• Title/Summary/Keyword: Aging degradation

Search Result 577, Processing Time 0.019 seconds

A Study on Degradation Behavior of 1Cr-1Mo-0.25V Steel (1Cr-1Mo-0.25V 강의 열화거동에 관한 연구)

  • 석창성;구재민;김동중;안하늘;박은수
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.8-14
    • /
    • 2000
  • The remaining life estimation for the aged components in power plants as well as chemical plants are very important because mechanical properties of the components are degraded with time of service exposure in the high temperature. Since it is difficult to take specimens from the operating components to evaluate mechanical properties of components, accelerated aging technique are needed to estimate and analyse the material degradation. In the this study, test materials with 4 different degradation levels were prepared by isothermal aging heat treatment at $630^{\circ}C$. And tensile test, $k_{IC}$ test, hardness test and Scanning Electron Microscope analysis were performed in order to evaluate the degradation of 1Cr-1Mo-0.25V steels.

  • PDF

Development of Materials Degradation Evaluation Program for Nuclear Power Plants (원전 재료열화 평가프로그램 개발)

  • Shin, Ho-Sang;Oh, Young Jin
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.23-29
    • /
    • 2011
  • The renewed global interest in nuclear power has arisen from the need to reduce greenhouse gas emissions and to provide sufficient electricity for a growing global population before the accident at Fukushima Dai-ichi nuclear power plant in Japan. In spite of the safety issues of nuclear power plants raised by the ongoing Japanese nuclear crisis, many countries with nuclear power plants (NPPs) are still implementing license extensions of 10~20 years, and even consideration is being given to the concept of life-beyond-60, a further period of license extension from 60 to 80 years. To solving the materials aging problem is integral to its success. To evaluate the plant aging phenomena, a lot of background information such as materials and environment of the parts of the reactor and plant systems is needed by the experts. Information on degradation mechanisms is also used. In this paper, a materials degradation evaluation program called OnMDE-SYS (On-line Materials Degradation Evaluation System) is introduced. The developed program provides a variety of information on the materials and stressors as well as operational experience to the experts. It is also anticipated that the experts can perform materials degradation assessment on the web directly by referring to domestic and international information about the degradation of a nuclear power plants through OnMDE-SYS.

Development of a Safety Assessment System on Aging Management in Existing CANDU Steam Generators (가압중수로 증기발생기의 경년열화 관리를 위한 안전성 평가 시스템 개발)

  • Shin, So Eun;Lee, Jeong Hun;Park, Tong Kyu;Jung, Jong Yeob
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.10 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • Since steam generator (SG) tubes are located in the boundary between the primary and secondary systems of nuclear power plant (NPP), the SG is one of the most important components in the aspects of the safety of NPP. The magnetite ($Fe_30_4$) deposition, so-called fouling, is generally known as a major aging mechanism of CANDU SGs, and this aging mechanism makes the heat transfer efficiency between the primary and secondary systems of NPP reduced. Therefore, the development of SG safety assessment system which can evaluate the effect of the SG aging degradation mechanism should be needed for safety of NPP. In this study, through the suggestion of the guideline for SG safety assessment, it is possible to strengthen the basic of establishing the effective SG aging management technique. The SG safety assessment is carried out by CATHENA(Canadian Algorithm for THErmalhydraulic Network Analysis). It is possible to determine the integrity of SGs by identifying the main safety parameters which can be changed by the aging degradation of CANDU SGs.

Evaluation of the $\sigma$-Phase Degradation for Cast Stainless Steel CF8M by the Electrochemical Method (전기화학적 방법에 의한 주조 스테인리스강 CF8M $\sigma$상 열화평가)

  • Gwon, Jae-Do;Kim, Jung-Hyeong;Park, Jung-Cheol;Byeon, Jang-Hwan;Lee, U-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.11 s.170
    • /
    • pp.2014-2021
    • /
    • 1999
  • The present investigation is concerned with the degradation characteristics of cast stainless steel(CF8M), exposed to the $\sigma$-phase degradation at $700^{\circ}C$. In the present paper, the degradation of CF8 M at $700^{\circ}C$ is evaluated by a non-destructive test, DL-EPR(double loop electrochemical potentiokinetic reactivation). The surface of specimens is observed by using scanning electron microscopy after DL-EPR test. Also. chromium contents of matrix, grain boundary and ferrite phase are analyzed by electron probe X-ray micro analyzer. Through the experiments, the following results are obtained 1) The degree of sensitization(DOS) of CF8M aged up to 15hr at $700^{\circ}C$ is increased with acing time while that is decreased with aging time from 15hr to 150hr. 2) The impact energy decreases with increase of $\sigma$-phase while DOS increases with $\sigma$-phase until aging time reaches to 15hr. After the aging time. 15hr, the $\sigma$-phase and the rate of impact energy with respect to aging time decreases. Therefore the degradation behavior of the CF8M can be evaluated by comparing SEM micrographs and the value of DOS.

A Boundary-Scan Based On-Line Circuit Performance Monitoring Scheme (경계 스캔 기반 온-라인 회로 성능 모니터링 기법)

  • Park, Jeongseok;Kang, Taegeun;Yi, Hyunbean
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.51-58
    • /
    • 2016
  • As semiconductor technology has developed, device performance has been improved. However, since device structures became smaller, circuit aging due to operational and environmental conditions can be accelerated. Circuit aging causes a performance degradation and eventually a system error. In reliable systems, a failure due to aging might cause a great disaster. Therefore, these systems need a performance degradation prediction function so that they can take action in advance before a failure occurs. This paper presents an on-line circuit performance degradation monitoring scheme for predicting a failure by detecting performance degradation during circuit normal operation. In our proposed scheme, IEEE 1149.1 output boundary scan cells and TAP controller are reused. The experimental result shows that the proposed architecture can monitor the performance degradation during normal operation without stopping the circuit.

DGA Gases related to the Aging of Power Transformers for Asset Management

  • Kweon, Dongjin;Kim, Yonghyun;Park, Taesik;Kwak, Nohong;Hur, Yongho
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.372-378
    • /
    • 2018
  • Life management technology is required as the failure risk of aged power transformers increases. Asset management technology is developed to evaluate the remaining life, establish the replacement strategies, and decide the optimal investment based on the reliability and economy of power transformers. The remaining life assessment uses data such as installation, operation, maintenance, refurbishment, and failure of power transformers. The optimal investment also uses data such as maintenance, outage, and social costs. To develop the asset management system for power transformers, determining the degradation parameters related to the aging of power transformers and evaluating the condition of power transformers using these parameters are important. In this study, since 1983, 110,000 Dissolved Gas Analysis (DGA) data have been analyzed to determine the degradation parameters related to the aging of power transformers. The alarm rates of combustible gases ($H_2$, $C_2H_2$, $C_2H_4$, $CH_4$, and $C_2H_6$), TCG, CO, and $CO_2$ were analyzed. The end of life and failure rate (bathtub curve) of power transformers were also calculated based on the failure data from 1981 to 2014. The DGA gases related to discharge, overheating, and insulation degradation were determined based on alarm and failure rates. $C_2H_2$, $C_2H_6$, and $CO_2$ were discharge, oxidation, and insulation degradation parameters related to the aging of power transformers.

Degradation Behavior and Micro-Hardness Analysis of a Coolant Rubber Hose for Automotive Radiator (자동차용 냉각기 고무호스의 노화거동과 미소경도분석)

  • Kwak, Seung-Bum;Shin, Sei-Moon;Shin, Wae-Gi;Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.9
    • /
    • pp.915-923
    • /
    • 2007
  • Rubber hoses for automobile radiators are apt to be degraded and thus failed due to the influence of contacting stresses of air and coolant liquid under thermal and mechanical loadings. The aging behaviors of the skin part of the hoses due to thermo-oxidative and electro-chemical stresses were experimentally analyzed. Through the thermo-oxidative aging test, it was shown that the surface hardness IRHD(International Rubber Hardness Degrees) of the rubber increased with a considerable reduction of failure strain as the aging time and temperature increased. On account of the penetration of coolant liquid into the skin part influenced by the electro-chemical degradation(ECD) test the weight of the rubber hose increased, whereas their failure strain and IRHD hardness decreased. The hardness of the hose in the side of the negative pole was the most deteriorated at the test site of the hose skin just below the coolant surface.

Evaluation of Ultimate Pressure Capacity of Light Water Reactor Containment Considering Aging of Materials (재료의 경년상태를 고려한 경수로형 격납건물의 극한내압능력 평가)

  • Lee, Sang-Kuen;Song, Young-Chul;Han, Sang-Hoon;Kwon, Yong-Gil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.147-154
    • /
    • 2001
  • The prestressed concrete containment is one of the most important structures in nuclear power plants, which is required to prevent release of radioactive or hazardous effluents to the environment even in the case of a severe accident. Numerical analyses are carried out by using the ABAQUS finite element program to assess the ultimate pressure capacity of the Y prestressed concrete containment with light water reactor at design criteria condition and aging condition considering varied properties of time-dependant materials respectively. From the results, it is verified that the structural capacity of the Y prestressed concrete containment building under the present, aging condition is still robust. In addition, the parameter studies for the reduction of the ultimate pressure capacity of containment building according to the degradation levels of the main structural materials are carried out. The results show that when the degradations of each materials are considered as individual and combined forms, the influence is large in the order of tendon, rebar and concrete degradation, and tendon-rebar, tendon-concrete and rebar-concrete degradation respectively.

  • PDF

A Study on Synthetic Failure-finding Method for Electrical and Thermal Degradation of Polymer Insulator by Surface Discharge

  • Lee, Kang-Won;Jang, Dong-Uk;Park, Cheol-Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.143-146
    • /
    • 2007
  • Polymer insulators are used widely in variable fields for high voltage insulation and separating people from high voltage charging parts for safety and also supporting overhead power line in electric railway. But it may be broken down by tracking path resulting from continuous surface discharge. This paper has investigated synthetically both the characteristics of electrical aging using precision CT(current transformer) and the thermal aging using thermography method. Electrical aging was analyzed for time-frequency region and thermal aging was illustrated by image processing method. This synthetic method may be an appropriate one to evaluate the surface degradation of polymer insulator.

Long-Term Aging Diagnosis of Rotor Steel Using Acoustic Nonlinearity

  • Kim, Chung-Seok;Park, Ik-Keun;Jhang, Kyung-Young;Hyun, Chang-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.6
    • /
    • pp.642-649
    • /
    • 2011
  • The long-term aging of ferritic 2.25CrMo steel was characterized using the acoustic nonlinear effect in order to apply to diagnose the degradation behavior of structural materials. We measured the acoustic nonlinearity parameter for each thermally aged specimen by the higher harmonic-generation technique. The acoustic nonlinearity parameter increased with aging time due to equilibrium M6C carbide precipitation, and has a favorable linear relation with Rockwell hardness. This study suggests that acoustic nonlinearity testing may be applicable to diagnostics on strength degradation in rotor steels.