• Title/Summary/Keyword: Aging factor

Search Result 878, Processing Time 0.023 seconds

Sensitivity Analysis of Parameters Affecting Seismic Response for RC Shear Wall with Age-Related Degradation (경년열화된 철근콘크리트 전단벽의 지진응답에 영향을 미치는 변수들의 민감도분석)

  • Park, Jun-Hee;Choun, Young-Sun;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.4
    • /
    • pp.391-398
    • /
    • 2011
  • After a concrete is poured, reinforced concrete structures were distressed by physical and chemical factor over time. It is in need to define important variables related to structural behavior for effectively conducting seismic analysis of structures with age-related degradation. In this study, a sensibility analysis using the first-order second moment method was performed to analyze an important variables for the reinforced concrete shear wall with age-related degradation. Because the seismic capacity of aging structures without a concrete hardening effect can be underestimated, the sensibility of analysis variables was analyzed according to the concrete hardening. Important variables for RC shear wall with age-related degradation was presented by using the tornado diagram.

Structural characterization of As-MIF and hJAB1 during the inhibition of cell-cycle regulation

  • Park, Young-Hoon;Jeong, Suk;Ha, Ki-Tae;Yu, Hak Sun;Jang, Se Bok
    • BMB Reports
    • /
    • v.50 no.5
    • /
    • pp.269-274
    • /
    • 2017
  • The biological activities of macrophage migration inhibitory factor (MIF) might be mediated through a classical receptor-mediated or non-classical endocytic pathway. JAB1 (C-Jun activation domain-binding protein-1) promotes the degradation of the tumor suppressor, p53, and the cyclin-dependent kinase inhibitor, p27. When MIF and JAB1 are bound to each other in various intracellular sites, MIF inhibits the positive regulatory effects of JAB1 on the activity of AP-1. The intestinal parasite, Anisakis simplex, has an immunomodulatory effect. The molecular mechanism of action of As-MIF and human JAB1 are poorly understood. In this study, As-MIF and hJAB1 were expressed and purified with high solubility. The structure of As-MIF and hJAB1 interaction was modeled by homology modeling based on the structure of Ace-MIF. This study provides evidence indicating that the MIF domain of As-MIF interacts directly with the MPN domain of hJAB1, and four structure-based mutants of As-MIF and hJAB1 disrupt the As-MIF-hJAB1 interaction.

Classification of the Lower Half of the Body by the Somatotypes of Elderly Men (노년 남성의 하반신 체형 유형화에 관한 연구)

  • Seok, Hye-Jung;Im, Nam-Young
    • Journal of the Korean Society of Costume
    • /
    • v.59 no.8
    • /
    • pp.123-131
    • /
    • 2009
  • This study aims at presenting the basic data related to the somatotype of elderly men at the point of Korea's entering into an aging society. Efforts were made to classify the lower-half somatotype of elderly men, with the application of the measurements of 261 elderly men of 60 years of age and over up to 70, which were available from the physique measurement survey project for Koreans. The number of analysis items was 31. The statistical treatment was made through SPSS win 12.0 program, and the analytical methods used were the basic statistics, factor analysis, and cluster analysis. The findings are as follows: Elderly men experienced the decreases in height and weight, in comparison with middle-aged ones, while they showed a flat shape at trunk, with more protruded waist and abdomen and with flat buttock. The analysis of the constituting factors for the lower-half body of elderly men resulted in the 6 items. The elements constituting the lower-half body of elderly men included the shape from waist to hip, the spread of hip and height of knee, the shape of leg, thigh size, the length of leg, and the volume of abdominal. The total accountability was 81.59 %. The cluster analysis for lower-half somatotype of elderly men resulted in the classification of three types. The above findings are intended to assist the designing of ready-made slacks with a high level of fitness for elderly men.

Relative Effects of Health and Family Factors on Geriatric Depression (노인 우울에 영향을 미치는 요인: 건강요인과 가족요인의 상대적 영향력을 중심으로)

  • Lee, Mee-Ae
    • The Korean Journal of Community Living Science
    • /
    • v.22 no.4
    • /
    • pp.623-635
    • /
    • 2011
  • Over the past few decades, the proportion of elderly people with depression in Korea has been rapidly increasing. The purpose of this study is to explore relative effects of health and family factors on geriatric depression. The data sources are from Korean Longitudinal Study of Aging(2008). The Analysis sample consists of 4,040 cases. Analysis results show that there is a significant variability in geriatric depression according to sociodemographic characteristics, health characteristics, and family characteristics. Hierarchical logistic regression analyses are employed to assess the causal relationship between health characteristics and geriatric depression. Model II showed that ADL(exp(B)=1.732), having difficulties due to sight deterioration(exp(B)=1.398), having difficulties due to masticatory force deterioration(exp(B)=1.414), having difficulties due to pain(exp(B)=2.435), and subjective health status(exp(B)=2.010) are reported as predictors of geriatric depression. Namely, the probability of having geriatric depression of the above predictors has been 1.7 times, 1.4 times, 1.4 times, 2.4 times. 2.0 times higher than normal figures. Among health characteristics, pain is the most prevalent factor. Model III showed that as for family characteristics, coresiding with children(exp(B)=1.312) and frequency of contacting with children by phones, letters, or emails(exp(B)=1.477) are reported as predictors of geriatric depression. Key findings are that health factors have larger effects than family factors on geriatric depression.

A Study on Estimation of Liquid Leakage Using Wide Angle Camera Based Angled of Arrival Algorithm in Bio Plant

  • Shin, Jaekwon;Mariappan, Vinayagam;Woo, Deokgun;Lee, Junghoon;Lee, Jisung;Kim, Minsoo;Kim, Jintae
    • International journal of advanced smart convergence
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • In addition to the instability of energy import costs caused by the depletion of petroleum resources, which is a representative energy resource, and the strengthening of various regulations such as the convention on climate change, the plant for bio energy production, which is being watched as the next generation energy, and became subject of various complaints. In order to solve this problem, the bio-plant is underground and the ground is parked, making the convenience and accessibility of citizens more and more accessible. In this situation, the development of bioenergy production technology also increases the risk factor in bioenergy production process. Accordingly this paper explains method about apply the wide angle camera based AOA algorithm to the bio plant to prevent the accidents from spreading due to the lack of facilities and safety devices and the aging of the facilities and suggests a technique that can quickly identify the location and direction when it occurs.

An ionization Chamber for a Steel Sheet Thickness Measurement

  • Kim, Han-Soo;Park, Se-Hwa;Kim, Yong-Kyun;Ha, Jang-Ho;Cho, Seung-Yeon
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.149-153
    • /
    • 2006
  • An ionization chamber is still widely used in many fields by virtue of its' simple operational characteristics and the possibility of its' various shapes. A parallel type of an ionization chamber for a steel sheet thickness measurement was designed and fabricated. High pure xenon gas, which was pressurized up to 6 atm, was chosen as a filling gas to increase the current response and sensitivity for a radiation. A high pressure gas system was also constructed. The active volume and the incident window size of the fabricated ionization chamber were $30\;cm^3\;and\;12\;cm^2$, respectively. Preliminary tests with a 25 mCi $^{241}Am$ gamma-ray source and evaluation tests in a standard X-ray field were performed. The optimal operation voltage was set from the results of the collection efficiency calculation by using an experimental two-voltage method. Linearity for a variation of the steel sheet thickness, which is the most important factor for an application during a steel sheet thickness measurement, was 0.989 in this study.

Parameter Identification of 3R-C Equivalent Circuit Model Based on Full Life Cycle Database

  • Che, Yanbo;Jia, Jingjing;Yang, Yuexin;Wang, Shaohui;He, Wei
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1759-1768
    • /
    • 2018
  • The energy density, power density and ohm resistance of battery change significantly as results of battery aging, which lead to decrease in the accuracy of the equivalent model. A parameter identification method of the equivale6nt circuit model with 3 R-C branches based on the test database of battery life cycle is proposed in this paper. This database is built on the basis of experiments such as updating of available capacity, charging and discharging tests at different rates and relaxation characteristics tests. It can realize regular update and calibration of key parameters like SOH, so as to ensure the reliability of parameters identified. Taking SOH, SOC and T as independent variables, lookup table method is adopted to set initial value for the parameter matrix. Meanwhile, in order to ensure the validity of the model, the least square method based on variable forgetting factor is adopted for optimizing to complete the identification of equivalent model parameters. By comparing the simulation data with measured data for charging and discharging experiments of Li-ion battery, the effectiveness of the full life cycle database and the model are verified.

A Study on Characteristics of Sensory Richness Towards Healing Environments at the Lobby of Geriatric Hospital Using Biophilic Design Approach (바이오필릭 디자인에 기반한 노인요양병원 로비공간의 다감각적 치유환경에 관한 연구)

  • Lee, Dami;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.3
    • /
    • pp.21-30
    • /
    • 2016
  • For the elderly with declining sensory due to aging, various sense stimulation factors provided in indoor environment is desirable healing environment. This study aims to propose the direction of sensory healing environment by adapting the richness of natural environment in indoor place based on the biophilic design theory with implementation method of sensory richness environment. The healing environment was limited to the ward in the beginning, but it has widened its range to the whole place, and the lobby is considered quiet important to healing. Therefore, this study selected lobby space of geriatric hospital as study subject. As for the study method, we deducted the analytic matrix focusing on the property and elements of the direct and indirect experience of nature appearing in the biophilic design theory, and analyzed the field investigation of subject space. Also, this study paid attention to point where the hotel lobby leads the change of emotional environment, and conducted analysis and comparison by deciding this is what the hotel and geriatric hospital should direct to. As the result, the biophilic design factor of hotel is actively expressed by complex direction of various factors, but as for the geriatric hospital, it was rather passive and simple in expression. The adaptation ratio between hotel and geriatric hospital was almost more than twice times difference in average.

Analyzing the Spatial Centrality of Rural Villages for Green-Tourism using GIS and Social Network Analysis -Focusing on Rural Amenity and Human Resources- (GIS 및 사회네트워크 분석을 통한 농촌마을 관광중심성 분석 -농촌어메니티 자원 및 인적자원을 중심으로-)

  • Lee, Sang-Hyun;Choi, Jin-Yong;Bae, Seung-Jong;Oh, Yun-Gyeong
    • Journal of Korean Society of Rural Planning
    • /
    • v.15 no.1
    • /
    • pp.47-59
    • /
    • 2009
  • The aim of this study is to analyze the green-tourism centrality considering spatial interaction using Gravity Model and social network method. The degree centrality and prestige centrality were applied as green-tourism centrality index. The rural amenity resources and human resources were counted as attraction factors, and a distance among villages was used as friction factor in gravity model. The weights of rural tourism amenity resources were calculated using the analytic hierarchy process(AHP) method and applied to evaluate green-tourism potentiality. The distance was measured with the shortest path among villages using geographic information system(GIS) network analysis. The spatial interaction from gravity model were employed as link weights between nodal points; a pair villages. Using the spatial interaction, the degree-centrality and prestige-centrality indices were calculated by social network analysis and demonstrated possibility of developing integrated green-tourism region centered on high centrality villages.

Analysis of Insulation Aging in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 절연열화 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik;Lee, Young-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.200-203
    • /
    • 2006
  • Prior to destructive testing, diagnostic tests were performed in eight high voltage motors. Diagnostic tests included polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharge magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 1 motor failed near rated voltage of 12.96 kV. The breakdown voltage of No. 4 motor was 6.99 kV which is lower that expected for good quality coils in 6.6 kV class motors. The failure was located in a line-end coil at the exit from the core slot. These two motors began operation in 1994. While testing No. 7 motor, flashover occurred between the stator winding and the stator frame at 15 kV. The relationship between the diagnostic test and the drop in insulation breakdown voltage was analyzed.

  • PDF