• Title/Summary/Keyword: Aging failure

Search Result 332, Processing Time 0.024 seconds

Estimation of Break Outflow from the Goeyeon Reservoir Using DAMBRK Model (DAMBRK 모형을 이용한 괴연저수지 붕괴유출량 추정)

  • Lee, Jin Young;Park, Dong Hyeok;Kim, Seong-Joon;Kim, Tae-Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.459-466
    • /
    • 2017
  • Several reservoirs that were managed by local governments and the Korea Rural Community Corporation have recently collapsed. One of them is the Goeyeon reservoir in Yeongcheon-si, Gyeongsangbuk-do that collapsed mainly around the spillway due to heavy rain at 9 O'clock, on 21 August 2014. The Goeyeon reservoir was an aging agricultural reservoir over 70 years since it was built. In this study, the collapse situation of the reservoir was reproduced through the DAMBRK model. Flood inundation maps were reconstructed for the breach outflow of the dam analyzed by the DAMBRK model. We estimated the breach duration and outflow of the reservoir as compared with the inundation image taken by the Unmanned Aerial Vehicle (UAV) at the time when the Goeyeon reservoir collapsed. The results of this study are expected to be useful for predicting damage in the downstream inundation area when a reservoir collapses.

Partial Discharge Measurement of Power Cables for Nuclear Power Plant (원자력발전소 전력케이블 부분방전 진단 사례)

  • Ha, Che-Wung;Ju, Kwang-Ho;Lim, Woo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1632-1638
    • /
    • 2011
  • Electric cables are one of the most important components in a nuclear power plant since they provide the power needed to operate electrical equipment. Despite their importance, cables typically receive little attention since they are considered passive, long-lived components that have been very reliable over the years when subjected to the environmental conditions for which they were designed. The operating experience reveals that a defect of the insulator or poor construction causes the initial failure of cable. However, the number of cable failures increase with plant aging, and these cable failures are occurring within the plants' 40-year licensed period. These cable failures have resulted in plant transients, shutdown, loss of safety functions or redundancy, entries into limiting conditions for operation, and challenges for plant operators. Therefore, diagnosis of MV cable installed in NPPs has become one of the most urgent issues in recent years. In accordance with PSR, condition maintenance for cables is also continuously required. Recently, HFPD tests have been widely performed to diagnose cable in the transmission and distribution cable system. However, on-line HFPD wasn't used in the NPPs because of the danger of plant shutdown, measurement sensitivity and application problems, etc. In this paper, HFPD measurement with portable device was performed to evaluate the integrity of the 4.16kV & 13.8kV cable lines. The test results show that HFPD is highly attractive to the diagnosis of MV cables in NPP by high detection sensitivity on-site.

A Study on the Application of Pre-Indentation Technique for Fastener Hole Model (FASTENER HOLE 모델의 대한 예비압입 적용 연구)

  • Hwang,Jeong-Seon;Jo,Hwan-Gi
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.9
    • /
    • pp.26-31
    • /
    • 2003
  • Aging aircraft accumulates widespread fatigue damage commonly referred to as multiple site damage(MSO). For ductile material such as 2024-T3 aluminum, MSO may lower the service life below that which is predicted by conventional fracture mechanics. The present paper is concerned with the fatigue life extension by pre-indentation technique for thin 2024-T3 aluminum plate to decelerate the crack propagation rate in the panels with MSO. The panel with fastener holes can be simply modelled by Hole/Slot type Middle-Tension specimen. Results of fatigue testing show significantly improving failure cycles from 10 to 40 times. This retardation effect is decreased by increasing the loading level in the constant amplitude loading. In the sense of retardation mechanism, the crack propagation rate is gradually attenuated by entering the indentation mark and maintains at the lowest value for a long period after the edge of crack passes the center of indentation area.

Research on Sanitation Control for an HACCP Application for a Flatfish (Paralichthys olivaceus) Aquaculture Farm (넙치 양식장 HACCP 적용을 위한 위생관리에 대한 연구)

  • Jee, Bo-Young;Min, Jin-Gi;Kim, Tae-Jin;Choi, Jae-Suk;Park, Sun-Mee
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.5
    • /
    • pp.1179-1191
    • /
    • 2013
  • Many sanitation control problems due to aging facilities and equipment were identified when applying an HACCP system to a flatfish (Paralichthys olivaceus) aquaculture farm. Specifically, the major problems included a lack of awareness about worker hygiene, lack of management of the use of fish medicines, and vulnerability to secondary contamination by cross-contamination owing to a failure to separate breeding tools used for healthy and unhealthy fish. Therefore, the management standards on the farm regarding the surrounding environment, facilities and equipment, breeding tools, feed and medication, and the hygiene of practitioners must be improved. The hygiene management standards were divided into different procedures such as the management of farm hygiene and environmental sanitation, facilities and equipment, fish hygiene, feed, medications, water, and the stocking and shipping of fish. For each procedure, we established the management standards, inspection period, inspection procedures, and how to deal with errors that occur, to enable hygiene management by a small number of managers. Additionally, an inspection system and record form to implement an HACCP system were developed to maintain systematic management. The management and inspection of all aspects of the farm were designed to be easily managed by the supervisor.

Investigation and Assessment of the Deterioration on Aging Large Water Mains (대형 상수관로 노후상태 조사 및 평가에 관한 연구)

  • Kim, Ju-Hwan;Bae, Chul-Ho;Kim, Jung-Hyun;Hong, Sung-Ho;Lee, Kyung-Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.545-558
    • /
    • 2006
  • The current conditions of large water mains are evaluated by deteriorations and the causes of deterioration are investigated through visual assessments in the field, mechanical tests and analysis of chemical compositions in laboratory for each pipe material, unlined cast iron pipes (CIPs), ductile iron pipes (DCIPs) and steel pipes (SPs) Tubercles and scales from internal and external corrosion of unlined cast iron pipes were identified as the causes of functional performance limitations in large water mains. It is investigated that main causes of internal and external corrosion of water pipes are from lots of depositions of organic and inorganic substances on pipe surface, concentrated pitting, and uniform corrosion by local or global exfoliation or detachment of lining and coatings of DCIPs and SPs. Internal and external corrosion depths of CIPs were higher than those of DCIPs and SPs. Consequently, total corrosion rate summed internal and external corrosion rates of CIPs also were shown to be higher than those of DCIPs and SPs. The failure time from hole generation of CIPs by total corrosion rate was predicted to be taken sixteen years, and DCIPs and SPs were twenty-six years and one hundred and fifty three years. And longitudinal deflection of investigated water mains were not happened and mechanical strengths such as tensile strength, elongation, and hardness also were mostly suited to Korea Standards. It was thought that the weakness of tensile strength of one sample(S-11) was, however, due to higher carbon contents(%) in CIPs. Pipe deterioration score of S-46 was 55.2 and was preferentially assessed to be rehabilitated.

New Approach for Sustainable Technology: Strategic Niche Management (지속가능한 기술을 향한 새로운 접근: 전략적 니치관리(Strategic Niche Management))

  • Park, Dong-Oh;Song, Wi-Chin
    • Journal of Science and Technology Studies
    • /
    • v.8 no.2
    • /
    • pp.57-81
    • /
    • 2008
  • This paper reviewed outline of Strategic Niche Management(SNM) and its usefulness and limits as policy tool. SNM is based on Multi Level Perspective(MLP) that traces technological innovation and makes transition of lock-in socio-technical system. This approach is one of systematical then traditional one, market failure approach. SNM had get a attention not only as a analytical frame of technological development, but also tool of radical innovation, although its limits of theoretical and empirical immaturity. SNM could provide a new perspective to analysis and action within urgent needs of alternative innovation policy for aging society, news energy policy for sustainable and disaster policy in danger society.

  • PDF

An Empirical Study of the Mediating Effect of Governance in Relationship between Resident Participation and Rural Community Design Project Performance - Focused on the Case of Utturu Village - (주민참여와 농촌 마을만들기 사업성과의 관계에서 거버넌스의 매개효과 실증분석 - 제주 웃뜨르권역 사례를 중심으로 -)

  • Kang, Ki-Ho;Lee, Jin-Hee
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.1
    • /
    • pp.103-115
    • /
    • 2015
  • As rural development projects, mostly carried out in a top-down development method in the past came to take a bottom-up development method in earnest, entering the 2000s, resident participation became an essential element of a rural community design project, to the extent that it can influence the success or failure of a rural community design project. It is taken for granted that rural residents independently participate in community design projects, but as they are accustomed to various subsidy projects carried out by the government and become increasingly aging, it is not easy to induce their spontaneous participation in farming areas with such problems. Especially, to prevent the distrust between administrative agencies and residents from serving as an obstacle in the residents' spontaneous participation, it is necessary to construct horizontal governance among the village residents, administrative agencies and the group of experts supporting for the project. This study attempted to verify the mediating effect of governance in the relationship between resident participation and the performance of the rural community design project based on this problem recognition, and for this purpose, the results of a survey with residents in Utturu Village, Hangyeong-myeon, Jeju-si, which was completed by carrying out a comprehensive rural development project, the typical bottom-up community design project was used for an empirical analysis. The results of the study can provide implications for setting directions, establishing strategies and constructing governance of rural community design projects in the future, and especially, it can be said that this study has academic significance in that governance is recognized as an important variable related to the project performance.

Survey on the Malfunction of MCCB and ELB in Private Electrical Facilities (자가용 수용가에서 배선용 및 누전차단기 오동작에 대한 조사연구)

  • Yoo, Jae-Geun;Lee, Sang-Ick;Jeon, Jeong-Chay
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.87-93
    • /
    • 2005
  • Recently, nuisance tripping or malfunction of MCCB(Melded Case Circuit Breaker) and ELB(Electrical Leakage Breaker) is being increased according as load circuits and equipments of electrical customers are various and complicated, but investigation of actual conditions on malfunction of MCCB and ELB was not implemented This paper investigated causes and influences of malfunction of MCCB and ELB by making up a question to electrical safety managers of two hundred and eighteen private electrical facilities. The results show that users above $70[\%]$ experienced malfunction of MCCB and ELB, and causes of malfunction are in order aging(above $25(\%)$), nuisance tripping $(above\;22(\%))$, goods badness$(above\;20(\%))$, abnormal power like as harmonics$(above\;20(\%))$ and others $(about\;9(\%))$. Also, second damages due to failure of MCCB and ELB are in order goods production, equipment trouble, information loss, business and operation interrupt, and others. The results of this study can be used in making decisions regarding causes of MCCB and ELB trip.

A Study on Material Degradation and Fretting Fatigue Behavior (재질 열화와 프레팅 피로거동 평가에 관한 연구)

  • Gwon, Jae-Do;Seong, Sang-Seok;Choe, Seong-Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.8
    • /
    • pp.1287-1293
    • /
    • 2001
  • Fretting is a potential degradation mechanism of structural components and equipments exposed to various environments and loading conditions. The fretting degradation, for example, for example, can be observed in equipments of nuclear, fossil as well as petroleum chemical plants exposed to special environments and loading conditions. It is well known that a cast stainless steel(CF8M) used in a primary reactor coolant(RCS) degrades seriously when that material is exposed to temperature range from 290$\^{C}$∼390$\^{C}$ for long period. This degradation can be resulted into a catastrophical failure of components. In the present paper, the characteristics of the fretting fatigue are investigated using the artificially aged CF8M specimen. The specimen of CF8M are prepared by an artificially accelerated aging technique holding 180hr at 430$\^{C}$ respectively. Through the investigations, the simple fatigue endurance limit of the virgin specimen is not altered from that obtained from the fatigue tests imposed the fretting fatigue. The similar tests are performed using the degraded specimen. The results are not changed from those of the virgin specimen. The significant effects of fretting fatigue imposed on both virgin and degraded specimen on the fatigue strength are not found.

Enhanced Adhesion of Tire Cords via Plasma Polymerizations (플라즈마 중합에 의한 타이어 코드의 접착성 향상연구)

  • Kim, R.K.;Sohn, B.Y.;Han, M.H.;Kang, H.M.;Yoon, T.H.
    • Elastomers and Composites
    • /
    • v.34 no.2
    • /
    • pp.128-134
    • /
    • 1999
  • Steel tire cords were coated via RF plasma polymerization of acetylene and butadiene gas in order to enhance adhesion to rubber compounds. Adhesion of tire cords was measured by TCAT and T-test as a function of type of gas, plasma powder, treatment time, gas pressure and Ar gas etching. Some samples were subjected to aging study in distilled water at $80^{\circ}C$ for a period of 7 days. After testing, tire cords were analysed by SEM to elucidate the adhesion mechanism. The highest adhesion values were obtained at 20W, 2min and 25mtorr for acetylene plasma polymerization, and l0W, 4min, 25mtorr for butadiene plasma polymerization. However, Ar plasma etching did not affect adhesion, while the adhesion of tire cords increased rather than decreased, contrary to expectations. It was not possible to elucidate failure mode by SEM, owing to the rough surface of the tire and the thin plasma polymer coating layer.

  • PDF