Browse > Article
http://dx.doi.org/10.14248/JKOSSE.2014.10.1.049

Development of a Safety Assessment System on Aging Management in Existing CANDU Steam Generators  

Shin, So Eun (FNC Technology Co., Ltd.)
Lee, Jeong Hun (FNC Technology Co., Ltd.)
Park, Tong Kyu (FNC Technology Co., Ltd.)
Jung, Jong Yeob (KAERI)
Publication Information
Journal of the Korean Society of Systems Engineering / v.10, no.1, 2014 , pp. 49-56 More about this Journal
Abstract
Since steam generator (SG) tubes are located in the boundary between the primary and secondary systems of nuclear power plant (NPP), the SG is one of the most important components in the aspects of the safety of NPP. The magnetite ($Fe_30_4$) deposition, so-called fouling, is generally known as a major aging mechanism of CANDU SGs, and this aging mechanism makes the heat transfer efficiency between the primary and secondary systems of NPP reduced. Therefore, the development of SG safety assessment system which can evaluate the effect of the SG aging degradation mechanism should be needed for safety of NPP. In this study, through the suggestion of the guideline for SG safety assessment, it is possible to strengthen the basic of establishing the effective SG aging management technique. The SG safety assessment is carried out by CATHENA(Canadian Algorithm for THErmalhydraulic Network Analysis). It is possible to determine the integrity of SGs by identifying the main safety parameters which can be changed by the aging degradation of CANDU SGs.
Keywords
CANDU; Steam Generator; Aging Management; Safety Assessment System; Fouling; CATHENA;
Citations & Related Records
연도 인용수 순위
  • Reference
1 KAERI (Korea Atomic Energy Research Institute), Development of realistic safety analysis technology for CANDU reactors, 2009 (in Korean).
2 PSR (Periodic Safety Review) of the Wolsong unit 1, 2003 (in Korean).
3 KINS, Development of periodic safety review guidelines, KINS/RR-139, 2002 (in Korean).
4 R.L. Tappin, J. Nickerson, P. Spekkens C., Maruska, CANDU steam generator life management, Nuclear Engineering and Design, 197 (2000)213-223, 2000.   DOI   ScienceOn
5 KINS(Korea Institute of Nuclear Safety), Study on assessment of the integrity of steam generator in Wolsong 1, in KINS/RR-766, 2010 (in Korean).
6 Georg Kraemer, Dr. Christoph Stiepani, Steam generator cleanliness management-Inner diameter SG tube cleaning with the SIVABLAST process, 4th international CANDU in-service-inspection workshop NDT in CANADA 2012 conference, 2012.
7 D.H. Lister, J. Slade, and N. Arbeau, The accelerated corrosion of CANDU outlet feeders-observations, possible mechanisms and potential remedies, CNS proceedings of the 1997 CNA/CNS annual conference on powering Canada's future, 1997.
8 Han-sub Chung, A review of CANDU feeder wall thinning, Nuclear Engineering and Technology Vol.42 No.5, 2010.
9 CATHENA MOD-3.5d/Rev 2 GENHTP Input Reference, 153-112020-UM-002, 2005.
10 KINS, Investigation of aging elements effected on safety margin and DB system for CANDU reactors, KINS/RR-386, 2006 (in Korean).