO varistors due to deterioration owing to energy absorption, and determines the optimal parameters for on-line diagnosis of the varistor. Two types of varistors were used for an accelerated aging experiment involving the application of the $8/20{\mu}s$ standard lightning impulse current. The electrical characteristics in terms of the reference voltage, total leakage current, resistive leakage current, and third-harmonic component of the total leakage current were measured, and their change rates were analyzed. The results revealed that the total leakage current increased slightly with an increase in the varistor absorbed energy, while the resistive leakage current and the third-harmonic component increased apparently. Therefore, the third-harmonic component of the total leakage current was proposed as the optimal parameter for on-line monitoring of ZnO varistor conditions.