• Title/Summary/Keyword: After-cooling

Search Result 1,291, Processing Time 0.027 seconds

The Solution of Severe Vibration Problen of the Secondary Cooling Pump in HANARO (하나로 2차 냉각펌프의 고진동 해소방안)

  • Park, Yong-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.4 s.17
    • /
    • pp.26-31
    • /
    • 2002
  • The heat produced by the fission in the fuel of HANARO, 30 MW of research reactor, was transferred from the primary cooling water to the secondary cooling water through heat exchangers. The secondary cooling water absorbing the heat was circulated by secondary cooling pumps and cooled through 33 MW of cooling tower. Each capacity of the three secondary cooling pumps was fifty percent ($50\%$) of full load. The two pumps were normally operated and the other pump was standby. One of the secondary cooling pumps has often made troubles by high vibration. To release these troubles the pump shaft has been re-aligned, the pump bearing has been replaced with new one, the shaft sleeve has been replaced with new one, the shaft and the impeller have been re-balanced representatively and/or the vibration of motor has been tested by disconnecting the shaft of pump. But the high vibration of pump cannot be cleared. We find out the weight balance trouble of the assembly in which the impeller is installed in the shaft. After clearing the trouble, the high vibration is relieved and the pump is operated smoothly. In this paper, the trouble solution shooting method of secondary cooling pump is described including the reason of high vibration

PERFORMANCE EVALUATION OF COOLING CHANNELS IN A PLASTIC INJECTION MOLD MODEL (사출금형의 냉각채널 성능 평가)

  • Kim, H.S.;Han, B.Y.;Lee, I.C.;Kim, Y.M.;Park, H.K.
    • Journal of computational fluids engineering
    • /
    • v.17 no.2
    • /
    • pp.53-57
    • /
    • 2012
  • Design of the cooling channels of a plastic injection mold affects the quality and the productivity of the injection processes. In the injection process, the melted resin with high temperature enters the mold cavity, and just after the cavity is filled the heat should be dissipated through the cooling channels simultaneously. The purpose of this study is to analyse the heat transfer phenomenon and to estimate the temperature distribution in the mold to evaluate the cooling effect of the channels. The injection mold is assumed to have cooling channels of circular cross section and each channel has the same coolant flow rate. and The cavity has a rectangular shape. The results show that as the cooling channels get closer to the cavity surface, the cooling efficiency increases as might easily be guessed. However, due to the final hot resin flow from the gate an intensive cooling is required in that region.

The Solution of High Vibration of the Secondary Cooling Pump in HANARO (하나로 2차 냉각펌프의 고진동 해소방안)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.197-202
    • /
    • 2001
  • The heat produced by the fission in the fuel of HANARO, 30 MW of research reactor, was transferred from the primary cooling water to the secondary cooling water through heat exchangers. The secondary cooling water absorbed the heat was circulated by secondary cooling pumps and cooled through 33 MW of cooling tower. Each capacity of the three secondary cooling pumps was fifty percent ($50\%$) of full load. The two pumps were normally operated and the other pump was standby. One of the secondary cooling pumps has often get troubles by high vibration. To release these troubles the pump shaft has been re-aligned, the pump bearing has been replaced with new one, the shaft sleeve has been replaced with new one, the shaft and the impeller have been re-weight balanced representatively or the vibration of motor has been tested by disconnecting the shaft of pump. But the high vibration of pump cannot be cleared. We find out the weight balance trouble of the assembly that the impeller is installed in the shaft. After clearing the trouble, the high vibration is released and the pump is operated with smooth. In this paper the trouble solution of secondary cooling pump is described including the reason of high vibration.

  • PDF

Effect of Cooling Rate on Lamellar Structure and Hardness of Discontinuous Precipitates in Mg-Al-Zn Alloy (Mg-Al-Zn 합금에서 불연속 석출물의 층상 구조와 경도에 미치는 냉각 속도의 영향)

  • Jun, Joong-Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.33 no.6
    • /
    • pp.271-276
    • /
    • 2020
  • The relationship between the hardness and interlamellar spacing of discontinuous precipitates (DPs) formed by continuous cooling was studied for Mg-9%Al-1%Zn alloy. After solution treatment at 683 K for 24 h, the specimens were cooled to room temperature with different cooling rates ranging from 0.2 to 2 K·min-1, in order to obtain DPs with various interlamellar spacings. It was found that cooling rate of 2 K·min-1 yielded only small amount of nodular DPs at the grain boundaries, while cooling rates below 2 K·min-1 yielded both DPs and continuous precipitates (CPs). The volume fraction of DPs increased with increasing cooling rate up to 0.5 K·min-1, over which it abruptly decreased. The hardness of DPs was increased with an increase in the cooling rate, whereas the interlamellar spacing of the DPs was decreased with respect to cooling rate. The hardness of the DPs formed by continuous cooling was correlated with the interlamellar spacing and can follow a Hall-Petch type relation as in the case of pearlite with lamellar morphology.

The effect of different cooling rates and coping thicknesses on the failure load of zirconia-ceramic crowns after fatigue loading

  • Tang, Yu Lung;Kim, Jee-Hwan;Shim, June-Sung;Kim, Sunjai
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.152-158
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the influence of different coping thicknesses and veneer ceramic cooling rates on the failure load of zirconia-ceramic crowns. MATERIALS AND METHODS. Zirconia copings of two different thicknesses (0.5 mm or 1.5 mm; n=20 each) were fabricated from scanning 40 identical abutment models using a dental computer-aided design and computer-aided manufacturing system. Zirconia-ceramic crowns were completed by veneering feldspathic ceramics under different cooling rates (conventional or slow, n=20 each), resulting in 4 different groups (CONV05, SLOW05, CONV15, SLOW15; n=10 per group). Each crown was cemented on the abutment. 300,000 cycles of a 50-N load and thermocycling were applied on the crown, and then, a monotonic load was applied on each crown until failure. The mean failure loads were evaluated with two-way analysis of variance (P=.05). RESULTS. No cohesive or adhesive failure was observed after fatigue loading with thermocycling. Among the 4 groups, SLOW15 group (slow cooling and 1.5 mm chipping thickness) resulted in a significantly greater mean failure load than the other groups (P<.001). Coping fractures were only observed in SLOW15 group. CONCLUSION. The failure load of zirconia-ceramic crowns was significantly influenced by cooling rate as well as coping thickness. Under conventional cooling conditions, the mean failure load was not influenced by the coping thickness; however, under slow cooling conditions, the mean failure load was significantly influenced by the coping thickness.

A study on thermal fluid analysis in X-ray tube for non-fire alarm (비화재보를 위한 X-ray tube 내 열 유동해석에 관한 연구)

  • Yun, Dong-Min;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.16 no.2
    • /
    • pp.33-38
    • /
    • 2022
  • Currently, Korea is an aging society, and it is expected to enter a super-aging society in about 4 years. Accordingly, many X-ray technologies are being developed. In X-rays, 99% of X-rays are converted into heat energy and 1% into light energy (X-rays). 99% of the thermal energy raises the temperature of the anode and its surroundings, and the cooling system is an important factor as overheating can affect the deterioration of X-ray quality and shortened lifespan. There is a method of forced air cooling using natural convection. Therefore, in this study, when X-rays were taken 5 times, Flow analysis was performed on heat removal according to temperature rise and cooling time for the heat generated at the anode of the X-ray tube (input power 60kW, 75kW, 90kW). Based on one-shot, the most rapid temperature rise section increased by more than 57% to 0.03 seconds, A constant temperature rises from 0.03 seconds to 0.1 seconds, It is judged that the temperature rises by about 8.2% or more at one time. After one-shot cooling, the cooling drops sharply from about 60% to 0.03 seconds, It is judged that the temperature has cooled by more than 86% compared to the temperature before shooting. One-shot is cooled by more than 86% with cooling time after 0.1 seconds, As the input power of the anode increases, the cooling temperature gradually increases. Since the tungsten of the anode target inside the X-ray tube may be damaged by thermal shock caused by a rapid temperature rise, an improvement method for removing thermal energy is required when using a high-input power supply.

Evaluation of Cooling Process for Marine Shaft Forging Products (선박용 축류 단조품 냉각공정 평가)

  • Park, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.352-357
    • /
    • 2020
  • This study was performed to solve the quality problems of forging propeller shaft components in the marine diesel engines during the final cooling process and provide reasonable guidelines to increase the production of forging products. Residual hydrogen existing on the inside of forging products begins to diffuse and accumulates at the pores, micro-fissures, and grain boundaries as the temperature of forging products begins to decrease and reaches a critical temperature range, and finally transforming into internal defects. These defects were easily found near the surface of products after milling the surface of forging products. In this work, four types of forging products (shaft flange, shaft journal, thrust shaft, and propeller shaft) were chosen to evaluate the temperature history of products during the cooling process, employing non-linear numerical analyses with the ANSYS program. The times elapsed to reach 250 ℃ after cooling were approximately 9 ~ 23 hours for each forging product. These times can be used as cooling process guidelines on the quality and productivity of products after heat treatment.

Effects of cooling systems on physiological responses and intestinal microflora in early gestating sows exposed to high-temperature stress

  • Jeong, Yongdae;Choi, Yohan;Kim, Doowan;Min, Yejin;Cho, Eunsuk;Kim, Joeun
    • Journal of Animal Science and Technology
    • /
    • v.63 no.4
    • /
    • pp.904-918
    • /
    • 2021
  • This study was conducted to investigate the effect of cooling systems on reproductive performance, body temperature, blood metabolites, and the intestinal microbiome in early gestating sows exposed to high ambient temperature. In total, 39 pregnant sows (Landrace × Yorkshire; 2 parities) were randomly assigned to and maintained in the following three treatment groups (13 sows per group) over days 0 to 35 of pregnancy: (i) air cooling (AC; 26.87 ± 1.23℃), (ii) water-drip cooling (WC; 28.81 ± 0.91℃), and (iii) a lack of cooling with heat stress (HS; 30.72 ± 0.70℃). Backfat thickness was measured before and after HS. Feces were collected on day 0 and 35 d of the trial for microbiome analysis, whereas blood was taken at day 35 of pregnancy and analyzed. Reproductive performance and physiological responses were identified at day 35. Respiration rate along with rectal and skin temperatures were lower (p < 0.05) in the AC group than in the HS and WC groups. Serum blood urea nitrogen values were increased (p < 0.05) in the WC group compared with those measured in the AC and HS groups. Triiodothyronine was found at greater levels (p < 0.05) in the AC than in the HS group. Reproductive performance was not affected by the cooling systems. At the phylum level, fecal pathogenic Spirochaete and Euryarchaeota were found in higher numbers (p < 0.05) in all groups after HS. Similarly, at the genus level, the amount of Treponema was greater (p < 0.05) in all groups after HS. In conclusion, our results suggest that AC or WC can ameliorate or mitigate the adverse effects of HS on the physiological parameters of pregnant sows reared under high temperatures.

Comparison of the Quality of Highland-Grown Kimchi Cabbage 'Choon Gwang' during Cold Storage after Pretreatments (수확 후 전처리에 의한 고랭지 배추 '춘광' 품종의 저온 저장 중 품질 변화에 대한 비교)

  • Bae, Sang Jun;Eum, Hyang Lan;Kim, Byung-Sup;Yoon, Jungro;Hong, Sae Jin
    • Horticultural Science & Technology
    • /
    • v.33 no.2
    • /
    • pp.233-241
    • /
    • 2015
  • Kimchi cabbage 'Choon Gwang' cultivar that was grown in highlands in Gangneung was subjected to predrying, room cooling, and forced air cooling, and then packed with/without 0.02 mm HDPE film to investigate the effect of postharvest treatment on quality characteristics during 8 weeks storage at $2^{\circ}C$ (RH $90{\pm}5%$). Weight loss in forced air cooling and room cooling was lower than 3-4% with 0.02 mm HDPE film liner treatment during storage. However, it was only below 10% in room cooling without liner treatment and forced air cooling without liner treatment led to the highest weight loss, above 15%. Conversely, the control had lower weight loss than the others. SSC was $2-4^{\circ}brix$ for all treatments and there was no difference between postharvest treatments and liner treatments. Color index and firmness both showed no differences with/without 0.02 mm HDPE film and postharvest treatments. In sensory evaluation, forced air cooling with liner treatment was effective, with the highest score, especially in appearance and crispness. After 6 weeks, control kimchi cabbage without liner treatment was damaged seriously in appearance and the internal color had changed to brown. Room cooling and predrying with liner treatment changed the start of internal browning to after 8 weeks storage.